• 제목/요약/키워드: pulse-width control

검색결과 805건 처리시간 0.029초

펄스형 Nd:YAG 레이저의 교번 충.방전 방식에 의한 고반복 동작특성 (The high repetition operating characteristics of pulsed Nd:YAG laser by alternating charge-discharge system)

  • 김휘영;박구렬;김병균;홍정환;강욱;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2204-2206
    • /
    • 1999
  • Pulsed Nd:YAC laser is used widely for materials processing and instrumentation. It is very important to control the laser energy density in materials processing by a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, the alternating charge-discharge system was designed to adjust a pulse repetition rate. This system is controlled by one chip microprocessor and allows to replace an expensive condenser for high frequency to a cheap condenser for low frequency. In addition. we have investigated the current pulse shape of flashlamp and the operating characteristics of a pulsed Nd:YAG laser. As a result, it is found that the laser output of the power supply using the alternating charge-discharge system is not less than that of typical power supply. As the pulse repetition rate rises from 30pps to 120pps by the step of 30pps at 1200V, it is found that the laser efficiency decreases but the laser output power increases about 6W at each step.

  • PDF

압력제어솔레노이드밸브를 이용한 직접구동 방식의 유압회로에 의한 자동변속기의 변속품질 향상에 관한 연구

  • 김정관;한명철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.577-580
    • /
    • 1995
  • This paper suggests direct-acting hydraulic circuit to control clutches and brakes in automatic transmission. As only one pressure control valve controls the pressure of several friction elements with accumulators in conventional hydraulic circuit, the controllable range is limited. In addition, it is difficult to control the fine timing between apply clutch and release clutch. So, we designed new method to control the pressure of clutch which uses ressure control valve and pressure control solenoid valve independently in each friction element. through this structure improvement of hydraulic circuit, we can control the pressure of clutches and brakes finely and fine timing of between apply clutch and release clutch.

  • PDF

고속 온-오프 전자 밸브를 사용한 유압 실린더의 압력 제어 (Pressure Control of Hydraulic Cylinder using high Speed On-Off Solenoid Valve)

  • 김상수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권1호
    • /
    • pp.69-78
    • /
    • 1999
  • In this study a new pattern of pressure control of hydraulic cylinder using high speed On-Off solenoid valve in the electro-hydraulic system has been suggested. The control valve is 3-way high speed On-Off solenoid valve which is operated by PWM(Pulse Width Modulation)control signal. The high speed On-Off solenoid valve has a tendency to induce severe pressure fluctuation in the hydraulic actuator so it has not been used for the purpose of closed loop control with direct pres-sure feedback. In this study closed loop control with direct pressure feedback is enabled by using a digital filter which has linear minimum mean square filter algorithm. Through some experiments it is confirmed that stable pressure control can be realized by the proposed control technique.

  • PDF

무선충전시스템의 충전 제어 방식 (Charging Control of Wireless Charging System)

  • 신한호;허준;전성즙
    • 전력전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.303-309
    • /
    • 2019
  • A hybrid control of a rectifier/regulator of wireless power transfer systems for electric vehicles is studied. A combined rectifier/regulator is used for charging control. The hybrid control comprises integral cycle control and pulse width modulation control to cope with the variations in the induced voltage due to clearance and alignment. The hybrid control has good control capability and does not cause severe switching loss. A 22 kW prototype of the Wireless Power Transfer class 4 charging system defined by the Society of Automotive Engineers is constructed and tested to verify the proposal.

가변 전압기와 역기전력 차동방식을 이용한 센서리스 BLDC 전동기 드라이버 설계 (Design of Sensorless BLDC Motor Driver Using Variable Voltage and Back-EMF Differential Line)

  • 이명석;공경철
    • 제어로봇시스템학회논문지
    • /
    • 제21권10호
    • /
    • pp.910-916
    • /
    • 2015
  • A sensorless motor control scheme with conventional back-Electro Motive Force (EMF) sensing based on zero crossing point (ZCP) detection has been widely used in various applications. However, there are several problems with the conventional method for effectively driving sensorless brushless motors. For example, a phase mismatch of 30 degrees occurs between the ZCP and commutation time. Additionally, most of the motor speed/current controls are achieved based on a pulse width modulation (PWM) method, which generates significant noise that distracts the back-EMF sensing. Due to the PWM switching, the ZCP is not deterministic, and thus the efficiency of the motor is reduced because the phase transition points become uncertain. Moreover, the motor driving performance is degraded at a low speed range due to the effect of PWM noise. To solve these problems, an improved back-EMF detection method based on a differential line method is proposed in this paper. In addition, the proposed sensorless BLDC driver addresses the problems by using a variable voltage driver generated from a buck converter. The variable voltage driver does not generate the PWM switching noise. Consequently, the proposed sensorless motor driver improves 1) the signal-to-noise ratio of back-EMF, 2) the operation range of a BLDC motor, and 3) the torque characteristics. The proposed sensorless motor driver is verified through simulations and experiments.

