• Title/Summary/Keyword: pulse test

Search Result 1,177, Processing Time 0.032 seconds

A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection (조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

Ultrasonic Sensor Controlled Sprayer for Variable Rate Liner Applications (초음파센서를 이용한 변량제어 스프레이어)

  • Jeon, Hong-Young;Zhu, Heping
    • Journal of Biosystems Engineering
    • /
    • v.36 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • An experimental variable rate nursery sprayer was developed to adjust application rates for canopy volume in real time. The sprayer consisted of two vertical booms integrated with ultrasonic sensors, and variable rate nozzles coupled with pulse width modulation (PMW) based solenoid valves. A custom-designed microcontroller instructed the sensors to detect canopy size and occurrence and then controlled nozzles to achieve variable application rates. A spray delivery system, which consisted of diaphragm pump, pressure regulator and 4-cycle gasoline engine, offered the spray discharge function. Spray delay time, time adjustment in spray trigger for the leading distance of the sensor, was measured with a high-speed camera, and it was from 50 to 140 ms earlier than the desired time (398 ms) at 3.2 km/h under indoor conditions. Consequently, the sprayer triggered 4.5 to 12.5 cm prior to detected targets. Duty cycles of the sprayer were from 20 to 34 ms for senor-to-canopy (STC) distance from 0.30 to 0.76 m. Outdoor test confirmed that the nozzles were triggered from 290 to 380 ms after detecting tree canopy at 3.2 km/h. The spray rate of the new sprayer was 58.4 to 85.2% of the constant application rate (935 L/ha). Spray coverage was collected at four areas of evergreen canopy by water sensitive papers (WSP), and ranged from 1.9 to 41.1% and 1.8 to 34.7% for variable and constant rate applications, respectively. One WSP area had significant (P < 0.05) difference in mean spray coverage between two application conditions.

Research of the Signal Processing techniques applied to the Command Link Receiver of High Speed Aircrafts (고속 비행체 명령수신기 신호처리 기법 연구)

  • Yun, Jung-Kug;Jung, Won-Hee;Kim, Kyun-Hoe;Yun, Myung-Han
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.3
    • /
    • pp.266-273
    • /
    • 2016
  • In this paper, we propose the signal processing techniques for the command link receiver mounted to aircrafts flying at a high speed. In order to acquire the various information transmitted from ground through radio frequency links, the wide received signal range must be guaranteed as well as the carrier synchronization and symbol synchronization be performed correctly within short pulse sections. After the synchronization step, we should be able to achieve theoretical performance of the modulation and demodulation scheme applied as deciding bit and symbol at the time appointed. By test results, we make sure that the proposed signal processing techniques can be effectively applied command link receiver mounted to aircrafts.

Validity of Transfusing Group O+ Unmatched Packed Red Blood Cells in Hemorrhagic Shock Patients (출혈성 쇼크 환자에서 비교차시험 O+형 혈액 수혈의 유용성)

  • Lee, Ji-hwan;Choa, Minhong;Cho, Junho;Chung, Sung Pil
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.167-171
    • /
    • 2009
  • Purpose: It is important to begin a transfusion safely and appropriately as soon as possible in a hemorrhagic shock patient. A group $O^+$ unmatched pack red blood cell (universal $O^+$) transfusion may satisfy that requirement. We report our experiences with universal $O^+$ to compare its usefulness for hemorrhagic shock patients with that of a matched pack red blood cell transfusion in the emergency department (ED). Methods: This is a retrospective study. Patients who had systolic blood pressure of less than 90 mmHg or a pulse rate of more than 120 beats per minute in the ED were included, and their medical records were reviewed. The collected data were demographic data, vital signs, blood test results, time to transfusion, the amount of transfusion, complications, and diagnoses. We calculated the emergency transfusion score (ETS) based on the patients' medical records. Results: Two hundred thirty-five patients were included. Forty-eight patients (36 trauma and 12 non-trauma patients) were transfused with a universal $O^+$. These patients had less time to transfusion compared with the cross-matched transfusion groups (35${\pm}$42 versus $170{\pm}187$ minutes, p<0.001). There were no differences in complications between groups (p=0.076). Of the patients who were transfused with universal $O^+$, 94.4% got more than 3 ETS. Conclusion: The universal $O^+$ transfusion, compared with matched pack red blood cell transfusion, should be a useful treatment for ED hemorrhagic shock patient due to its having a shorter time to transfusion without an increase in complications.

