• Title/Summary/Keyword: pulse duration

Search Result 509, Processing Time 0.023 seconds

The Femto Second Laser Induced Ablation on the Titanium Alloy for Various Beam Overlap Ratio (빔 중첩율에 따른 티타늄 합금의 펨토초 레이저 어블레이션)

  • Chung, Il-Young;Kang, Kyung-Ho;Kim, Jae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.17-23
    • /
    • 2010
  • Titanium alloy is one of the hard processing materials made by the traditional manufacturing method because of the excellent mechanical strength. Ablation of titanium alloy is investigated by using a femtosecond laser which is a regenerative amplified Ti:sapphire laser with 1kHz repetition rate, 184fs pulse duration time and 785nm wavelength. Experiments are carried out under various ablation conditions with different pulse overlap ratios for the rectangular shape and micro hole. Test results show that the ablation characteristic according to pulse overlap ratio of titanium alloy seems to be as non-linear type at the different zone of energy fluence. The optimal condition of rectangular shape processing is obtained at the laser peak power 1.3mW, pulse overlap ratio of 90%, beam gap of $1\;{\mu}m$. The micro hole has a good quality from the pulse overlap ratio of 99% at the same laser peak power. With the optimal processing condition, the fine rectangular shape and micro hole without burr and thermal damage are achieved.

Error Analysis of Reaction Wheel Speed Detection Methods Due to Non-uniformity of Tacho Pulse Duration (타코 펄스 불균일성이 존재하는 반작용휠의 속도측정 방법 오차 분석)

  • Oh, Shi-Hwan;Yong, Ki-Lyuk
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.92-97
    • /
    • 2009
  • Two conventional speed detection methods (Elapsed-time method and Pulse-count method) are analyzed and compared for a high speed motor with digital tacho pulse with non-uniformity. In general, the elapsed-time method usually has better performance than a pulse-count method in case sufficiently high speed clock is used to measure the time difference. But if a tacho pulse non-uniformity exists in the reaction wheel - most of reaction wheel has a certain amount of non-uniformity - the accuracy of the elapsed-time method is degraded significantly. Thus the performance degradation is analyzed with respect to the level of non-uniformity of tacho pulse distribution and an allowable bound is suggested.

  • PDF

Optimal Characteristics of a Long-pulse $CO_2$Laser by Controlling SCR Firing Angle in AC Power Line

  • Noh, Ki-Kyung;Kim, Geun-Yong;Chung, Hyun-Ju;Min, Byoung-Dae;Song, Keun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.304-308
    • /
    • 2002
  • We demonstrate a simple pulsed $CO_2$ laser with millisecond long pulse duration in a tube at a low pressure of less than 30 Torr. The novel power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply doesn't need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. To control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of SCR(Silicon Controlled Rectifier) gate is varied from 30。 to 150。. A ZCS (Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control precisely the gate signal of the SCR. The maximum laser output of 35 W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60 Hz, and a SCR gate firing angle of 90。 . In addition, the resulting laser pulse width is approximately 3㎳(FWHM). This is a relatively long pulse width, compared with other repetitively pulsed $CO_2$ lasers.

Effects of San-Yin-Jiao (SP6) Acupressure on Anxiety, Pulse and Neonatal Status in Women during Labor (삼음교(SP6) 지압이 산부의 불안, 맥박 및 신생아 상태에 미치는 효과)

