• Title/Summary/Keyword: puncture test

Search Result 87, Processing Time 0.025 seconds

Changes of Texture, Soluble Solids and Protein during Cooking of Soybeans (콩의 조리과정 중 텍스쳐, 고형물 및 단백질의 변화)

  • Kim, Young-Ok;Jung, Hae-Ok;Rhee, Chong-Ouk
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.192-198
    • /
    • 1990
  • Texture, losses of total solids and proteins o) soybeans were studied during cooking at $100-135^{\circ}C$. The textural changes were measured using the puncture probe with an Instron Universal Testing Machine, and changes in microstructure of beans were observed with scanning electron microscopy during the cooking. The major effect observed was a breakdown of the cell walls and appearance of the protein bodies with soaking process. As the cooking time at $100^{\circ}C$ is longer, the separation of cells and changes in cell shape could be seen in the sample. The greater amounts of soluble solids were leached out with longer coo king time from the beans.

  • PDF

Single use Automatic Lancet to Minimize Pain During Skin Puncture (피부관통시 통증을 최소화하는 일회용 자동 모세혈액 채취기구)

  • 김현식;김경아;전명희;김태임;정용현;이태수;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.323-327
    • /
    • 2002
  • Chronic diabetic patients need to sample capillary blood for monitoring and controlling the blood sugar level. Frequent sampling requires to minimize pain during skin puncture. The present study developed mechanisms to minimize pain with effective sampling procedure. which consisted of tapered spring, guiding tunnel, and 30G needle Penetration depth was limited to within 2mm for pain reduction as well as for safety. Simple no-reuse mechanism also prevented the cross-patient and secondary infection possibility. Clinical experiments demonstrated the best convenience and safety with minimal pain in the diabetes, normal, and nursing students groups. Sing1e blood sampling was enough for successful blood sugar test by portable analyzer. The present sing1e use auto-lancet should be of great convenience in frequent capillary blood sampling for the diabetes.

Changes in Quality Attributes of Chang-pyung Yeot (taffy-like foods) with Storage Temperature (창평쌀엿의 저장온도에 따른 품질특성의 변화)

  • Rhee, Chong-Ouk;Park, Keun-Hyung;Seog, Ho-Moon
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.515-518
    • /
    • 1992
  • In order to find a critical temperature for keeping the quality of Chang-pyung yeot (one of the Korean traditional taffy-like rice foods), a sensory evaluation and a puncture test were done, and the changes in the appearance of cross section and the surface color were investigated for 10 day's storage. There was no change of quality at storage temperature below $10^{\circ}C$, but at storage temperature above $15^{\circ}C$, the quality of Chang-pyung yeot deteriorated with storage time. After storage for 1 week at temperature above $15^{\circ}C$, they sticked each other as results of structure deformation and melting, and sticked to teeth In mouth resulting in an offensive feeling. The estimated critical storage temperature of Chang-pyung yeot was $12{\sim}13^{\circ}C$.

  • PDF

Lumbar Puncture in Patients Who Experienced First Seizure with Fever (열이 동반된 첫 경련시의 뇌척수액검사)

  • Kim, Jung;Lee, Jun Su;Lee, Sang Eun;Choi, Wan Suk;Han, Sung Ryoung;Cho, Kyunglae
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.10
    • /
    • pp.1008-1012
    • /
    • 2003
  • Purpose : We aimed to ascertain whether lumbar punctures should be done to prove febrile seizure, and to study what conditions can delay or abolish lumbar puncture. Methods : This retrospective study was done for four years, from January, 1996 to December, 1999. The subjects were the patients who visited Masan Samsung Hospital for the first convulsion with fever, and whose age ranged from 1-month to 5-years old. The total number of patients was 197. We investigated the rate of meningitis, which was classified by age, season, convulsion type, associated symptoms, and results of blood test. All data were tested chi-square. Results : The diagnosis rate of meningitis among all 197 patients was 7.6%, and of these only one patient was proved to have bacterial meningitis. The rate was high in the young(below 6 month), in males and in summer and autumn. Although the general appearance was good after resolution of the fever, the rate of meningitis was 6.5%. Patients with nausea and vomiting totalled 11%; 9.1% of them were diagnosed with meningitis. The diagnosis rate of meningitis in cases in which additional seizures took place were 33.3%. Conclusion : The ultimate goal of lumbar punctures in seizure patients with accompanying fever is to rule out bacterial meningitis, which, has been demonstrated to be rare. So we think that lumbar puncture can be postponed by close observation of pediatrics specialists and skilled nurses.