The Development of Automatic Grease Lubricator Driven by Gear Mechanism with Controlled Operating Time (주유시간 조절이 가능한 기어 메커니즘 구동방식의 자동그리스주유기 개발)

  • Wang, Duck-Hyun;Lee, Kyu-Young;Lee, Sang-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.2 s.179
    • /
    • pp.199-206
    • /
    • 2006
  • Automatic grease lubricator is equipment that provides adequate amount of fresh grease constantly to the shaft and the bearings of machines. It minimizes the friction heat and reduces the friction loss of machines to the least. This research is to develop automatic grease lubricator by gear driven mechanism with controlled operation time. The ultimate design of this equipment is to lubricate an adequate amount of grease by a simple switch clicking according to the advanced set cycle. The backlash of the gear was minimized to increase the output power. To increase the power of gear mechanism, the binding frequency and the thickness of the coil were changed. To control the rotating cycles of the main shaft according to its set numbers, different resistance and chips were used to design the circuit to controls electrical signals with pulse. The body of the lubricator was analyzed by stress analysis with different constructed angle. The stress analysis for differing loading pressures applied to the exterior body of grease lubricator due to the setup angle, was found that the maximum stress was distributed over the outlet part where the grease lubricator suddenly narrowed contracts. Digital mock-up was analyzed and the rapid prototyping(RP) trial products were tested with PCB circuit and grease. The evaluation of the outlet capacity for RP trial products was conducted, because the friction caused by the outlet on the wall surface was an important factor in the operation of the equipment. Finally, the finishing process was applied to decrease the roughness of the surface to a comparable level and was able to test the performance examination for the product.

A Study on the Clinical Diagnosis of Hyperthyroidism (갑상선기능항진증(甲狀腺機能亢進症)의 임상적(臨床的) 진단(診斷)에 관(關)한 연구(硏究))

  • Ku, In-Seo;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.7 no.1
    • /
    • pp.15-29
    • /
    • 1973
  • To attain a simple and reliable method of evaluating the thyroid function the reliability of the clinical manifestation and the conventional thyroid function tests in diagnosing the hyperthyroidism was studied. The subjects included 184 patients with hyperthyroidism and 66 cases with euthyroidism, who were treated at the Thyroid Clinic, Seoul National University Hospital, from July 1971 through August 1972. The observed results were as follows: 1. In the cases of hyperthyroidism, 19% of the patients were male and 81% female; in the cases of euthyroidism, 7.6% of the patients were male and 92.4% female. The majority of the patients were in 2nd to 4th decades of their lives. 2. There were objective signs clearly manifested in hyperthyroidism which were rare or absent in the euthyroid state. These clinical signs included wide pulse pressure, tachycardia, systolic murmur, exophthalmos, tremor, and warm skin. In the hyperthyroid state 91.3% of the cases manifested two or more of the above signs, whereas in the euthyroid state no patients manifested any two of the above signs. 3. The most frequent complaints of the patients with thyroid disease were palpitation, weight loss, increased appetite, heat intolerance, perspiration, hunger feeling; nervousness, exertional dyspnea, etc. There was no clear difference in the incidence of the symptoms between hyperthyroidism and euthyroidism. 4. In the diagnosis of hyperthyroidism, the reliability of thyroid ?unction tests was as follows; $T_7$ was 92.4% reliable, $^{125}IT_3$ resin uptake rate 91.6% reliable, $^{131}I$ thyroid uptake rate in 24 hrs. 89.4% reliable, serum $T_4$ level 85.9% reliable and BMR 75.5% reliable. Therefore the careful observation of the clinical manifestation of the disease is a simple and reliable way of making a correct diagnosis of either hyperthyroidism or euthyroidism. 5. In hyperthyroidism there shows no correlationship between the results of the thyroid function test and clinical signs but a high BMR was associated with both tachycardia and systolic murmur.

  • PDF

A Research of Prehospital 119 Emergency Medical Service for Stroke Patients (병원 전 뇌졸중 환자의 구급의료 실태 분석)

  • Song, Hyun-Mok;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.14-20
    • /
    • 2012
  • This study analyzes the influencing factors of prehospital 119 Emergency Medical Service for Stroke Patients in prehospital. From July, 2010 to June, 2011, 123 patients were diagnosed with Stroke in Emergency Medical Center. Among 123 patients, the prehospital assessment rates were as follows : blood pressure checked 73.2 %, pulse checked 73.2 %, respiratory checked 64.2 %, $SpO_2$ checked 79.7 %, pupil reflex test 88.6 %, Electrocardiogram checked 14.6 %, blood sugar checked 19.5 %. Prehospital emergency medical care, Oropharyngeal airway insertion 2.4 %, Manual airway maneuvers 17.1 %, endotracheal intubation 2.7 %, oxygen supply 35.4 %, and suction and intravenous fluid therapy 0 %. The property of mental status evaluation by 119 Emergency Medical Service was nearly perfect, but the patients assessment and emergency medical care were not.

