• Title/Summary/Keyword: pulse evaluation

Search Result 499, Processing Time 0.034 seconds

Psychological and Physiological Stress Improvement Effect of Gardening Program

  • Seung-hoon Hong;Hyukjae Lee
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.3
    • /
    • pp.225-236
    • /
    • 2024
  • This study aimed to propose a gardening program that can be introduced in elderly care facilities and is effective by inducing active activities of the elderly, conducting a gardening program that can lead to healing functions and social activities, and identifying psychological and physiological changes before and after the gardening program is implemented. In order to achieve the above objectives, we conducted 30 gardening programs for 20 elderly people living at Chungju Senior Nursing Home from May 2023 to October of the same year to create three gardens. And as a result of evaluating the results of the gardening program, the psychological evaluation showed statistically improved results in most evaluation items, and the EEG improved to a statistically significant number as the gardening program was carried out in the measurement of mental and physical stress using EEG and pulse waves.

The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants

  • Kim, Ji-Hyun;Herr, Yeek;Chung, Jong-Hyuk;Shin, Seung-Il;Kwon, Young-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.5
    • /
    • pp.234-241
    • /
    • 2011
  • Purpose: One of the most frequent complications related to dental implants is peri-implantitis, and the characteristics of implant surfaces are closely related to the progression and resolution of inflammation. Therefore, a technical modality that can effectively detoxify the implant surface without modification to the surface is needed. The purpose of this study was to evaluate the effect of erbium-doped: yttrium, aluminium and garnet (Er:YAG) laser irradiation on the microstructural changes in double acid-etched implant surfaces according to the laser energy and the application duration. Methods: The implant surface was irradiated using an Er:YAG laser with different application energy levels (100 mJ/pulse, 140 mJ/pulse, and 180 mJ/pulse) and time periods (1 minute, 1.5 minutes, and 2 minutes). We then examined the change in surface roughness value and microstructure. Results: In a scanning electron microscopy evaluation, the double acid-etched implant surface was not altered by Er:YAG laser irradiation under the condition of 100 mJ/pulse at 10 Hz for any of the irradiation times. However, we investigated the reduced sharpness of the specific ridge microstructure that resulted under the 140 mJ/pulse and 180 mJ/pulse conditions. The reduction in sharpness became more severe as laser energy and application duration increased. In the roughness measurement, the double acid-etched implants showed a low roughness value on the valley area before the laser irradiation. Under all experimental conditions, Er:YAG laser irradiation led to a minor decrease in surface roughness, which was not statistically significant. Conclusions: The recommended application settings for Er:YAG laser irradiation on double acid-etched implant surface is less than a 100 mJ/pulse at 10 Hz, and for less than two minutes in order to detoxify the implant surface without causing surface modification.

Assessment of Ultrasonic Pulse Velocity Method for Early Detection of Frost Damage in Concrete (콘크리트의 초기동해 진단을 위한 초음파 속도법의 적용 가능성 평가)

  • Moon, Sohee;Lee, Taegyu;Choi, Heesup;Choi, Hyeonggil
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.2
    • /
    • pp.193-202
    • /
    • 2024
  • This research delves into the evaluation of the suitability of ultrasonic pulse velocity as a diagnostic tool for early detection of frost damage in concrete. The investigation involves the measurement of compressive strength and ultrasonic pulse velocity concerning the depth of freezing for individual mortar specimens, followed by an analysis of their microstructure and their interrelation. The findings indicate a consistent decrease in both compressive strength and ultrasonic pulse velocity with increasing freezing depth. Furthermore, a correlation between compressive strength and ultrasonic pulse velocity concerning the depth of early frost damage is established. Consequently, the study asserts the potential of utilizing the ultrasonic pulse velocity method for early detection of frost damage in concrete, with prospects for quantifying the depth of damage through further research endeavors.

A Study on Evaluation of Human Arousal Level using PPG Analysis (PPG(Photoplethysmography)분석을 이용한 각성도 평가에 관한 연구)

