• 제목/요약/키워드: pure bending

검색결과 212건 처리시간 0.02초

Experimental study on standard and innovative bolted end-plate beam-to-beam joints under bending

  • Katula, Levente;Dunai, Laszlo
    • Steel and Composite Structures
    • /
    • 제18권6호
    • /
    • pp.1423-1450
    • /
    • 2015
  • The paper presents the details and results of an experimental study on bolted end-plate joints of industrial type steel building frames. The investigated joints are commonly used in Lindab-Astron industrial buildings and are optimized for manufacturing, erection and durability. The aim of the research was to provide an experimental background for the design model development by studying load-bearing capacity of joints, bolt force distribution, and end-plate deformations. Because of the special joint details, (i.e., joints with four bolts in one bolt-row and HammerHead arrangements), the Eurocode 3 standardized component model had to be improved and extended. The experimental programme included six different end-plate and bolt arrangements and covered sixteen specimens. The steel grade of test specimens was S355, the bolt diameter M20, whereas the bolt grade was 8.8 and 10.9 for the two series. The end-plate thickness varied between 12 mm and 24 mm. The specimens were investigated under pure bending conditions using a four-point-bending test arrangement. In all tests the typical displacements and the bolt force distribution were measured. The end-plate plastic deformations were measured after the tests by an automatic measuring device. The measured data were presented and evaluated by the moment-bolt-row force and moment-distance from centre of compression diagrams and by the deformed end-plate surfaces. From the results the typical failure modes and the joint behaviour were specified and presented. Furthermore the influence of the end-plate thickness and the pretension of the bolts on the behaviour of bolted joints were analysed.

유연성 유기 박막트랜지스터 적용을 위한 다층 게이트 절연막의 전기적 및 기계적 특성 향상 연구 (Improvement of Electrical and Mechanical Characteristics of Organic Thin Film Transistor with Organic/Inorganic Laminated Gate Dielectric)

  • 노화영;설영국;김선일;이내응
    • 한국표면공학회지
    • /
    • 제41권1호
    • /
    • pp.1-5
    • /
    • 2008
  • In this work, improvement of mechanical and electrical properties of gate dielectric layer for flexible organic thin film transistor (OTFT) devices was investigated. In order to increase the mechanical flexibility of PVP (poly(4-vinyl phenol) organic gate dielectric, a very thin inorganic $HfO_2$ layers with the thickness of $5{\sim}20nm$ was inserted in between the spin-coated PVP layers. Insertion of the inorganic $HfO_2$ in the laminated organic/inorganic structure of PVP/$HfO_2$/PVP layer led to a dramatic reduction in the leakage current compared to the pure PVP layer. Under repetitive cyclic bending, the leakage current density of the laminated PVP/$HfO_2$/PVP layer with the thickness of 20-nm $HfO_2$ layer was not changed, while that of the single PVP layer was increased significantly. Mechanical flexibility tests of the OTFT devices by cyclic bending with 5 mm bending radius indicated that the leakage current of the laminated PVP/$HfO_2$(20 nm)/PVP gate dielectric in the device structure was also much smaller than that of the single PVP layer.

Investigation on the flexural behaviour of ferrocement pipes and roof panels subjected to bending moment

  • Alnuaimi, A.S.;Hago, A.W.;Al-Jabri, K.S.;Al-Saidy, A.H.
    • Structural Engineering and Mechanics
    • /
    • 제33권4호
    • /
    • pp.503-527
    • /
    • 2009
  • This paper presents experimental results on the behaviour and ultimate load of fifteen pipes and six roof panels made of ferrocement. Additional results from three roof panels, carried out by others, are also compared with this research results. OPC cement, natural sand and galvanised iron wire mesh were used for the construction of 20 mm thick specimens. The pipe length was 2 m and roof panel length was 2.1 m. The main variables studied were the number of wire mesh layers which were 1, 2, 3, 4 and 6 layers, the inner pipe diameter which were 105, 210 and 315 mm, cross sectional shape of the panel which were channel and box sections and the depth of the edge beam which were 95 mm and 50 mm. All specimens were simply supported and tested for pure bending with test span of 600 mm at mid-span. Tests revealed that increasing the number of wire mesh layers increases the flexural strength and stiffness. Increasing the pipe diameter or depth of edge beam of the panel increases the cracking and ultimate moments. The change in the pipe diameter led to larger effect on ultimate moment than the effect of change in the number of wire mesh layers. The box section showed behaviour and strength similar to that of the channel with same depth and number of wire mesh layers.

