• Title/Summary/Keyword: pumping effect

Search Result 287, Processing Time 0.029 seconds

Analysis of Pumping Test Data and The Prediction of Drawdown for Daejong-Chun Area (대종천유역 충적대수층의 수리성 분석 및 수위강하예측에 관한 연구)

  • Choi, Jae-Jin;Sung, Won-Mo;Hahn, Jeong-Sang
    • Economic and Environmental Geology
    • /
    • v.26 no.4
    • /
    • pp.541-549
    • /
    • 1993
  • The main goal of this paper is to determine hydraulic properties and to predict drawdown for the efficient and stable development of groundwater in the Daejong-Chun area, North of Kyungsang-Do. Based on geological survey and analysis of well logging data conducted in 1991, it is found that the type of aquifer of this area is considered to be an anisotropic unconfined aquifer with saturated thickness of 19.8 m. In order to characterize this aquifer pumping test was conducted, and the resulting drawdown data were utilized for the analysis by applying both type curve matching technique and semi-log straight line method. As a result, the average specific yield of this aquifer is estimated as 32.3%, and the average ratio of $K_H$ to $K_V$ is only 2.7, which means that gravitational effect is not significant factor for this type of aquifer. For the validation of the estimated hydraulic properties, the analytical model which was developed with Newton-Raphson iteration procedure in this study, was employed to generate the drawdown. And, the resulting drawdown was compared against actual drawdown data and it shows the excellent matches. The actual drawdown data for 9 hours of pumping were used for history matching purposes and relatively satisfactory matches were achieved in this match. Then, the model was run by using the tuned parameters that are obtained during history matching stage, and the drawdown was predicted for the next 30 years of pumping with $3,000m^3/day$ of constant pumping rate. Its result indicates that the drawdown was stabilized as 1.41 m from 20 days with $3,000m^3/day$ of constant pumping rate, which is the required amount of water to be safely supplied to this area.

  • PDF

A Study on the Water Withdrawal Permit Rate and Monitoring Well Management of Bottled Water Manufacturers (먹는샘물 제조업체의 취수량 및 감시정 관리에 관한 고찰)

  • Son, Doo Gie;Park, Seunghyuk;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.329-337
    • /
    • 2019
  • Bottled water companies in Korea are required to conduct an environmental impact assessment of their drinking water supply at least six months before the expiration of their five-year marketing and production license. The water level drawdown, production well water quality, and monitoring well observation results are the most important items that are evaluated in the assessment report. Here we evaluate the relationship between well drawdown and pumping capacity with pumping time from the production wells of bottled water manufacturers located in Cretaceous granite (site A) and Precambrian gneiss (site B). The method to reduce the pumping capacity is more effective in decreasing the drawdown than the method to simultaneously control the pumping and recovery times. Furthermore, the monitoring data from the pH monitoring sensors that were installed in Precambrian gneiss (site C) yield pH values that increase with time and eventually plateau at a certain value. We therefore propose that pH monitoring is either discontinued or improved to provide more reliable and usable results.

Effects of the Application of Ankle Pumping Exercise and Elastic Compression Stockings for the Women's Lower Leg Edema due to Continuous Standing Work (장시간 서서 일하는 여성의 하지 부종에 대한 발목 펌핑운동과 탄력 압박스타킹 적용의 효과)

  • Hwang, Byung-Ha;Song, Si-Wook;Kim, Soo-Min
    • PNF and Movement
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • Purpose: This study was to identify the effects of the application of ankle pumping exercise versus elastic compression stockings for the women lower leg edema and pain due to continuous standing work. Methods: The participants were 20 women with leg edema and pain, divided into two group, 10 ankle exercise group and elastic compression stockings group. Low leg circumference were measured before and after work. Ankle pumping exercise group, elastic compression stockings were divided into groups, individual working one week during the arbitration to arbitration and work around the legs before and after retesting were compared before and after arbitration. Arbitration to stop and keep the information a week after the re-measurement of intervention before and after the arbitration and the degree of intervention were maintained. Statistical methods before and after working around the average value of each the legs was repeated measures ANOVA. Results: The participants had edema and leg problems because of their work. The ankle pumping exercise gorup and elastic compression stockings group showed statistically decrease in leg circumference value. there was no statistically value about the lasting effect of intervention after 1 week. Conclusion: The results of this study revealed that the application of elastic compression stockings and ankle pumping exercises during the hours of work is effective the relief of edema of lower extremity.