  • Kim, Chi-Jung;Whang, Min-Cheol;Kim, Jong-Hwa;Woo, Jin-Cheol;Kim, Yong-Woo;Kim, Ji-Hye
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.113-120
    • /
    • 2010
  • This research is to evaluate the arousal level by using cardiovascular response. PPG was used in this study as one of the method of measuring it rather than ECG (Electrocardiography) for the purpose of solving ergonomic problem of sensing. The participants were in the age group of 20 (mean=24, standard deviation=1.25): five men and five women. Each experiment composed with four identical sets. First, a black screen was displayed for 30 second rest. Then, the prepared 6 pair images were randomly presented for 10 second stimulation and for 30 second non-stimulation. PPG was measured on the earlobes of experimenters at 200Hz sampling frequency. PPG amplitude, PPI(Pulse to Pulse Interval), and PRV(Pulse Rate Variability) were analyzed according to arousal level. T-test was performed to compare between the PPG variables of rest and relaxation, rest and arousal, and relaxation and arousal. Relative to the rest state, PPG amplitude decreased in relaxed state and increased in aroused state. Relative to the rest state, PPI decreased in both emotional states. However, more significant decline was observed in aroused state. PRV's LF and HF were used in the form of LF/HF to compare between the relaxed and the aroused state. Therefore, PPG signal showed significant differences between relaxed and aroused state. In conclusion, evaluation of human arousal level used in the PPG analysis demonstrated that PPG has better usability and comforter measurement than ECG and is clearly an alternative method of measuring arousal level.

Influence of Steel Bar on Ultrasonic Velocity in Concrete (콘크리트 속의 철근이 초음파 속도에 미치는 영향)

  • Kim, Do-Hyun;Rhim, Hong-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.122-123
    • /
    • 2014
  • Measurement of the strength of concrete is an important indicator of the safety of the fresh as well as old concrete structures. It is possible to evaluate the strength of the concrete by means of an ultrasonic velocity method which is a kind of non-destructive inspection method for safety diagnostic evaluation of the building structures with aging. Steel embedded in the concrete and age of the concrete may affect ultrasonic pulse velocity. In order to accurately assess the strength of the concrete, it is necessary to understand rebar embedded in the concrete, steel shapes in various forms which effect ultrasonic pulse velocity. In this study, by measuring the velocity of ultrasonic waves generated when the waves pass through the ultrasonic pulse in a direction perpendicular to the reinforcing bars embedded in concrete, the effect of reinforcing bars on ultrasonic velocity accurately was verified and used to estimate the strength of the concrete.

  • PDF

A Study on Evaluation of Jamming Performance on SAR Satellite (SAR 위성에 대한 재밍 효과 분석)

  • Lee, Young-Joong;Kim, In-Seon;Park, Joo-Rae;Kwak, Hyun-Kyu;Shin, Wook-Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.252-257
    • /
    • 2010
  • SAR has pulse compression gain through the process including range and azimuth. Efficient jammers against the SAR with simulated elements are evaluated in the view of power and SAR image. In this paper, J/S is analysed for SAR with RF propagation equation firstly. Several jamming signals on SAR signal are made into SAR image through pulse compression process. Objective jamming performance is evaluated using euclidean distance.

Evaluation of 300kJ Capacitor Bank Module for High Current Pulse Shaping (대전류 펄스 성형을 위한 300kJ급 커패시터뱅크 모듈의 특성 평가)

  • Hwang, Dong-Won;Lee, Hong-Sik;Jin, Yun-Sik;Cho, Chu-Hyun;Kim, Jong-Soo;Rim, Geun.Hee;Park, Won-Zoo;Kim, Jin-Sung;Jung, Jae-Won;Chu, Jeung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2086-2088
    • /
    • 2000
  • Key elements of in the development Electro-Thermal-Chemical propulsion (ETC) are high current pulse shaping, switching and storage bank device with high energy density 300kJ pulse power capacitor bank module for ETC application is designed and fabricated. The tested result are described.

  • PDF

Evaluation of Local Loss Coefficients for Different Waveguide-Below-Cutoff (WBC) Arrays of Electromagnetic Pulse (EMP) Shied in Buildings (도파관 배열에 의한 국부저항계수 산정)

  • Pang, Seung Ki;Chae, Young Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.7
    • /
    • pp.366-372
    • /
    • 2017
  • The objective of this study was to characterize Waveguide-Blow-Cutoff (WBC) array for Electromagnetic Pulse (EMP) shield in air duct or water pipe, the typical pathway of pulse in indoor space with critical electronic device. A numerical investigation with three different WBC designs (circular, rectangular, and hexagonal or honeycomb) was conducted to satisfy recommended shielding effectiveness (SE) levels from 80 dB to 140 dB. Pressure drop between upstream and downstream of EMP shields based on WBC arrays was also investigated to understand air flow feature in air duct of HVAC system. Results showed that honeycomb geometry outperformed other shapes in terms of reducing the depth of EMP shield, thus providing better air flow in duct path with lower local loss coefficient in HVAC system under SE requirements.