• Title/Summary/Keyword: protection technique.

Search Result 902, Processing Time 0.031 seconds

An Application Obfuscation Method Using Security Token for Encryption in Android (안드로이드 환경에서 보안 토큰을 이용한 앱 난독화 기법)

  • Shin, JinSeop;Ahn, Jaehwan
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.6
    • /
    • pp.1457-1465
    • /
    • 2017
  • With the growing of smart devices market, malicious behavior has gradually expanded its scope. Accordingly, many studies have been conducted to analyze malicious apps and automated analysis tools have been released. However these tools cause the side effects that the application protection tools such as ProGuard, DexGuard become vulnerable to analyzers or attackers. This paper suggests the protection mechanism to apply to the Android apps using security token, rather than general-purpose protection solutions that can be applied in malicious apps. The main features of this technique are that Android app is not properly loaded in the memory when the security token is abnormal or is not inserted and protected parts using the technique are not exposed.

Watermarking Technique for the Digital Contents Protection (영상 콘텐츠 지적재산권 보호 워터마킹 기술)

  • 송학현;김윤호;류광렬
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.144-148
    • /
    • 2004
  • Beyond the digital world from the analog age, the contents are very easily copied under the illegal conditions and these are rapidly distributed by the information super highway. The increase of illegal usage and conflict in digital content market would diminish motivation of creators for their work, furthermore break down digital content market on cyberspace. Watermarking technology support to the legal users by the protection technique based on the digital content copyright protection method(DRM). Most of previous digital watermarking have embeded to the content. In this paper, we researched the standardization of digital rights management and developed more efficient watermark embedding method.

  • PDF

A Study on Confidential Data Hiding Technique with Spatial Encryption for Color Image

  • Jung, Soo-Mok
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.1
    • /
    • pp.85-88
    • /
    • 2019
  • In this paper, we propose a technique for spatially encrypting confidential data into R, G, B planes of color image and extracting spatially encrypted confidential data. The effectiveness of the proposed technique is verified by mathematically analyzing the quality of the stego-image generated using the proposed technique. The proposed technique can hide confidential data securely into cover image by spatially encrypting the confidential data, and can extract confidential data from the stego-image. The quality of the stego-image created by applying the proposed technique is very good. The average value of the quality of the stego-image is 51.14 dB. Therefore, it is not visually recognizable whether the confidential data is hidden in the stego-image. The proposed technique can be widely used for military and intellectual property protection.

Static Switch Controller Based on Artificial Neural Network in Micro-Grid Systems

  • Saeedimoghadam, Mojtaba;Moazzami, Majid;Nabavi, Seyed. M.H.;Dehghani, Majid
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1822-1831
    • /
    • 2014
  • Micro-grid is connected to the main power grid through a static switch. One of the critical issues in micro-grids is protection which must disconnect the micro-grid from the network in short-circuit contingencies. Protective methods of micro-grid mainly follow the model of distribution system protection. This protection scheme suffers from improper operation due to the presence of single-phase loads, imbalance of three-phase loads and occurrence of power swings in micro-grid. In this paper, a new method which prevents from improper performance of static micro-grid protection is proposed. This method works based on artificial neural network (ANN) and able to differentiate short circuit from power swings by measuring impedance and the rate of impedance variations in PCC bus. This new technique provides a protective system with higher reliability.

Routing and Wavelength Assignment in Survivable WDM Networks without Wavelength Conversion

  • Lee, Tae-Han;Park, Sung-Soo;Lee, Kyung-Sik
    • Management Science and Financial Engineering
    • /
    • v.11 no.2
    • /
    • pp.85-103
    • /
    • 2005
  • In this paper, we consider the routing and wavelength assignment problem in survivable WDM transport network without wavelength conversion. We assume the single-link failure and a path protection scheme in optical layer. When a physical network and a set of working paths are given, the problem is to select a link-disjoint protection path for each working path and assign a wavelength for each working and protection path. We give an integer programming formulation of the problem and propose an algorithm to solve it. Though the formulation has exponentially many variables, we solve the linear programming relaxation of it by using column generation technique. We devise a branch-and price algorithm to solve the column generation problem. After solving the linear programming relaxation, we apply a variable fixing procedure combined with the column generation to get an integral solution. We test the proposed algorithm on some randomly generated data and test results show that the algorithm gives very good solutions.

