• 제목/요약/키워드: pseudo-ductile

검색결과 22건 처리시간 0.021초

유사동적 실험에 의한 철근콘크리트 교각의 주철근 겹이음에 따른 한정연성능력 (Limited Ductile Capacity of Reinforced Concrete Bridge Pier with Longitudinal Steel Lap-splicing by Pseudo Dynamic Test)

  • 박창규;박진영;조대연;이대형;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.885-890
    • /
    • 2002
  • Pseudo dynamic test is an on-line computer control method to achieve the realism of shaking table test with the economy and versatility of the conventional quasi-static approach. Pseudo dynamic tests of four full-size RC bridge piers have been carried out to investigate their seismic performance. For the purpose of precise evaluation, the experimental investigation was conducted to study the seismic performance of the real size specimen, which is constructed for highway bridge piers in Korean peninsula. Since it is believed that Korea belongs to the moderate seismicity region, three test specimens were designed in accordance with limited ductility design concept. Another one test specimen was nonseismically designed according to a conventional code. Important test parameters were transverse reinforcement and lap splicing. Lap splicing was frequently used in the plastic hinge region of many bridge columns. Furthermore, the seismic design code is not present about lap splice in Korean Roadway Bridge Design Code. The results show that specimens designed according to the limited ductility design concept exhibit higher seismic resistance. Specimens with longitudinal steel lap splice in the plastic hinge region appeared to significantly fail at low ductility level.

  • PDF

Pseudo-dynamic and cyclic loading tests on a steel-concrete vertical hybrid structure

  • Wang, Bo;Wu, Tao;Dai, Huijuan;Bai, Guoliang;Wu, Jian
    • Earthquakes and Structures
    • /
    • 제17권4호
    • /
    • pp.399-409
    • /
    • 2019
  • This paper presents the experimental investigations on the seismic performance of a peculiar steel-concrete vertical hybrid structural system referred to as steel truss-RC tubular column hybrid structure. It is typically applied as the supporting structural system to house air-cooled condensers in thermal power plants (TPPs). Firstly, pseudo-dynamic tests (PDTs) are performed on a scaled substructure to investigate the seismic performance of this hybrid structure under different hazard levels. The deformation performance, deterioration behavior and energy dissipation characteristics are analyzed. Then, a cyclic loading test is conducted after the final loading case of PDTs to verify the ultimate seismic resistant capacity of this hybrid structure. Finally, the failure mechanism is discussed through mechanical analysis based on the test results. The research results indicate that the steel truss-RC tubular column hybrid structure is an anti-seismic structural system with single-fortification line. RC tubular columns are the main energy dissipated components. The truss-to-column connections are the structural weak parts. In general, it has good ductile performance to satisfy the seismic design requirements in high-intensity earthquake regions.

Diverse Application of ECC Designed with Ground Granulated Blast Furnace Slag

  • Kim, Jeong-Su;Kim, Yun-Yong;Kim, Jin-Keun
    • International Journal of Concrete Structures and Materials
    • /
    • 제1권1호
    • /
    • pp.11-18
    • /
    • 2007
  • In the recent design of high ductile engineered cementitious composites (ECC), optimizing both processing and mechanical properties for specific applications is critical. This study employs a method to develop useful ECC produced with slag particles (slag-ECC) in the field, which possesses different fluid properties to facilitate diverse types of processing (i.e., self-consolidating or spray processing). Control of rheological modulation was regarded as a key factor to allow the performance of the desired processing while retaining the ductile material properties. To control the rheological properties of the composite, the basic slag-ECC composition was initially obtained, determined based on micromechanics and steady-state cracking theory. The stability and consequent viscosity of the suspensions were then mediated by optimizing the dosage of the chemical and mineral admixtures. The rheological properties altered through this approach were revealed to be effective in obtaining ECC-hardened properties, represented by pseudo strain-hardening behavior in uniaxial tension, allowing the readily achievement of the desired function of the fresh ECC.

Refined finite element modelling of circular CFST bridge piers subjected to the seismic load

  • Faxing Ding;Qingyuan Xu;Hao Sun;Fei Lyu
    • Computers and Concrete
    • /
    • 제33권6호
    • /
    • pp.643-658
    • /
    • 2024
  • To date, shell-solid and fibre element model analysis are the most commonly used methods to investigate the seismic performance of concrete-filled steel tube (CFST) bridge piers. However, most existing research does not consider the loss of bearing capacity caused by the fracture of the outer steel tube. To fill this knowledge gap, a refined finite element (FE) model considering the ductile damage of steel tubes and the behaviour of infilled concrete with cracks is established and verified against experimental results of unidirectional, bidirectional cyclic loading tests and pseudo-dynamic loading tests. In addition, a parametric study is conducted to investigate the seismic performance of CFST bridge piers with different concrete strength, steel strength, axial compression ratio, slenderness ratio and infilled concrete height using the proposed model. The validation shows that the proposed refined FE model can effectively simulate the residual displacement of CFST bridge piers subjected to highintensity earthquakes. The parametric analysis indicates that CFST piers hold sufficient strength reserves and sound deformation capacity and, thus, possess excellent application prospects for bridge construction in high-intensity areas.

