• Title/Summary/Keyword: pump energy

Search Result 1,443, Processing Time 0.028 seconds

Dynamic Spin Switching of Magnetic Films and Tunnel Junctions

  • Miyazaki, T.;Ando, Y.;Kubota, H.;Mizukami, Y.;Nakamura, H.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.272-273
    • /
    • 2003
  • Spin dynamics has been investigated intensively in various kinds of fields. Most popular one is an initial permeability at high frequency. Also, magnetic after-effect such as thermal fluctuation of fine magnetic particles and disaccommodation in soft magnetic materials were extensively studied in the past. When we apply an external farce with the same frequency as that of the system being examined, the system absorbs the external energy and the precession enhances. It is called resonance in general. Among the various resonances, ferromagnetic resonance (FMR) has been used as a good tool to evaluate material constants such as saturation manetization or spin damping parameter by analyzing a resonance curve. In this talk first instinctive understanding of Gilbert spin damping and spin pumping will be explained. Then, experimental data for enhancement of Gilbert damping parameter (G) evaluated from FMR spectrum and spin precession measured by a time resolved pump-probe method for Permalloy thin film will be introduced. Finally, magnetization reversal observed by air-coplanar probe will be given.

  • PDF

Assessing the Economic and $CO_2$ Emission Reductions Viability of Domestic Ground-Source Heat Pumps (단독주택용 지열 열펌프 시스템의 경제성과 이산화탄소 배출 저감 가능성 평가)

  • Sohn, Byong-Hu;Kang, Shin-Hyung
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.64-69
    • /
    • 2009
  • Because of their low operating and maintaining costs, ground-source heat pump(GSHP) systems are an increasingly popular choice for providing heating, cooling and water heating to public and commercial buildings. Despite these advantages and the growing awareness, GSHP systems to residential sectors have not been adopted in Korea until recently. A feasibility study of a residential GSHP system was therefore conducted using the traditional life cycle cost(LCC) analysis within the current electricity price framework and potential scenarios of that framework. As a result, when the current residential electricity costs for running the GSHP system are applied, the GSHP system has weak competitiveness to conventional HVAC systems considered. However, when the operating costs are calculated in the modified price frameworks of electricity, the residential GSHP system has the lower LCC than the existing cooling and heating equipments. The calculation results also show that the residential GSHP system has lower annual prime energy consumption and total greenhouse gas emissions than the alternative HVAC systems considered in this work.

  • PDF

Demonstration of EPRI CHECWORKS Code to Predict FAC Wear of Secondary System Pipings of a Nuclear Power Plant

  • Lee, Sung-Ho;Seong Jegarl;Chung, Han-Sub
    • Nuclear Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.375-384
    • /
    • 1999
  • The credibility of CHECWORKS FAC model analysis was evaluated for plant application in a model plant chosen for demonstration. The operation condition at each pipe component was defined before the wear rate analysis by plant data base, water chemistry analysis, and network flow analysis. The predicted wear was compared with the measured wear for 57 sample components selected from 43 susceptible line groups analysed. The inspected 57 locations represent components of highest predicted wear in each line group. Both absolute value and relative ranking comparisons indicated reasonable correlations between the predicted and the measured values. Four components showed much higher measured wear rates than the predicted ones in the feed water train from main feed water pump discharge to steam generator, probably due to high hydrazine concentration operation the effect of which had not been incorporated into the CHECWORKS model. The measured wear was higher than the predicted one consistently for components with least susceptibility to FAC. It is believed that the conservatism maintained during UT data analysis dominated the measurement accuracy. A great deal of enhancement is anticipated over the current plant pipe management program when a comprehensive plant pipe management program is implemented based on the model analysis.

