• Title/Summary/Keyword: proton beam

Search Result 266, Processing Time 0.026 seconds

KOMAC RFQ Vacuum System

  • Han, J.M.d;S.H.Jeong;Cho, Y.S.;Park, B.H.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.33-33
    • /
    • 1999
  • The design of a vacuum pumping system for the KOMAC (Korea Multipurpose Accelerator Complex) RFQ(Radio-Frequency Quadrupole) linac is described. [Fig] Resulted from the lost proton beam, gas streaming from the LEBT (Low Energy Beam Transport) and out-gassing from the surfaces of the RFQ cavity and vacuum plumbing, the total gas load will be on the order of 7.2$\times$10-4 Torr-liters/sec, consisting mainly of hydrogen. The system designed to pump on a continual basis with redundancy to ensure that the minimal operating vacuum level of 1.0$\times$10-6 Torr is maintained even under abnormal conditions. Details of the design, performance analysis and the preliminary test results of the cryogenic pumps are presented.

  • PDF

Study of Uniform Beam Formation at ISOL Target Using TRANSPORT

  • Hong, Seong-Gwang;Kim, Jae-Hong;Kim, Jong-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.174.2-174.2
    • /
    • 2013
  • 사이클로트론에서 가속된 70 MeV 양성자 빔은 stripper에서 인출된 후 ISOL 표적에 조사하게 된다. 이 때 희귀동위원소를 생산하기 위한 ISOL 표적의 온도는 평균 $2,000^{\circ}C$ 5%로 유지하여야 한다. 사용하고자 하는 원판형태의 우라늄 표적은 직경이 45 mm 이므로 50 mm 이상의 균일한 양성자 빔이 필요하다. 본 연구에서는 stripper에서부터 ISOL 표적 까지 빔전송에 필요한 최적 조건을 연구하였다. 총 길이는 15 m 이며 두 개의 dipole을 사용하여 빔을 90도 전환시키며 3개의 4중극전자석을 사용하였다. ISOL 표적에 균일한 빔을 조사하기 위해 wobbling 방법을 활용하여 직경 50 mm 의 균일빔을 발생하고자 한다. 빔 전송 프로그램 TRANSPORT을 이용하여 stripper에서 wobbler 전까지의 빔 광학을 계산한 결과를 보고자 하고 TRANSPORT의 결과를 TURTLE 프로그램에 적용시켜 ISOL 표적에서의 균일도를 5% 미만으로 유지하는 최적조건을 발표한다.

  • PDF

A Synthesis of Iron Oxide Based and Gadolinium Oxide Based Radiosensitizer for the Therapeutic Enhancement of Proton Beam Cancer (양성자 빔 암치료효과 개선을 위한 산화철 및 산화가돌리늄 나노입자 기반의 방사선증감제 합성)

  • Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.325-332
    • /
    • 2014
  • Metallic nanoparticles have attractive properties in biomedical applications such as diagnostics and therapeutics. Cross linked dextran coated iron oxide nanoparticles (SPIONs) and silica coated gadolinium oxide nanoparticles (SPGONs) have been synthesized as a radiosensitizer in the proton beam cancer therapy. The dextran and silicaused for the protective moieties on the SPIONs and SPGONs respectively. Size distributions of synthesized nanoparticles were confirmed 3~5 nm for SPIONs and 30~100 nm for SPGONs by transmission electron microscope (TEM). Cell survival fraction measurement and Western blot assay were performed to evaluate the radiosensitization effects of synthesized radiosensitizer. The calculated radiosensitization of SPIONs and SPGONs at 90 % cell death from the measured cell survival curves were 1.23 and 1.03 respectively. Western blotting results also show the same consistent results that the amount of released cytochrome c from mitochondria was considerably increased for the cancer cells taken up SPIONs.

A Study on the absorbed dose to water for high energy electron beams using Water equivalency of plastic phantom (고 에너지 전자선에서 물등가 고체팬톰을 이용한 물 흡수선량 측정에 관한 연구)

  • Sin, Dong-Ho;Sin, Dong-Oh;Kim, Sung-Hoon;Park, Sung-Yong;Ji, Young-Hoon;Ahn, Hee-Kyung;Kang, Jin-Oh;Hong, Seong-Eon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.166-169
    • /
    • 2004
  • In the International Code of Practice for dosimetry TRS-398 published by International Atomic Energy Agency(IAEA), water equivalency plastic phantom may be used under certain circumstances for electron beam dosimetry for beam quality E0${\leq}$ 10 MeV. In this study, Palstic Water$^{TM}$ and Virtual Water$^{TM}$ were evaluated in order to determine fluence scaling factor hpl. Plastic phantom was evaluated for five electron energy from 6 MeV to 20 MeV. From the measured data of Palstic Water$^{TM}$, the fluence scaling factor hpl was found to be average 0.9964 and Virtual Water$^{TM}$ fluence scaling factor was 1.0156.

