• Title/Summary/Keyword: pulse sensor

Search Result 541, Processing Time 0.024 seconds

A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices

  • Lee, Sang-Suk;An, Myoung-Chone;Ahn, Sung-Hoon
    • Journal of Magnetics
    • /
    • v.14 no.3
    • /
    • pp.132-136
    • /
    • 2009
  • This study investigated the radial pulse waveform obtained by a medical pulsimeter sensor. A pulse-sensing part array consisting of multiple Hall devices was located over a skin-contacting part with a hard magnetic material. The periodic movement of the magnetic material of the skin-contacting part affected the magnetic field in the pulse-sensing part array and was detected by multiple Hall devices. The analysis of a radial pulse waveform that is measured noninvasively by detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of oriental medical apparatus.

Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndrome Using Pen-type Piezoresistive Sensor (펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가)

  • Ha, Ye-Jin;Cho, Mun-Young;Yun, Jong-Min;Jun, Kyu-Sang;Park, Soo-Jung;Shin, Sun-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.257-271
    • /
    • 2012
  • Objectives : The purpose of this study was to confirm that the pulse analyzer is useful for analyzing characteristics of variables of pulse waves in age categories, evaluating pulse waves of the metabolic syndrome group, compared with those of the non-metabolic syndrome group in Korean adults. Methods : The pulse wave variables were measured in Guan of all 1,056 subjects by the pulse analyzer, using a pen-type piezoresistive sensor. The physical measurement, blood test and survey were also performed by each subject. Results : In the age categories, height of pre-incisura (h2), height of tidal wave (h3), area of percussion wave (Aw), and width of percussion wave (w) increased in accordance with increase in age. While ratio of systolic period area (As) went up according to the increase of age, ratio of diastolic period area (Ad) went down. Radial augmentation index (R-AI), h2/h1, h3/h1, w/t and angle of percussion wave went up by aging, generally. Aw rate (Aw/At) also increased. Among the metabolic syndrome group, in the ages of 19 and 44, ratio of systolic period area (As) was higher and ratio of diastolic period area (Ad) was lower than in the non-metabolic group. w/t, Aw/At, and angle of percussion wave were higher than in the non-metabolic syndrome group. Among the metabolic syndrome group over the age of 60, height of pre-incisura (h2), height of tidal wave (h3), total area (At), area of percussion wave (Aw), radial augmentation index (R-AI), h2/h1 and h3/h1 were higher than in the non-metabolic syndrome group. Conclusions : The pulse analyzer is useful to analyze arterial stiffness in the age categories and in the metabolic syndrome group by some measures.

An adaptive pulse measurement mechanism using ECG sensor node based on Zigbee (지그비 기반의 심전도 센서노드를 사용한 적응형 심박탐지 모델)

  • Lee, Byung-Mun;Park, Yeon-Hee;Lee, Young-Ho
    • Journal of Internet Computing and Services
    • /
    • v.10 no.3
    • /
    • pp.27-33
    • /
    • 2009
  • With the upcoming u-healthcare era, a way of measurement for vital sign monitoring of cardiac patients is changing as well. In existing measurement of cardiac patients, various wire in ECG measuring equipment has caused much discomfort and inconvenience. In order to decrease the problem, we are developing an efficient measurement of ECG signal using Wireless sensor network. In this paper, we present a way to reduce amount of data by transmitting ECG data collected from radio electrocardiogram sensor based on Zigbee after calculating cardiac rate. And in order to control the error which can be caused by the different ECG signal intensity each individual can has, we also suggest an adaptive pulse measurement model which can measure heart rate with correcting according to different ECG intensity. To verify the suggested model, sensor application was developed and the data was acquired in TinyOS 2.0 environment and the adaptive pulse measurement model was evaluated through the data from the experiments.

  • PDF

Visible Light Communication Systems for Sensor Networks Using Synchronizing Pulse Transmission Through the Power Lines (전력선 전송 동기신호를 이용한 센서 네트워크용 가시광통신시스템)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.212-218
    • /
    • 2013
  • In this paper, we introduce a new method to reduce the inter-channel crosstalk in visible light communication (VLC) systems using the synchronizing pulses transmitted through the power lines. Synchronizing pulses are simultaneously transmitted to multiple VLC transmitters and receivers through the 220V power line. Each VLC transmitter modulates an LED and each VLC receiver demodulates the signal light in the time slot that is allocated with reference to the synchronizing pulses. This method is very simple and effective to prevent the inter-channel crosstalk in VLC systems for sensor networks because every VLC system can easily get the synchronizing pulses from the nearby power line.

CCD Image Sensor with Variable Reset Operation

  • Park, Sang-Sik;Uh, Hyung-Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 2003
  • The reset operation of a CCD image sensor was improved using charge trapping of a MOS structure to realize a loe voltage driving. A DC bias generating circuit was added to the reset structure which sets reference voltage and holds the signal charge to be detected. The generated DC bias is added to the reset pulse to give an optimized voltage margin to the reset operation, and is controlled by adjustment of the threshold voltage of a MOS transistor in the circuit. By the pulse-type stress voltage applied to the gate, the electrons and holes were injected to the gate dielectrics, and the threshold voltage could be adjusted ranging from 0.2V to 5.5V, which is suitable for controlling the incomplete reset operation due to the process variation. The charges trapped in the silicon nitride lead to the positive and negative shift of the threshold voltage, and this phenomenon is explained by Poole-Frenkel conduction and Fowler-Nordheim conduction. A CCD image sensor with $492(H){\;}{\times}{\;}510(V)$ pixels adopting this structure showed complete reset operation with the driving voltage of 3.0V. The resolution chart taken with the image sensor shows no image flow to the illumination of 30 lux, even in the driving voltage of 3.0V.