균일한 휨모멘트가 작용하는 파형강판 복부판 I-거더의 횡-비틂 좌굴강도 평가 (Evaluation of Lateral-Torsional Buckling Strength of I-Girder with Corrugated Web under Uniform Bending)

  • 문지호;이종원;최병호;이학은
    • 한국강구조학회 논문집
    • /
    • 제19권5호
    • /
    • pp.463-472
    • /
    • 2007
  • 본 연구에서는 균일한 휨모멘트가 작용하는 파형강판 복부판 I-거더의 횡-비틂 좌굴강도에 관하여 이론적 접근 및 유한요소해석을 이용하여 연구를 수행하였다. 횡-비틂 좌굴 강도는 박판 구조를 갖는 I-단면의 휨부재를 설계 하는데 중요한 인자이다. 하지만 파형강판 복부판 I-거더의 뒴비틀림 상수와 같은 비틀림 거동에 대한 이해가 현재까지는 부족한 실정이며, 이에 대한 연구가 필요하다. 본 연구에서는 휨 및 순수 비틀림 상수를 기존 연구자들의 결과를 이용하여 요약하였으며, 그 후 파형강판 복부판 I-거더 단면의 전단 중심의 위치와 뒴비틀림 상수를 유도하였다. 이러한 단면 상수들을 이용하여 파형강판 복부판 I-거더의 횡-비틂 좌굴 강도를 결정하였으며, 유한요소해석을 수행하여 제안된 파형강판 복부판 I-거더의 횡-비틂 좌굴 강도를 검증하였다. 마지막으로 파형강판의 기하학적 제원이 횡-비틂 좌굴강도에 미치는 영향에 관하여 연구를 수행하였다.

Experimental and numerical investigation on the behavior of concrete-filled rectangular steel tubes under bending

  • Zhang, Tao;Gong, Yong-zhi;Ding, Fa-xing;Liu, Xue-mei;Yu, Zhi-wu
    • Structural Engineering and Mechanics
    • /
    • 제78권3호
    • /
    • pp.231-253
    • /
    • 2021
  • Pure bending loading conditions are not frequently occurred in practical engineering, but the flexural researches are important since it's the basis of mechanical property researches under complex loading. Hence, the objective of this paper is to investigate the flexural behavior of concrete-filled rectangular steel tube (CFRT) through combined experimental and numerical studies. Flexural tests were conducted to investigate the mechanical performance of CFRT under bending. The load vs. deflection curves during the loading process was analyzed in detail. All the specimens behaved in a very ductile manner. Besides, based on the experimental result, the composite action between the steel tube and core concrete was studies and examined. Furthermore, the feasibility and accuracy of the numerical method was verified by comparing the computed results with experimental observations. The full curves analysis on the moment vs. curvature curves was further conducted, where the development of the stress and strain redistribution in the steel tube and core concrete was clarified comprehensively. It should be noted that there existed bond slip between the core concrete and steel tube during the loading process. And then, an extensive parametric study, including the steel strength, concrete strength, steel ratio and aspect ratio, was performed. Finally, design formula to calculate the ultimate moment and flexural stiffness of CFRTs were presented. The predicted results showed satisfactory agreement with the experimental and FE results. Additionally, the difference between the experimental/FE and predicted results using the related design codes were illustrated.

단일 나사형 Cage를 이용한 후방 요추체간 융합술과 두개의 나사형 Cage를 이용한 PLIF의 생체 역학적 비교 (Posterior Lumbar Interbody Fusion Using Posterolateral Placement of A Single Cylindrical Threaded Cage and Two Regular Cages : A Biomechanical Study)

  • 박춘근;황장회;지철;권성오;성재훈;최승진;이상원;김문규;박성찬;조경석;박춘근;;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권7호
    • /
    • pp.883-890
    • /
    • 2001
  • Objectives : An in vitro biomechanical study of posterior lumbar interbody fusion(PLIF) with threaded cage using two different approaches was performed on eighteen functional spinal units of bovine lumbar spines. The purpose of this study was to compare the segmental stiffnesses among PLIF with one long posterolateral cage, PLIF with one long posterolateral cage and simultaneous facet joint fixation, and PLIF with two posterior cages. Methods : Eighteen bovine lumbar functional spinal units were divided into three groups. All specimens were tested intact and with cage insertion. Group 1(n=12) had a long threaded cage($15{\times}36mm$) inserted posterolaterally and oriented counter anterolaterally on the left side by posterior approach with left unilateral facetectomy. Group 2(n=6) had two regular length cages($15{\times}24mm$) inserted posteriorly with bilateral facetectomy. Six specimens from group 1 were then retested after unilateral facet joint screw fixation in neutral(group 3). Likewise, the other six specimens from group 1 were retested after fixation with a facet joint screw in an extended position(group 4). Nondestructive tests were performed in pure compression, flexion, extension, lateral bending, and torsion. Results : PLIF with a single cage, group 1, had a significantly higher stiffnesses than PLIF with two cages, group 2, in left and right torsion(p<0.05). Group 1 showed higher stiffness values than group 2 in pure compression, flexion, left and right bending but were not significantly different. Group 3 showed a significant increase in stiffness in comparison to group 1 for pure compression, extension, left bending and right torsion(p<0.05). For group 4, the stiffness significantly increased in comparison to group 1 for extension, flexion and right torsion(p<0.05). Although there was no significant difference between groups 3 and 4, group 4 had increased stiffness in extension, flexion, right bending and torsion. Conclusion : Posterior lumbar interbody fusion with a single long threaded cage inserted posterolaterally with unilateral facetectomy enables sufficient decompression while maintaining a majority of the posterior elements. In combination with a facet joint screw fixation, adequate postoperative stability can be achieved. We suggest that posterolateral insertion of a long threaded cage is biomechanically an ideal alternative to PLIF.

