• Title/Summary/Keyword: pulsed corona discharge

Search Result 33, Processing Time 0.025 seconds

A High Efficiency Electrolytic Cell by Superposing Pulsed Corona Discharge in Water (수중 펄스코로나 방전을 중첩한 고효율 강전해수 발생장치)

  • 이재용;김진규;정성진;박승록;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.79-85
    • /
    • 2001
  • A conventional electrolyzing cell has been made by an ion exchange membrane inbetween parallel plate electrodes. A low dc voltage is applied to the electrodes for electrolyzing and the efficiency is remained in low. in this study, a novel electrolyzing cell with a pair of slit-type third electrodes installed inbetween parallel plate electrodes has been proposed and investigated experimentally. And pulse power wa supplied to between each electrodes. This slit type of third electrodes can concentrate the strong electric fields at the every its edges to accelerate the electrolyzing powers, and to generate oxygen bubble discharges for generating oxidants. And moreover the slits eliminate the space charge limiting action and the temperature of the water by leaking out through the slits from electrolyzing region to outside of the main electrode region. As a result, it was found that a strong electorzed water of pH 2.8 and pH 10.5 and oxidants dissolved water of 1 [ppm] in acidic water were obtained with a tap water fed at the electric current of 2 [A], which however were several times higher oxidant and ion concentration quantity compared with the conventional cell.

  • PDF

The first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures ($SF_6$ 기체와 $SF_{6}-N_{2}$ 혼합기체의 초기코로나 특성)

  • Lee, B.H,;Kim, J.I.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2002-2004
    • /
    • 2000
  • The discharge processes in electro-negative gases with non-uniform field gape are composed of the formation of pulsed streamer corona, the transition of the streamers into leader step, the temporal development of the leader channel, and the stepped propagation of leader through the gap. In this paper, the first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures, related to the propagation of loader and the space charge effect, were experimentally investigated with positive and negative transient impulse voltages.

  • PDF

Effect of Magnetic Field on NOX Removal for Wire-Plate Plasma Reactor (선대 평판형 플라즈마 반응기에서 NOX 제거에 미치는 자계의 영향)

  • Park, Jae-Yun;Go, Hui-Seok;Son, Seong-Do;Lee, Dong-Hun;Kim, Jong-Dal
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.120-124
    • /
    • 2000
  • In this paper, the effect of magnetic field was measured on NOx(NO+NO2) removal and consumption power for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx of the simulated diesel engine flue gas were removed by the corona discharge generated by DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with discharge voltage. However, when magnetic field was applied to electric field vertically, consumption power slightly decreased. NOx removal rate and arc transition voltage for plasma reactor with magnetic field were higher than those for plasma reactor without magnetic field. Consumption power decreased, however NOx removal significantly increased, when water vapour bubbled by dry air was put into simulated flue gas.

  • PDF

High Voltage Nano-Pulse Generator for Industrial Waste Water Treatment (폐수 처리용 고전압 나노 펄스 발생기)

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Kwon, O-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.311-318
    • /
    • 2001
  • The application of a pulsed power system is being extended to a environmental and industrial fields. The non-dissolution waste water pollutants from industrial plants can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The nano-pulse generator with a magnetic switch has been developed. Its corona current in load can be adjusted by pulse width and repetition rate. we investigated the performance of the nano-pulse generator using the dummy load which is composed of resistor and capacitor equivalent to the actual reactor. This paper descibes the electrical characteristics of the nano-pulse generator that produces a 300 ns pulse at maximum repetition rate of 400 pps with a voltage of 40 kV across a $640{\Omega}$ load. In this paper we briefly discuss a configuration of system and test results.

  • PDF

Effects of Operating Parameters on Phenol Degradation by Pulsed Corona Discharges in Aqueous Solutions (펄스 코로나 방전에 의한 페놀 분해에 미치는 운전변수의 영향)

  • Chung, Jae-Woo;Moon, Ji-Hoon;Park, Eun-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.79-86
    • /
    • 2010
  • Effects of operating parameters such as applied voltage, solution conductivity, ferrous ion concentration, electrode material on phenol degradation by pulsed corona discharges were investigated in laboratory scale experiments. The increase of applied voltage enhanced the phenol degradation by generating more energetic electrons. The solution conductivity inversely affected phenol removal rate in the tested ranges because the increase of conductivity decreased the electric field strength through the liquid phase. The addition of ferrous sulfate promoted the phenol degradation through the OH radical production by the Fentonlike reactions between ferrous ion and hydrogen peroxide generated by pulsed corona discharges. Catechol and hydroquinone were detected as primary intermediates of phenol degradation and the decrease of pH and the increase of conductivity were observed probably due to the generation of organic acids. Almost all of the initial phenol was disappeared and 29% of total organic corbon (TOC) was removed in the condition of 0.5 mM of ferrous sulfate after approximately 230 kJ of discharge energy transferred to the reactor.

