• Title/Summary/Keyword: pulsed wave

Search Result 179, Processing Time 0.036 seconds

Comparison between Moxibustion and the Intense Pulsed Light (IPL) and the Clinical Application of Photo-moxa (구법(灸法)과 intense pulsed light(IPL)의 특성 비교 및 광선구(光線灸)의 한방임상(韓方臨床) 활용(活用))

  • Jang, In-Soo;Sun, Seung-Ho;Nam, Dong-Hyun;Kum, Su-Eun;Seo, Hyung-Sik
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.23 no.3
    • /
    • pp.78-83
    • /
    • 2010
  • Objectives : The purpose of this study is to compare the principles between moxibustion and the 'Intense pulsed light (IPL)' and to investigate the clinical application of the photo-moxa for the Korean medicine fields. Methods : The characteristics of moxibustion, IPL, parabolic reflector moxa and the dermatology surgical use of moxibustion were reviewed in the literature. Results : IPL is one type of light treatments that is employed by radiating the short-pulse wave, which is transformed from the light of high intensity. There has been used parabolic reflector in Asia for more than 2,000 years, and this hand-held device used for moxibustion in traditional medicine. Moxibustion is one of the treatment tools in Korean medicine using the heat energy. The fluence or energy density of IPL in clinical circumstances is similar to parabolic reflector moxa of moxibustion. IPL and parabolic reflector moxa shared same treatment principle employing the heat energy. Therefore IPL could apply for many indications in Korean medicine as a moxibustion tool and acupuncture. Conclusions: IPL may be plausible to be a fascinate method in phototherapy of Korean medicine.

Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2015
  • We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

Shock Compresssion and Microparticles Acceleration using High Power Laser (고 출력 레이저 의한 충격파 현상 연구 및 응용)

  • Lee, Hyun-Hee;Yoh, Jai-Ick
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1916-1919
    • /
    • 2007
  • We have been setting up experiments on propagation of shock waves generated by the pulsed laser ablation. One side of a thin metal foil is subjected to laser ablation as a shock wave propagates through the foil. The shock wave, which penetrates through the foil is reflected by an acoustic impedance which causes the metal foil to high-strain rate deform. This short time physics is captured on an ICCD camera. The focus of our research is applying shock wave and deformation of the thin foil from the ablation to accelerating micro-particles to a very high speed.

  • PDF

Laser Supported Combustion Waves and Plasma Flows (고에너지펄스를 이용한 충격파 발생과 응용)

  • ;Choi, Ji-Hae;Gwak, Min-Cheol;Yoh, Jai-Ick
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.27-30
    • /
    • 2007
  • We have been setting up experiments on propagation of shock waves generated by the pulsed laser ablation. One side of a thin metal foil is subjected to laser ablation as a shock wave is generated from a localized spot of high intensity energy source. The resulting reactive shock wave, which penetrates through the foil is reflected by an acoustic impedance which causes the metal foil to high-strain rate deform. This short time physics is captured on an ICCD camera. The focus of our research is generating reactive shock wave and high strain rate deforming of thin metal foil for accelerating micro-particles to a very high speed on the orders of several thousand meter per second. Somce innovative applications of this device will be discussed.

  • PDF

Spray Angle and Break-up Characteristics of Supersonic Liquid Jets by an Impinging Methods with High Speed Projectile (초고속 발사체의 액체 저장부 충돌에 의한 초음속 액체 제트의 분무 속도 및 분열 특성)

  • Lee, In-Chul;Shin, Jeung-Hwan;Kim, Heuy-Dong;Koo, Ja-Ye
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.1
    • /
    • pp.55-60
    • /
    • 2011
  • Pulsed supersonic liquid jets injected into an ambient air are empirically studied by using a high pressure ballistic range system. Ballistic range systems which are configured with high-pressure tube, pump tube, launch tube and liquid storage nozzle. Experimental studies are conducted to use with various impact nozzle geometry. Supersonic liquid jets are generated by an impact of high speed of the projectile. High speed liquid jets are injected with M = 3.2 which pressure is 1.19 GPa. Multiple jets which accompany with shock wave and pressure wave in front of the jet were observed. The shock-wave affects significantly atomization process for each spray droplets. As decreasing orifice diameter, the averaged SMD of spray jets had the decreasing tendency.

