• Title/Summary/Keyword: pulse waveforms

Search Result 165, Processing Time 0.022 seconds

QRS Detection based on Maximum A-Posterior Estimation (MAP Estimation을 이용한 QRS Detection)

  • 정희교;신건수
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.205-214
    • /
    • 1987
  • In this paper, a mathmatical model for the purpose of QRS detection is considered in the case of the occurence of nonoverlappjng pulse-shaped waveforms corrupted with white noise. The number of waveform, the arrival times, amplitudes, and widths of QRS complexes are regarded as random variables. The joint MAP estimation of all the unknown Quantities consists of linear filtering followed by an optimization procedure. Because the optimization procedure is time-consuming, this procedure is modified so that a threshold test is obtained.

  • PDF

A White-LED Driver IC for Mobile Applications (모바일용 White-LED Driver IC)

  • Ko, Young-Seok;Park, Shi-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04b
    • /
    • pp.39-40
    • /
    • 2009
  • This paper presents a white-LED driver IC for a mobile application. It uses a high efficiency current mode boost converter method for a low voltage application. For a LED drive, it provides a PWM(Pulse Width Modulation) and analog dimming function. The device was designed and fabricated using 0.35um BCD process. The evaluated waveforms for an implemented IC show promising results.

  • PDF

Experiments and analysis of droplet formation influenced by driving waveform (구동파형에 따른 잉크액적 형성 실험 및 해석)

  • Shin, Dong-Youn
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.26-29
    • /
    • 2008
  • In the fields of electronics and displays where inkjet printing has demonstrated its capability to fabricate colorant subpixels of thin film transistor liquid crystal(TFT LCD) color filters and organic light emitting diode (OLED) displays, conducting tracks and TFTs, the production of satellite droplets is one of primary things to eliminate because they generally deteriorate the pattern quality. To understand the production mechanism of satellite droplets in this paper, driving waveforms such as monopolar and bipolar were employed and the influence of the pulse duration time were investigated in both experimental and numerical aspects.

  • PDF

Experimental Waveforms of Single-Pulse Soft-Switching PFC Converter

  • Katsunori Taniguchi;Koh, Kang-Hoon;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.56-63
    • /
    • 2004
  • A new driving circuit for the SPSS (Single-Pulse Soft-Switching) PFC converter is proposed. The switching device of a SPSS converter switches once in every half cycle of an AC commercial power source. Therefore, it can be solved many problems caused by the high frequency operation. The proposed SPSS converter achieves the soft-switching operation and the EMI noise can be reduced. The resonant capacitor voltage supplies to the resonant inductor even if the input AC voltage is the vicinity of zero cross voltage. Then, the power factor and input current waveform can be improved without delay time. A new driving circuit achieves the operation of SPSS converter by one switching drive circuit. The proposed converter can be satisfied the IEC standard sufficiently

Fuzzy Technique based Chopper Control for Slip Energy Recovery System with Twelve-Pulse Converter

  • Tunyasrirut, S.;Ngamwiwit, J.;Furuya, T.;Yamamoto, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.509-514
    • /
    • 2004
  • This paper introduces the modified slip energy recovery system in order to improve its power factor and to reduce harmonics of line current waveforms. Twelve pulse line commutated converter with the chopper type IGBT is applied where the chopper is applied across the DC terminal and the chopped DC is fed to the converter operating as an inverter and then passed through the wye-wye and delta-wye transformer circuit. This scheme leads to be able to adjust the speed of the motor by the duty cycle of the chopper operating in PWM mode. The fuzzy logic controller is also introduced to the modified slip energy recovery system for keeping the motor speed to be constant when the load varies. The experimental results in testing the 0.22 kW wound rotor induction motor from no-load condition to rated condition show the effectiveness of the proposed control scheme.

  • PDF

A Development of dynamic characteristics measuring system and linearization control method for Linear Pulse Motor (LPM의 동추력특성측정 및 선형화 제어기법 개발)

  • Kim, Moon-Hwan;Lee, Nam-Ki;Kim, Kook-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2146-2148
    • /
    • 1997
  • We had developed a prototype Linear Pulse Motor(LPM) for the linear motion actuator. In this paper, it is mentioned a new dynamic equations which is considered the nonlinearity of the thrust force of LPM. And a measuring method of ripples in the thrust forces is proposed and the ripples were measured in the laboratory. In the experimental results, it is shown the validity of the proposed measuring method for catching of the ripple values and waveforms in the thrust force.

  • PDF

Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

  • Kim, No-Hyu;Lee, Sang-Soon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.577-582
    • /
    • 2003
  • This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process.

A Study on Suppression of Ultrasonic Background Noise Signal using wavelet Transform (Wavelet변환을 이용한 초음파 잡음신호의 제거에 관한 연구)

  • 박익근
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.1
    • /
    • pp.135-141
    • /
    • 1999
  • Recently, advance signal analysis which is called "Time-Frequency Analysis" has been developed. Wavelet and Wigner Distribution are used to the method. Wavelet transform(WT) is applied to time-frequency analysis of waveforms obtained by an ultrasonic pulse-echo technique. The Gabor function is adopted as the analyzing wavelet. Wavelet analysis method is an attractive technique for evolution of material characterization evoluation. In this paper, the feasibility of suppression of ultrasonic background noise signal using WT has been presented. These results suggest that ultrasonic background noise ginal can be suppressed and enhanced even for SNR of 20.8 dB. This property of the WT is extremely useful for the detecting flaw echos embedded in background noise.und noise.

  • PDF

A Study on Waveform Parameter for the Electrotactile Stimulation (경피(經皮) 전기자극(電氣刺戟)을 파형(波形) 파라메터에 관한 연구(硏究))

  • Ham, K.K.;Min, H.K.;Lee, H.J.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.198-202
    • /
    • 1992
  • In this paper, we have performed an experiment to obtain an optimized electric stimulation condition on the tip or a ringer skin. The desired parameters for stimulation of the finger tip skin are waveforms, frequency, stimulation intensity, duty cycle. As a result, when the finger skin was stimulated with monophasic, biphasic, and differntial phasic, the most appropriate condition was 200 to 250[Hz] in frequency, 10 to 25[%] in duty cycle. Burst type pulse was more sensitive effect than that of continuous pulse methode.

  • PDF

Zero Voltage and Zero Current Switching Full Bridge DC-DC Converter Using Novel Secondary Active Clamp (새로운 2차측 능동 클램프회로의 영전압 영전류 스위칭 Full Bridge DC-DC 컨버터)

  • Kim, Byung-Chul;Kim, Hyung-Gon;Kim, Kwang-Heon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.13-15
    • /
    • 1999
  • The zero voltage and zero current switching(ZVZCS) full bridge (FB) PWM converter using secondary active clamp is characterized by high efficiency, good ZVZCS characteristic, simple topology and low cost. But at the period for discharge of the secondary clamp capacitor, peak pulses and ringing pulse occur in rectified secondary side of the converter. In this paper, a novel secondary active clamp circuit for the ZVZCS FB PWM converter is proposed and a 50 kHz, 500 W prototype converter was experimented for verification of the converter characteristics. It was verified that high voltage peak pulses and ringing pulse on secondary rectified waveforms of the converter are decreased effectively.

  • PDF