콘크리트 충전 강교각의 내진 성능 (The Seismic Performance for Concrete-filled Steel Piers)

  • 정지만;장승필;인성빈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.189-196
    • /
    • 2002
  • The capacity of CFS piers has not been used to a practical design, because there is no guide of a seismic design for CFS piers. Therefore, the guide of a seismic design value is derived from tests of CFS piers in order to apply it to a practical seismic design. Steel piers and concrete-filled steel piers are tested with constant axial load using quasi-static cyclic lateral load to check ductile capacity and using the real Kobe ground motion of pseudo-dynamic test to verify seismic performance. The results prove that CFS piers have more satisfactory ductility and strength than steel piers and relatively large hysteretic damping in dynamic behaviors. The seismic performance of steel and CFS piers is quantified on the basis of the test results. These results are evaluated through comparison of both the response modification factor method by elastic response spectrum and the performance-based design method by capacity spectrum and demand spectrum using effective viscous damping. The response modification factor of CFS piers is presented to apply in seismic design on a basis of this evaluation for a seismic performance.

  • PDF

내진보강용 폴리우레아로 보강된 철근콘크리트 기둥의 내진성능 평가에 대한 유사동적실험 연구 (Pseudo Dynamic Test Study on Seismic Performance Evaluation of RC Columns Retrofitted by PolyUrea)

  • 조철민;이두성;김태균;김장호
    • 대한토목학회논문집
    • /
    • 제37권2호
    • /
    • pp.289-301
    • /
    • 2017
  • 국내외적으로 지진의 발생이 빈번함에 따라 인명 및 재산 피해가 발생하고 추가적인 경제적 손실을 초래한다. 국내의 비내진으로 설계된 구조물의 보수 보강이 시급할 뿐만 아니라 지진에 대한 관심이 고조됨에 따라 내진보강에 대한 연구가 활발히 진행되고 있다. 최근 고연성 보강재를 사용한 내진보강기법이 소개되면서 강성보강보다는 연성보강에 대한 신뢰도가 높아지고 있다. 따라서 본 연구에서는 연성보강 재료로써 최근 각광받고 있는 폴리우레아를 이용한 내진보강공법을 소개하기 위해서, 폴리우레아로 보강한 RC 시편에 대하여 일축압축시험과 유사동적실험을 수행하였다. 일축압축시험에서 폴리우레아 보강시 강도가 증진되었을 뿐 아니라 연성거동을 확인할 수 있었으며, 실제 지진파를 적용한 유사동적실험에서는 상대변위, 주철근의 변형률, 변위연성도, 소산에너지 모두 향상된 보강성능을 확인할 수 있었다. 연성보강의 목적으로 개발한 폴리우레아 보강방법은 기둥부재의 내진보강에 유용하게 사용될 것이라고 판단된다.

진동대 실험을 통한 원형 합성 기둥의 내진 성능 평가 (Seismic performance evaluation of circular composite columns by shaking table test)

  • 심창수;정영수;박지호;박창영
    • 한국지진공학회논문집
    • /
    • 제11권5호
    • /
    • pp.71-81
    • /
    • 2007
  • 합성 교각의 설계에서 요구 내진성능을 만족하기 위한 철근상세 규정이 명확하지 않은 측면이 있다. 합성 교각은 단면치수를 감소시키고 지진하중하에서 기둥의 연성을 개선하기 위해 제안되었다. 이 논문에서는 400mm 직경을 가진 단일 강재를 콘크리트에 매입한 합성기둥 부재를 5기 제작하여 합성기둥의 내진성능을 연구하였다. 진동대 실험과 유사동적 실험이 수행되었는데 근단층지반운동을 고려한 축소모형의 구조적 거동이 평가되었다. 실험 변수는 횡철근의 간격, 주철근의 겹침이음, 매입 강재 단면으로 설정하였다. 진동대 실험에 의해 평가된 변위연성도가 유사동적 실험에 비해 적게 나타났고 한정연성설계, 주철근의 겹침 이음 50%를 가진 부재가 기준 부재에 비해서 낮은 연성도를 보였다. 강재비는 극한강도에 영향을 미치고 겹침이음과 횡철근 비의 감소는 변위능력을 감소시켰다. 합성 교각의 상세에 따른 에너지 소산능력의 차이는 뚜렷하게 나타나지 않았다.

