• 제목/요약/키워드: pupil diameter

Search Result 37, Processing Time 0.022 seconds

Optical constant of the reduced eye based on theoretical finite model eye (이론적 정밀모형안에 기초한 환산모형안의 광학상수)

  • 김상기
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.268-273
    • /
    • 2004
  • A finite model eye based on longitudinal spherical aberration is designed by an optimization method. Longitudinal spherical aberration for pupil diameter between 1 mm and 8 mm is graphed theoretically and compared with other model eyes. The chromatic dispersions are adjusted to fit experimentally observed chromatic aberration of the eye. This is a finite model eye with four a spheric refracting surfaces. It has an effective focal length of 15.842 mm. A designed reduced eye has an equivalent power of 63.12 Diopter, curvature radius of 5.281 mm, index of 1.33333, and axial length of 21.123 mm.

PROTO-MODEL OF AN INFRARED WIDE-FIELD OFF-AXIS TELESCOPE

  • Kim, Sang-Hyuk;Pak, Soo-Jong;Chang, Seung-Hyuk;Kim, Geon-Hee;Yang, Sun-Choel;Kim, Myung-Sang;Lee, Sung-Ho;Lee, Han-Shin
    • Journal of The Korean Astronomical Society
    • /
    • v.43 no.5
    • /
    • pp.169-181
    • /
    • 2010
  • We develop a proto-model of an off-axis reflective telescope for infrared wide-field observations based on the design of Schwarzschild-Chang type telescope. With only two mirrors, this design achieves an entrance pupil diameter of 50 mm and an effective focal length of 100 mm. We can apply this design to a mid-infrared telescope with a field of view of $8^{\circ}{\times}8^{\circ}$. In spite of the substantial advantages of off-axis telescopes in the infrared compared to refractive or on-axis reflective telescopes, it is known to be difficult to align the mirrors in off-axis systems because of their asymmetric structures. Off-axis mirrors of our telescope are manufactured at the Korea Basic Science Institute (KBSI). We analyze the fabricated mirror surfaces by fitting polynomial functions to the measured data. We accomplish alignment of this two-mirror off-axis system using a ray tracing method. A simple imaging test is performed to compare a pinhole image with a simulated prediction.

Super-Resolution Iris Image Restoration using Single Image for Iris Recognition

  • Shin, Kwang-Yong;Kang, Byung-Jun;Park, Kang-Ryoung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.2
    • /
    • pp.117-137
    • /
    • 2010
  • Iris recognition is a biometric technique which uses unique iris patterns between the pupil and sclera. The advantage of iris recognition lies in high recognition accuracy; however, for good performance, it requires the diameter of the iris to be greater than 200 pixels in an input image. So, a conventional iris system uses a camera with a costly and bulky zoom lens. To overcome this problem, we propose a new method to restore a low resolution iris image into a high resolution image using a single image. This study has three novelties compared to previous works: (i) To obtain a high resolution iris image, we only use a single iris image. This can solve the problems of conventional restoration methods with multiple images, which need considerable processing time for image capturing and registration. (ii) By using bilinear interpolation and a constrained least squares (CLS) filter based on the degradation model, we obtain a high resolution iris image with high recognition performance at fast speed. (iii) We select the optimized parameters of the CLS filter and degradation model according to the zoom factor of the image in terms of recognition accuracy. Experimental results showed that the accuracy of iris recognition was enhanced using the proposed method.

Design of a See-through Off-Axis Head-Mounted-Display Optical System with an Ellipsoidal Surface

  • Wang, Junhua;Zhou, Qing;Chen, Jie;Hou, Lexin;Xu, Min
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.280-285
    • /
    • 2018
  • A new method to design a see-through off-axis head-mounted-display (OA-HMD) optical system with an ellipsoidal surface is proposed, in which a tilted ellipsoidal surface is used as the combiner, which yields the benefits of easier fabrication and testing compared to a freeform surface. Moreover, we realize a coaxial structure in the relay lens group, which is simple and has looser tolerance requirements, thus making assembly easier. The OA-HMD optical system we realize has a simple structure and consists of a combiner and 7 pieces of coaxial relay lenses. It has a $48^{\circ}{\times}36^{\circ}$ field of view (FOV) and 12-mm exit pupil diameter.