  • PDF

The Development of a beam profile monitoring system for improving the beam output characteristics (빔 출력 특성 개선을 위한 빔 프로파일 모니터링 시스템 개발)

  • An, Young-jun;Hur, Min-goo;Yang, Seung-dae;Shin, Dae-seob;Lee, Dong-hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2689-2696
    • /
    • 2015
  • Radioactive isotopes which are manufactured using a cyclotron in a radioisotope used for radiation diagnosis is affected by the production yield according to size and shape of the beam and beam uniform degree from irradiated location when the proton beam investigated the target by cyclotron. Therefore, in this paper developed the BPM(Beam Profile Monitor) device capable of measuring the beam cross-section at the cyclotron beam line. It was configured so as to be able to remote control the BPM device in LabView and used the BPM program it was to be able to easily monitor and display to analyze the graph of two-dimensional graph and a three-dimensional beam distribution numerical information of the beam obtained while scanning the tungsten wire to the X and Y axis. The time it takes to measure the beam can be confirmed 37seconds when step motor driving speed was 2000pps. Through a beam readjusted based on the measured beam distribution information by optimizing the beam distribution it can be made to maximize the RI production yield and contribute supply stabilization.

Ion-Beam Induced Changes in the Characteristics of Gd Doped Ceria (이온빔 조사에 따른 Gd-doped Ceria의 특성 변화)

  • Kim, Tae-Hyung;Ryu, Boo-Hyung;Lee, In-Ja
    • Applied Chemistry for Engineering
    • /
    • v.21 no.4
    • /
    • pp.401-404
    • /
    • 2010
  • The ion-beam induced changes in the characteristics of gadolinium doped ceria (GDC) pellets have been studied by UV-visible spectroscopy (UV-vis), SEM, and XRD. Implanted ions were protons or Xe ions with the energy of 120 keV or 5 MeV. Densely sintered pristine GDC pellets have cubic fluorite structure and are brown in color. As the ion irradiation proceeded, its color gradually turned into light black and finally into dark black. XRD patterns of GDC pellets were closely related with ion energy and the penetration depth of X-ray. It showed that upon the ion irradiation (120 keV) the lattice parameter of the cubic fluorite phase just beneath the surface is increased.

Simulation of Diocotron Instability of a Hollow Electron Beam Used for the Collimation of Proton Beam

  • Jeong, Seung-Il;Lee, Yeong-Ho;Jeong, Mo-Se;Lee, Ho-Jun;Lee, Hae-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.494-494
    • /
    • 2012
  • 최근에 현대 물리학과 과학의 정점에 있는 초전도가속기 같은 고에너지 빔 가속기 시스템에서 Diocotron instability의 연구가 재조명 되고 있다. 환형의 전자 빔 사이로 프로톤 빔을 통과시키는 구조로써 자기장과 회전하는 전자빔의 상호작용에 기초를 두고 있으며 이 환형의 전자 빔이 고에너지의 프로톤 빔을 집속하는 역할을 한다. 하지만 전자빔이 진행함과 동시에 왜곡되는 현상이 발생하는데 이 왜곡되는 현상을 충분히 조절하지 못한다면 프로톤 빔의 손실과 가속하는 빔의 에너지 저하를 초래하게 될 것이고 또한 실험장치 자체에도 큰 결함을 발생 시킬 수 있다. 따라서 Diocotron instability는 가속기를 활성화 하는데 주요한 테마가 될 것이다. 환형의 전자 빔 층은 정전기적 효과로 인해서 안쪽과 바깥쪽의 속도차가 발생하게 되고 이로 인하여 drift instability 가 발생하게 되어서 왜곡이 발생하고 결국에는 몇 개의 소용돌이를 생성하게 된다. 본 연구에서는 이를 2차원 원통형 구조의 Particle-in-cell 시뮬레이션을 통하여 연구하였으며 자기장의 효과에 따른 환형의 전자빔의 왜곡현상을 지연시키는 방안에 중점을 두었다. 특히 자기장의 세기, 전자빔의 밀도, 전자빔 층의 두께, 전자빔의 프로필의 차이에 의한 결과로 연구하였다.

  • PDF

DESIGN AND FABRICATION OF THE BEAM POSITION MONITOR FOR THE PEFP LINAC

  • Kwon, Hyeok-Jung;Kim, Han-Sung;Seol, Kyung-Tae;Ryu, Jin-Yeong;Jang, Ji-Ho;Cho, Yong-Sub
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.523-528
    • /
    • 2013
  • The beam position monitor (BPM) is an essential component for the PEFP 100-MeV linac's commissioning. A prototype stripline-type linac BPM was designedfor this purpose. The electrode aperture is 20 mm in diameter, and the electrode is 25 mm long, so it can be installed between Drift Tube Linac (DTL)101 and DTL102, which is the shortest distance. One end of the electrode is connected to the Sub Miniature Type A (SMA) feed through for signal measurement, and the other end is terminated as a short. The signal amplitude of the fundamental component was calculated and compared with that of the second harmonic component. The designed BPM was fabricated and a low-power RF test was conducted. In this paper, the design, fabrication and low power test of the BPM for the PEFP linac are presented.