• Title/Summary/Keyword: pumping pressure

Search Result 343, Processing Time 0.026 seconds

Detachment of Vane Tip in a Positive Displacement Vane Pump (베인 이간 현상에 관한 연구)

  • 문호지;조명래;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.204-209
    • /
    • 1997
  • This paper reports on the theoretical study of the vane motions in a positive displacement vane pump. Vane detachment cause the pressure fluctuation, noise, wear in cam ring, and decrease the volumetric efficiency. Dynamic equation of vane motion and flow continuity equation have been modeled and solved simultaneously using 4th order Runge-Kutta method. As results of analysis, vane detachment occurs due to pressure overshoot by excess compression in the pumping chamber. Amount of vane detachment has been reduced by decreasing the pressure overshoot.

  • PDF

Characteristic Analysis of Spiral-Grooved Pump Seal (나선 홈 펌프 시일의 특성 해석)

  • Ha, Tae-Woong;Lee, An-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.799-804
    • /
    • 2002
  • In this paper the leakage prediction and rotordynamic analysis of an annular seal with a smooth rotor and spiral-grooved stator are performed. For developing a theoretical model, the three-control-volume analysis of the circumferentially-grooved seal is expanded by considering pressure reduction due to the pumping effect of spiral groove and pressure flow through the spiral groove. Results by the present analysis are compared with available experimental data. For leakage the analysis results generally show a reasonable agreement to the experimental results. For rotordynamic coefficients the analysis results show the same trend as the experimental results for rotor speed with spiral angles, but their magnitudes show somewhat large deviations.

  • PDF

Characteristic Analysis of Spiral-Grooved Pump Seal (나선 홈 펌프 시일의 특성 해석)

  • Ha, Tae-Woong;Lee, An-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.379.1-379
    • /
    • 2002
  • In this paper the leakage prediction and rotordynamic analysis of an annular seal with a smooth rotor and spiral-grooved stator are performed. For developing a theoretical model, the three-control-volume analysis of the circumferentially-grooved seal is expanded by considering pressure reduction due to the pumping effect of spiral groove and pressure flow through the spiral groove. Validation to the present analysis is achieved by comparisons with available experimental data. (omitted)

  • PDF

Effect of Vertical Clearance Between a Rotor and Stater of a Disk-Type Drag Pump on the Performance (원판형 드래그펌프 회전자와 고정자 사이의 간극이 성능에 미치는 영향)

  • Kwon, Myoung-Keun;Hwang, Young-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1501-1510
    • /
    • 2004
  • The pumping characteristics of a single-stage disk-type drag pump (DTDP) are calculated for the variation of the vertical clearance between a rotor and stator by the three-dimensional direct simulation Monte Carlo (DSMC) method. The gas flow mainly belongs to the molecular transition flow region. Spiral channels of a DTDP are cut on the both the upper and lower sides of a rotating disk, but a stationary disk is planar. The interaction between molecules is described by the variable hard-sphere model. The no time counter method is used as a collision sampling technique. The vertical clearance has a significant effect on the pumping performance. Experiments are performed under the outlet pressure range of 0.4∼533 Pa. When the numerical results are compared with the experimental data, the numerical results agree well quantitatively

분자 드래그 회전자 형상에 따른 복합분자펌프의 배기성능에 관한 실험적 연구

  • Hwang Yeong-Gyu;Gwon Myeong-Geun
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.05a
    • /
    • pp.202-205
    • /
    • 2006
  • Recently, high vacuum pumps are widely used in the semi-conduction and liquid-crystal display ( LCD ) process. The composite-type high vacuum pumps are widely used in the various processes. In this study, the pumping performance of composite-type molecular pumps has been investigated experimentally. The experimented pumps are a compound molecular pump ( CMP ) and hybrid molecular pump ( HMP ). The CMP consists with helical-type drag pump, at lower part, and with turbomolecular pump ( TMP ), at upper part. The HMP consists with disk-type drag pump, at lower part, and with TMP, at upper part. The experiments are performed in the outlet pressure of $0.2\;{\sim}\;533\;Pa$. We have measured the ultimate pressure, compression ratio, and pumping speed

  • PDF

MHD (Magnetohydrodynamic) Micropump Using Lorentz Force (로렌츠 힘을 이용한 MHD(Magnetohydrodynamic) 마이크로펌프)

  • 장재성;이승섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.11
    • /
    • pp.93-99
    • /
    • 1998
  • We present a novel micropump of which pumping mechanism is based upon MHD (Magnetohydrodynamic) principle. The MHD micropump uses Lorentz force as pumping source. In the MHD micropump, Lorentz force is applied into initially stagnant conducting fluid to drive it in magnetic and electric field to flow in both directions. The performance of the MHD micropump is obtained by measuring the pressure head difference and flow rate as applied voltage changes from 10 to 60 V DC at 0.19 and 0.44 Tesla. The pressure head difference is 18 mm at 38 mA and the flow rate is 63 ${\mu}{\ell}$ /min at 1.8 mA when the inside diameter of inlet/outlet tube is 2 mm and the magnetic flux density is 0.44 Tesla.