Spatial Assessment of Effects of Near-Stream Groundwater Pumping on Streamflow Depletion (하천변 지하수 양수로 인한 하천수 감소 영향의 공간적 평가 - 죽산천 유역을 중심으로 -)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il Moon;Lee, Min Ho
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.545-552
    • /
    • 2015
  • The objective of this study is to spatially assess the streamflow depletion due to groundwater pumping near the main stream of Juksanchoen watershed. The surface water and groundwater integrated model, SWAT-MODFLOW, in this study, was used to simulate streamflow responses to each groundwater pumping from wells located within 500m from the stream. The simulated results showed that the streamflow depletion rate divided by the pumping rate for each well location ranges from 20% to 96%. In particular, the streamflow depletion exceeds 60% of pumping rate if the distance between stream and well is lower than 100 m, hydraulic diffusivity is higher than $500m^2/d$, and streambed hydraulic conductance is above 25m/d. The simulated results were also presented in the form of spatial distribution maps that indicate the fraction of the well pumping rate in order to show the effect of a single well more comprehensively and easily. From the developed areal distribution of stream depletion, higher and more rapid responses to pumping occur near middle-downstream reach, and the spatially averaged percent depletion is about 66.7% for five years of pumping. The streamflow depletion map can provide objective information for the near-stream groundwater permission and management.

암반공압파쇄에 의한 지하수량 증대효과 분석

  • 김혜빈;부성안;이기철;김종태
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.47-50
    • /
    • 2003
  • We carried out rock pneumatic fracturing test which to increase groundwater yield by injection of highly pressured air in artificially under the surface every four borehole. The result of test performing shows that effect of increasing groundwater was not found in three testhole around igneous and metamorphic formation area, but we can realized that about 15 percent increased wateryield appeared in number P-5 test hole at sedimmentary rock formation.

  • PDF

Studies on Disintegration of Korean Old Corrugated Container(KOCC) Using a Pilot Screen (파일롯 스크린을 활용한 KOCC 해리 효율 연구)

  • Lee, Tai Ju;Nam, Yun Seok;Sim, Jae Min;Ryu, Jeong Yong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.48 no.3
    • /
    • pp.14-22
    • /
    • 2016
  • Pulping is a stage that can change fibrous raw materials into pumpable slurry. Recovered paper can be defibrated to individual fibers by shear stress generated by rotation of a rotor and water. Disintegration of recovered paper is more complicated than that of chemical pulp. When disintegration of recovered paper is poor, screening and cleaning efficiency will be worse and properties of paper will also be deteriorated. Therefore, pulping is an important treatment for improvement of availability of recovered paper and process runnability. In this study, degrees of disintegration of KOCC obtained from a linerboard mill was analyzed with a pilot-scale screen. Flake removal of KOCC slurry was performed by a pilot screen. Simple pumping action gave a positive effect on disintegration of KOCC. After pumping for 10 minutes, paper strength increased without the change of water retention value and fibrillation of KOCC slurry. This phenomena can be explained by modification of hornified surface of KOCC fibers by shear stress generated by pumping. Consequently, disintegration efficiency of KOCC can be enhanced by control of retention time at pulper or an agitation power at chests of papermaking process.

