• Title/Summary/Keyword: pulse-like

Search Result 295, Processing Time 0.03 seconds

A Novel Multi-Quantum Well Injection Mode Diode And Its Application for the Implementation of Pulse-Mode Neural Circuits (다중 양자우물 주사형 다이오드와 펄스-모드 신경회로망 구현을 위한 그 응용)

  • Song Chung Kun
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.62-71
    • /
    • 1994
  • A novel semiconductor device is proposed to be used as a processing element for the implementation of pulse-mode neural networks which consists of alternating n' GaAs quantum wells and undoped AlGaAs barriers sandwitched between n' GaAs cathode and P' GaAs anode and in simple circuit in conjunction with a parallel capacitive and resistive load the trigger circuit generates neuron-like pulse train output mimicking the function of axon hillock of biological neuron. It showed the sigmoidal relationship between the frequency of the pulse-train and the applied input DC voltage. In conjunction with MQWIMD the various neural circuits are proposed especially a neural chip monolithically integrated with photodetectors in order to perfrom the pattern recognition.

  • PDF

Bipolar Pulse Bias Effects on the Properties of MgO Reactively Deposited by Inductively Coupled Plasma-Assisted Magnetron Sputtering

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • v.23 no.3
    • /
    • pp.145-150
    • /
    • 2014
  • MgO thin films were deposited by internal ICP-assisted reactive-magnetron sputtering with bipolar pulse bias on a substrate to suppress random arcs. Mg is reactively sputtered by a bipolar pulsed DC power of 100 kHz into ICP generated by a dielectrically shielded internal antenna. At a mass flow ratio of $Ar/O_2$ = 10 : 2 and an ICP/sputter power ratio of 1 : 1, optimal film properties were obtained (a powder-like crystal orientation distribution and a RMS surface roughness of approximately 0.42 nm). A bipolar pulse substrate bias at a proper frequency (~a few kHz) prevented random arc events. The crystalline preferred orientations varied between the (111), (200) and (220) orientations. By optimizing the plasma conditions, films having similar bulk crystallinity characteristics (JCPDS data) were successfully obtained.

Study on the origin and theoretical foundation of I Dong-won(李東垣)'s pulse diagnosis distinguishing internal and external injuries(內外傷辨脈法) (이동원(李東垣) 내외상변맥법(內外傷辨脈法)의 유래와 이론적 근거에 대한 고찰)

  • Jang, Woo-Chang
    • Journal of Korean Medical classics
    • /
    • v.20 no.2
    • /
    • pp.137-145
    • /
    • 2007
  • Pulse diagnosis that distinguishes internal injury from external injury by comparing the left and right of the chon pulse was formed in the process of Naegyoung's pulsation theory of ST9 and LU9 being assimilated into diagnostic method by taking chon pulse. The founder of school of internal injury, I Dong-won, expanded the horizon for this method to be widely used in clinical practice by especially explaining the specific application and theoretical background. According to him, pulse at ST9 which means chon pulse at the left hand, is bigger than the chon pulse at the right hand, it reflects external injury. Bigger "entrance pulse", a chon pulse at the right hand means internal injury. The reason is the left side of the body is a path for Yanggi so it controls the exterior part and the right side of the body is a path for Eumgi to descend so it controls the interior part. Internal injury develops as the spleen and stomach get injured. If the spleen and stomach is damaged essence derived from food cannot ascend to the stomach and will flow back to the lower part. As a result, fire of Eum type formed at the lower part will shoot up to the upper part and manifests external injury-like exterior syndromes. In this case, evidence distinguishing between internal and external injury is the fact that right hand pulse is bigger than the left hand. The important reason for distinguishing between internal and external injury is because when treating external injury caused by excess syndrome, pathogenic Gi should be dispelled. However, treating internal injury cased by deficiency syndrome, requires promoting the primordial Gi.