  • PDF

LUMPED PARAMETER MODELS OF CARDIOVASCULAR CIRCULATION IN NORMAL AND ARRHYTHMIA CASES

  • Jung, Eun-Ok;Lee, Wan-Ho
    • Journal of the Korean Mathematical Society
    • /
    • v.43 no.4
    • /
    • pp.885-897
    • /
    • 2006
  • A new mathematical model of pumping heart coupled to lumped compartments of blood circulation is presented. This lumped pulsatile cardiovascular model consists of eight compartments of the body that include pumping heart, the systemic circulation, and the pulmonary circulation. The governing equations for the pressure and volume in each vascular compartment are derived from the following equations: Ohm's law, conservation of volume, and the definition of compliances. The pumping heart is modeled by the time-dependent linear curves of compliances in the heart. We show that the numerical results in normal case are in agreement with corresponding data found in the literature. We extend the developed lumped model of circulation in normal case into a specific model for arrhythmia. These models provide valuable tools in examining and understanding cardiovascular diseases.

Numerical Analysis of the Flow Characteristics in the Nano Fountain-Pen Using Membrane Pumping (박막펌핑을 이용한 Nano Fountain-Pen의 유동 특성에 관한 수치적 연구)

  • Lee, J.H.;Lee, Y.K.;Lee, S.H.;Kim, Hun-Mo;Kim, Youn-J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.2 s.35
    • /
    • pp.19-24
    • /
    • 2006
  • Nano fountain-pen is a novel device to make the constant patterning in micro process using new designed probe. Fountain-pen nanolithography (FPN) is applied for constant supply of liquid in conjunction of patterns and surface variation in the micro process. In this study, nuo fountain-pen is composed with reservoir, micro channels, tip and scondary chamber. Instead of traditional method only using capillary force, liquid can be definitely and exactly injected with membrane pumping by the repulse force of tip. It is dfficult to perform experiments in the micro range so that we carried out a numerical analysis for internal flow, using a commercial code, FlUENT, The velocity, pressure and flow rate are obtained under laminar, unsteady, three-dimensional incompressible flow with no-slip condition, and results are graphically described.

Experimental Studies on Hydraulic Lifting of Solid-liquid Two-phase Flow

  • Park, Yong-Chan;Yoon, Chi-Ho;Lee, Dong-Kil;Kwon, Seok-Ki
    • Ocean and Polar Research
    • /
    • v.26 no.4
    • /
    • pp.647-653
    • /
    • 2004
  • Experimental studies with 4.3m and enlarged 30m in height have been conducted to investigate the flow characteristics of solid-liquid mixture in a lifting pipe and to acquire the design data for sea tests that will be performed in the future. From the results, it was observed that the more the discharged volume fraction and the solid diameter increase, the more the hydraulic gradient increases. Also, the more the diameter of the lifting pipe increases, the smaller the friction loss, and consequently, the less pressure drop and hydraulic gradient. From the enlarged hydraulic pumping experiments, it was shown that the results of the experiments were matched with those of the numerical model previously developed. On the bases of these studies, we plan to conduct further experiments and validate the hydraulic pumping model.

Design of the vacuum pumping system for the KSTAR NBI device (KSTAR 중성빔 입사(NBI) 장치 배기계통 설계)

  • 오병훈;인상렬;조용섭;김계령;최병호
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.548-555
    • /
    • 1999
  • The NBI (Neutral BGeam Injection) System for the Korea Superconducting Tokamak Advanced Research (KSTAR) is composed of ion sources, neutralizers, bending magnets, ion dumps, and calorimeter. The vacuum chamber, in which all of the beam line components are enclosed, is composed of differential pumping system for the effective transfer of the neutral beams. The needed pumping speeds of each of the divided vacuum chamber and the optimized gas flow rate ot the neutralizer were calculated with the help of the particle balance equations. The minimum gas flow rate to the ion sources for producing needed beam current (120kV, 65A, 78MW), the pressure distributions in the vacuum chamber for minimizing re-ionization loss, and the beam loss rate on the beam line components were used as the input in the calculation. Also the scenario for short pulse operation was determined by analysing the time dependent equations. It showed that beam extraction during less than 0.5 sec could be made only with TMP.

  • PDF