An Optical Design of Off-axis Four-mirror-anastigmatic Telescope for Remote Sensing

  • Li, Xing Long;Xu, Min;Ren, Xian Dong;Pei, Yun Tian
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.243-246
    • /
    • 2012
  • An off-axis four-mirror-anastigmatic telescope is presented here which is composed of two aspheric surfaces and two spherical surfaces. The entrance pupil diameter is 290 mm and the stop is located at the primary mirror. The effective focal length is 900 mm. The strip field of view for the telescope is $15^{\circ}{\times}0.2^{\circ}$ and if the telescope is launched into an orbit about 400 km altitude, the observed range width will be more than 105 km within a scene without any other auxiliary scanning instrument. The spectral range can be as wide as from visual wave band to infrared wave band in the mirror system. This telescope can be used for environmental monitoring with different detectors whose pixel is adapted to the optical resolution. In this paper, the spectral range is chosen as 3.0 -5.0 ${\mu}m$, and center distance of the pixel is 30 ${\mu}m$. And the image quality is near the diffraction limit.

Optomechanical Design and Structural Analysis of Linear Astigmatism Free - Three Mirror System Telescope for CubeSat and Unmanned Aerial Vehicle

  • Han, Jimin;Lee, Sunwoo;Park, Woojin;Moon, Bongkon;Kim, Geon Hee;Lee, Dae-Hee;Kim, Dae Wook;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.38.3-38.3
    • /
    • 2021
  • We are developing an optomechanical design of infrared telescope for the CubeSat and Unmanned Aerial Vehicle (UAV) which adapts the Linear Astigmatism Free- Three Mirror System in the confocal off-axis condition. The small entrance pupil (diameter of 40 mm) and the fast telescope (f-number of 1.9) can survey large areas. The telescope structure consists of three mirror modules and a sensor module, which are assembled on the base frame. The mirror structure has duplex layers to minimize a surface deformation and physical size of a mirror mount. All the optomechanical parts and three freeform mirrors are made from the same material, i.e., aluminum 6061-T6. The Coefficient of Thermal Expansion matching single material structure makes the imaging performance to be independent of the thermal expansion. We investigated structural characteristics against external loads through Finite Element Analysis. We confirmed the mirror surface distortion by the gravity and screw tightening, and the overall contraction/expansion following the external temperature environment change (from -30℃ to +30℃).

  • PDF

Optical Design and Tolerance Analysis for UVO-Multiband Polarizing Imager System

  • Han, Jimin;Chang, Seunghyuk;Park, Woojin;Lee, Sunwoo;Ahn, Hojae;Kim, Geon Hee;Lee, Dae-Hee;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.68.2-68.2
    • /
    • 2020
  • UVO-Multiband Polarizing Imager System (UVOMPIS) is an ultraviolet to visible light multi-wavelength polarization/imaging system for Compact Advanced Satellite. We developed Linear Astigmatism Free-Three Mirror System (LAF-TMS) D200F2 as an optical system of UVOMPIS which has an entrance pupil diameter of 200 mm, a focal ratio of 2, a field of view of 2° × 4°. LAF-TMS is a confocal off-axis reflecting telescope system that removes linear astigmatism, and its all mirrors (M1, M2, M3) are optimized with the freeform surface to reduce high-order aberrations. Through the sensitivity analysis and Monte-Carlo simulation as the tolerance analysis, we can confirm the feasibility of the system, relatively sensitive parameters (tilt, decenter, despace, surface RMS error), and considerations for optomechanical design. From the sensitivity analysis, we can discover the relatively sensitive optical alignment parameters to a single perturbation. Further more, in the monte-carlo simulation, we investigate the minimum tolerance budget satisfying the required optical performance and whether the tolerance range is satisfied within manufacturing error.