Linking Clinical Events in Elderly to In-home Monitoring Sensor Data: A Brief Review and a Pilot Study on Predicting Pulse Pressure

  • Popescu, Mihail;Florea, Elena
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.180-199
    • /
    • 2008
  • Technology has had a tremendous impact on our daily lives. Recently, technology and its impact on aging has become an expanding field of inquiry. A major reason for this interest is that the use of technology can help older people who experience deteriorating health to live independently. In this paper we give a brief review of the in-home monitoring technologies for the elderly. In the pilot study, we analyze the possibility of employing the data generated by a continuous, unobtrusive nursing home monitoring system for predicting elevated(abnormal)pulse pressure(PP) in elderly(PP=systolic blood pressure-diastolic blood pressure). Our sensor data capture external information(behavioral) about the resident that is subsequently reflected in the predicted PP. By continuously predicting the possibility of elevated pulse pressure we may alert the nursing staff when some predefined threshold is exceeded. This approach may provide additional blood pressure monitoring for the elderly persons susceptible to blood pressure variations during the time between two nursing visits. We conducted a retrospective pilot study on two residents of the TigerPlace aging in place facility with age over 70, that had blood pressure measured between 100 and 300 times during a period of two years. The pilot study suggested that abnormal pulse pressure can be reasonably well estimated (an area under ROC curve of about 0.75) using apartment bed and motion sensors.

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.4
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.

Analysing of pulse wave parameter and typical pulse pattern for diagnosis in floating and sinking pulses (${\cdot}$ 침맥 진단에 유용한 맥상 파라메터 및 대표맥상 분석)

  • Lee, Yu-Jung;Lee, Jeon;Choi, Eun-Ji;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.93-101
    • /
    • 2006
  • Pulse feeling is one of the most important diagnosis method in Oriental medicine. But it is not easy to make an objective and standardized diagnosis. In this study, we found how to quantify diagnosis. Specially dally the high practicality in clinic, we search some parameters especially well-related to floating and sinking pulse by statistic analysis. By extension, we find the pulse patterns of the floating and sinking pulse. We choose 15 subjects diagnosed as floating pulse and 15 subjects diagnosed as sinking pulse by oriental doctors. And their pulse signals were acquired by Pulse analyzer which has piezoresistive pressure sensor. For the quantification of the floating and sinking pulse, at first, we examined the parameters which were highly correlated with oriental doctor's diagnosis. And then we derived pulse patterns of the floating-sinking pulse from preprocessed signal and its ensemble average. We also looked trend variation (PH-Curve) between contact and pulse pressure. As a result, statistically there is the biggest difference between contact pressure, the maximum pulse pressure, diastolic area (Ad) and floating and sinking data. Through the PH-Curve, which represented the relationship between contact and pulse pressure, we could divide the floating and sinking pulse clearly. As a basic research of pulse diagnosis algorithm, we can contribute to select essential parameters in diagnosis algorithm And using these diagnosis method, we expect to find typical pulse patterns and some useful parameters about other pulses like slow/rapid, large/fine pulse and so on. We hope that this study will contribute pulse objectification.

  • PDF

Volume Pulse Wave Detection System for Oriental Medicine (한방용 용적맥파 시스템)

  • Kim, H.T.;Han, S.C.;Choi, T.J.;Kim, J.K.;Huh, W.;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.77-80
    • /
    • 2001
  • In this paper, we devised volume pulse detection system which can quantitatively represent a artery elasticity for oriental clinic. Volume pulse wave detecter system consist of transducer which has IRLED-photodiode detecter, temperature sensor and filter and preprocessing circuits, data conversion and serial communication parts, and computer system. The high-pass filter are detect volume pulse wave and lowpass filter detect tissue thickness. The detected volume pulse wave are normalized by tissue thickness value with a division process. As the result of experiment, we can detect normalized volume pulse wave with effectively.

  • PDF

Failure Case Studies of Sensors for Electronic Controlled Engine in LPG Vehicle (LPG 자동차에서 전자제어엔진용 센서의 고장사례에 관한 연구)

  • Kim, Chung-Kyun;Lee, Il-Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.56-62
    • /
    • 2010
  • The purpose of this paper analyzes and investigates the failure case studies of electronic control sensors for a LP gas engine. The malfunction of crank angle sensor, which controls a fuel injection volume of LP gas, displays an irregular and non-uniform pulse wave form. The pulse form, which is related to the noise of the crank angle sensor, displays at the rectangular peak with a saw-toothed shape and is intermittently generated with a level of 2.46V noise signal. The malfunction of No. 1 TDC sensor in which is caused from the internal disorder affects to the reduction of engine power and engine stop suddenly. If the malfunction of oxygen sensor is occurred due to a wiring problem of a sensor connector, the LP gas vehicle may produce a shaking and disharmony of an engine because of no signal supply from the oxygen sensor. The air cleaner replica produces the clogging of continuous supply of fresh air. This may cause the retardation of vehicle acceleration and engine disharmony intermittently.