• Title/Summary/Keyword: pulse pressure variation

Search Result 61, Processing Time 0.028 seconds

A comparision study on the variation of skin temperature on the adult male. female at environmental temperature (각 환경기온하에서의 성인 남녀의 피부온 비교)

  • 심부자
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.39-59
    • /
    • 1997
  • With a view to providing basic data for designing male's and female's clothes, healthy males and females(five each) were exposed to three different environmental temperature($20{\pm}1.0^{\circ}C$, $28{\pm}1.0^{\circ}C$, $32{\pm}1.0^{\circ}C$) in the nude. Their adaptation of skin temperature, physiological responses( rectal temperature, blood pressure, pulse rates) and psychological reactions(thermal, comfort and perceptive sweaty sensations) were analyzed as follows; The subjects's skin temperature had a similar look of adaptation, but the stability of skin temperature differed at tha $20{\pm}1.0^{\circ}C$ and at the $28{\pm}1.0^{\circ}C$ Males had higher skin temperature at three environmental temperatures, but females showed a higher temperature change at the $20{\pm}1.0^{\circ}C$ and $28{\pm}1.0^{\circ}C$ and males at the$32{\pm}1.0^{\circ}C$ Thus females were more resistant to the cold, while males were more resistant to the heat. As environmental temperature increased, rectal temperature and pulse rates also grew up. Females turned higher in rectal temperature and lower in blood pressure, but both sexes had a normal range of physiological reactions. Even though three environmental temperatures were same changes in thermal sensation at $28{\pm}1.0^{\circ}C$and in perceptive sweat sensation at $32{\pm}1.0^{\circ}C$, two sexes had the same response in comfort sensation at the three environmental temperatures.

  • PDF

Computational Study of The Pulse Waves Discharged From The Open End of a Duct (관 출구로부터 방출되는 펄스파의 수치해석적 연구)

  • Kim, H.D.;Kim, H.S.;Kweon, Y.H.;Lee, D.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.355-360
    • /
    • 2001
  • This study addresses a computational work of the impulsive wave which is discharged from the open end of a pipe. An initial compression wave inside the pipe is assumed to propagate toward atmosphere. The over pressure and wave-length of the initial compression wave are changed to investigate the characteristic values of the impulsive wave. The second order total variation diminishing (TVD) scheme is employed to solve the axisymmetric, compressible, unsteady Euler equations. The relationship between the initial compression wave form and impulsive wave is characterized in terms of the peak pressure of the impulsive wave and its directivity. The results obtained show that for the initial compression wave of a large wave-length the peak pressure of the impulsive wave does not depend on the over pressure of the initial compression wave, but for the initial compression wave of a very short wave-length, like a shock wave, the peak pressure of the impulsive wave is increased with an increase in the over pressure of the initial compression wave. The directivity of the impulsive wave to the pipe axis becomes significant with a decrease in the wave-length of the initial compression wave.

  • PDF

A Study on Falling Pressure Surge of ABS Using High Frequency PWM Control (고주파수 PWM제어를 이용한 ABS의 맥동 저감에 관한 연구)

  • Lee, Yong-Joo;Kim, Byeong-Woo;Park, Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.3
    • /
    • pp.38-44
    • /
    • 2003
  • The solenoid valve in ABS hydraulic modulator is a two directional on-off valve and is controlled by around 100Hz high speed pulse width modulation. When the valve is switched from open state to closed state, noise and vibration due to pressure surge phenomena in the hydraulic line and wheel cylinder are made. In this study, we identify Pressure surge phenomenon in the braking process of a ABS, and investigate the way to reduce the phenomenon. For the purpose of theoretical analysis on the pressure surge in the closed state hydraulic line, characteristic curve method based on wave equation was utilized. To reduce the surge, high frequency control of 20kHz was attempted. The result showed that the surge pressure of 50% was reduced compared to one observed in the low frequency control. Duty variation of high frequency can control current of solenoid valve and prevent sudden change of displacement.

Study on the Atmospheric Plasma Characteristics of Dielectric Barrier Discharge due to a Variation of the Duty Ratio of Pulse Modulation (펄스변조의 듀티비 변경에 따른 DBD 대기압 플라즈마 특성 연구)

  • Park, Jong-in;Hwang, Sang-hyuk;Jo, Tae Hoon;Yun, Myoung Soo;Kwak, Hyoung sin;Jin, Gi nam;Jeon, Buil;Choi, Eun Ha;Kwon, Gi-Chung
    • Korean Journal of Materials Research
    • /
    • v.25 no.11
    • /
    • pp.616-621
    • /
    • 2015
  • Atmospheric pressure plasma is used in the biological and medical fields. Miniaturization and safety are important in the application of apply atmospheric plasma to bio devices. In this study, we made a small, pocket-sized inverter for the discharge of atmospheric plasma. We used pulse power to control the neutral gas temperature at which the, when plasma was discharged. We used direct current of 5 V of bias(voltage). The output voltage is about 1 to 2 kilo volts the frequency is about 80 kilo hertz. We analyzsed the characteristics of the atmospheric plasma using OES(Optical emission spectroscopy) and the Current-Voltage characteristic of pulse power. By calculating of the current voltage characteristics, we were able to determine that, when the duty ratio increased, the power that actually effects the plasma discharge also increased. To apply atmospheric plasma to human organisms, the temperature is the most important factor, we were able to control the temperature by modulating the pulse power duty ratio. This means we can use atmospheric plasma on the human body or in other areas of the medical field.

