• Title/Summary/Keyword: pulse analysis

Search Result 2,084, Processing Time 0.059 seconds

Analysis of Output Pulse of High Voltage and Nanosecond Blumlein Pulse Generator

  • Roh, Young-Su;Jin, Yun-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.150-155
    • /
    • 2013
  • A high voltage and nanosecond Blumlein pulse generator has been developed to produce an output pulse whose voltage level is greater than 250 kV and pulse duration 5 ns. The generator consists of various components such as a charging circuit, a pulse transformer, and a spark gap switch. As a heart of the generator, a Blumlein pulse forming line has been constructed in the cylindrical form using three cylindrical aluminum electrodes that are placed concentrically. Unlike the ideal Blumlein line, the output pulse of an actual Blumlein line may be affected by stray inductances and capacitances of switching and charging components, thereby degrading the performance of the generator. In this paper, PSPICE simulations have been performed to examine effects of stray inductances and capacitances on waveforms of output pulses. Simulation results show that the pulse waveform is significantly distorted mainly by the stray inductance of the spark gap switch.

Genomic analysis of Mycobacterium fortuitum by pulsed-field gel electrophoresis (Pulsed-field Gel Electrophoresis를 이용한 Mycobacterium fortuitum의 유전형 분석)

  • Lee, Tae-Yoon;Do, In-A;Kim, Sung-Kwang
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.366-385
    • /
    • 1995
  • Epidemiological studies are important in both the prevention and treatment of mycobacterial infections. This study was initiated to establish the pulsed-field gel electrophoresis (PFGE) method, which are not yet extensively studied. The most apprpriate restriction endonucleases included DraI, AsnI, and XbaI. The optimal PFGE condition was different according to the enzymes used. Two stage PFGE was performed, in case of DraI first stage was performed with 10 seconds of initial pulse and 15 seconds of final pulse, while the second stage was performed with 60 seconds of initial pulse and 70 seconds of final pulse. The electrophoresis time for DraI-PFGE was 14 hours for each stage. Electrophoresis was performed for 22 hours, in case of XbaI, with 3 seconds of initial pulse and 12 seconds of final pulse. Electrophoresis was performed for 22 hours, in case of AsnI, with 5 seconds of initial pulse and 25 seconds of final pulse. In all cases the voltage of the electrophoresis was maintained constantly at 200 voltage. Standard mycobacterial strains, which included Mycobacterium bovis BCG, M. tuberculosis, and M. fortuitum, could not be differentiated by PFGE analysis. PFGE analysis was performed to differentiate 9 clinically isolated M. fortuitum strains using AsnI. All M. fortuitum strains showed different genotypes except 2 strains. Cluster analysis divided M. fortuitum strains into 2 large groups. PFGE analysis was performed to further differentiate M. fortuitum isolates using XbaI. The undifferentiated 2 M. fortuitum strains showed different PFGE patterns with Xba I. Cluster analysis of the XbaI-PFGE patterns showed more complex grouping than AsnI-PFGE patterns, which showed that XbaI-PFGE analysis was better than AsnI-PFGE in M. fortuitum genotyping. The top dissimilarity values of AsnI-PFGE and XbaI-PFGE were 0.74 and 0.75, respectively. This value was higher than that of arbitrarily primed polymerase chain reaction (AP-PCR) analysis and lower than that of restriction fragment length polymorphism (RFLP) analysis. This suggested that PFGE can be used as a supportive or alternative genotyping method to RFLP analysis.

  • PDF

Parameter Estimation of The Distributed System via Improved Block Pulse Coefficients Estimation

  • Kim, Tai-hoon;Shim, Jae-sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.61.6-61
    • /
    • 2002
  • In these days, Block Pulse functions are used in a variety of fields such as the analysis and controller design of the systems. In applying the Block Pulse function technique to control and systems science, the integral operation of the Block Pulse series plays important roles. This is because differential equations are always involved in the representations of continuous-time models of dynamic systems, and differential operations are always approximated by the corresponding Block Pulse series through integration operational matrices. In order to apply the Block Pulse function technique to the problems of continuous-time dynamic systems more efficiently, it is necessary to find th...

  • PDF

Linear Pulse Motor Characteristics Analysis using Non-linear Simulation (비선형 시뮬레이션에 의한 리니어 펄스모터의 특성해석)

  • Lee, Je-Hie;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.584-587
    • /
    • 1992
  • Because linear motor directly drives linear motion, it does not need conversion equipment such as belt and gear. Especially linear pulse motor provide more precise positioning and large force of linear pulse motors. As current manufacture technic of linear pulse motor is much to be desired at home. This motor lay out to make use of computer aided design program, In this paper the experimental motor is 2-phases 4-poles hybrid pulse motor which has teeth per pole Simulation program is divided its function into 4 parts - air gap permeance analysis, permanent magnet & non-linear core operating point determine, winding configuration, leakage flux analysis. It is possible to make motor static and magnetic characteristics for this simulation program. Also, by varying input parameters of the program, experimental motor is to be compared to motor characteristics.