  • PDF

2축 편심 축력을 받는 고강도 콘크리트 기둥의 수정 등가응력블럭 (Modified Rectangular Stress Block for High Strength RC Columns to Axial Loads with Bidirectional Eccentricities)

  • 유석형;반병열;신성우
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.335-343
    • /
    • 2003
  • 철근 콘크리트 보의 휨 해석 시 적용되는 콘크리트 압축연단의 극한변형률(${\varepsilon}$$_{cu}$) 과 등가응력블럭 계수(${\beta)$$_1$)는 1축 뿐 만 아니라 2축 휨 해석에도 적용될 수 있는 것으로 여러 실험결과를 통하여 검증되었다. 그러나 2축 휨을 받는 기둥 단면에서와 같이 압축영역이 비직사각형인 경우 극한변형률과 등가응력블럭 계수는 압축영역이 직사각형인 경우와 달라지게 되고, 이와 같은 압축영역 형태에 따른 콘크리트 응력분포 특성의 변화는 기둥과 같이 고축력을 받는 경우 단면의 휨 강도에 중요한 영향을 끼치게 된다. 그러나 ACI318-99에서 제시하는 기둥의 2축 휨 설계도표는 1축과 2축 휨 해석에 동일한 응력분포 특성치를 적용하여 산출되었다. 본 논문에서는 중립축 각도와 깊이에 따른 응력분포 특성을 파악하고 이를 합리적으로 수식화 함으로써 수정된 단면 소성해석 모델을 제시하였다. 또한 제시된 소성해석 모델을 적용한 기둥 단면해석 Program을 개발하고 해석 결과를 기존의 소성해석 모델 및 실험결과와 비교하였다.

Nonlinear vibration of hybrid composite plates on elastic foundations

  • Chen, Wei-Ren;Chen, Chun-Sheng;Yu, Szu-Ying
    • Structural Engineering and Mechanics
    • /
    • 제37권4호
    • /
    • pp.367-383
    • /
    • 2011
  • In this paper, nonlinear partial differential equations of motion for a hybrid composite plate subjected to initial stresses on elastic foundations are established to investigate its nonlinear vibration behavior. Pasternak foundation and Winkler foundations are used to represent the plate-foundation interaction. The initial stress is taken to be a combination of pure bending stress plus an extensional stress in the example problems. The governing equations of motion are reduced to the time-dependent ordinary differential equations by the Galerkin's method. Then, the Runge-Kutta method is used to evaluate the nonlinear vibration frequency and frequency ratio of hybrid composite plates. The nonlinear vibration behavior is affected by foundation stiffness, initial stress, vibration amplitude and the thickness ratio of layer. The effects of various parameters on the nonlinear vibration of hybrid laminated plate are investigated and discussed.

유동상로를 이용한 질화처리티타늄의 피로강도 특성 (Fatigue properties of nitrided titanium using fluidized bed furnace)

  • 김민건;지정근
    • 대한기계학회논문집A
    • /
    • 제22권1호
    • /
    • pp.142-147
    • /
    • 1998
  • Rotary bending fatigue tests were carried out on the nitrided titanium in order to investigate the effect of nitriding layer on fatigue limit. Main results obtained are as follows. (1) The fatigue limit of nitrided pure titanium is remarkably reduced because of enlargement of grain size at high heat treating temperature and high stress field created from the elastic interaction in the compound layer. (2) Further test using specimen which was removed nitrified layer gradually, were also conducted and it was found that by removing the compound layer the fatigue limit recovered as the level of basic material and rather increased by coming of a diffusion layer. Therefore it is concluded that the surface compound layer generated by nitriding treatment reduced the fatigue limit but diffusion layer increased it.

전기스피닝 공구의 삼분력 해석 (Analysis of three force components of shear spinning)

  • 최재찬;백남주
    • 대한기계학회논문집
    • /
    • 제5권2호
    • /
    • pp.88-93
    • /
    • 1981
  • The three force components of shear spinning are calculated by a newly proposed deformation model. The spinning process is understooed as shearing deformation arter uniaxial yuelding by ending, and shear stress .tau.$\sub$rz/ becomes .kappa. the yueld limit in pure shear, in the deformation zone. The tangential forces are calculated and then the feed forces and normal foeces are obtained by assuming a nuiform distribution of roller pressure on the contact surface. An optimum contact area is obtaned by minimizing the bending energy required to obtain the assumed deformation mechanism. The calculated forces are compared with experimental data form published literature and present experiments. Good agreement cetween calculated and experimental values for working forces is obtained over a wide range of process variables.