• 제목/요약/키워드: pulse number

검색결과 719건 처리시간 0.022초

맥솔(脈率) 측정방법(測定方法)의 신뢰도(信賴度) 분석(分析) (The Analysis on the Reliability of Measuring Pulse-Respiration Ratio)

  • 김동훈;양동훈;허웅;박영재;박영배
    • 대한한의진단학회지
    • /
    • 제9권2호
    • /
    • pp.123-144
    • /
    • 2005
  • Objectives: Pulse-Respiration Ratio has been used for estimating subject's Han-Yeol [寒熱] status since it mentioned in suwen [素問]. In practicing Pulse-Respiration Ratio over 5 means the status of Yeol [熱], Pulse-Respiration Ratio below 3 means the status of Han [寒]. We performed this study to examine the Optimum Standard for Measuring Pulse-Respiration Ratio on the Basis of Repeatability and Reproducibility. Methods: After subject's 5 minutes rest we measured subject's ECG, respiration pattern, EEG, EMG simultaneously. In this research examiner's number is two, subject's number is four, and the number of repeat is two. We calculated Pulse-Respiration Ratio through dividing Respiration cycle average by Pulse cycle average according to each standard including time section, $EEG(relative-{\alpha}$ density, $relative-{\beta}$ density, ${\alpha}/{\beta}$ and EMG. We analyzed these data through Gage R&R study using MINITAB 13.20 program and considered the results of below 30 %R&R and over 4 Number of Distinct Categories to have a significance. Results: 1. In the applying of time standard, Pulse-Respiration Ratio from section 3, 4, 6, 8 had a significant meaning in the aspect of Repeatability and Reproducibility. 2. In the applying of $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$, EMG(E I) standard, there was no significant results. 3. In the applying of time standard(section 5, 6, 7), $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$ and EMG(E I) standard simultaneously, Pulse-Respiration Ratio from ${\alpha}/{\beta}$ in section 6, ${\beta}$ I in section 8 had a significant meaning in the aspect of Repeatability and Reproducibility. Conclusions: We can suggest the Optimum Standard for Measuring Pulse-Respiration Ratio on the basis of Repeatability and Reproducibility as followings; 1. Pulse-Respiration Ratio Measuring time should be at least 15 minutes. 2. Applying of time(section 6, 8) and $EEG({\beta}$ I, ${\alpha}/{\beta})$ standard simultaneously is recommended considering reliability and validity but more study is needed. 3. EMG(E I) may be helpful to detect the segment of physical rest and exclude artifacts but more study is needed.

  • PDF

Evaluating the pull-out load capacity of steel bolt using Schmidt hammer and ultrasonic pulse velocity test

  • Saleem, Muhammad
    • Structural Engineering and Mechanics
    • /
    • 제65권5호
    • /
    • pp.601-609
    • /
    • 2018
  • Steel bolts are used in the construction industry for a large variety of applications that range from fixing permanent installations to temporary fixtures. In the past much research has been focused on developing destructive testing techniques to estimate their pull-out load carrying capacity with very little attention to develop non-destructive techniques. In this regards the presented research work details the combined use of ultrasonic pulse velocity and Schmidt hammer tests to identify anchor bolts with faculty installation and to estimate their pull-out strength by relating it to the Schmidt hammer rebound value. From experimentation, it was observed that the load capacity of bolt depends on its embedment length, diameter, bond quality/concrete strength and alignment. Ultrasonic pulse velocity test is used to judge the quality of bond of embedded anchor bolt by relating the increase in ultrasonic pulse transit time to the presence of internal pours and cracks in the vicinity of steel bolt and the surrounding concrete. This information combined with the Schmidt hammer rebound number, R, can be used to accurately identify defective bolts which resulted in lower pull-out strength. 12 mm diameter bolts with embedment length of 70 mm and 50 mm were investigated using constant strength concrete. Pull-out load capacity versus the Schmidt hammer rebound number for each embedment length is presented.

