Performance Experiment of Electron Beam Convergence Instrument (Finishing 용 전자빔 집속 장치의 성능 실험)

  • Lim, Sun Jong
    • Laser Solutions
    • /
    • v.18 no.3
    • /
    • pp.6-8
    • /
    • 2015
  • Finishing process includes deburring, polishing and edge radiusing. It improves the surface profile of specimen and eliminates the alien substance on surface. Deburring is the elimination process for debris of edges. Polishing lubricates surfaces by rubbing or chemical treatment. There are two types for electron finishing. The one is using pulse beam. The other is using the convergent and scanning electron beam. Pulse type device appropriates the large area process. But it does not control the beam dosage. Scanning type device has advantages for dosage control and edge deburring. We design the convergence and scan type. It has magnetic lenses for convergence and scan device for scanning beam. Magnetic lenses consist of convergent and objective lens. The lenses are designed by the specification(beam size and working distance). In this paper, we evaluate the convergence performance by pattern process. Also, we analysis the results and important factors for process. The important factors for process are beam size, pressure, stage speed and vacuum. These results will be utilized into systematizing pattern shape and the factors.

The electrical and optical properties of Xe plasma in flat lamp (평판형 광원에서 제논(Xe) 플라즈마의 전기적 광학적 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Chio, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.60-64
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important, distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp, we tested the discharge from 100 Torr to 300 Torr pressure, the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Localized Electro-chemical Micro Drilling Using Ultra Short Pulses (초단펄스 전해 국부화를 이용한 미세구멍 가공)

  • 안세현;류시형;최덕기;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.213-220
    • /
    • 2003
  • By the localization of electro-chemical dissolution region, we succeeded in a few micrometer size hole drilling on stainless steel with the radial machining gap of about 1 ${\mu}{\textrm}{m}$. Tens of nanosecond duration voltage pulses were applied between WC micro-shaft and stainless steel in the 0.1 M $H_2SO_4$ solution. Pt balance electrode was used to drill the high aspect ratio micro-hole without generation of Cr oxide layer on the machined surface. The effects of applied voltage, pulse duration, and pulse period on localization distance were investigated according to machining time. We suggested the taper reduction technique especially brought up on blind-hole machining. High quality micro-holes with 8 ${\mu}m$ diameter with 20 ${\mu}m$ depth and 12 ${\mu}m$ diameter with 100 ${\mu}m$ depth were drilled on 304 stainless steel foil. The various hole shapes were also produced including stepped holes and taper free holes.

Electrical and Optical Properties of Xe Plasma in Flat Lamp (평판형 광원에서 제논 플라즈마의 전기적 및 광학적 특성)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.71-74
    • /
    • 2006
  • Discharge of the flat lamp lighting source research arc requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp. we tested the discharge from 100 Torr to 300 Torr pressure. the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Electrical and Optical properties of Xe gas in flat lighting source (제논(Xe) 가스를 사용한 평판형 광원에서의 전기 및 광학적 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2190-2192
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp. we tested the discharge from 100 Torr to 300 Torr pressure. the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

The study of Pulse Transformer for a long-distance Serial Communication (원거리 직렬 통신을 위한 펄스트랜스포머에 관한 연구)

  • Seo, Yong-Won;Yeon, Jun-Sang;Yang, O
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.975-978
    • /
    • 2003
  • 본 논문에서는 주변의 잡음에 의해 통신 환경이 나쁜 시스템에서 통신의 안정성과 고속성과 원거리 통신의 구현을 중점으로 연구하였다 전동차와 같이 Serial Communication을 이용해 차량사이 통신을 하는 경우 주변의 고전압, 고전류의 잡음에 의해 통신 Packet이 파손될 수 있으며 심지어 통신 모들이 파괴되는 현상도 발생한다. 이를 위해 펄스트랜스 포머를 사용해 Hardware의 보호 뿐아니라 고속의 안정적인 통신을 현 할 수 있다. 이는 펄스트랜스 포머의 특성상 하드웨어적으로 분리된 통신선과 통신모듈로 인한 안정성과 원거리 통신을 실현 하였으며 동기통신을 통한 빠른 속도와 FM0, FM1, Manchester 부호 방식에 의한 빠르고 안정한 통신을 제공하기 때문이다.

  • PDF

Self-Preionization Effects of the Nitrogen Laser Using High Voltage Pulse Power Suply (고전압 펄스형 전원을 사용한 질소레이저의 자체 선전리 효과)

  • 이치원;안근옥;추한태;양준묵
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.169-177
    • /
    • 1990
  • We have constructed the laser system which was consisted of a high voltage pulse poner supply, a rapid high voltage spark gap and the Blumlein transmission line circuit of the multiple parallel plate capacitor type, and have studied the self-preionization effect from this laser system without additional modifications. The value of inductive or resistive loading of the laser oscillator seems to have a significant effect on the preionization. The optimal operational condition of this laser system was obtained at the inductive loading of L = I mtl across the laser tube with the spark gap distance of 6.0 mm. nitrogen pressure of 50 torr, when repetition rate was 70 Hz. Stability was found to be better than 2.0Yo and EIP was 867 V/cm.torr.

  • PDF

Pulse Radar Signal Processing Algorithm for Vehicle Detection (차량검지 시스템을 위한 펄스레이더 신호처리 알고리즘)

  • 고기원;우광준
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.5
    • /
    • pp.9-18
    • /
    • 2004
  • This paper presents a vehicle detecting algorithm using microwave system signals. The Proposed algerian decides the breakpoint of signals using the likelihood criteria. The decided signals are segmented and simplified. The proposed searching algorithm uses the Euclid distance from the weighted signal data. We tested the proposed algorithm to compare with the segmentation which is a method using smoothing and edge detection. We confirm that the proposed algorithm is very useful for detecting vehicles by field test.

Effects of Electrode Shape and Electrode Distance on the Properties of Xe Plasma Flat Fluorescent Lamp (LCD Backlight용 FFL(Flat Fluorescent Lamp)의 발광특성에 미치는 전극 형상 및 전극간 거리의 영향)

  • Kang, Jong-Hyeon;Lee, Yang-Kyu;Heo, Sung-Taek;Kim, Sang-Woo;Lee, Dong-Gu;Oh, Myung-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.12
    • /
    • pp.1105-1110
    • /
    • 2008
  • In this study, plasma flat fluorescent lamps (FFLs) having two electrode type structures of surface discharge was fabricated by screen printing and were characterized using spectra-radiometer and square pulse power supply. Two types of FFLs (cross-type and line-type electrode structure) were compared with variation of discharge shape and electrode distance.

UV Detecting according to Corona Discharge Intensity using UV Sensor (자외선 센서를 이용한 코로나 방전 강도에 따른 자외선 검출)

  • Kwag, Dong-Soon;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.78-83
    • /
    • 2014
  • To minimize the financial loss due to power facility malfunction, on-line diagnostic techniques are required to grasp any abnormal state of facilities in the live line as well as devices to diagnose abnormal states of power facility in an easy and prompt manner. This study aims to develop a portable UV detecting system by means of UV sensors for easier and efficient inspection of the degradation state of power facility in a long distance. Accordingly, it includes a simulation of corona discharges that may occur due to degradation of power facility and detection of ultraviolet pulse generation depending on the corona discharge intensity and measuring distance in application of UV sensors. Additionally, the optimal algorithm is determined for its application to the system's degradation diagnosis program based on the measured experiment data.