• 제목/요약/키워드: pulsed generator

검색결과 102건 처리시간 0.038초

기체 레이저용 진공관식 펄스 전원 (A vacuum tube based pulse generator for gas lasers)

  • 진정태;차병헌;남성모;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.221-223
    • /
    • 2002
  • This paper describes a vacuum tube based high voltage pulse generator for pulsed gas lasers. The pulse generator delivers 20 kV, 300 A pulse outputs with more than 10 kHz pulse repetition rates It can be controlled its Pulse width from 30 ns to 80 ns continuously without any hardware change.

  • PDF

펄스 코로나 반응기에 대한 임피던스 분석 (A Study of Impedance Analysis for Pulsed Plasma Reactor)

  • 최영욱;이홍식;임근희;김태희;김종화;장길홍;신완호;송영훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1601-1604
    • /
    • 1998
  • In this study, the impedance characteristic for wire-prate plused plasma reactor was analyzed by experiment. For this, rotary spark gap and MPC purse generator were used as power source. The reactor impedance decreases with increasing wire length and applied voltage. From this fundamental experiment, we deduced a method for the impedance matching between purse generator and pulsed plasma reactor.

  • PDF

기판바이어스 변화에 따른 반응성 마그네트론 스퍼터링에 의한 TiN 코팅 (TiN coatings by reactive magnetron sputtering under substrate bias)

  • 서평섭;한만근;박원근;전성용
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2008년도 추계학술대회 초록집
    • /
    • pp.45-46
    • /
    • 2008
  • Hard coatings of TiN which exhibit a large variation in their electrical resistivities, have been prepared in magnetron sputtering system using bipolar pulsed DC generator. TiN coatings have also been prepared using a DC generator in the same sputtering system under identical deposition conditions. Microstructural, Mechanical, Crystallographic properties of TiN films using continuous and bipolar pulsed DC generators were examined. Field emission scanning microscope and Nanoindenter have been used to characterize the coatings.

  • PDF

고압 고주파 펄스 파워 시스템을 이용한 세균 제거 특성 (The Characteristics on the Removal of Bacteria Using High Voltage and High Frequency Pulsed Power System)

  • 심지영;김미정;박제욱;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1416-1417
    • /
    • 2007
  • The high frequency pulsed power system is widely available for use in high frequency generator applications. We designed and fabricated our own high frequency pulsed power system to obtain very sort pulse width and high peak value and investigated microbe removal characteristics using it. This paper introduces a simple high voltage high frequency pulsed power system for removing various bacteria caused by dirty water. This system include power supply circuit, switching MOSFET, and flyback converter. We can also control the switching using a PIC one chip microprocessor. As a result, we can obtain good removing characteristics of various bacteria by adjusting the charging voltage, the pulse repetition rate and the electrical field inducing time.

  • PDF

침출수 처리 응용 펄스전원 시스템 (Pulsed Power System for Leachate Treatment Application)

  • 장성록;안석호;류홍제;임근희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.246-247
    • /
    • 2010
  • This paper deals with the water treatment of the leachate from sewage filled ground by a pulsed power technology. Leachate from sewage filled ground should be treated below regulation level of COD in order to prevent environmental pollution and usually treated by a chemical method. Among the pollutants mixed in the leachate, chemical compounds of benzene series are known to be difficult to break down, and need to use high cost treat methods. The treatment of the benzene compounds by high power pulsed power supply was studied. For the high-rate, cost-effective treatment of leachate, pulsed power supply should have high repetition rates and require switching devices of long lifetime. In order to meet the demands of the above condition, pulsed power generator based on semiconductor switches using IGBTs as primary switches were developed. The experimental results verified that benzene compounds can be treated effectively by high voltage electric pulses, and this fact indicates that the treatment method by pulsed power source is a promising substitute.

  • PDF

산업용 가속기용 고출력 펄스시스템의 설계와 시험 (Design and Test Results of High-Power Pulse Generator System for Industrial Accelerator Application)

  • 장성덕;김상훈;양해룡;조무현;고인수;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1370_1372
    • /
    • 2009
  • A conventional linear accelerator system requires a flat-topped pulse with less than $\pm$ 0.5% ripple to meet the beam energy spread requirements and to improve pulse efficiency of RF systems. A a line-type pulsed modulator is widely used in pulsed power circuits for applications such as accelerators, radar, medical radiation, or ionization systems. The high-voltage pulse generator system with an output voltage of 284 kV, a pulse width of $10{\mu}s$, and a rise time of $0.84{\mu}s$ has been designed and fabricated to drive a klystron which has 30-MW peak and 60-kW average RF output power. The high-voltage test was performed using the klystron load. This thesis describes the design and test results of high-power pulse generator system for industrial accelerator application. The experimental results were analyzed and compared with the design.