A Study of X-ray Output for Diagnostic X-ray Equipment (진단용 X선 발생 장치의 X선 출력에 관한 연구)

  • Ko, Shin-Gwan;Ahn, Bong-Seon;Jang, Sang-Sup;Choi, Jong-Woon;Shin, Young-Soon
    • Journal of radiological science and technology
    • /
    • v.18 no.2
    • /
    • pp.61-73
    • /
    • 1995
  • For the managements of the diagnostic X-ray equipments, the authors examined the output of single phase rectification assembly, Three phase rectification assembly and serial radiographic appartus, and got the following conclusions. 1. When the tube voltages in X-ray control panels ware compared to the measured values on the kVp pulse meter, only little differences were detected in all the X-ray equipments. And most of the equipments were all well managed within the internationally permitted limits, excepting the 12.02 % error at 120 kVp in three phase rectifying assembly. 2. As for the X-ray qualities affecting the X-ray images, the serial radiographic apparatus showed excellence, while the single phase rectification assembly were somewhat inferior to the others only maining the internationally recommended limits. 3. The tube voltage ranges where the X-ray output showed excellence were $100{\sim}200\;mA$ in serial radiographic apparatus, $200{\sim}350\;mA$ in three phase rectification assembly and $350{\sim}400\;mA$ in single phase rectification assembly respectively. 4. In the repeatability test of the X-ray equipments, CVs were in the range of $0.0029{\sim}0.049$, which is within the HEW or KS standards. Consequently all the equipments are thought to be well-manage. 5. This study on characteristics and output of the X-ray equipments was accomplished within a limited short time. Long-time researches on the function managements for the X-ray equipments should be followed along with the periodical checking the output for reduction of X-ray exposures to the patients or radio-technologists, and for maintanance and prediction of trouble of the equipments.

  • PDF

Fracture Behavior of Pre-cracked AISI 4130 Specimens by Means of Acoustic Emission and Ultrasonic C-scan Measurements (음향방출과 초음파 C-scan을 이용한 AISI 4130 균열재의 파괴거동 연구)

  • Ong, J.W.;Moon, S.I.;Jeong, H.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.3
    • /
    • pp.7-13
    • /
    • 1993
  • Fracture behavior of pre-cracked compact tension specimens made of AISI 4130 steel was investigated using acoustic emission (AE) and ultrasonic C-scan measurements. While each specimen was loaded up to a certain level, various acoustic emission parameters were recorded together with the crack opening displacement (COD). An elastic-plastic finite element analysis was performed to calculate COD and the damage (plastic) zone size ahead of crack tip. Ultrasonic C-scans, in a pulse-echo, immersion mode, were done for mapping the damage zone size. The agreement between the finite element results and the measured COD was satisfactory. Based on AE results, the test specimens were found to show ductile behavior. The slope of the total ringdown counts vs. COD curve was useful to determine the crack initiation. The preliminary C-scan images showed evidence of changes in the amplitude of ultrasonic signal in the damaged region, and the shape and size of the damage zone matched qualitatively with the finite element results. A further work on the damage zone sizing was also pointed out.

  • PDF

Nuclear Remodeling and In Vitro Development Following Somatic Cell Nuclear Transfer in Swine

  • Yoon Jong-Taek;Kim Yong-Yeup;Lee Jong-Wan;Min Kwan-Sil;Hwang Seongsoo
    • Reproductive and Developmental Biology
    • /
    • v.28 no.4
    • /
    • pp.241-245
    • /
    • 2004
  • This study was conducted to investigate nuclear remodeling and developmental rate following nuclear transfer of fetal fibroblast cells, ear skin cells and oviduct epithelial cells into porcine recipient oocytes. To test par-thenogenetic activation, oocytes were treated with a 6-dimethylaminopurine (6-DMAP), a single DC-pulse (DC), calcium ionomycin (ionomycin), DC+6-DMAP and ionomycin + 6-DMAP after in vitro maturation. For nuclear transfer, in vitro matured oocytes were enucleated, and donor cells were transferred into oocytes. Cloned embryos were fused and stimulated with 6-DMAP for 4 h and cultured in vitro for 6 days. Among treatments for parthenogenesis, the activation rate of DC +6-DMAP treatment was significantly higher than that of single treatment roups (p<0.01), except for DC treatment group. However, the difference was not significant in activation rate compared to other complex treatment groups. Nuclear swelling of the cloned embryos was initiated at 60 min after stimulation and increased afterwards. Fusion rates were not different among different donor cells. Cleavage rates of DC treatment groups were significantly higher than those of DC+6-DMAP treatment groups (p<0.05) in case that fetal fibroblast and ear cells were used for nuclear donor. The cloned embryos from developed to blastocysts in oviduct epithelial cell nuclear transfer with DC+6-DMAP treatment was significantly higher compared to those with DC only treatment (p<0.05). However, no blastocyst was developed from nuclear transfer of fetal fibroblast and ear cells regardless of activation treatments. Based on these results, a proper activation stimulation may be necessary to increase the activation rate and the development to blastocyst in cloned porcine embryos.