  • PDF

Prospects about Nuclear Electro Magnetic Pulse developed by North Korea (북한의 핵전자기파(NEMP)탄 개발에 대한 전망)

  • Lee, Dae Sung
    • Convergence Security Journal
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2017
  • The international community recognizes North Korea's nuclear and missile provocation as a real threat. This is due to the analysis and evaluation that has developed nuclear electro magnetic pulse of domestic and overseas North Korea experts, intelligence agencies related to electro magnetic pulse. Electro magnetic pulse experts are concerned about North Korea's nuclear electro magnetic pulse in the following aspects. First, industrial, military, medical, and living facilities in modern society are constructed with electrical and electronic systems. So, All electrical and electronic appliances will become neutralization if North Korea's nuclear electro magnetic pulse was set off over the world(i.e. Korean Peninsula, United States etc). Second, North Korea will judge that possibility of criticism by the international community is low from the point of view of an attacker. Because nuclear electro magnetic pulse aim to destroy only the electronic equipment of the opposite nation and cause damage rather than taking life. Finally, nuclear electro magnetic pulse is more threatening than weapons like mass destruction because it does not need to hit targets accurately and can strike a wide area with nuclear weapon of the low technology levels. In this respect, we will analyze and evaluate nuclear and missile development and make a prospects about nuclear electro magnetic pulse developed by North Korea.

Design of ECG/PPG Gating System in MRI Environment (MRI용 심전도/혈류 게이팅 시스템 설계)

  • Jang, Bong-Ryeol;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

On the improvement of inelastic displacement demands for near-fault ground motions considering various faulting mechanisms

  • Esfahanian, A.;Aghakouchak, A.A.
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.673-698
    • /
    • 2015
  • This paper investigates inelastic seismic demands of the normal component of near-fault pulse-like ground motions, which differ considerably from those of far-fault ground motions and also parallel component of near-fault ones. The results are utilized to improve the nonlinear static procedure (NSP) called Displacement Coefficient Method (DCM). 96 near-fault and 20 far-fault ground motions and the responses of various single degree of freedom (SDOF) systems constitute the dataset. Nonlinear Dynamic Analysis (NDA) is utilized as the benchmark for comparison with nonlinear static analysis results. Considerable influences of different faulting mechanisms are observed on inelastic seismic demands. The demands are functions of the strength ratio and also the pulse period to structural period ratio. Simple mathematical expressions are developed to consider the effects of near-fault motion and fault type on nonlinear responses. Modifications are presented for the DCM by introducing a near-fault modification factor, $C_N$. In locations, where the fault type is known, the modifications proposed in this paper help to obtain a more precise estimate of seismic demands in structures.

Estimation of PTT (Pulse Transit Time) by Multirate Filtering Analysis (다중레이트 필터링 기법을 이용한 맥파전달시간 추정)

  • Kim, Hyun-Tae;Kim, Jeong-Hwan;Kim, Kyeong-Seop;Lee, Jae-Ho;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1020-1026
    • /
    • 2013
  • Multirate filtering process on the biological signals like Electrocardiogram (ECG) and Photoplethysmogram (PPG) can be defined as the digital signal processing algorithm in which the sampling rate varies to omit or interpolate the intermediate values between the sampled data. With this aim, we suggest a new multirate filtering algorithm by deleting the extraneous data to eliminate the unwanted degradations such as granular noise due to the usage of high sampling frequency and simultaneously to detect the fiducial features of ECG and PPG with reducing the complexity of resolving fiducial points such as R-peak, Pulse peak and Pulse Transit Time (PTT). After the experimental simulations performed, we can conclude the fact that we can detect the fiducial features of ECG and PPG signal in terms of R-peak, Pulse peak and PTT without the loss of accuracy even if we do not maintain the original sampling frequency.

Study on the character of the old aged pulsation (고령자의 맥상 특성에 대한 맥파분석적인 연구)

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Ryu, Gyeong-Ho;Gang, Hui-Jeong;Cho, Sang-Won;Park, Young-Jae;Kim, Min-Yong;Oh, Hwan-Sup;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • Objectives: The basis research of aged people's healthcare technology is very important, because our nation goes into an aged society rapidly. Especially in traditional medicine, pulse shapes of aged people were supposed to weak and empty pulse until now, but any objective measurement and compare research do not taken. Methods and Results: Therefore in this study we design observation study to find characteristic of pulse between younger group (age $20{\sim}30$) and elder group (age $43{\sim}80$) in Busan area. We used 3-dimensional pulse analyzer '3-D MAC' (Daeyomedi Co., Ltd.). And major parameters for comparison are 1) pulse height (h1), 2) applied pressure, 3) pulse power (energy), 4) high pressure duration (w) and 5) R-AI. Conclusions: According to analysis result, elder people's pulse has more large value in pulse height, applied pressure and pulse power than younger's that. It reveals that elder people in modernized lifestyle has Yang symptoms as well Yin symptoms. Consequently we need new method to care elder people's health, and this means more important direction than old text book. From now on verification research with objective diagnosis device like 3-D MAC, must be activated to build of evidence in traditional medicine. Cause traditional medicine's spirit of care and prevention is suitable to care elder people's cardiac and cerebral vascular disease those are have close relation with elder people.