Elastic modulus measurement of thin films using laser generated guided ultrasonic waves (레이저 초음파 기법을 이용한 박막 탄성계수 측정)

  • Cho, Seung Hyun;Heo, Taehoon;Ji, Bonggyu;Ahn, Bongyoung;Jang, Gang-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.550-554
    • /
    • 2014
  • Regarding thin films in MEMS/NEMS structures, the exact evaluation of mechanical properties is very essential to enhance the reliability of their design and manufacturing. However, such methods as a tensile test and a resonance test, general methods to measure elastic moduli, cannot be applied to thin films since its thickness is so small. This work concerns guided wave based elastic modulus measurement method. To this end, guided wave excitation and detection system using a pulsed laser and a laser interferometry has been established. Also an elastic modulus extraction algorithm from the measured guided wave signal was developed. Finally, it was applied to actual thin film structures such as Ni-Si and Al-Si multilayers. From experimental results, we confirm that the proposed method has considerable feasibility to measure elastic properties of thin films.

  • PDF

A Study of Mili-wave Pulse Accelerating For High Power Electron Beam (대 전력 전자빔 가속용 밀리파 펄스 연구)

  • Kim, Won-Sop;Kim, Jeong-Man;Kim, Yeong-Min
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1554-1555
    • /
    • 2006
  • We have studied the backward wave oscillator, a power pulsed generator oscillator at 20 GHz has higher frequency then current one. An absolute instability linear analysis was used for the purpose of designing the slow wave structure. A large diameter of the slow wave structure was adopted to prevent the breakdown brought about by the increase of power density.

  • PDF

Shock Wave Generation and its Applications by Pulsed Power (펄스파워를 이용한 수중 충격파 발생 및 응용)

  • Cho, Chu-Hyun;Lee, Hong-Sik;Choi, Young-Wook;Jo, Sung-Chan;Jung, Woo-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.190-191
    • /
    • 2007
  • Focused shock wave generation was tested under the water by the method of wire explosion. The wire was installed a focal point of the half ellipsoid, and the shock wave was focused on the other focal point. A numerous cavitations were observed in the path of the traveling shock wave and focal point by using high speed camera.

  • PDF

Stimulated Brillouin scattering in optical fiber for pulsed lights compared to continuous wave lights (광펄스신호와 연속광원을 이용한 광섬유내의 stimulated Brillouin scattering 비교 연구)

  • 이한협;최현범;이동한;남성현;김대연;윤형규
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.338-342
    • /
    • 2003
  • We have studied the properties of stimulated Brillouin scattering (SBS) in an optical fiber using optical pulses and continuous wave light. We find that the thresholds for SBS are the same when the averaged power of pulse light is the same as the power of cw light. From this result, the SBS threshold of pulse light can be deduced from that of continuous wave light, which can be obtained easily and accurately.

An Analysis of Photoacoustic Signals Excited by Excimer Pulsed Laser (엑시며 레이저 펄스에 의해 여기된 광음향신호 분석)

  • Yi, Chong-Ho;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.39-46
    • /
    • 1997
  • In this paper, the PA(PhotoAcoustic) signals excited in metals by Xef, KrF excimer laser pulse were detected by a PZT transducer, and its transforming machanism and directivity patterns were analysed. The laser energy density in irradiation spot divides the PA trasnsorming machanism to be classified into thermoelastic and plasma regime, and the transforming machanisms in two regimes are different from each other. Based on theoretical model, it is predicted that shear wave is greater than longitudinal in the thermoelastic regime and longitudinal is greater than shear wave by reaction force in plasma regime. These predictions were verified through experiments by using of the XeF excimer pulsed laser of 480nm center-wavelength and the KrF excimer pulsed laser of 248nm. Also, for its directivity pattern, an arrival angle of the maximum longitudinal energy was around $60^{\circ}$ and maximum shear energy was around $30^{\circ}$ in the thermoelastic regime, and an arrival angle of maximum longitudinal energy was shown on nomal to the surface and maximum shear energy was represented in about $30^{\circ}$ in plasma regime.

  • PDF