A Novel Frequency-to-Digital Converter Using Pulse-Shrinking

  • Park, Jin-Ho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.220-223
    • /
    • 2003
  • In this paper, a new frequency-to-digital converter without an analog element is proposed. The proposed circuit consists of pulse-shrinking elements, latches and D flip-flops, and the operation is based on frequency comparison by the pulse-shrinking element. In the proposed circuit, the resolution of digital output can be easily improved by increasing the number of the pulse-shrinking elements. The FDC performance is improved in viewpoints of operating speed and chip area. In designed FDC, error of frequency-to-digital conversion is less than 0.1 %.

사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구 (Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system)

  • 박승욱;김태형;이효우;하현철;정재훈
    • 한국산업보건학회지
    • /
    • 제18권3호
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

핵치환에 의한 Clone Animal의 생산에 관한 연구 I. 생쥐 수정란의 세포막 융합과 난모세포의 활성화에 미치는 전기자극의 효과 (Production of Clone Animals by Nuclear Transplantation I. Effects of Electrostimulation on Membrane Fusion of Embryos and Activation of Oocytes in Mouse)

  • 이상진;구덕본;이상민;박흠대;정순영;정길생
    • 한국가축번식학회지
    • /
    • 제18권3호
    • /
    • pp.217-228
    • /
    • 1994
  • These experiments were carried out to establish the optimal condition of electrostimulatin inducing cell fusion and oocyte activation for nuclear transplantation in mouse embryos. Eggs selected for cell fusion or activation by electrostimulation were equilibrated for 5~10 min. in 0.3M sucrose solution and electrostimulated for 60$\mu$sec using 1 pulse of 60, 70, 80, 90 or 100 volts DC with electrodes 0.2 mm apart. Then they were cultured in 20${mu}ell$ dropsof Tyrode's solution. The results of these experiments are as follows : 1. When one pulse of 60, 70, 80, 90 or 100 volts DC for 60$\mu$sec were applied to 2-cell embryos for fusion of blastomeres, fusion rates were 50.0, 81.7, 91.7, 100 and 100%, respectively ; and developmental rates of fused embryos to blastocyst were 76.7 to 81.5%. Higher fusion rates were observed in 90V and 100V. 2. The average cell number in fused embryos developed to blastocyst was about half of the cell number in diploid controls; and the cell number decreased with increasing of voltages. 3. When pulse numbers were increased, fusion rates improved, but developmental rates were not signficiantly different from the group for which the number of pulse was not increased. And the cell number of blastocyst decreased even more. 4. Oocytes aged for 6hrs after ovulation were electrostimulated for oocyte activation by the same method used for cell fusion. Rates of oocyte activated by electrostimulation were 45.3 to 60.4%, and fragmentation rates were 7.5~15.1%. The lysis rates were 17.0~34.0%. The results of these experiments indicate that the optimal condition for achieving cell fusion and activation is 1 pulse, duration 60$\mu$sec in 90 Volt. The results also show that this condition is suitable for nuclear transplantation using mouse eggs.

  • PDF

나선형 블룸라인 PFL을 이용한 50 ns 펄스폭의 고전압 펄스 발생 (Generation of a High Voltage Pulse of 50 ns Pulse Duration using a Helical Blumlein Pulse Forming Line)

  • 노영수;진윤식
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.786-791
    • /
    • 2013
  • A high voltage pulse generator based on the Blumlein pulse forming line (PFL) was fabricated to produce a voltage pulse whose peak value is ~300 kV and pulse duration is ~50 ns. Three cylindrical electrodes, such as inner, middle, and outer electrodes, are concentrically placed to make a compact PFL. To increase the pulse duration of the output pulse without any change of the size of the generator, the middle electrode is replaced by a helical strip electrode. To determine the radius of the helical electrode, the impedance of the helical Blumlein PFL is calculated using an approximate formula where the dispersive property of the helical Blumlein PFL is not considered. The dependence of the impedance on the frequency is computed by a commercial program. The number of turns in the helical electrode is decided to provide a demanded pulse duration. The experimental result shows that the helical Blumlein PFL is capable of making a high voltage pulse of ~50 ns pulse duration.