  • PDF

Two-Dimensional Analysis of Enthalpy Flow in a Pulse Tube (맥동관의 엔탈피유동에 대한 2차원 해석)

  • 백상호;장승철;정은수
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.1
    • /
    • pp.42-47
    • /
    • 1999
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass. momentum an energy equations of the gas as well as energy conservation of the tube wall. The mean temperature of the gas and the tube wall was obtained directly by assuming that the outer surface of a pules tibe wall is adiabatic. Axial profile of mean temperature is small. but it deviates significantly from linear profile when the dimensionless frequency is large. Effect of operating frequency. tube wall thickness, velocity ratio and velocity phase angle between both ends of a pulse tube on net enthalpy flow were shown.

  • PDF

On the Dynamic Response of Laminated Circular Cylindrical Shells under Dynamic Loads (동하중을 받는 복합재료 원통셸의 동적거동 해석)

  • 이영신;이기두
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.11
    • /
    • pp.2684-2693
    • /
    • 1993
  • The free vibration and dynamic response of cross-ply for CFRP and GFRP laminated circular cylindrical shells under dynamic loadings are investigated by using the first-order shear deformation shell theory. The modal analysis technique is used to develop the analytical solutions of simply supported cylindrical shells under dynamic load. The analysis is based on an expansion of the loads, displacements and rotations in a double Fourier series which satisfies the and boundary conditions of simply support. Analytical solution is assumed to be separable into a function of time and a function of position. In this paper, the considered load forces are step pulse, sine pulse, triangular(1, 2, 3) pulse and exponential pulse. The solution for a given loading pulse can be found by involving the convolution integral. The results show that the dynamic response are governed primarily by the natural period of the structure.

Study on the Basic Pulse Indicators for Pattern Identifications in Stroke (중풍환자의 변증에 사용되는 맥진 지표에 관한 연구)

  • Lee, Jung-Sup;Ko, Mi-Mi;Kang, Byoung-Kab;Kim, So-Yeon;Kim, Jeong-Cheol;Oh, Dal-Seok;Lee, In;Kim, Yun-Sik;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.964-968
    • /
    • 2009
  • The purpose of this study is to select the major pulse indicators and evaluate their significance in discriminating the subtypes of Pattern Identifications (PI) from stroke patients. Decision tree analysis was carried out using clinical data collected from 835 stroke patients with the same subtypes diagnosed identically by two experts with more than 3 year clinical experiences. Among the 10 pulse indicators, 6 major pulse indicators (slow, rapid, strong, weak, slippery, and fine pulse) were selected by decision tree analysis. The accumulated distributions of six pulse indicators in each PI showed that strong was major pulse indicator in Fire-Heat pattern, slippery in Dampness Phlegm pattern, weak in Qi Deficiency pattern. But there were two major combinations in Yin deficiency pattern, weak or fine with rapid pulse and weak or fine without rapid pulse. Therefore, it is suggested that 6 pulse indicators can be used for discrimination of PI in stroke patients, though the combination studies between these pulse indicators and the other PI indicators are left for further study.

The Study on the Web-Based Analysis System of Oriental Pulse Waveform (웹기반 임상 맥파 데이터 분석 시스템에 관한 연구)

  • Lee, Jun-Young
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.9-12
    • /
    • 2012
  • This paper analyzes a web-based clinical management system and conducts research on the pulse. Pulse analysis and the clinical study management system proposed by the web-based research holds significance in that it improves the objectivity and accuracy of pulse diagnosis. In particular, exact data must be analyzed through the clinical interpretation of these studies. Eventually oriental pulse standardization work will be continuously sustained. The findings of this study will help achieve remote diagnosis and consultation and updating of database. Research must be expanded to the development of telemedicine technology to create u-Health that will lead this present era.

Propagation characteristic analysis and measurement of gaussian pulse signals on the microstrip line (마이크로스트립 선로상 가우시안 펄스신호의 전파특성 해석 및 측정)

  • Rhee, Seoung-Yeop;Shin, Ho-Sub;Kim, Nam;Kwan, Weon-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1425-1432
    • /
    • 1998
  • The propagation properties of Gaussian pulse signals on the microstrip line are investigated by the Kirschning & Jansen's approximated equation to meet the frequency range of a pulse, accuracy, and geometrical requiremtns of the microstrip line. The dispersion of pulse signals is analyzed regarding to the relative permittivity .epsilon.$_{r}$, substrate height h and strip width w of the microstrip line. To verify theoretical results, several samples of 50.OMEGA. microstrip lines are fabricated. And the characteristics of pulse propagation along these lines are simple measured using VNA(Vector Network Analyzer) with time-domain analysis function. A fairly good agreement has been found between the measured pulse waveforms and computer simulations.

  • PDF