The Fabrication and Characteristic Experiment of a Heater-Trigger type High-Tc Superconducting Power Supply (히터트리거를 이용한 고온초전도전원장치의 제작 및 특성 실험에 관한 연구)

  • Yoon, Yong-Soo;Kim, Ho-Min;Chu, Yong;Lee, Chang-Yul;Ko, Tae-Kuk;Han, Tae-Su
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.9
    • /
    • pp.484-489
    • /
    • 1999
  • This paper deals with the design and fabrication of a heater-trigger type high-Tc superconducting power supply system, and characteristics have been analyzed through experiments. The high-Tc superconducting power supply consists of two heater trigger and electric magnet, and YBCO superconducting bulk. In this experiment, 0.6T class magnet and dc 2.3A heater current are used, and the current-pumping characteristics have been analyzed with computer aided sequence control system. Hall sensors are installed on the YBCO bulk and in the center of iron core in order to analyze the effect of the flux-pumping on the system with when magnet flux changes its value. In this experiment, maximum pumping-current has been achieved to about 6.6 amps.

  • PDF

Effect of groundwater level change on piled raft foundation in Ho Chi Minh City, Viet Nam using 3D-FEM

  • Kamol Amornfa;Ha T. Quang;Tran V. Tuan
    • Geomechanics and Engineering
    • /
    • v.32 no.4
    • /
    • pp.387-396
    • /
    • 2023
  • Ground subsidence, which is a current concern that affects piled raft foundations, has occurred at a high rate in Ho Chi Minh City, Viet Nam, due primarily to groundwater pumping for water supply. In this study, the groundwater level (GWL) change affect on a piled raft foundation was investigated based on the three-dimensional finite element method (3D-FEM) using the PLAXIS 3D software. The GWL change due to global groundwater pumping and dewatering were simulated in PLAXIS 3D based on the GWL reduction and consolidation. Settlement and the pile axial force of the piled raft foundation in Ho Chi Minh subsoil were investigated based on the actual design and the proposed optimal case. The actual design used the piled foundation concept, while the optimal case applied a pile spacing of 6D using a piled raft concept to reduce the number of piles, with little increased settlement. The results indicated that the settlement increased with the GWL reduction, caused by groundwater pumping and dewatering. The subsidence started to affect the piled raft foundation 2.5 years after construction for the actual design and after 3.4 years for the optimal case due to global groundwater pumping. The pile's axial force, which was affected by negative skin friction, increased during that time.

A study on Applicability of VacCAD Simulator

  • Kim, Hyung-Taek;Kim, Kang-Won
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.200-206
    • /
    • 2019
  • In this study, we compared the VacCAD and VacSim(Multi), commercial vacuum simulators, to verify the advantages of VacCAD's efficiency. It was emphasized on immediacy and simplicity of simulation modelling, and characteristics of the pump combinations, pumping down curves, and vacuum materials. First, usability of simulation mechanism was estimated through the modeling schematics and obtained simulation results of each employed simulator were compared to evaluate the applicability in practice. Simulation reliability of each simulator was also probed by comparing the pumping characteristics of commercially available high vacuum systems. In addition, the degree of tolerances on VacCAD was also investigated through pumping down analysis considering outgassing effect due to chamber material variations. The higher effectiveness and expediency of VacCAD than VacSim(Multi) has been presented, and it was expected that the utilization of VacCAD in vacuum applications to be increased.

A Study on the Discharge Pressure Ripple Characteristics of Variable Displacement Vane Pump (가변용량형 유압 베인펌프의 토출압력맥동 특성 연구)

  • 장주섭;김경훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.106-114
    • /
    • 2003
  • The pressure ripple in the delivery port is caused by flow ripple, which is induced by variation of pumping chamber volume. The other reason is the reverse flow from the outlet volume produced by pressure difference between pumping chamber and outlet volume, when the pumping chamber is connected with the outlet volume. In this study, a mathematical model is presented for analyzing discharge pressure ripple, which includes vane detachment, cam ring movement , and fluid inertia effects in V-groove in the side plate. From the analysis and experiment, it was found that V-groove on the side plate, coefficient of spring supporting the cam ring, and average discharge pressure are the main factors of discharge pressure ripple in variable displacement vane pump. The theoretical results, provided in this study, were well agreed with experimental results. The analytical model to estimate the magnitude of pressure ripple in this study is expected to be used f3r the optimal design of the variable displacement vane pump.