The Effects of Pain and Range of Motion by Continuous Wave Ultrasound and Pulsed Wave Ultrasound on Patient with Temporomandibular Joint Disability (측두하악관절장애 환자에서 연속초음파와 맥동초음파 적용이 통증과 관절가동범위에 미치는 효과)

  • Moon, Hyun-Ju;Seo, Hyun-Kyu;Gong, Won-Tae
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.1-11
    • /
    • 2007
  • Purpose: The purpose of this study was to determine the effect of continuous wave ultrasound and pulsed wave ultrasound that influence changes in pain and range of motion when applied to patients with temporomandibular joint disability. Methods: The subjects of the study were 40 selected patients who had been diagnosed with temporomandibular joint movement restriction and had endured pain for more than two weeks. These patients had visited K orthopedic surgery in Deagu measured from October 1, 2004 to March 31, 2005. The subjects were divided into two groups with 20 patients each. The one group was applied to continuous wave ultrasound and the other group was applied to pulsed wave ultrasound at a dosage of 1.5 W/$cm^2$ for a duration of 5 minutes and eight times for two weeks. The pain perception degree were measured by using Visual Analogue Scale(VAS) and the range of motion was measured by using a rule for each group. Results: The results obtained were as follows The change in the pain perception degree were statistically significant in both group(p<0.05) ; however, the continuous wave ultrasound group showed more difference in the average decrease in the pain perception degree than did the pulsed wave ultrasound group. Both groups showed significant results regarding changed in the range of motion(p<0.05) ; Comparing the difference in the average of the range of motion between the two groups, came back from normal the range of motion of temporomandibular joint at the both groups. Conclusion : Based on the results of this study, we found that both groups showed decreased pain and increased the range of motion, but the continuous wave ultrasound method had a higher therapy effect pain and the range of motion than the pulsed wave ultrasound method to patients with temporomandibular joint disability. With such finding, we expect that according to ultrasound therapy applicant method can be helped usable accurately to patients with variety symptoms temporomandibular joint disability.

  • PDF

Developement of Efficient Algorithm to Eliminate Aliasing of Ultrasonic Pulsed Wave Doppler Signal (초음파 Pulsed Wave 도플러 신호의 Aliasing 제거를 위한 효율적인 알고리즘 개발)

  • Kim, G.D.;Hwang, J.S.;Ahn, Y.B.;Song, T.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.213-214
    • /
    • 1998
  • The important role of the ultrasonic Doppler system in the modem clinical medicine is to provide the clinical information of the vascular system. The ultrasonic pulsed wave(PW) Doppler system, a kind of the ultrasound Doppler system, is more available than the ultrasonic continuous wave(CW) Doppler system because it can evaluate the velocity and the direction of blood flow as well as the depth of vessel. However, the ultrasonic PW Doppler system has the disadvantage that the range of evaluating velocity of blood flow is limited(Nyquist limit). In order to solve this limit, we propose the algorithm for eliminating this aliasing in this paper. In addition, we propose the efficient signal processing algorithm.

  • PDF

A Comparative Analysis of Step and Touch Voltages Depending on Two Test Voltage Waveforms

  • Jung, Kwang-Seok;Cha, Sang-Wook;Park, Dae-Won;Kil, Gyung-Suk;Oh, Jae-Geun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.4
    • /
    • pp.152-155
    • /
    • 2011
  • This paper presents a comparative analysis on step and the touch voltages generated by either a sine and a ring wave voltage generator; this analysis was done as a basic study in order to develop a small and lightweight ground meter. A ring wave generator using pulsed power technology was fabricated; an experimental grounding system specified in Institute of Electrical and Electronics Engineers standards 80 and 81 was installed. The step and the touch voltages, which were measured using comparable a sine and a ring waves in terms of magnitude and frequency, were equal. Using pulsed power technology, the weight of the fabricated ring wave generator could be reduced to one-fifth of that of a sine wave generator. Consequently, if a ground meter adopts the ring wave instead of a sine wave, it will be possible to reduce the weight of a ground meter and improve the efficiency of measurement.

A Numerical Study on the Transmission of Thermo-Acoustic Wave Induced by Step Pulsed Heating in an Enclosure (제한공간내 펄스가열에 기인한 열음향파의 전달특성에 관한 수치적 연구)

  • 황인주;김윤제
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.914-922
    • /
    • 2002
  • Thermo-acoustic waves can be thermally generated in a compressible flow field by rapid heating and cooling, and chemical reaction near the boundary walls. This mechanism is very important in the space environment in which natural convection does not exist. Also this may be a significant factor for heat transfer when the fluids are close to the thermodynamic critical point. In this study, the generation and transmission characteristics of thermo-acoustic waves in an air-filled confined domain with two-step pulsed heating are studied numerically. The governing equations are discretized using control volume method, and are solved using PISO algorithm and second-order upwind scheme. For the purpose of stable solution, time step was set to the order of $1\times10_-9s,\;and\;grids\;are\;50\times2000$. Results show that temperature and pressure distributions of fluid near the boundary wall subjected to a rapid heating are increased abruptly, and the induced thermo-acoustic wave propagates through the fluid until it decays due to viscous and heat dissipation. Pressure waves have sharp front shape and decay with a long tail in the case of step heating, but these waves have sharp pin shape in the case of pulsed heating.

