• Title/Summary/Keyword: pulse protocol

Search Result 82, Processing Time 0.021 seconds

A Design and Implementation of Information System Using Zigbee Technology (Zigbee 모바일단말 하드웨어 설계와 정보시스템 구축)

  • Ha, Kyeoung-Ju
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.3
    • /
    • pp.44-49
    • /
    • 2009
  • We show the way how to design and develop the information system using Zigbee technology. First we set the protocol for zigbee tag and reader. And then we give the information system using designed system based on zigbee technology. In this paper, we use MG2455-F48 module as zigbee module.

The Propose of Optimal Flow Data Acquisition by Error Rate Analysis of Flow Data (유량 데이터 오차율 분석을 통한 최적의 유량데이터 취득방안 제안)

  • Kim, Yunha;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.249-256
    • /
    • 2017
  • Recently, application areas based on M2M (Machine-to-Machine communications) and IoT (Internet of Things) technologies are expanding rapidly. Accordingly, water flow and water quality management improvements are being pursued by applying this technology to water and sewage facilities. Especially, water management will collect and store accurate data based on various ICT technologies, and then will expand its service range to remote meter-reading service using smart metering system. For this, the error in flow rate data transmitting should be minimized to obtain credibility on related additional service system such as real time water flow rate analysis and billing. In this study, we have identified the structural problems in transmitting process and protocol to minimize errors in flow rate data transmission and its handling process which is essential to water supply pipeline management. The result confirmed that data acquisition via communication system is better than via analogue current values and pulse, and for communication method case, applying the industrial standard protocol is better for minimizing errors during data acquisition versus applying user assigned method.

The Comparison of Effectiveness in Prehospital Protocol Education on CardioPulmonary Resuscitation (심폐소생술에 대한 현장업무 프로토콜 교육 효과 비교)

  • Shin, Sang-Yol;Jung, Ji-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3418-3426
    • /
    • 2009
  • The purpose of this study was to investigate the feasibility of field operation protocol for cardiopulmonary resuscitation(CPR) in person with non-traumatic arrest. This study was performed from May 1 through June 27, 2008, and subjects were 150 students who are attending the department of Emergency Medical Service in J and K universities which located in Jeollabuk-do and Jeollanam-do areas. Practical conformance was verified using by nonequivalent control group pretest-posttest design. This study divided into two groups; experimental group that employed field operation protocol and control group that applied conventional CPR protocol, and comparative analyzed statistically the necessary time of the items of each protocol. The results indicated that each performance time of 18 items was reduced over 3 seconds except 5 items(assessment of consciousness, airway control, two times of artificial respiration, check of circulation, and five cycles of CPR). And time of 6 items(intubation, peripheral intravenous line, reassessment of consciousness, pupil reaction, carotid artery pulse, and vital sign) was minimized more than 60 seconds, and total performing time was shortened 110.85 seconds. The results suggested that total performing time in pre and post test where the protocol was applied for two groups showed a statistically significant decrease(t=-6.580, p=.000). Consequently, field operation protocol for cardiopulmonary resuscitation(CPR) in person with non-traumatic arrest will be a available manual which support prompt and accurate decision making, and improve emergency medical service.

Development and Analysis of Low Cost Telecommand Processing System for Domestic Development Satellites (국내 개발 인공위성을 위한 저비용 원격명령 처리 시스템 구현 및 분석)

  • Park, Sang-Seob;Lee, Seongjin;Jun, Yong-Kee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.6
    • /
    • pp.481-488
    • /
    • 2021
  • The satellite telecommand processing system is the only way to provide telecommands for status monitoring, control, and mission execution. Domestic satellites can be divided into science, technology, and multi-purpose satellites, and geostationary satellites. These Satellites uses CCSDS standard protocol to communicate with ground stations. However, existing domestic satellites use only software to decode telecommands which increases cost of software development and verification of the developed software. Performance of software only approach is relatively low compared to hardware. In this paper, we present ASIC processing system specifically designed to decode telecommands. The system consists of a telecommand RAM, a protocol RAM/ROM, an ASIC, an interface unit of FPGA, and a relay block. The system handles general commands and pulse commands that are used in satellites. We established a ground station equipment and test environment to verify the system functionality, The result shows that our system reduces the development cost by 1/5 and improves the performance by 105 times compared to the previous systems that decode telecommands only by software.

Effect of Aroma Hand Massage on Anxiety and Immune Function in Patients with Gynecology Surgery under Local Anesthesia (향 요법 손 마사지가 국소마취 부인과 수술 환자의 불안과 면역기능에 미치는 효과)

  • Kim, Yun Ah;Sung, Mi Hae
    • Women's Health Nursing
    • /
    • v.20 no.2
    • /
    • pp.126-136
    • /
    • 2014
  • Purpose: The purpose of this study was to examine the effects of aroma hand massage on anxiety and immune function in patients who had gynecology surgery under local anesthesia. Methods: The research design was a nonequivalent control group with pre-and posttest design. Data were collected from June 5 to October 6, 2010. Participants included 20 patients in the aroma hand massage group, 20 patients in a hand massage group, and 20 in a control group. As an experimental treatment, hand massage was carried out following the hand massage protocol. Measures consisted of the State Trait Anxiety, Numeric Rating Scale (NRS) for anxiety, vital signs (systolic and diastolic blood pressure, pulse rate), and salivary cortisol for anxiety, and immunoglobulin A for immune function. Results: Aroma hand massage and hand massage group showed lower levels in NRS for anxiety, systolic and diastolic blood pressure, and pulse rate (p<.001) compared to controls. No group differences were found for state anxiety, salivary cortisol and immunoglobulin A. Conclusion: The results indicate that aroma hand massage and hand massage are effective in reducing anxiety and can be complementary alternative interventions for women having gynecology surgery under local anesthesia.