Numerical Algorithm for Distance Protection and Arcing Fault Recognitior (고장거리계산과 아크고장 판별 알고리즘)

  • Radojevic, Zoran;Park, K.W.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.163-165
    • /
    • 2002
  • In this paper a new numerical algorithm for fault distance calculation and arcing fault recognition based on one terminal data and derived in lime domain is presented. The algorithm is derived for the case of most frequent single-phase line to ground fault. The faulted phase voltage at the fault place is modeled as a serial connection of fault resistance and arc voltage. The fault distance and arc voltage amplitude are estimated using Least Error Squares Technique. The algorithm can be applied for distance protection, intelligent autoreclosure and for fault location. The results of algorithm tested through computer simulation are given.

  • PDF

The Effects of cathodic protection on fracture toughness of buried gas pipeline (매설가스배관의 음극방식이 배관의 파괴인성에 미치는 영향)

  • Kim, Cheol-Man;Kim, Woo-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.573-578
    • /
    • 2001
  • For the corrosion protect ion of the natural gas transmission pipelines, two methods are used, cathodic protection and coating technique. In the case of cathodic protection, defects are embrittled by occurring hydrogen at the crack tip or material surface. It is however very important to evaluate whether cracks in the embrittled area can grow or not, especially in weld metal. In this work, on the basis of elastic plastic fracture mechanics, we performed CTOD test ing with varying test conditions, such as the potential and current density. The CTOD of the base steel and weld metal showed a strong dependence of the test conditions. The CTOD decreased with increasing cathodic potential and current density. The morphology of the fracture surface showed quasi-cleavage. Hydrogen introduced fractures, caused by cathodic overprotection.

  • PDF

Joint Source Channel Coding for H-263+ Based Video by Using the Unequal Error Protection Technique (H.263+ 기반 영상 소스 채널 결합 부호화기의 불균등 오류 보호(UEP) 기법 연구)

  • 이상훈;최윤식
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.45-48
    • /
    • 2001
  • Unequal Error Protection(UP) is reasonable scheme in transmission of compressed video with low bit rate. Because it offers the error correction ability each other data according to the Source Significance Information. Hence it can also be flexible to the given channel environment on the video transmission. This paper propose the joint source channel coding through the UEP in consideration of the hierarchical structure of H.263+ based video and the influence of the transmission error. It especially proposes the error-resilient video transmission technique which can reduce complexity of channel coder & decoder by partitioning the video data with a frame. As the result of the proposed algorithm, it is possible to increase the quality of reconstructed video in the error environment without creating additional bits.

  • PDF

A Study on the Fuse Sizing Technique for the Protection of Satellite Power System (인공위성 전력 시스템 보호를 위한 퓨즈 선정 기법 연구)

  • Jeon, Hyeon-Jin;Lim, Seong-Bin;Lee, Sang-Rok
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Power system in satellite is protected by installing fuses, LCLs (Latching Current Limiters), etc. between satellite power supply and loads. In this paper, the fuse sizing technique for satellite power system protection is addressed. Detailed fuse sizing method is explained and it is shown that the single fuse connection method is mathematically subordinated to the parallel fuse connection method. In addition, appropriate fuse selection method is newly suggested under a situation where exact current characteristics of a load connected to a fuse is unknown.

A Study on the Design, Fabrication and Characteristics Test of 25KJ Superconducting Magnetic Energy Storage (25KJ 초전도 에너지 저장장치의 설계,제작 및 특성 시험)

  • 홍원표;원종수;이송엽;이승원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.10
    • /
    • pp.683-693
    • /
    • 1988
  • For the economical and reasonable operation of electric power system according to continual increase of electric power demand and decrease of load factor, the potential application of superconducting magnertic energy storage [SMES] with high efficiency and fast response in the electric utility is receiving attractive attension. In the light of this background, to confirm the basic principle of SMES, theoretical study, design technique and fabrication procedure for superconducting coil, current lead, cryostat, measuring and protection system of SMES are described in detail. Especially, a new design technique for superconducting coil and current lead is porposed and it was proved experimentally by the performance test of SMES which is developed for the first time in our country. At the peak operating current 200A, the maximum magnetic field amd stored energy of the coil are 3.52T and 2500J, espectively. The thermal and mechanical stability of 2500J SMES is also confirmed experimetally by its characteristics test, AC loss, protection system, charge and discharge test. The experimetal results show good characteristics of energy storage system.

  • PDF