Fast Measurement using Wave-Cutoff Method

  • Seo, Sang-Hun;Na, Byeong-Geun;Yu, Gwang-Ho;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

Discharge characteristics of FFL as applied voltage variation (인가 전압의 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성)

  • 윤성현;박철현;조민정;임민수;권순석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.379-382
    • /
    • 2000
  • The characteristics of Xe discharge lamp(Mercuryless lamp) are described in this paper. In this paper, FFL is operated by sine wave and pulsed source. We apply V-Q Lissajous' figure for the discharge measurements of FFL which has the electrodes covered with dielectric. When FFL is operated by sine wave source, the characteristics are similar to DBD(Dielectric Barrier Discharge) and SD(Silent Discharge). And we compared the characteristics of FFL which is operated with sine wave and pulsed discharge by using V-Q Lissajous' figure method. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. As the duty ratio increases the electric field becomes strong and much more xenon ions are produced. And the number of metastable xenon atoms seem to increase, therefore, the phosphor radiation after the cut off of voltage increases compared with the first peak of radiation. Consequently, the 172㎚ radiation becomes strong as the duty ratio increases.

  • PDF

Fabrication and Identification of Marx Generator for the Design of High Power Backward Wave Oscillator (대 전력 후진파 발진기의 설계를 위한 마르크스 발생기의 제작 및 검증)

  • Kim, Won-Seop;Hwang, Nak-Hun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.391-399
    • /
    • 1999
  • We have designed the backward wave oscillator, a power-pulsed generator oscillated at 20 GHz has higher frequency than current one. An absolute instability linear analysis was used for the purpose of designing the slow wave structure. A large diameter (D/$\lambda$=4.8) of the slow wave structure was adopted to prevent the breakdown brought about by the increase of power density. We have fabricated a marx generator, pulse forming line and diode. And the development of a compact pulsed power generator with short period and low amplitude is expected.

  • PDF

Process Optimization for the Laser Cutting of Cold Rolled STS Sheet (냉연 스테인리스강판의 레이저 절단 특성)

  • 이기호;김기철
    • Journal of Welding and Joining
    • /
    • v.14 no.5
    • /
    • pp.59-68
    • /
    • 1996
  • This study was aimed to characterize the laser cutting process for the cold rolled stainless steel sheet. The principal process parameters of the cutting process were applied to both the continuous wave form and the pulsed wave form for the laser output mode. The laser-oxygen cutting process and the laser-nitrogen cutting process were also considered to characterize the quality and efficiency of the cutting process. The laser-oxygen cutting process revealed the better productivity than the laser-nitrogen cutting process, since the laser energy and the exothermic oxidation energy exerted on the laser-oxygen cutting process simultaneously during the entire cutting process. However, the straightness of the cutting section, which was considered as the most important factors, was inferior to that of the laser-nitrogen cutting process due to the formation of chromum oxide on the cutting surface. Frequency and duration of the pulsed wave form act as the main factors for the better quality, When the frequency increased from 100 Hz to 200 Hz and the duty increased from 20% to 40%, the quality factors such as the height of dross and the surface roughness were improved remarkably. The increase in the frequency from 200 Hz to 300 Hz, on the other hand, revealed the less effective in the cutting quality.

  • PDF

Effects of chemical restraint drugs on Doppler echocardiography in normal dogs (화학적 보정약이 정상견의 도플러 심초음파에 미치는 영향)

  • Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.2
    • /
    • pp.413-418
    • /
    • 1998
  • Intracardiac velocities were determined and the wave-forms described for 4 flow areas of the normal canine heart following administration of chemical restraint drugs including xylazine HCl, ketamine HCl, and thiopental sodium using pulsed wave Doppler echocardiography. The result was that xylazine HCl and thiopental sodium reduced intracardiac flow velocities through mitral, tricuspid, aortic and pulmonary valves. It is also thought that precautions are required before using these drugs. Patterns of wave-forms had no changes between control and treatment groups. Doppler echocardiography allows the clinician to determine flow velocities across the different valves and within the various chambers of the heart. It is shown that establishing normal values and those related to chemical restraint administrations and knowing what influences them should allow the clinician to non-invasively diagnose a variety of pathological cardiac conditions.

  • PDF

A STUDY ON THE ORTHODONTIC TOOTH MOVEMENT UNDER HALF SINE-WAVE PULSED ELECTROMAGNETIC FIELDS (Half sine-wave pulsed electromagnetic fields 내에서 교정력에 의한 치아 이동에 대한 연구)

  • Kim, Young-Joon;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.24 no.4 s.47
    • /
    • pp.897-916
    • /
    • 1994
  • The biologic potential, which is different from the piezoelectric signals, relates tooth movement at least in part to changes in bone metaboliosm in bioelectric theory. The purpose of this experiment was to determine wheather the application of half sine-wave pulsed electromagnetic fields (HSPEMF) could increase both the rate and amount of orthodontic tooth movement. Forty-three male Hartley guinea pigs, weighting approximately 255g, were utilized in this study. The animals were 35 days old at the start of the study. Laterally directed orthodontic force was applied to the maxillary central incisors of 40 Hartley guinea pigs (20 experimental, 20 control). According to the amount of orthodontic force (6g, 12g), they were divided into two sub-groups (10 experimental I, 10 experimental II, 10 control I, 10 control II). During the experimental period, experimental animals were placed in plastic animal holders with their heads positioned in an area of uniform electromagnetic field. Control animals were placed in similar plastic holders that did not carry the electric apparatus. The results were as follows : 1. The application of a HSPEMF to the experimental groups significantly increase the final amount of orthodontic tooth movement observed over a 10-day experimental period. 2. The application of a HSPEMF to the experimental groups significantly increase the velocity of orthodontic tooth movement observed over a 10-day experimental period. 3. There was no significant difference in the final amount of orthodontic tooth movement at the fourth day to the eighth day, but there was significant difference in the final amount of orthodontic tooth movement at the nineth, tenth day during a 10-day experimental period. 4. After 10 days of HSPEMF exposure & orthodontic force, the experimental groups demonstrated more osteodasts in the pressure side than control groups.

  • PDF