Ecophysiological Interpretations on the Water Relations Parameters of Trees(IX) - Measurement of the Transpiration Rate by the Heat Pulse Method in a Quercus mongolica Stand - (수목(樹木)의 수분특성(水分特性)에 관(關)한 생리(生理)·생태학적(生態學的) 해석(解析)(IX) - Heat pulse법(法)을 이용(利用)한 신갈나무임분(林分)의 증산속도(蒸散速度) 측정(測定) -)

  • Han, Sang Sup;Kim, Sun Hee
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.2
    • /
    • pp.288-299
    • /
    • 1996
  • This is the basic study to investigate the amount of transpirational water loss in thrifty mature Quercus mongolica stand by the heat pulse method. The differences of heat pulse velocity by direction and depth, differences of heat pulse velocity by dominant, codominant and suppressed trees, diurnal changes of heat pulse velocity due to the change of leaf water potential, vapor pressure deficit and radiation, and sap flow path way in sapwood by dye penetration were measured in stems. Finally the amounts of daily and annual transpiration in stand were calculated by the heat pulse velocity. The results obtained were summarized as follows : 1. Relationship between heat pulse velocity(V) and sap flow rate(SFR) was obtained as a equation of SFR=1.37V. 2. The sap flow rate was high in the order of dominant, codominant, and suppressed trees. The daily heat pulse velocity changed with radiation, temperature and vapor pressure deficit. 3. The heat pulse velocity showed the similar diurnal variation as the leaf water potential change. 4. The heat pulse velocity showed the highest value in May(4.0cm/hr in average), the lowest one in July(2.9cm/hr in average). 5. The heat pulse velocity in the same stem presented the highest value in the northern direction, medium in western, and the lowest in southern and eastern. 6. The heat pulse velocity in stem was highest in 0.5cm, medium in 1.0cm, and lowest in 1.5cm depth from the surface of stem. 7. The sap flow path way in stem showed sectorial straight ascent pattern in four sample trees. 8. The amount of sap flow(SF) was presented as a equation of $SF=1.37A{\cdot}V$(A: the cross-sectional area of sapwood, V: heat pulse velocity), and especially SF was larger in dominant tree than codominant and suppressed trees. 9. The amount of daily transpiration was 5.6ton/ha/day, and its composition ratio was 72% at day and 28% at night. 10. The amount of stand transpiration per month was largest in May(168ton/ha/month), lowest in July(125ton/ha/month). The amount of stand transpiration per year was 839ton/ha/year.

  • PDF

The Effect of Relaxation Technique on Reduction of Postoperative Pain (이완술 사용이 수술후 동통 감소에 미치는 영향)

  • 박정숙
    • Journal of Korean Academy of Nursing
    • /
    • v.15 no.1
    • /
    • pp.76-96
    • /
    • 1985
  • Postoperative pain is one of the most frequently occurred pain in hospitals, but it has been underestimated because it is only a part of postoperative physiological Process and may disappear in time. It is necessary that nurses me the relaxation technique, planning and implementing by themselves independently, to reduce this postoperative pain. This study is aimed at showing the effect of relaxation technique on reduction of postoperative pain, and exploring the factors influencing postoperative. pain Fifty-seven patients with abdominal surgery who admitted in attacked D Medical Center to K University in Daegu have been studied. Of them twenty-nine were experimental group and the remaining twenty-eight were control group. This study has been conducted for collecting data through interviews and observation from August 23 to October 24, 1984. The tools of this study were two kinds: Postoperative Pain Scale is obtained from a review of references by the researcher, and relaxation technique, designed to use postoperative setting adequately, is also obtained from a review of references by the researcher. After confiriming no significant differences between the two groups, the hypotheses were statistically verified by x²-test, t-test, and pearson Correlation Coefficient. The results of this study are summerized as follows; * The nam hypothesis that the experimental group who use relaxation technique will have less degree of postoperative pain than the control group who don't use relaxation technique is devided into three sub-hypotheses. 1. The first sub-hypothesis that the experimental group will have less score of postoperative pain than control group was accepted (t=7.810, p <.01). Even with controlling pain threshold, showing difference in some degree between the two groups, the experimental group has less score of postoperative pain than the control group. Therefore this confirms the acceptance of the first sub-hypothesis more strongly. 2. The second sub-hypothesis that the expermental group will have less frequency of analgesics than the control group is accepted (x²=9.85, p <.01). 3. The third sub-hypothesis that the experimental group will have less variation of pulse, respiration, and blood pressure between pre End post operative periods than the control group is rejected. So this hypothesis is reverified through comparing the variation of pulse, respiration, and blood pressure between pre and post changing Position to measure the pure effect of relaxation technique. pulse and respiration is significantly lowered in the experimental group (t=7.209, p<.01, t=3.473, p<.01), but systolic and diastolic blood pressure is not different significantly between the two groups (t= 1.309, p>.05, t=1. 727 p>.05). Therefore the third sub-hypothesis is partially accepted. Conclusively, the researcher thinks that it is necessary that nurses should provide patients with relaxation technique to reduce postoperative pain, and to increase independence of nursing.