  • PDF

Anatomical and physiological changes in the aging eye (노인성 변화에 따른 안구와 해부생리학적 고찰)

  • Kim, Jai-Min;Seong, Jeong-Sub;Seo, Eun-Sun;Kho, Eun-Kyung;Lee, Seok-Ju;Yoo, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.135-143
    • /
    • 2004
  • The Human body is subject to two patterns of senescence, both of which are represented in the eye and vision. This article discusses the anatomical and physiological changes in anterior and posterior segments which occur with age. The areas covered include the globe, lids, tears, conjunctiva, cornea, sclera, anterior chamber angle, iris, lens, choroid, vitreous and retina. A sample of 219 individuals between the ages of 50 and 79 years was tested with case history, slit lamp examination, palpebral fissure, horizontal visible iris diameter(HVID) and pupil size. The palpebral fissure decreases with age while HVID remains constant in all age classes. This study suggests that an understanding of anatomical and physiological changes which occur with age is helpful to all eye clinicians because the aging process affects all of the ocular tissues.

  • PDF

Postoperative Contralateral Blepharoptosis in Patients with Unilateral Blepharoptosis and Negative Hering's Law Dependence Test (헤링씨 법칙 비의존성 단안성 윗눈꺼풀처짐증 환자에서 수술 후 생긴 건측의 눈꺼풀처짐증)

  • Ha, Won Ho;Lee, Yong Jig;Park, David Dae Hwan;Han, Dong Gil;Shim, Jeong Su
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.36-40
    • /
    • 2013
  • Background: Correction of unilateral blepharoptosis is unexpectedly difficult because healthy eye is often affected by Hering's law. Methods: We measured changes of marginal reflex distance (MRD1) on the unaffected eyelids between preoperative and 3-month postoperative photographs after ptosis correction. This study analyzed 134 unilateral blepharoptosis patients with ptosis correction from February 2002 to February 2011. Fifty patients among them were negative in Hering's law dependence test. From the preoperative and postoperative photographs the MRD1 of unaffected upper eyelids were measured and adjusted with the average pupil diameter of Koreans. Mean age was 34.4 and male was 30 and female was 20. Average follow-up periods were 14 months. Results: Thirteenth unaffected eyes (26%) showed decreased MRD1, and 3 patients (6%) showed decreased MRD1 value over 1.0 mm. Then 3 patients needed additional operations for correction of preoperatively unaffected but ptotic eyelids. Conclusion: There were no meaningful data statistically in the value of MRD1 in every unaffected eye of the patients and in the difference between preoperative and postoperative MRD1 of groups divided according to severity, causes, and types of operation.

Application of Topical Rocuronium Bromide Dosing by Ocular Size in Four Species of Wild Birds

  • Haerin Rhim;Sunjun Jung;Namsoo Kim;Jae-Ik Han
    • Journal of Veterinary Science
    • /
    • v.24 no.4
    • /
    • pp.59.1-59.13
    • /
    • 2023
  • Background: Rocuronium bromide has been evaluated as a mydriatic agent in birds, but the species applied were limited and the dose and effect were variable. Objective: This study aims to evaluate the efficacy of topical rocuronium bromide as mydriatics in 4 species according to horizontal palpebral fissure length: Feral pigeon (Columba livia), Common kestrel (Falco tinnunculus), Northern boobook (Ninox japonica), and Eurasian eagle owl (Bubo bubo). Methods: A total of 32 birds (8 for each species) were included as pre-releasing examination. Rocuronium bromide was instilled in one randomly selected eye of each bird based on palpebral fissure length criteria (0.5 mg/50 µL for pigeons, 1 mg/100 µL for kestrels and boobook owls, and 2 mg/200 µL for eagle owls). The contralateral eye was used as control and treated with normal saline. After instillation of the drug, pupil diameter, pupillary light reflex, intraocular pressure, heart rate, and respiratory rate were evaluated at 10 min intervals up to 180 min and at 30 min intervals up to 360 min. Results: Statistically significant mydriasis was obtained in all birds (p < 0.001). However, in boobook and eagle owls, marked mydriasis persisted until 360 min. Side effects including corneal erosion and lower eyelid paralysis were common, which was observed in 26/32 birds. Blepharospasm was also noted during this study. No systemic adverse signs were observed. Conclusions: Rocuronium bromide could be a good mydriatics option for 4 species of birds, however, further studies are needed to find lowest effective dose to reduce drug-related side effects.