Analysis of Impedance and Stray Inductance for Pulsed Plasma Reactor (펄스 플라스마 반응기에 대한 임피던스 및 누설 인덕턴스 분석)

  • Choi, Young-Wook;Lee, Hong-Sik;Rim, Geun-Hie;Kim, Tae-Hee;Kim, Jong-Wha;Jang, Gil-Hong;Shin, Wan-Ho;Song, Young-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.4
    • /
    • pp.253-260
    • /
    • 1999
  • In this paper, the impedance characteristic of wire-plate pulsed plasma reactor was investigated by experiment. The experiment have carried out under the several conditions of voltage, wire length and wire-plate distance. The impedance of reactor wad decreased with increasing voltage and wire length. The nature of discharge in reactor was changed from streamer corona to spark with increasing incident energy, from which we understood the critical energy density between the two discharges. Fromthis experiment, we proposed the method for the impedance matching between pulse generator and pulsed plasma reactor. Additionally, we succeeded in the analysis ofstray inductance of 0.5MW reactor using EMTP (ElectroMagnetic Transients Program). This means that EMTP is also useful for the analysis of inevitable stray inductance of forthcoming a large scale reactor.

  • PDF

Efficient Desulfurization and Denitrification by Low Temperature Plasma Process (저온 플라즈마 공정에 의한 효율적인 탈황 및 탈질)

  • Kim, Sung-Min;Kim, Dong-Joo;Kim, Kyo-Seon
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.129-135
    • /
    • 2005
  • In this study, we have analyzed the removal efficiencies of $SO_2$ and $SO_2/NO$ by the pulsed corona discharge process and investigated the effects of several process variables on those removal efficiencies systematically. The effects of process variables such as applied voltage, pulse frequency, residence time, and initial concentrations of reactants (NO, $SO_2$, $NH_3$, $H_2O$, and $O_2$) on the removal efficiency were analyzed. As the applied voltage, the pulse frequency or the residence time increases or as the $O_2$ or the $H_2O$ or the $NH_3$ concentration in the inlet feed gas stream increases, the $SO_2$ removal efficiencies and the simultaneous removal efficiencies of $SO_2/NO$ also increase. These experimental results can be used as a basis to design the pulsed corona discharge process to remove $NO_x$ and $SO_x$.

Effect of Magnetic Field on NOx Removal for Wire-Plate Plasma Reactor (선대 평판형 플라즈마 반응기에서 NOx 제거에 미치는 자계의 영향)

  • Park, J.Y.;Son, S.D.;Han, S.B.;Lee, D.H.;Kim, J.D.;Mun, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2251-2252
    • /
    • 1999
  • In this paper, the effect of magnetic field was measured on NOx removal characteristics for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx from simulated diesel engine flue gas are decomposed by the corona discharge of DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with increasing discharge voltage. When magnetic field was applied to electric field vertically, consumption power decreased. NOx removal rate and arc transition voltage of plasma reactor with magnetic field were higher than those of plasma reactor without magnetic field.

  • PDF

Air/Quartz Dielectric Double Barrier Pulse Discharge (공기/석영관(空氣/石英管) 복합유전체(複合誘電體)장벽층(障壁層)의 고주파(高周波) 펄스 방전(放電) 특성(特性))

  • Lee, Eung-Gwan;Woo, Jung-Uk;Chung, Suk-Hwan;Lee, Dong-Hoon;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1556-1558
    • /
    • 1994
  • An air/quartz dielectric double barrier pulse discharge has been investigated to develop a novel si lent type ozone generator. It is found that there are very active pulsed coronas occurred in the airgap which are very useful for ozone generation. And, the corona onset voltage of the airgap of the air/quartz double barrier was enfluenced greatly by the airgap of the air/quartz dielectric double barrier, and depended greatly upon the airgap ranged of $0.0{\sim}3.0mm$ and by the quartz tube thickness ranged of $1.75{\sim}2.25mm$.

  • PDF

A removal characteristics of NOx at the cylinderical plasma reactor with magnetic field (자계가 인가된 원통형 플라즈마 반응기에서 질소산화물(NOx)의 제거특성)

  • Lee, Dong-Hoon;Lee, Tae-Geun;Oh, Jung-Min;Lee, Doo-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.104-108
    • /
    • 2004
  • The effect of magnetic field was measured on NOx removal for cylinder-wire plasma reactor with magnetic field applied to electric field vertically. Power was supplied to plasma reactor using rotating spark gap switch. Consumption power increased with increasing discharge voltage. When magnetic field was applied to electric field vertically, consumption power was less than that without magnetic field because of lorenz's force. NOx removal rate of plasma reactor with magnetic field were higher, 10-15%, than that of plsama reactor without magnetic field. And NOx removal rate decreased with increasing gas flow rate.

  • PDF