The Effect of Percutaneous Multiple Puncture BCG Vaccination on PPD 1TU, 2TU and 5TU Tuberculin Skin Test (경피용 BCG 백신의 PPD 1TU, 2TU 및 5TU 결핵 피부반응 검사에 대한 영향)

  • Kim, Bo Sun;Hwang, Min Ho;Kim, Chang Hwi;Park, Jae Ok;Shin, Sang Man
    • Pediatric Infection and Vaccine
    • /
    • v.8 no.2
    • /
    • pp.175-180
    • /
    • 2001
  • Purpose : Recently in Korea since 1998, 2TU has been used instead of 5TU, which caused a confusion in interpreting tuberculin skin tests. We compared the tuberculin skin reaction to PPD(purified protein derivatives) 1TU, 2TU and 5TU. Methods : We studied tuberculin skin reaction to PPD 1TU, 2TU and 5TU on 92 infants who were vaccinated with percutaneous multiple puncture BCG vaccine(Tokyo 172 strain, Japan BCG Laboratory Co.) in neonatal period. Diameters of indurations were measured in millimeters 48~72 hours after the intradermal injection of PPD 1TU, 2TU and 5TU. Results : Among 92 infants(male : 56, female : 36), 1TU was used on 31 infants, 2TU on 31 infants and 5TU on 30 infants for tuberculin skin test. The mean diameter of induration for PPD 1TU, 2TU and 5TU were $5.7{\pm}4.2mm$, $7.1{\pm}3.7mm$, and $9.2{\pm}4.2mm$, respectively. There was no statistical difference in mean diameter of induration between 1TU and 2TU. However, when tested with 5TU, the diameter of induration was significantly larger than those of PPD 1TU and 2TU(P<0.05). Six subjects(19.4%) tested with 1TU, 9 subjects(29%) tested with 2TU and 16 subjects(53.3%) tested with 5TU had diameter of 10 mm or more. There was no statistical difference between 1TU and 2TU but for 5TU, number of subjects with diameter of 10 mm or more was significantly higher than PPD 1TU and 2TU(P<0.05). Number of subjects with induration diameter of 5 mm or more for 1TU, 2TU and 5TU was 19(61.3%), 22(71.0%) and 26(86.7%), respectively. However, there was no statistical difference. Conclusion : A new standard criteria for interpreting the tuberculin skin test with PPD 2TU should be established for clinical diagnosis of tuberculosis.

  • PDF

Clinical Investigation of Survey and Test in Korean Oriental Pediatrics (한방소아과 설문지 및 검사에 관한 임상현황연구)

  • Hwang, Young-Jun;Kim, Ki-Bong;Min, Sang-Yeon;Kim, Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.22 no.1
    • /
    • pp.25-34
    • /
    • 2008
  • Objectives The purpose of this study is to investigate whether Korean oriental pediatrics hospitals are using their feedback surveys to improve their medical conditions. Methods We selected 24 oriental medicine university hospitals and sent surveys to investigate. 15 of those surveys were analyzed. Results The results were classified as follows; Only 9 of university hospital said that they are currently using their feedback surveys to improve their services. Question for asking the purpose of doing their feedback surveys, 58.3% of hospital responded to get some information for diagnosis, 25% of them said to see the progress of treatment of specific disease, and 16.7% answered for using their data to the further studies. The question about the reason why hospital were need to make these feedback surveys, 46.2% of them answered to apply better service, 38.4% of them said to post medical journal. The question for asking what do oriental medical hospitals check from feedback surveys, 40% of them said they check Ryodoraku, 33.3% was pulse diagnostic apparatus, EAV(Electro-puncture According to Voll) was 26.7%. The classification according to purpose of test resulted as follows; information for diagnosis was 48.1%, the progress of a disease was 37.3%. In addition oriental medical test there were blood test, radiological test, brain waves test, Hair Tissue Mineral Analysis(HTMA), ultrasonic test, body composition analysis. Conclusions Further clinical research is necessary for improvement of using the feedback survey effectively.

  • PDF

Bone Healing Effect of a Magnet in Sprague Dawley Rats (Sprague Dawley 랫트에서 자장이 골 창상 치유에 미치는 영향)

  • Kim, Nam-Joong;Lee, Young-Won
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.2 s.95
    • /
    • pp.132-136
    • /
    • 2007
  • The present study was carried out to examine the bone healing effect of a magnet as the feasibility test for clinical application. The surgical technique of tibia puncture was performed with male Sprague Dawley rats for investigating radiological and histological findings. The treated group was attached the magnet, and control group was attached the placebo magnet for 4, 6, and 8 weeks respectively. The rats were taken a radiograph for examining radiological findings on 2-weekly interval for 8 weeks. Also, the rats were partly euthanized for investigating histological findings on 2-weekly interval from 4 week to 8 week. In the magnet treated rats, the healing process of bone trauma was positively stimulated to compare with control rats.

