Investigation on the flexural behaviour of ferrocement pipes and roof panels subjected to bending moment |
Alnuaimi, A.S.
(Civil and Architectural Engineering Department, College of Engineering, Sultan Qaboos University)
Hago, A.W. (Civil and Architectural Engineering Department, College of Engineering, Sultan Qaboos University) Al-Jabri, K.S. (Civil and Architectural Engineering Department, College of Engineering, Sultan Qaboos University) Al-Saidy, A.H. (Civil and Architectural Engineering Department, College of Engineering, Sultan Qaboos University) |
1 | Al-Kubaisy, M.A. and Jumaat M.Z. (2000), "Flexural behaviour of reinforced concrete slabs with ferrocement tension zone cover", Construct. Build. Mater., 14(5), 245-252 DOI ScienceOn |
2 | Mansur, M.A., Ahmed I. and Paramasivam, P. (2001), "Punching shear strength of simply supported ferrocement slabs", J. Mater. Civil Eng., 13(6), 418-426 DOI ScienceOn |
3 | Mansur, M.A. and Paramasivam, P. (1985), "Cracking behaviour and ultimate strength of ferrocement in flexure", Proceedings of the Second International Symposium on Ferrocement, Bangkok, Thailand, 47-59 |
4 | Mathews, M.S., Sudhakumar, J., Sheela, S. and Seetharaman, P.R. (1991), "Analytical and experimental investigations of hollow ferrocement roofing units", J. Ferrocement, 21(1), 1-14 |
5 | Masood, A., Arif, M., Akhtar, S. and Haquie, M. (2003), "Performance of ferrocement panels in different environments", Cement Concrete Res., 33(4), 555-562 DOI ScienceOn |
6 | Memon, N.A., Sumadi, S.R. and Ramli, M. (2007), "Performance of high workability slag-cement mortar for ferrocement", Build. Environ., 42(7), 2710-2717 DOI ScienceOn |
7 | Moita, G.F., Las Casas, E.B. and Carrasco, E.V.M. (2003), "Experimental and numerical analysis of large ferrocement water tanks", Cement Concrete Compos., 25(1), 243-251 ScienceOn |
8 | Paramasivam, P., Lim, C.T.E. and Ong, K.C.G. (1998), "Strengthening of RC beams with ferrocement laminates", Cement Concrete Compos., 20(1), 53-65 DOI ScienceOn |
9 | Sander, J., Kacprzyk, B. and Kacprzyk, Z. (1985), "Ferrocement covers for district heating pipes", J. Ferrocement, 15(4), 343-347 ScienceOn |
10 | Shannag, M.J. (2008), "Bending behaviour of ferrocement plates in sodium and magnesium sulphates solutions",Cement Concrete Compos., 30(7), 597-602 DOI ScienceOn |
11 | Shui, L.T. (1989), "Ferrocement pipes for subsurface drainage", J. Ferrocement, 19(1), 29-35 ScienceOn |
12 | Silva, A.R.C., Proenca, S.P.B., Billardon, R. and Hild, F. (2004), "Probabilistic approach to predict cracking in lightly reinforced microconcrete panels", J. Eng. Mech., 130(8), 931-941 DOI ScienceOn |
13 | Wei, Z. (1985), "A research on glass-fibre reinforced plastic Ferrocement (GRPF) and its application in irrigation engineering", J. Ferrocement, 15(4), 359-364 ScienceOn |
14 | Yen, T. and Su, C.F. (1980), "Influence of skeletal steel on the flexural behaviour of ferrocement", J.Ferrocement, 10(3), 177-188 |
15 | Abdullah and Takiguchi K. (2003), "An investigation into the behaviour and strength of reinforced concrete columns strengthened with ferrocement jackets", Cement Concrete Compos., 25(2), 233-242 DOI ScienceOn |
16 | ACI Committee 549 (1997), State-of-Art Report on ferrocement, American Concrete Institute, ACI-R97, Manualof Concrete Practice, p. 26, Farmington Hills, MI, 48333-9094, USA |
17 | ACI Committee 549 (1993), Guide for Design, Construction and Repair of Ferrocement ACI 549 IR-93, Manual of Concrete Practice, p. 27, American Concrete Institute, Farmington Hills, MI, 48333-9094, USA |
18 | Al-Sulaimani, G.J. and Ahmad, S.F. (1988), "Deflection and flexural rigidity of Ferrocement I and Box beam", J.Ferrocement, 18(1), 1-12 ScienceOn |
19 | ASTM-C33 (1987), "Specification for concrete aggregate", USA |
20 | British Standard 12 (1996), Specification for Portland Cement, British Standard Institution, 389Chiswick High Road, London, W4 4AL BSI London, UK |
21 | Hago, A.W., Al-Jabri, K.S., Al-Nuaimi, A.S., Al-Moqbali, H. and Al-Kubaisy, M.A. (2005), "Ultimate and service behaviour of ferrocement roof slab panels", Construct. Build. Mater., 19(1), 31-37 DOI ScienceOn |
22 | British Standard 5911: Part 100 1989, Specification for Precast Concrete Pipes, Ancillary and Products, British Standard Institution, 389Chiswick High Road, London, W4 4AL |
23 | Duggal, S.K. (1998), "Bamboo ferrocement water supply pipes", Indian Concrete J., 72(8), 413-416 ScienceOn |
24 | Greepala, V. and Nimityongskul, P. (2008), "Structural integrity of ferrocement panels exposed to fire", Cement Concrete Compos., 30(5), 419-430 ScienceOn |
25 | Hauch Soren and Yong Bai (1999), "Bending moment capacity of pipes", Offshore Mechanical and Arctic Engineering, July 11-16, 3 |
26 | Iorns, M.E. (1989), "OTEC seawater pipe cost comparisons", Proc. of the First International Conference on Ocean Energy Recovery ICOER'89, Honolulu, Hawaii, 28-30 November, 297-306 |
27 | Ismail, M.S. and Waliuddin, A.M. (1996), "Network ferrocement drainage system", J. Ferrocement, 26(2), 113-119 ScienceOn |
28 | Kazemi, M.T. and Morshed, R. (2005), "Seismic shear strengthening of R/C columns with ferrocement jacket", Cement Concrete Compos., 27(7-8), 834-842 DOI ScienceOn |
29 | Kenai, S. and Brooks, J.J. (1994), "Tensile, flexural and impact behaviour of ferrocement with chicken wire mesh reinforcement", Proceedings of the Fifth International Symposium on Ferrocement, UMIST, Manchester, 342-355 |
30 | Kondraivendhan, B. and Pradhan, B. (2009), "Effect of ferrocement confinement on behaviour of concrete", Construct. Build. Mater., 23(3), 1218-1222 DOI ScienceOn |