  • PDF

Characterization of amplified spontaneous emission light source from an $Er^{3+}$/$Tm^{3+}$co-doped silica fiber ($Er^{3+}$$Tm^{3+}$이 복합 첨가된 실리카 광섬유의 ASE 광원에 대한 특성 평가)

  • Jeong, Hoon;Oh, K.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.96-97
    • /
    • 2000
  • Incoherent broadband optical sources have been applied in various areas such as a light source for optical device characterization, fiber-optic gyroscopes$^{(1)}$ , and spectrum sliced light source in wavelength division multiplexing (WDM) system$^{(2)}$ . To utilize the inherent low loss in silica optical fibers, various types of incoherent light sources are being developed. Among the light sources, the amplified spontaneous emission (ASE) from a rare earth doped fiber has benefits in temperature stability, high output power, low polarization dependence over semiconductor diodes$^{(3)}$ . Recently erbium doped fibers (EDF) have been intensively researched for ASE sources as well as optical amplifiers$^{(4)}$ . The spectrum of ASE from an EDF, however, is limited in the 1520~1560 nm range in conventional configurations. In this letter we described a new broadband ASE source which included both the conventional ASE band of Er$^{3+}$ ion, 1520nm~1560nm and ASE band from Tm$^{3+}$ ions that extends the bandwidth further. For the first time, to the best knowledge of authors, a fiber ASE source based on the energy transfer between Er$^{3+}$ and Tm$^{3+}$ ions in the range of 1460~1550 nm, has been demonstrated using a single 980nm pump laser diode. (omitted)omitted)

  • PDF

A Study about Applicability of Treatment for Backwash Water Using Tubular Membrane System with Dead-End Operation Mode (역세 배출수 처리를 위한 관형막의 전량여과 운전 적용에 대한 연구)

  • Eom, Jung Yeol;Kim, Kwan Yeop;Kim, Young Hoon;Song, June Sup;Kim, Hyung Soo;Han, Myung Ae;Yang, Hyung Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.437-444
    • /
    • 2008
  • Many other countries have investigated the new backwash water treatment process to save the existing water resource. There are various methods for reusing backwash water, but the membrane system has received the most interest for its efficiency. The objective of this study was to certify the application of membrane filtration system for the backwash water treatment. The experiment equipment was composed of Lab scale tubular membrane filtration system. Generally, cross-flow operation mode is used in the tubular membrane system but cross-flow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, dead-end operation mode was used in this experiment. Filtration and bleed operation cycle was used in this membrane system. Backwash water was concentrated during the filtration process and when backwash water reached our target suspended solid concentration, it was discharged from this system. For efficient operation of filtration and bleed, mathematical matrix was drawn up and with this matrix we could simulate various sets of filtration and bleed time.

MULTIDIMENSIONAL OPEN SYSTEM FOR VALVELESS PUMPING

  • JUNG, EUNOK;KIM, DO WAN;LEE, JONGGUL;LEE, WANHO
    • Bulletin of the Korean Mathematical Society
    • /
    • v.52 no.6
    • /
    • pp.1973-2000
    • /
    • 2015
  • In this study, we present a multidimensional open system for valveless pumping (VP). This system consists of an elastic tube connected to two open tanks filled with a fluid under gravity. The two-dimensional elastic tube model is constructed based on the immersed boundary method, and the tank model is governed by a system of ordinary differential equations based on the work-energy principle. The flows into and out of the elastic tube are modeled in terms of the source/sink patches inside the tube. The fluid dynamics of this system is generated by the periodic compress-and-release action applied to an asymmetric region of the elastic tube. We have developed an algorithm to couple these partial differential equations and ordinary differential equations using the pressure-flow relationship and the linearity of the discretized Navier-Stokes equations. We have observed the most important feature of VP, namely, the existence of a unidirectional net flow in the system. Our computations are focused on the factors that strongly influence the occurrence of unidirectional flows, for example, the frequency, compression duration, and location of pumping. Based on these investigations, some case studies are performed to observe the details of the ow features.