A Comparative Study of the Fasting Blood Sugar between Homeless and Aged People of Nursing Home in Daegu City, Korea - Comparision of National Health Insurance Coporation Criteria -

  • Shin, Hyun Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.3
    • /
    • pp.97-102
    • /
    • 2012
  • This study was performed to investigate the average fasting blood sugar levels from various Homeless and the old at nursing homes. Subjects (297 Homeless and 190 aged people) were examined in April, 2011 to June, 2010 in Daegu city area and only fasting blood sugar was measured. Subjects consist of 274 (56.30%) men and 213 (43.70%) women but primarily comprise over 60s. Blood was collected by vein-puncture, centrifuged and analyzed by TBA-C8000. The number of each subject for blood sugar levels of men groups were shown 197 (40.50%) with under 110, 24 (4.90%) with 110~125, and 53 (10.90%) with over 126. On the other hand, 127 (26.10%) with under 110, 33 (6.80%) with 110~125 and 53 (10.90%) with over 126 from women groups. This means that the average prevalence rate of diabetes is approximately 10% at each sex. Depending on age, the fasting blood sugar level over 126 increased with advancing age but the significance of results was not shown. Two groups, Homeless and aged people at nursing homes, the fasting blood sugar level was alittle high (2.9%) from Homeless but not significant. Regular blood sugar test and HbA1c test for people could be play an important role to prevent diabetic disorders under the government's interest.

  • PDF

A Study of Lightning Impulse Operating Duty and Temperature Dependence of Series Gap Type Arrester (Series Gap Type 피뢰기의 뇌임펄스 동작책무 및 온도의존성에 관한 연구)

  • Cho, Han-Goo;Yoo, Dae-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.659-664
    • /
    • 2009
  • This paper describes lightning impulse operating duty performance and temperature dependence of series gap type for transmission line arresters. The ageing parameters of lightning arresters are impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by lightning impulse current. In the discharge withstand test, total energy applied to the ZnO arrester each time is 4/10 ${\mu}s$, 30 kA. and in the operating duty test, the arrester has passed the test if thermal stability is achieved, if the residual voltage measured before and after the test is not changed by more than 5 %, and after the test reveals no evidence of puncture, flashover or cracking of the ZnO block. As a results, the residual voltage was in the range of 17.2${\sim}$20.3 kV and ZnO block bear up against at 2 shot of series impulse current of 30 kA. Also it was so excellent that the mechanical destruction does not occur at the 2 groups of 5 impulses current of 2/20 ${\mu}s$ 10 kA. According to the tests, it is thought that the ZnO arrester shows good stability with impulse current test. and it was found that the ambient temperature is increased resistive leakage current was increased in the range 47.3${\sim}$167.4 ${\mu}A$.

Development of Extra High Voltage(400kN) Porcelain Insulator for Transmission Lines (765 kV용 400 kN 현수애자 개발)

  • 최인혁;최장현;이동일;최연규
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.8
    • /
    • pp.348-353
    • /
    • 2003
  • This paper was the research of high voltage suspension insulator (400 [kN]) including pottery stone, feldspar, clay and alumina of 17 [wt%]. The slurry was fabricated after ball milling mixed raw materials. Green compacts were made by the extrusion of jiggering method and were sintered at 1300[$^{\circ}C$] for 50 [min.] in the tunnel kiln. The sintered density was reached to 97% of theoretical density, and the bending strength was 1658 [k $g_{f}$/$\textrm{cm}^2$] and hardness and fracture toughness which was measured by ICL( indentation crack length ) method were 1658 (kgf/$\textrm{cm}^2$) and 27.5 [Gpa], respectively. In measurement of tana and insulation break voltage of 400 (kN) porcelain, tan$\delta$ took some numerical value between 17${\times}$10$_{-3}$ and 61${\times}$10$_{-3}$ and insulation break voltage value was 19.9$\pm$1.4 [㎸/mm]. The test was performed to research whether the shape of pin affect a overvoltage break load or not As a consequence, when a pin was designed a pin diameter 51 [mm] with the bottom form of two-step constructed with straight in the suspension insulator, Insulator showed overvoltage break load 52 [ton] of the highest value and reflected a fine characteristic in aged deterioration test which is one of the accelerated aging test. Also it could be confirmed a fine characteristic through performing the test that electrical property of insulator was established correctly in accordance with IEC 60383-1 standards.s.