Abstract

As earthquakes have frequently happened all over the world, huge losses of human life and property have occurred. Therefore, retrofitting and strengthen technologies of non-seismically designed structures in Korea are urgent. Also, there has been a growing interest about seismic retrofitting, where researches on the topic have been actively pursued in Korea. The study results showed that ductility inducing retrofitting method is more superior stiffness inducing method. In Japan, Super Reinforcement with Flexibility (SRF) was introduced. Therefore, in this study, seismic performance evaluation was performed through pseudo dynamic test and uniaxial compression test for RC column retrofitted by PolyUrea for ductility inducing retrofitting material. Uniaxial compression test results showed that strength of all specimens retrofitted by PolyUrea was higher than that of RC specimens. Also, all specimens retrofitted by PolyUrea also showed ductile fracture behavior. In pseudo dynamic test, by appling real earthquake record, the seismic behavior of RC column reinforced by PolyUrea was evaluated through relative displacement, reinforcement strain, displacement ductility, and dissipation energy. The results showed that PolyUrea helped to enhance seismic performance of RC columns.

국내외적으로 지진의 발생이 빈번함에 따라 인명 및 재산 피해가 발생하고 추가적인 경제적 손실을 초래한다. 국내의 비내진으로 설계된 구조물의 보수 보강이 시급할 뿐만 아니라 지진에 대한 관심이 고조됨에 따라 내진보강에 대한 연구가 활발히 진행되고 있다. 최근 고연성 보강재를 사용한 내진보강기법이 소개되면서 강성보강보다는 연성보강에 대한 신뢰도가 높아지고 있다. 따라서 본 연구에서는 연성보강 재료로써 최근 각광받고 있는 폴리우레아를 이용한 내진보강공법을 소개하기 위해서, 폴리우레아로 보강한 RC 시편에 대하여 일축압축시험과 유사동적실험을 수행하였다. 일축압축시험에서 폴리우레아 보강시 강도가 증진되었을 뿐 아니라 연성거동을 확인할 수 있었으며, 실제 지진파를 적용한 유사동적실험에서는 상대변위, 주철근의 변형률, 변위연성도, 소산에너지 모두 향상된 보강성능을 확인할 수 있었다. 연성보강의 목적으로 개발한 폴리우레아 보강방법은 기둥부재의 내진보강에 유용하게 사용될 것이라고 판단된다.

Keywords

References

  1. Ang, B. G., Priestley, M. J. N. and Paulay, T. (1994). "Seismic shear strength of circular reinforced concrete columns." ACI Structual Journal, Vol. 86, No. 1, pp. 45-59.
  2. Bonacci, J. F. and Maalej, M. (2001). "Behavioral trends of RC beams strengthened with externally bonded FRP." Journal of Composites for Construction, Vol. 5, No. 2, pp. 102-113. https://doi.org/10.1061/(ASCE)1090-0268(2001)5:2(102)
  3. Chen, C. H., Lai, W. C., Cordova, P., Deierlein, G. G. and Tsai, K. C. (2003). "Pseudo-dynamic test of full-scale RCS frame: Part 1-Design, construction and testing." In Proceedings of International Workshop on Steel and Concrete Composite Constructions, pp. 107-118.
  4. Chung, Y. S., Park, J. H., Park, H. S. and Cho, C. B. (2002). "Pseudo dynamic test for the seismic performance enhancement of circular RC bridge piers retrofitted with fibers." Journal of the Korea concrete institute, Vol. 14, No. 2, pp. 180-189 (in Korea). https://doi.org/10.4334/JKCI.2002.14.2.180
  5. Hakuno, M., Shidawara, M. and Hara, T. (1969). "Dynamic destructive test of a cantilever beam, controlled by and analog-computer." Transactions of The Japan Society of Civil Engineers, Vol. 171, pp. 1-9.
  6. Jin, D. H. (2016). Seismic Performance Evaluation of Concrete Structure using Hybrid Test System, Master degree thesis, Myungji University, Korea (in Korea).
  7. Jung, R. Y. and Benson Shing, P. (2006). "Performance evaluation of a real-time pseudo-dynamic test system." Earthquake Engineering and Structural Dynamics, Vol. 35, No. 7, pp. 789-810. https://doi.org/10.1002/eqe.547
  8. Kim, D. K., Kim, D. Y., Ahn, J. H. and Park, C. L. (1997). "Assessment of the seismic capacity of structure using pseudo-dynamic test", Journal of the earthquake engineering society of Korea, Vol. 1, No. 2, pp. 49-57 (in Korea).
  9. KMA, Korea Meteorological Administration, Earthquake (2016). Available at: http://www.kma.go.kr/mini/earthquake/main.jsp (in Korea).
  10. Lee, S. K., Chen, Z. F., Ng, M., Tang, J. M., Wan, L. L., Liu, M. and Lee, L. (2008). "Evaluation of CFRP, GFRP and BFRP material systems for the strengthening of RC slabs." Journal of Reinforced Plastics and Composites, pp. 1-12
  11. Lee, D. H., Oh, J. K., Yu, W. D. and Choi, E. S. (2012). "Seismic performance of RC columns confined by outside lateral reinforcement", Journal of the Korean Society of Civil Engineers, Vol. 32, No. 3, pp. 189-196 (in Korea).
  12. Li, Y. F., Chang, S. Y., Tzeng, W. C. and Huang, K. (2003). "The pseudo dynamic test of RC bridge columns analyzed through the Hilbert-Huang transform." Journal of Mechanics, Vol. 19, No. 3, pp. 373-387. https://doi.org/10.1017/S1727719100003221
  13. Marriott, D., Pampanin, S. and Palermo, A. (2009). "Quasi-static and pseudo-dynamic testing of unbonded post-tensioned rocking bridge piers with external replaceable dissipaters." Earthquake Engineering and Structural Dynamics, Vol. 38, No.3, pp. 331-354. https://doi.org/10.1002/eqe.857
  14. Shing, P. S. B. and Vannan, M. T. (1991). "Implicit time integration for pseudodynamic tests: Convergence and energy dissipation." Earthquake Engineering and Structural Dynamics, Vol. 20, No. 9, pp. 809-819. https://doi.org/10.1002/eqe.4290200902
  15. Takanashi, K., Udagawa, K., Seki, M., Okada, T. and Tanaka, H. (1975). "Nonlinear earthquake response analysis of structures by a computer-actuator on-line system." Bulletin of Earthquake Resistant Structure Research Center, Vol. 8, pp. 1-17.
  16. Yang, Y. S., Wang, K. J., Wang, S. J., Hsu, C. W., Tsai, K. C. and Hsieh, S. H. (2004). "Networked pseudo-dynamic testing part I: Database approach." In Proceedings of the 13th World Conference on Earthquake Engineering, Vancouver, BC, Canada, pp. 1910-1919.
  17. Youm, K. S., Kwon, T. G., Lee, Y. H. and Hwang, Y. K. (2006). "Seismic retrofit of GFRP wrapping on the lap-spliced bridge piers." Journal of the Korean Society of Civil Engineers, Vol. 26, No. 2, pp. 311-318 (in Korea).