경피신경전기자극이 월경통 감소에 미치는 영향 (The Effect of Transcutaneous Electrical Nerve Stimulation on Dysmenorrhea)

  • 박래준;김기원
    • The Journal of Korean Physical Therapy
    • /
    • 제11권3호
    • /
    • pp.97-106
    • /
    • 1999
  • The purpose of this study was to examine the effect of transcutaneous electrical nerve stimulation(TENS) in the patients of dysmenorrhea. A total of thirty subjects were assigned randomly to one of the two experimental groups or to a control group : 1) an Experimental group I received high-frequency TENS(100pps with a 100-microsecond pluse width), 2) an Experimental group II received low-frequency TENS(2pps with a 100-microsecond pulse width), 3) a Control group received medication(Acetaminophen 600mg). All subjects completed visual analogue scale(VAS) pre-treatment; after post-treatment; 1, 2, 3, 4, and 6 hours post-treatment; and the next morning. The results of study were as follows; 1. The mean pain scores decreased in thru groups. 2. The experimental group II and the control group exhibited a significant decrease in pain post - treatment. 3. The experimental group I had the pain relief obtained after three hours post - treatment. The experimental group II had the pain relief obtained immediately after the post - treatment Control group had the pain relief obtained immediately after the post - treatment, but increased pain after four hours of post-treatment. Finally. this result suggests that TENS can reduce significantly the pain of dysmenorrhea. Besides. low-frequency TENS provided a good result to the excellent subjective pain relief in the subject, compared with high-frequency TENS and medication.

  • PDF

NTacSam:SD 골수 세포의 증식에 100Hz PWM 저출력 광 조사가 미치는 효과 (Effect of the 100Hz PWM Low Power Light Irradiation in Proliferation of NTacSam:SD Bone-marrow Cell)

  • 천민우;김성환;이호식;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집
    • /
    • pp.10-11
    • /
    • 2008
  • We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage. And then, each experiment was performed to irradiation group and non-irradiation group for bone marrow cells. MIT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590nm transmittance of ELISA reader. As a result, the cell increase of bone marrow cells was verified in irradiation group as compared to non-irradiation group.

  • PDF

Sliding Mode Attitude Control for Momentum-Biased Spacecraft

  • Bang, Hyo-Choong;Loh, Young-Hwan
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제3권2호
    • /
    • pp.13-23
    • /
    • 2002
  • In this paper, we present a sliding mode control strategy for the re-orientation maneuver of rigid spacecraft containing rotating wheels. The wheels are considered as internal devices, and external inputs are employed for generation of control commands. The formulation is developed for a general case while particular example is applied to pitch bias momentum spacecraft with a single momentum wheel. The resultant control commands are used to take the gyroscopic effects into account which are caused by the rotating wheels. The controller designed demonstrates that the nutational motion of the pitch bias momentum spacecraft is effectively controlled. It is also assumed that the external control torque device is of on-off nature, and pulse width modulation technique is applied to construct proper control torque history.

Control of Parallel Connected Three-Phase PWM Converters without Inter-Module Reactors

  • Jassim, Bassim M.H.;Zahawi, Bashar;Atkinson, David J.
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.116-122
    • /
    • 2015
  • This paper presents a new current sharing control strategy for parallel-connected, synchronised three-phase DC-AC converters employing space vector pulse width modulation (SVPWM) without current sharing reactors. Unlike conventional control methods, the proposed method breaks the paths of the circulating current by dividing the switching cycle evenly between parallel connected equally rated converters. Accordingly, any inter-module reactors or circulating current control will be redundant, leading to reductions in system costs, size, and control algorithm complexity. Each converter in the new scheme employs a synchronous dq current regulator that uses only local information to attain a desired converter current. A stability analysis of the current controller is included together with a simulation of the converter and load current waveforms. Experimental results from a 2.5kVA test rig are included to verify the proposed control method.

Unified MPPT Control Strategy for Z-Source Inverter Based Photovoltaic Power Conversion Systems

  • Thangaprakash, Sengodan
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.172-180
    • /
    • 2012
  • Z-source inverters (ZSI) are used to realize both DC voltage boost and DC-AC inversion in single stage with a reduced number of power switching devices. A traditional MPPT control algorithm provides a shoot-through interval which should be inserted in the switching waveforms of the inverter to output the maximum power to the Z-network. At this instant, the voltage across the Z-source capacitor is equal to the output voltage of a PV array at the maximum power point (MPP). The control of the Z-source capacitor voltage beyond the MPP voltage of a PV array is not facilitated in traditional MPPT algorithms. This paper presents a unified MPPT control algorithm to simultaneously achieve MPPT as well as Z-source capacitor voltage control. Development and implementation of the proposed algorithm and a comparison with traditional results are discussed. The effectiveness of the proposed unified MPPT control strategy is implemented in Matlab/Simulink software and verified by experimental results.