  • Lee, Mi-Kyeong
    • Women's Health Nursing
    • /
    • v.9 no.2
    • /
    • pp.138-151
    • /
    • 2003
  • Purpose: In the study effects of San-Yin-Jiao (SP6) acupressure on anxiety and pulse during labor, and on neonatal status were examined. Method: The design was a randomized controlled clinical trial with a double-blind method. Data were collected before (pre) and after (post) treatment using structured questionnaire, anxiety scale, pulse rate, umbilical vein pH and Apgar scores. The experimental group received SP6 acupressure for the duration of each uterine contraction over a period of 30 minutes, but the control group received SP6 touch. Results: The anxiety scores between the two groups increased, but the increase was less in the SP6 acupressure group and the difference was statistically significant (p=0.019). Maternal pulse rate was not significantly different immediately after treatment (p=0.711), at 30 and at 60 minutes (p=0.140 ; p=0.108), but while the SP6 acupressure group had a stable pulse, the SP6 touch group showed an increased rate. There was no significant difference between the two groups for umbilical vein pH (p=0.124), and neonatal Apgar score at one and five minutes (p=0.387 ; p=0.979). Conclusion: These findings strengthen the belief that SP-6 acupressure can be used to relieve anxiety during labor with no side effects to either mother or baby.

  • PDF

Modulated Pulse Power Sputtering Technology for Deposition of Al Doped ZnO Thin Film (Al doped ZnO 박막 증착을 위한 모듈레이티드 펄스 스퍼터링)

  • Yang, Won-Kyun;Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.2
    • /
    • pp.53-60
    • /
    • 2012
  • Modulated Pulse Power (MPP) magnetron sputtering is a new high-power pulsed magnetron sputtering (HPPMS) technology which overcomes the low deposition rate problem by modulating the pulse voltage shape, amplitude, and the duration. Highly ionized magnetron sputtering can be performed without arcing because it can be controlled as multiple steps of micro pulses within one overall pulse period in the range of 500-3,000 ${\mu}s$. In this study, the various waveforms of discharge voltage and current for micro pulse sets of MPP were investigated to find the possibility of controlling the strongly ionized plasma mode. Enhanced ionization of the sputtered metal atoms was obtained by OES. Large grained columnar structure can be grown by the strongly ionized plasma mode in the AZO deposition using MPP. In the most highly ionized deposition condition, the preferred orientation of (002) plane decreased, and the resistivity, therefore, increased by the plasma damage.

Pulse Stretching Effect in XeCl Excimer Laser (XeCl 엑시머 레이저에서의 Pulse Stretching 효과)

  • Chu, Hong;Kim, Dong-Hwan;Lee, Soo-Man;John, Young-Min;Choi, Sang-Sam;Park, Dae-Yoon
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.447-451
    • /
    • 1993
  • Long pulse XeCl excimer laser with 150 ns (FWHM) pulse duration is developed using a simple capacitor-charge transfer circuit. We measured the laser pulse width varying the gas mixture ratio and capacitance ratio, which dominantly affect the pulse width. In this way we can easily stretch the pulse width from short pulse to long pulse. The pulse width was stretched by 120 ns as the partial pressure of HC1 and Xe gas was reduced under constant gas mixture ratio ([Xe]/[HCl]= 15), and by varying the capacitance ratio (Cm/Cp) under fixed pressure, the pulse width was stretched by 60 ns.

  • PDF

Sequential Delivery of Neodymium:Yttrium-Aluminum-Garnet and Alexandrite Laser Pulses for Treating Light Brown Seborrheic Keratoses

  • Cho, Sung Bin;Oh, Doojin;Yoo, Kwang Ho
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.24-27
    • /
    • 2019
  • Seborrheic keratoses (SKs) have been treated with non-ablative longpulsed (LP) lasers, including LP 532-nm neodymium (Nd): yttrium aluminum garnet (YAG), LP 695-nm ruby, LP 755-nm alexandrite (Alex), and LP 1,064-nm Nd:YAG lasers, with a pulse durations of 1-300 msec. Dual-wavelength LP 755-nm Alex/1,064-nm Nd:YAG laser systems have been used to remove hair follicles and treat various vascular and pigmented disorders by sequentially delivering two pulses of different wavelengths with interpulse intervals in the millisecond range. This paper reports the case of a female patient with multiple, discrete, light brown SKs on the dorsum of both hands that were treated effectively with one session of dual-wavelength LP 1,064-nm Nd:YAG/755-nm Alex laser treatment. The treatment settings for the LP Nd:YAG laser were comprised of a wavelength of 1,064 nm, fluence of 50 J/cm2, pulse duration of 5 msec, and beam size of 3 mm. The settings for the LP Alex laser were comprised of a wavelength of 755 nm, fluence of 50 J/cm2, pulse duration of 5 msec, and beam size of 3 mm. A hybrid mode was used to automatically deliver LP Nd:YAG and LP Alex laser pulses in succession at interpulse intervals of 20 msec. Six weeks after treatment, the patient exhibited remarkable improvement of the light brown seborrheic keratoses and was satisfied with the results.