  • PDF

Measurement of the discharge characteristics of liquid nitrogen at atmospheric pressure by personal computer system (컴퓨터 시스템에 의한 대기압하(大氣壓下)에서 액체질소($LN_2$)의 방전특성측정(放電特性測定))

  • Ju, Jae-Hyun;Lee, Young-Gun;Kim, Sang-Ku;Jeon, Young-Ju;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1530-1532
    • /
    • 1994
  • This paper describes the discharge characteristics of liquid nitrogen for plane-plane, needle-plane electrode at variation of gap spacing at atmospheric pressure. The important results obtained from this study are as follows. (1) Breakdown voltage of $LN_2$ for needle-plane electrode is higher than that of for plane-plane electrode and discharge duration tine is longer with increase of gap spacing at atmospheric pressure. (2) The formation of bubbles by evaporation is observed in spite of non-applying source at atmospheric pressure and the creation of corona confirmed for plane-plane electrode results from the bubbles. (3) The applied voltage-discharge magnitude( V-Q) characteristics of $LN_2$ showed hysteresis and the discharge magnitude decreasing and corona voltage increasing proportional to the pulse per second at atmospheric pressure.

  • PDF

Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference (전달 시간차 방식 초음파 가스 유량계)

  • 박상국;황원호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

Propagation Characteristics of Pressure Pulse of Unsteady Flow in n Hydraulic Pipeline (유압관로에서 비정상유동의 압력전파특성)

  • Yu, Yeong-Tae;Na, Gi-Dae;Kim, Ji-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.1-11
    • /
    • 2002
  • Flow of fluid has been studied in various fields of fluid engineering. To hydraulic engineers, the unsteady flow such as pulsation and liquid hammering in pipes has been considered as a serious trouble. So we are supposed to approach the formalized mathematical model by using more exact momentum equation for fluid transmission lines. Most of recent studies fur pipe line have been studied without considerations of variation of viscosity and temperature, which are the main factors of pressure loss causing the friction of fluid inside pipe line. Frequency response experiments are carried out with use of a rotary sinusoidal flow generator to investigate wave equation take into account viscosity and temperature. But we observed that measured value of gains are reduced as temperature increased. And it was respectively observed that the measured value of gains are reduced and line width of gain is broadened out, when temperature was high in the same condition. As we confessed, pressure loss and phase delay are closely related with the length, diameter and temperature of pipe line. In addition, they are the most important factors, when we decide the momentum energy of working fluid.

Development of Pressure Sensor on Polymer Substrate for Real-time Pulse and Blood Pressure Measurements (실시간 맥박 및 혈압 측정을 위한 폴리머 기판 압력센서 개발)

  • Kim, Jin-Tae;Kim, Sung Il;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.669-676
    • /
    • 2013
  • In this study, we introduce a polymer(polyimide) based pressure sensor to measure real-time heart beat and blood pressure. The sensor have been designed with consideration of skin compatibility of material, cost effectiveness, manufacturability and wireless detection. The designed sensor was composed of inductor coils and an air-gap capacitor which generate self-resonant frequency when electrical source is applied on the system. The sensor was obtained with metalization, etching, photolithography, polymer adhesive bonding and laser cutting. The fabricated sensor was shaped in circular type with 10mm diameter and 0.45 mm thickness to fit radial artery. Resonant frequencies of the fabricated sensors were in the range of 91~96 MHz on 760 mmHg pressurized environment. Also the sensor has good linearity without any pressure-frequency hysteresis. Sensitivity of the sensor was 145.5 kHz/mmHg and accuracy was less than 2 mmHg. Real-time heart beat measurement was executed with a developed hand-held measurement system. Possibility of real-time blood pressure measurement was showed with simulated artery system. After installation of the sensor on skin above radial artery, simple real blood pressure measurement was performed with 64 mmHg blood pressure variation.