맥동관 내부의 열전달에 관한 실험적 연구 (Experimental study on the transfer in pulse tube)

  • 김민규;남관우;정상권;장호일;정은수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.45-50
    • /
    • 2000
  • The present study has been conducted to observe the heat transfer under pulsating pressure and oscillating flow. The experimental apparatus was fabricated to measure the gas temperature, the wall temperature. the pressure and the instantaneous heat flux inside the pulse tube. The measured gas temperature and heat flux must be calibarated to compensate their finite time constant in the oscillating flow conditious. The experiment was performed from 1 Hz to 5 Hz. The phase difference between the instantaneous heat flux and the gas-wall temperature difference was clearly observed. The experimental heat fluxes were compared to the theroretical correlations such as Complex Nusselt Number Model(CNNM) and Variable Coefficient Model(CVM). The heat flux predisted by CNNM was always greater than that of VCM. The experiment confirmed the valisity of the VCM for the instantaneous heat flux under the pulsating pressure and oscillating flow in the warm end of the pulse tube.

  • PDF

Optimal condition for efficient DNA transfer in filamentous cyanobacteria by electroporation

  • Poo, Ha-Ryoung
    • Journal of Microbiology
    • /
    • 제35권3호
    • /
    • pp.181-187
    • /
    • 1997
  • Filamentous cyanobacteria are an ecologically important group of bacteria because they are able to provide both organic carbon fixed nitrogen that can support the nutritional requirements for other microorganisms. Because of their prokaryotic nature, they can also be used as potentially powerful model systems for the analysis of oxygenic photosynthesis and nitrogen fixation. Gene transfer is an indispensable procedure for genetic analysis of filamentous cyanobacteria. Electroporation was used to introduce foreign DNA into cyanobacterial cells. In experiments designed to optimize the electroporation technique, the effects of the field strength (amplitude of pulse) and time constant (duration of pulse), DNA concentration and host restriction/modification of DNA on the efficiency of electro-transformation were investigated. The results of this research revelaed that a high voltage pulse of short duration was effective for the electro-transformation of Anabaene sp. M131. The maximal number of transformants was obtained at 6 kV/cm with a pulse duration of 5 msec. The efficiency of electro-transformation was also sensitive to concenetration of DNA; even small amounts of DNA (0.01 .mu.g/ml) were able to gie a large number of transformants (1.0 * 10$\^$3/ cfu/ml).

  • PDF

Step Pulse Shaping Technique for Nd:YAG Laser Using a Multi-Switching Method

  • Kwak, Su-Young;Park, Jin-Young;Kim, Su-Weon;Min, Byoung-dae;Chung, Hyun-ju;Kim, Hee-je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권2호
    • /
    • pp.55-59
    • /
    • 2004
  • Throughout manufacturing processes, pulse shaping is required for material processing and it is regarded as an important (actor according to the specific characteristics of materials. Therefore, this study suggests a highly appropriate pulse shaping technique using a multi-switching method. This is a pulse superposition method in which one flash lamp can consecutively turn on by the double switching of the discharging system. It is possible to construct a variety of pulse shapes and pulse widths by the consecutive trigger of the silicon-controlled rectifiers (SCR) of a PIC (program integrated circuit) one-chip microprocessor. The use of this technique can provide a number of advantages to people who require suitable pulse shaping for particular applications such as welding, cutting, and drilling.

참개구리(Rana nigromaculata)의 짝짓기 소리의 구조와 변이 (Mating Call Structure and Variation of the Frog Rana nigromaculata)

  • 박시룡;양서영
    • The Korean Journal of Ecology
    • /
    • 제20권6호
    • /
    • pp.423-438
    • /
    • 1997
  • The structure and variation of the mating call in Rana nigromaculata was studied in a population at Da-rak, Chong-won, Chung-buk (36$\circ$ 37' latitude, 127$\circ$ 21' longitude) in Korea. The mating call consists of 3 to 8 pulse groups divided by clear silent intervals. Each pulse group is also composed of fine pulses. Temperature and body size affect the temporal and spectral characteristics of the mating call. Pulse, pulse group repetition rate and dominant frequency rise with increasing temperature, whereas pulse grouprepetition rate and dominant frequency decrease with increasing body size. A playback experiment was designed to establish the effect of a potential intruder on male calling. During the stimulus periods, resident males markedly decreased the pulse repetition rate, and icreased the rate of pulse groups, dominant frequency, and the number of call groups. This results indicate that this species responds in a graded fashion when interacting with other individuals.

  • PDF