  • PDF

A New Generation of Biocompatible Pulse-discharged Plasma by Marx Generator and Its Application on the Biomolecules

  • 박지훈;;홍영준;;김상엽;김영조;이구협;이승목;박봉상;전수남;최은하
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.240.2-240.2
    • /
    • 2014
  • Characteristics of pulse-discharged plasma in liquid and its biological applications to proteins are investigated by making use of high voltage Marx generator. The Marx generator has been consisted of 5 stages, where each charging capacitor is $0.5{\mu}F$ to generate a high voltage pulse with rising time of $1{\mu}s$. We have applied an input voltage of 6 kV to the each capacitor of $0.5{\mu}F$. The high voltage pulsed plasma has been generated inside a polycarbonate tube by a single-shot operation, where the breakdown voltage is measured to be 7 kV, current of 1.2 kA, and pulse width of ${\sim}1{\mu}s$ between the two electrodes of anode-cathode made of stainless steel, which are immersed into the liquids. For the investigation of the influence of pulsed plasma on biomolcules, we have focused on the amino acids, DNA, proteins, cell and cholesterol.

  • PDF

저온 플라즈마 발생을 위한 ASM 방식의 펄스파워 발생장치에 관한 연구 (A Study on ASM Pulsed Power Generator for Non-thermal Plasma Applications)

  • 양천석;정용호;김한준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2035-2037
    • /
    • 1999
  • This paper describes an ASM(All Solid-state Modulator) pulsed power generator for non-thermal plasma applications. The proposed generator can produce 20kV, 500A, 100ns pulses at repetition rates up to 10kHz, and it is composed of 30 series connections of power circuit card assembly which contains paralleled MOSFETs, MOSFET drivers, energy storage capacitors and specially designed 1:1 pulse transformer. Higher pulse voltages and currents can easily be obtained by increasing the numbers of series and parallel connections of power circuit card and MOSFETs, respectively. Component layouts are optimized to minimize the leakage inductance and the voltage spikes across switching devices. Especially it put emphasis on the over-current protection (including short circuit) for the reliable operation in real situations. Experimental results show that the proposed pulser is very efficient in air pollution control application and could be useful for other applications such as synthesis of nanosize powders and non-thermal food processing.

  • PDF

펄스파워 시스템용 고전압 펄스변압기의 EMTP 시뮬레이션 (A EMTP Simulation of High-Voltage Pulse Transformer for Pulsed Power System)

  • 김민수;이형구;주홍진;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1984-1986
    • /
    • 2000
  • In pulsed-power techniques. Marx generator is generally used for the high-power device. but this generator has insulation and spatial problems. So we will suggest a pulse transformer that has a small size to generate the high voltage pulse instead of Marx generator. In this paper, Pulse duration is 4 [${\mu}s$] and the ratio of input and output voltage is 40[kV]/200[kV](step-up ratio=5). The output voltage and the process of pulse compression for pulse circuit are simulated by EMTP (Electro-Magnetic Transient Program). The secondary voltage of pulse transformer is about 200[kV] and pulse width is 4[t/s]. When the secondary winding of the pulse transformer is saturated. the pulse width is 1.25[${\mu}s$]. We selected dummy load 50[$\Omega$] for impedance matching. The pulse voltage of dummy load is 100[kV] and pulse width is 500[ns].

  • PDF

Neutronic design of pulsed neutron facility (PNF) for PGNAA studies of biological samples

  • Oh, Kyuhak
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.262-268
    • /
    • 2022
  • This paper introduces a novel concept of the pulsed neutron facility (PNF) for maximizing the production of the thermal neutrons and its application to medical use based on prompt gamma neutron activation analysis (PGNAA) using Monte Carlo simulations. The PNF consists of a compact D-T neutron generator, a graphite pile, and a detection system using Cadmium telluride (CdTe) detector arrays. The configuration of fuel pins in the graphite monolith and the design and materials for the moderating layer were studied to optimize the thermal neutron yields. Biological samples - normal and cancerous breast tissues - including chlorine, a trace element, were used to investigate the sensitivity of the characteristic γ-rays by neutron-trace material interactions and the detector responses of multiple particles. Around 90 % of neutrons emitted from a deuterium-tritium (D-T) neutron generator thermalized as they passed through the graphite stockpile. The thermal neutrons captured the chlorines in the samples, then the characteristic γ-rays with specific energy levels of 6.12, 7.80 and 8.58 MeV were emitted. Since the concentration of chlorine in the cancerous tissue is twice that in the normal tissue, the count ratio of the characteristic g-rays of the cancerous tissue over the normal tissue is approximately 2.