콘크리트 충전 강교각의 내진 성능 평가 (The Evaluation of Seismic Performance for Concrete-filled Steel Piers)

  • 정지만;장승필;인성빈
    • 한국지진공학회논문집
    • /
    • 제6권5호
    • /
    • pp.53-58
    • /
    • 2002
  • 최근, 콘크리트 충전 강교각은 신속한 시공과 뛰어난 연성능력으로 인해 도심지에서 철근 콘크리트 교각의 대안이 되고 있다. 이러한 콘크리트 충전 강교각은 내진 설계에서도 훌륭한 성능을 발휘할 수 있으나 내진 설계의 가이드가 없어 내진 설계시 그 성능을 모두 반영하지 못하고 있는 상황이다. 이에 실제 적용을 위해 콘크리트 충전 강교각 실험으로부터 얻어진 실험치로부터 내진 설계에 지침이 될 수 있는 가이드를 제시하고자 한다. 콘크리트 충전 강교각과 일반 강교각의 연성 능력을 평가하기 위해 준 정적 반복 재하 실험을 수행하고, 지진 거동을 검증하기 위해 고베 지진을 입력 데이타로 한 유사 동적 실험을 수행한다. 콘크리트 충전 강교각은 일반 강교각에 비해 만족할 만한 연성도와 강도를 보이고, 동적 거동은 상대적으로 큰 이력감쇠를 증명한다. 실험으로 얻어진 데이터를 근거로 하여 콘크리트 충전 강교각의 내진 성능을 정량화 하고, 탄성응답 스펙트럼에 의한 지진응답 수정계수법과 유효 점성 감쇠를 이용한 성능 곡선 및 요구 스펙트럼에 의한 성능기초 설계법의 비교를 통하여, 콘크리트 충전 강교각과 일반 강교각의 내진 성능을 평가한다. 이러한 내진 성능 평가를 기초로 하여, 일반 강교각과 더불어 내진 설계에 적용할 수 있는 콘크리트 충전 강교각의 지진응답 수정계수를 제시한다.

MoSi2 복합재료의 굽힘강도 특성 (Flexural strength properties of MoSi2 based composites)

  • 이상필;이현욱;이진경;배동수
    • 한국해양공학회지
    • /
    • 제25권4호
    • /
    • pp.66-71
    • /
    • 2011
  • The flexural strength of $MoSi_2$ based composites reinforced with Nb sheets has been investigated, based on the detailed examination of their microstructure and fractured surface. Both sintered density and porosity of Nb/$MoSi_2$ composites were also examined. Nb/$MoSi_2$ composites were fabricated by different conditions such as temperature, applied pressure and its holding time, using a hot-press device. The volume fraction of Nb sheet in this composite system was fixed as 10%. The characterization of Nb/$MoSi_2$ composites were investigated by means of optical microscopy, scanning electron microscope and three point bending test. Nb/$MoSi_2$ composites represented a dense morphology at the interfacial region, accompanying the creation of two types of reaction layer by the chemical reaction of Nb and $MoSi_2$. Nb/$MoSi_2$ composites possessed an excellent density at the fabricating temperature of $1350^{\circ}C$, corresponded to about 95% of theoretical density. The flexural strength of Nb/$MoSi_2$ romposites were greatly affected by the pressure holding time at the same fabricating temperature, owing to the large suppression of porosity in the microstructure. Especially, Nb/$MoSi_2$ composites represented a good flexural strength of about 310 MPa at the fabricating condition of $1350^{\circ}C$, 30MPa and 60min, accompanying the pseudo-ductile fracture behavior by the deformation of Nb sheet and the interfacial delamination.

철근콘크리트 부재 보강용 유사연성 FRP 하이브리드 시트의 부착 특성 (Bond Capacity of Pseudo-Ductile FRP Hybrid Sheet to Strengthen RC Members)

  • 윤혜선;이정미;이진용;최동욱;김길희
    • 콘크리트학회논문집
    • /
    • 제21권1호
    • /
    • pp.47-53
    • /
    • 2009
  • 탄소 섬유와 유리 섬유를 체적 비율 1 : 8.8로 조합하여 강성이 높은 탄소 섬유가 인장에 저항한 후 먼저 파단되고 그 후 유리 섬유가 인장에 저항하여 높은 연성을 발휘하도록 한 하이브리드 시트를 제작하고 시트 길이를 100, 200, 400 mm로 각각 다르게 하여 시트 길이에 따른 콘크리트와 하이브리드 시트 계면에서의 부착 특성에 대해 고찰하였다. 실험 결과, 시트의 유효 부착 길이는 100$\sim$200 mm 사이에서 존재하고, 시트의 콘크리트 계면에서의 효율적인 부착강도를 발휘하기 위해서는 150 mm 이상의 부착 길이가 확보되어야 하며, 콘크리트와 하이브리드 시트 계면에서의 부착강도는 대략 3.0 MPa이고 슬립량은 0.175 mm로 나타나는 것을 알 수 있었다.