Hydraulic Modal Analysis of High-Pressure Common-rail Fuel Injection System for Passenger Vehicle (승용 CR 연료분사시스템에 대한 유압 Modal 분석)

  • Sung, Gisu;Kim, Sangmyeong;Kim, Jinsu;Lee, Jinwook
    • Journal of ILASS-Korea
    • /
    • v.20 no.1
    • /
    • pp.14-19
    • /
    • 2015
  • Recently, R&D demand for environmental friendly vehicle has rapidly increased due to its global environmental issues such as global warming, energy and economic crisis. Under this situation, the most realistic alternative way for environmental friendly vehicle is a clean diesel vehicle. The common-rail fuel injection system, as key technology of clean diesel vehicle, consists of a high pressure pump, common-rail, high pressure fuel line and electronic control injector. In common-rail high-pressure fuel injection system, high pressure wave of injection system and geometry of injector elements have a major effects on high-pressure fuel spray. Therefore, in this study, the numerical model was developed for analysis about the common-rail fuel pressure pulsation by using AMESim code. We could secure stability of common-rail high-pressure fuel injection system through optimal design of fuel line.

Emission Properties of Electrodeless Sulfur Lamp by Additives (화합물 첨가에 따른 무전극 황램프의 발광특성)

  • Lee, Jong-Chan;Kim, Kwang-Soo;Park, Dae-Hee;Hwang, Myung-Keun;Park, Cheol-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1890-1892
    • /
    • 2002
  • The technology of sulfur lamps that has physical and electrical characteristics comparable to current HID source has been reported. The fundamental principles of the operation of microwave discharges that are used to convert microwave energy to broad spectrum visual light are known. In this paper, emission dependance of microwave discharges in mixture content of sulfur with noble gases was studied. It is shown that the excitation of this gaseous mixture is carried out in two phases: (l) ionization of noble gas atoms by a microwave field and (2) the consequent maintenance of slightly ionized nonequilibrium plasma by the field. These two processes have essentially various thresholds for the microwave pump. The purpose of this work is to investigate spectral properties of the high frequency discharges in a mixture sulfur vapors with noble gases.

  • PDF

Performance Analysis of a Geothermal Heat Pump System Operated by a Diesel Engine (I) - Soil temperature prediction in Pusan and Chinju - (엔진구동 지열 열펌프의 성능 분석 (I) - 부산.진주지방 지중온도 예측 -)

  • 김영복
    • Journal of Biosystems Engineering
    • /
    • v.23 no.2
    • /
    • pp.135-146
    • /
    • 1998
  • The equation to predict the soil temprature of Pusan and Chinju city as a function of time and soil depth for the geothermal energy utilization system and agriculture was devised. The equation was $T(x,t)\;=\;Tm\;-\;To{\cdot}ExP(-{\xi}){\cdot}cos{{\omega}{\cdot}[t-to-x/(2{\cdot}{\alpha}{\cdot}{\omega})^{0.5}]}$ with the soil thermal diffusivity, ${\alpha},\;of\;0.4\;\textrm{m}^2/day,\;0.0375\;\textrm{m}^2/day$ and phase zero point, to, of 24 days, 22.4 days in Pusan and Chinju city, respectively, during ten years from 1987 to 1996. The predicted and measured soil temperatures agreed well with the coefficient of determination of 0.95 at the soil depth of 0.0, 0.5, 1.0, 3.0, 5.0 m. The maximum and minimum temperature in Pusan 3.7, $30.1^{\circ}C$ at soil surface and 14.3, $18.0^{\circ}C$ at the depth of 5.0 m. The total mean temperature of soil in Pusan and Chinju city was about 16.3, $16.0^{\circ}C$, respectively.

  • PDF

An Experimental Study on the Thermal Performance Measurement of Large Diameter Borehole Heat Exchanger(LD-BHE) for Tripe-U Pipes Spacer Apply (3중관용 스페이서를 적용한 대구경 지중열교환기의 성능측정에 관한 연구)

  • Lee, Sang-Hoon;Park, Jong-Woo;Lim, Kyoung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.581-586
    • /
    • 2009
  • Knowledge of ground thermal properties is most important for the proper design of large scale BHE(borehole heat exchanger) systems. The type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for insitu determination of design data for large diameter BHE for triple-U spacer apply. The main purpose has been to determine insitu values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a circulation pump, a inline heater, temperature sensors, flow meter, power analysis meter and a data logger for recording the temperature, fluid flow data. A constant heat power is injected into the borehole through the tripl-U pipes system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance of large diameter BHE for spacer apply.

  • PDF