Study on the character of the old aged pulsation (고령자의 맥상 특성에 대한 맥파분석적인 연구)

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Ryu, Gyeong-Ho;Gang, Hui-Jeong;Cho, Sang-Won;Park, Young-Jae;Kim, Min-Yong;Oh, Hwan-Sup;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • Objectives: The basis research of aged people's healthcare technology is very important, because our nation goes into an aged society rapidly. Especially in traditional medicine, pulse shapes of aged people were supposed to weak and empty pulse until now, but any objective measurement and compare research do not taken. Methods and Results: Therefore in this study we design observation study to find characteristic of pulse between younger group (age $20{\sim}30$) and elder group (age $43{\sim}80$) in Busan area. We used 3-dimensional pulse analyzer '3-D MAC' (Daeyomedi Co., Ltd.). And major parameters for comparison are 1) pulse height (h1), 2) applied pressure, 3) pulse power (energy), 4) high pressure duration (w) and 5) R-AI. Conclusions: According to analysis result, elder people's pulse has more large value in pulse height, applied pressure and pulse power than younger's that. It reveals that elder people in modernized lifestyle has Yang symptoms as well Yin symptoms. Consequently we need new method to care elder people's health, and this means more important direction than old text book. From now on verification research with objective diagnosis device like 3-D MAC, must be activated to build of evidence in traditional medicine. Cause traditional medicine's spirit of care and prevention is suitable to care elder people's cardiac and cerebral vascular disease those are have close relation with elder people.

  • PDF

High Efficient Metal-oxide Removing Characteristics as Pulse Repetition Rates in the Atmospheric Arc Discharge (펄스반복율의 가변에 의한 대기압 아크방전중의 고효율 금속산화물 제거 특성)

  • 이윤수;송우정;김수원;정종한;김용철;김희제
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.4
    • /
    • pp.179-184
    • /
    • 2003
  • The pulsed power system is widely used for many industries and environments. Generally, we call the "RUST", the reddish brown surface, that was made on iron surface or some other metals, when they are contacted by water and air the main substance of rust is oxide-ionization. In other words, the chemical symbol of rust on iron surface is iron oxide(III) hydrate Fe203.nH2O. In this study, we have designed and fabricated our system which has a compact pulse generator with switching MOSFET. Also we have studied the metal-oxide removing characteristics using in the atmospheric arc discharge. It has been investigated their removing characteristics by the change of charging voltage and pulse repetition rates. From this result, we can find out that the removal area Is increased from 3.80 to 8.04[$\textrm{cm}^2$], when pulse duration is increased from 100[pps] to 400[pps]. 400[pps].

Continuous variation characteristics of pulse width in short cavity dye laser (단공진기 색소레이저의 펄스폭 연속가변 특성)

  • 김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.512-517
    • /
    • 1999
  • Quenched dye laser (QDL), which operates with relaxation oscillation mode, is one of the most powerful source for ultra-short pulse light. In this paper, the output characteristics of QDL is theoretically analyzed by a computer simulation. The QDL is assumed that the laser dye is Rhodamine 6G which has the oscillation wavelength of 590 nrn and that the active length is 5 mm and that the pumping source is XeCllaser which has oscillation wavelength of 308 nm. It is revealed ilim the pulse width of short cavity dye laser reduced less than 1/100 than pumping pulse duration and has the linear relationship with spatial width of pumping beam approximately. In addition, it is revealed that the short cavity dye laser is a powerful candidate of pulse width variable light source, which is adjusted by spatial size of pumping beam_ beam_

  • PDF