초음파 펄스 도플러 시스템의 Stationary Conceler에 대한 연구 (A Study on the Stationary Canceler in the Ultrasonic Pulse Doppler System)

  • 김영길
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권1호
    • /
    • pp.47-54
    • /
    • 1985
  • In this paper, clutter in ultrasound pulsed Doppler system is analyzed mathematically. And stationary canceler which reduce the clutter is designed. The operating characteristics of the stationary canceler is investigated in body (in vivo) by audio signal and spectrum analyzer.

  • PDF

3차원 로봇 맥 영상 분석기의 5단계 가압 맥파 분석에 의한 고혈압 환자의 현맥(弦脈) 연구 (A study on wiry pulse in hypertensive patients analyzed at 5 levels of applied pressure using 3 dimensional pulse imaging analyzer)

  • 강희정;권영상;김달래;김경철;임윤경
    • Korean Journal of Acupuncture
    • /
    • 제27권1호
    • /
    • pp.1-12
    • /
    • 2010
  • Objectives: The purpose of this study is to gain the objective indicators for the classification of hypertension by oriental medical pulse diagnosis, through finding out the parameters which can distinguish the pulse of hypertensive patient from that of normal subject, and characterizes the wiry pulse of hypertension. Methods: 30-59 yr, male, 946 healthy volunteers and 35 hypertensive patients were enrolled in this study. All the hypertensive patients were taking medicine to control the blood pressure and the blood pressure of the hypertension group was not statistically different from that of the normal healthy group. Data were acquired using 3 dimensional pulse imaging analyser(DMP-3000, DAEYOMEDI, KOREA) and analysed according to the age bands and the applied pressure levels. Results: 1. RAI/t, w/t and t2/t decreased with the levels of applied pressure and increased with age in the normal healthy group, not in the hypertension group. 2. RAI/t, w/t, t2/t were significantly higher in the hypertension group than the normal healthy group in the 30-age band, and elasticity coefficient was higher in the hypertension group than the normal healthy group in the 40-age band. 3. Researches on the patients without hypotensive agents are needed to figure out whether these parameters are the components of hypertensive wiry pulse. Conclusions: Analysing the radial pulse at 5 applied pressure levels using 3 dimensional pulse imaging analyser may be useful to differentiate the pulses of the hypertensive patients from those of the normal subjects, and characterize the hypertension.

시간영역 측정을 이용한 CPW에서 가우시안 펄스 전송 특성 (Propagation Characteristics of Picosecond Gaussian Pulses in Coplanar Waveguides using Time Domain Measurement)

  • 이승엽;신용섭
    • 한국전자파학회논문지
    • /
    • 제14권11호
    • /
    • pp.1143-1148
    • /
    • 2003
  • CPW와 마이크로스트립선로에서 수십 피코초의 펄스 폭을 갖는 가우시안(Gaussian) 펄스 신호가 진행해 갈 때 기판 및 선로 구조에 따른 분산 및 펄스의 전파 특성을 시간 영역에서 해석하고 측정하였다. 특히, 선로에 사용된 기판의 기본 TE 모드에 대한 차단 주파수( $f_{TE}$ )의 변화에 따른 CPW와 마이크로스트립 선로간의 전송특성을 구하고 비교하였다. 이를 실험적으로 확인하기 위해 $f_{TE}$ 가 다른 기판에 두 가지 50 $\Omega$ 선로를 제작하여 수십 피코초 펄스가 진행되었을 때의 전송 특성을 시간 영역 분석기능이 내장된 VNA(Vector Network Analyzer)를 이용해서 측정하였다.

고압전동기 고정자 권선에서 부분방전 펄스의 전송 (Propagation of Partial Discharge Pulse in High Voltage Motor Stator Windings)

  • 김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권11호
    • /
    • pp.512-515
    • /
    • 2003
  • This paper is to investigate how partial discharge pulse signal can flow in 6.6㎸ motor stator windings. Pulse propagation is experimentally analyzed in stator windings using a variety of frequency-domain techniques. The experiments were performed on two stator windings in the laboratory. Spectrum analyzer(9KHz to 3㎓) with tracking generator(100kHz to 3㎓) was used. Sweep time of the tracking generator was looms. The frequency spectrum of the response signal was detected by active FET probe(1㎓). The active FET probe has a flat amplitude response up to 1㎓ without high frequency attenuation. The stator winding acts as a low-pass filter below 600KHz, the high-frequency components being highly declined. The resonance peaks show about 1.1MHz and 2MHz in low frequency of No. 1 and No. 2 stator windings, respectively. This low-frequency range indicates that attenuation is low. The peaks of partial discharge magnitude show about 900MHz, 1.6MHz in No. 1 stator winding and about 800KHz, 1.4MHz in No. 2 stator winding.

거리 측정용 1-3형 복합압전체 트랜스듀서의 펄스에코 응답 특성 (Pulse-echo response of 1-3 type piezoelectric composite transducers for distance measurement)

  • 최헌일;박정학;이수호;사공건
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권2호
    • /
    • pp.211-216
    • /
    • 1995
  • In this study, the piezoelectric ceramics/polymer composite transducers with 1-3 connectivity have been studied. A piezoelectric ceramics PZT prepared by Wet-Dry Combination method was used as a filler in polymer matrix Eccogel. We've got the pulse-echo response for 1-3 type piezc-electric composite transducers in water. It was shown that the transmitting and receiving sensitivity of 1-3 type piezoelectric composite transducers could be improved in comparison with that- of solid PZT transducers. The reason is for that 1-3 type Piezoelectric composites have low dielectric constant and density. There was in a good agreement between the resonant frequencies calculated from one period and observed results on the Ultrasonic Transducer Analyzer. According to these results we could be figured out the distance in water by virture of the pulse-echo response.