  • PDF

Study On The Same And Different Locations of Acupoints on Pulse (정경혈(正經穴) 중(中) 맥동처(脈動處)와 그 혈위(穴位)의 동이(同異)에 대(對)한 연구(硏究))

  • Jo, Hak-Jun;Lee, Pyeong-Jae
    • Journal of Korean Medical classics
    • /
    • v.20 no.4
    • /
    • pp.17-35
    • /
    • 2007
  • Objectives : To consider same or not the positions of acupoints on the meridian in the old acupuncture books. Methods: On the basis of old acu-books, We count the number of acupoints that are on pulse. Thru the three books-"Yijongkumkam(醫宗金鑑)","Chimkuhak 1st(鍼灸學-上)", Kyunghyulhakchongseo(經穴學叢書)"-We Compared the way of positioning of acupoints, also did on the location of acupoints, vein, vascular system, around the acupoints, based on the anatomical structures(esp. artery) Results : On the basis of old acu-books, the number of acupoints(only in the twelve meridian) on the pulse is 35, and the number of points not in the old books but on the pulse is 6, sum is 41 points. Comparion from Sambukuhu consultation method(三部九候診法) in "Somun(素問)", Some points, Taeyang(太陽, not in the twelve meridian), Yimun(耳門) and Koryo(Yimun and Koryo are in) are on pulse. Like Chonbu(天府) and Hyupbaek(俠白), We can feel the pulse on ulna side of biceps muscle, noton radial side. Shikdu(食竇) was described as on pulse in the "Chimkushimbopyokyul(鍼灸心法要訣)", but we could hardly feel it. Conclusions : It'll be right to add the Yimun(耳門) and Koryo to the points on pulse, of course two points are not in the twelve meridian. We must take the points Chonbu(天府) and Hyupbaek(俠白), on ulna side of biceps muscle. Shikdu(食竇) must be excepted, because we cannot feel the pulse in consultation.

  • PDF

Failure probability of tall buildings with TMD in the presence of structural, seismic, and soil uncertainties

  • Sadegh, Etedali;Mohammad, Seifi;Morteza, Akbari
    • Structural Engineering and Mechanics
    • /
    • v.85 no.3
    • /
    • pp.381-391
    • /
    • 2023
  • The seismic performance of the tall building equipped with a tuned mass damper (TMD) considering soil-structure interaction (SSI) effects is well studied in the literature. However, these studies are performed on the nominal model of the seismic-excited structural system with SSI. Hence, the outcomes of the studies may not valid for the actual structural system. To address the study gap, the reliability theory as a useful and powerful method is utilized in the paper. The present study aims to carry out reliability analyses on tall buildings equipped with TMD under near-field pulse-like (NFPL) ground motions considering SSI effects using a subset simulation (SS) method. In the presence of uncertainties of the structural model, TMD device, foundation, soil, and near-field pulse-like ground motions, the numerical studies are performed on a benchmark 40-story building and the failure probabilities of the structures with and without TMD are evaluated. Three types of soils (dense, medium, and soft soils), different earthquake magnitudes (Mw = 7,0. 7,25. 7,5 ), different nearest fault distances (r = 5. 10 and 15 km), and three seismic performance levels of immediate occupancy (IO), life safety (LS), and collapse prevention (CP) are considered in this study. The results show that tall buildings built near faults and on soft soils are more affected by uncertainties of the structural and ground motion models. Hence, ignoring these uncertainties may result in an inaccurate estimation of the maximum seismic responses. Also, it is found the TMD is not able to reduce the failure probabilities of the structure in the IO seismic performance level, especially for high earthquake magnitudes and structures built near the fault. However, TMD is significantly effective in the reduction of failure probability for the LS and CP performance levels. For weak earthquakes and long fault distances, the failure probabilities of both structures with and without TMD are near zero, and the efficiency of the TMD in the reduction of failure probabilities is reduced by increasing earthquake magnitudes and the reduction of fault distance. As soil softness increases, the failure probability of structures both with and without TMD often increases, especially for severe near-fault earthquake motion.