PD-DESYNC: Practical and Deterministic Desynchronization in Wireless Sensor Networks

  • Hyun, Sang-Hyun;Kim, Geon;Yang, Dongmin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.3880-3899
    • /
    • 2019
  • Distributive desynchronization algorithms based on pulse-coupled oscillator (PCO) models have been proposed for achieving collision-free wireless transmissions. These algorithms do not depend on a global clock or infrastructure overheads. Moreover, they gradually converge to fair time-division multiple access (TDMA) scheduling by broadcasting a periodic pulse signal (called a 'firing') and adjusting the next firing time based on firings from other nodes. The time required to achieve constant spacing between phase neighbors is estimated in a closed form or via stochastic modeling. However, because these algorithms cannot guarantee the completion of desynchronization in a short and bounded timeframe, they are not practical. Motivated by the limitations of these methods, we propose a practical solution called PD-DESYNC that provides a short and deterministic convergence time using a flag firing to indicate the beginning of a cycle. We demonstrate that the proposed method guarantees the completion of desynchronization within three cycles, regardless of the number of nodes. Through extensive simulations and experiments, we confirm that PD-DESYNC not only outperforms other algorithms in terms of convergence time but also is a practical solution.

Wire Optimization and Delay Reduction for High-Performance on-Chip Interconnection in GALS Systems

  • Oh, Myeong-Hoon;Kim, Young Woo;Kim, Hag Young;Kim, Young-Kyun;Kim, Jin-Sung
    • ETRI Journal
    • /
    • v.39 no.4
    • /
    • pp.582-591
    • /
    • 2017
  • To address the wire complexity problem in large-scale globally asynchronous, locally synchronous systems, a current-mode ternary encoding scheme was devised for a two-phase asynchronous protocol. However, for data transmission through a very long wire, few studies have been conducted on reducing the long propagation delay in current-mode circuits. Hence, this paper proposes a current steering logic (CSL) that is able to minimize the long delay for the devised current-mode ternary encoding scheme. The CSL creates pulse signals that charge or discharge the output signal in advance for a short period of time, and as a result, helps prevent a slack in the current signals. The encoder and decoder circuits employing the CSL are implemented using $0.25-{\mu}m$ CMOS technology. The results of an HSPICE simulation show that the normal and optimal mode operations of the CSL achieve a delay reduction of 11.8% and 28.1%, respectively, when compared to the original scheme for a 10-mm wire. They also reduce the power-delay product by 9.6% and 22.5%, respectively, at a data rate of 100 Mb/s for the same wire length.

Research on Anti-Reader Collision Protocols for Integrated RFID-WSNs

  • Ko, Doo-Hyun;Kim, Bum-Jin;An, Sun-Shin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.5
    • /
    • pp.776-796
    • /
    • 2010
  • Integrated RFID-WSNs (wireless sensor networks) have recently been researched to provide object identities, sensing information, mobile service, and network functionalities. In integrated RFID-WSNs, the reader collision is one of the critical problems. Above all, due to the absence of universally applicable anti-collision protocols and the channel capture phenomenon, the medium access control protocols in integrated RFID-WSNs suffer from reader collision and starvation problems. In this paper, we propose an efficient MAC protocol, called EMP, to avoid the above problems in integrated RFID-WSNs. EMP is a CSMA-based MAC protocol which is compatible with sensor networks operating on integrated nodes which consist of an RFID reader and a senor node. EMP resolves not only the reader collision problem, but also the starvation problem using a power control mechanism. To verify the performance of EMP, we compared it with other anti-reader collision MAC protocols using simulations. As a result, the performance of EMP showed improvements in throughput, system efficiency, and energy consumption compared to the single data channel protocols (CSMA/CA, Pulse, and DiCa) in dense deployment environments.

Development of a Patient Monitoring System Overall Architecture and Specifications (환자모니터링시스템의 개발 : 전체구조 및 기본사양)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • We have developed a patient monitoring system including module-based bedside monitors, interbed network, central stations, clinical workstations, and DB servers. A bedside monitor with a color LCD can accommodate up to 3 module cases and 21 different modules. Six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmoyaph are provided as parameter modules. In a single bedside monitor, modules and a module controller communicate with IMbps data rate through an intrabed network based on RS-485 and HDU protocol. At the same time, it communicates with other bedside monitors and central stations through interbed network based on 1 OMbps Ethernet and TCP/IP protocol. Central stations using 20" color CRT monitors can be connected with many bedside monitors and they display 18 channels of waveforms simultaneously. Clinical workstations are used mainly for the review of patient datE In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we have developed a relational database server dedicated to the patient monitoring system. Software for bedside monitor, central station, and clinical workstation fully utilizes graphical user interface techniques and all functions are controlled by a rotate/push button on the bedside monitor arid a mouse on the central station and clinical workstation. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances.nces.

  • PDF