  • PDF

맥의 빠르기, 크기, 깊이에 관한 전통맥진과 기기측정 맥진의 비교 연구 (Comparative Study of Speed, Size and Depth of Pulse on the Traditional Pulse Diagnosis and Pulse Analyzer)

  • 하인영;윤여충;윤대환;최찬헌;이영수;임승일;나창수
    • Korean Journal of Acupuncture
    • /
    • 제28권1호
    • /
    • pp.23-37
    • /
    • 2011
  • Objectives : The pulse diagnosis is an important method in Oriental Medicine. The aim of this study is to measure the similarity of the diagnosis by a traditional method using doctor's hand for feeling of pulse and by pulse diagnosis apparatus using Hwang-Je (HJ) pulse analyser, Hui-Su (HS) pulse analyser on Chon, Kwan and Chuk. Methods : Four korean medical doctors and HJ pulse analyser, HS pulse analyser have measured the speed (遲數), the size (微細弱緩大), and the depth (浮沈) of pulse waves of 23 volunteers. First, four korean medical doctors measured pulse waves of volunteers. And then, the pulse waves of volunteers were measured by HJ pulse analyser, HS pulse analyser. This was performed on the right Chon, Kwan and Chuk. Results : The traditional method and the HJ pulse analyser method had the 60.9% matches on the values of the pulse speed condition, the HS pulse analyser method had the 78.3% matches on the values of the pulse speed condition. The traditional method and the HJ pulse analyser method had the 56.5% (Chon), 65.2% (Kwan), 78.3% (Chuk) matches on the values of the pulse size condition, the HS pulse analyser method had the 65.2% (Chon), 13.0% (Kwan), 39.1% (Chuk) matches on the values of the pulse size condition. The traditional method and the HJ pulse analyser method had the 43.5% (Chon), 26.1% (Kwan), 47.8% (Chuk) matches on the values of the pulse depth condition, the HS pulse analyser method had the 45.5% (Chon), 30.4% (Kwan), 36.8% (Chuk) matches on the values of the pulse depth condition. Conclusions : According to these results, we suggest that the pulse analyser is necessary to develope for its high similarities with the traditional pulse diagnosis.

고령자의 맥상 특성에 대한 맥파분석적인 연구 (Study on the character of the old aged pulsation)

  • 김경철;이정원;류경호;강희정
    • 대한한의진단학회지
    • /
    • 제12권2호
    • /
    • pp.1-7
    • /
    • 2008
  • Objectives: The basis research of aged people's healthcare technology is very important, because our nation goes into an aged society rapidly. Especially in traditional medicine, pulse shapes of aged people were supposed to weak and empty pulse until now, but any objective measurement and compare research do not taken. Methods and Results: Therefore in this study we design observation study to find characteristic of pulse between younger group (age $20{\sim}30$) and elder group (age $43{\sim}80$) in Busan area. We used 3-dimensional pulse analyzer '3-D MAC' (Daeyomedi Co., Ltd.). And major parameters for comparison are 1) pulse height (h1), 2) applied pressure, 3) pulse power (energy), 4) high pressure duration (w) and 5) R-AI. Conclusions: According to analysis result, elder people's pulse has more large value in pulse height, applied pressure and pulse power than younger's that. It reveals that elder people in modernized lifestyle has Yang symptoms as well Yin symptoms. Consequently we need new method to care elder people's health, and this means more important direction than old text book. From now on verification research with objective diagnosis device like 3-D MAC, must be activated to build of evidence in traditional medicine. Cause traditional medicine's spirit of care and prevention is suitable to care elder people's cardiac and cerebral vascular disease those are have close relation with elder people.

  • PDF

적혈구 용적이 요골 동맥의 맥파에 미치는 영향 (Effect of Hematocrit Level on the Radial Pulse Wave)

  • 유현희;전영주;김재욱;이혜정;우영재;이유정;김종열
    • 동의생리병리학회지
    • /
    • 제23권5호
    • /
    • pp.1035-1040
    • /
    • 2009
  • In this work, we investigate the effect of blood hematocrit level on the radial pulse wave to study the clinical application of the pulse analyzer. For this purpose, we measured the radial pulse wave at the left Gwan for 15 males with abnormal high hematocrit level and 47 males with normal hematocrit level at the age of thirties and forties. Various variables of the radial pulse wave between two groups were analyzed by Student's T test. We found significant differences in several characteristic variables in the amplitude, time-span and the integrated area of the amplitude and time of the pulse wave. The systolic peak in the amplitude of the radial pulse wave was higher in abnormal high hematocrit group. In contrast, the third peak from the second incisure was higher and longer in normal hematocrit group. Our study suggests that the radial pulse wave can be useful in distinguishing the patient group with high hematocrit level and thus with high blood viscosity. Our finding may motivate research activities towards diverse clinical applications of the pulse wave.