• Title/Summary/Keyword: protection risks

Search Result 298, Processing Time 0.023 seconds

Experimental Study on the Changes in the Oxygen Concentration and the Pressure at Temperature of 200 ℃ for the Assessment of the Risks of Fire and Explosion of Propylene (프로필렌의 화재 및 폭발 위험성 평가를 위한 온도 200 ℃에서 산소농도와 압력의 변화에 따른 실험적 연구)

  • Choi, Yu-Jung;Choi, Jae-Wook
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.356-361
    • /
    • 2020
  • Propylene is widely used in petrochemical manufacturing at over 200 ℃. However, since propylene is a flammable gas with fire and explosion risks, inert nitrogen is injected to prevent them. In this study, experiments were conducted using propylene-nitrogen-oxygen upon pressure changes at 200 ℃. At 21% oxygen, as pressure increased from 0.10 MPa to 0.25 MPa, lower explosion limit (LEL) decreased from 2.2% to 1.9% while upper explosion limit (UEL) increased from 14.8% to 17.6%. In addition, minimum oxygen concentration (MOC) decreased from 10.3% to 10.0%, indicating higher risks with the expanded explosive range as pressure increased. With increase of pressure from 0.10 MPa to 0.25 MPa, explosion pressure increased from 1.84 MPa to 6.04 MPa, and the rate of rise of maximum explosion pressure increased drastically from 90 MPa/s to 298 MPa/s. It is hoped that these results can be used as basic data to prevent accidents in factories using propylene.

A Comparison Study on Severe Accident Risks Between PWR and PHWR Plants (가압 경수로 및 가압중수로형 원자력 발전소의 중대사고 리스크 비교 평가)

  • Jeong, Jong-Tae;Kim, Tae-Woon;Ha, Jae-Joo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.3
    • /
    • pp.187-196
    • /
    • 2004
  • The health effects resulting from severe accidents of typical 1,000MWe KSNP(Korea Standard Nuclear Plant) PWR and typical 600MWe CANDU(CANada Deuterium Uranium) plants were estimated and compared. The population distribution of the site extending to 80km for both site were considered. The releaese fraction for various source term categories(STC) and core inventories were used in the estimation of the health effects risks by using the MACCS2(MELCOR Accident Consequence Code System2) code. Individuals are assumed to evacuate beyond 16km from the site. The health effects considered in this comparative study are early and cancer fatality risk, and the results are presented as CCDF(Complementary Cumulative Distribution Function) curves considering the occurrence probability of each STC's. According to the results, the early and cancer fatality risks of PHWR plants we lower than those of PWR plants. This is attributed the fact that the amount of radioactive mateials that released to the atmosphere resulting from the postulated severe accidents of PHWR plants are smaller than that of PWR plants. And, the dominating initiating event of STC that shows maximum early and cancer fatality risk is SGTR(Steam Generator Tube Rupture) for both plants. Therefore, the appropriated actions must be taken to reduce the occurrence probability and the amounts of radioactive materials released to the environment in order to protect the public for both PWR and PHWR plants.

Smoke Control Performance of a Serial Structure Using "CONTAM" (CONTAM을 이용한 직렬형태 구조의 제연성능 구현에 관한 연구)

  • Kim, Mi-Seon;Seo, Dong-Gil;Gu, Seon-Hwan;Yoo, Young-Min;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.53-62
    • /
    • 2019
  • A recent trend shows that more buildings are being constructed as mixed-use (residential and commercial) properties for efficient land use. This has led to an increased frequency in the occurrence of fires and the associated potential risks. In particular, in case of high-rise apartments, at least one of the elevators in each building is installed for evacuation purposes separately from the emergency elevator; therefore, for a combined ancillary room and emergency elevator platform situation, the structure is inevitably in series with the evacuation elevator platform. Thus, a proposal for a new type of ventilation zone based on existing national fire safety codes is required to achieve smoke control performance. To this end, the air egress velocity and differential pressure of each ventilation zone are checked using the "CONTAM" software; further, an alternative is proposed to secure smoke control performance for series structures.

Influence of Heavy Metals, Ammonia, and Organotin Compounds on the Survival of Arkshell Clams, Scapharca broughtonii (중금속, 암모니아, 유기주석화합물이 피조개 (Scapharca broughtonii) 의 생존에 미치는 영향)

  • Kim, Chan-Kook;Kim, Dong-Hoon;Lee, Jung-Suk;Lee, Kyu-Tae
    • The Korean Journal of Malacology
    • /
    • v.20 no.1
    • /
    • pp.93-105
    • /
    • 2004
  • Arkshell clams, Scapharca broughtonii, are economically important edible bivalves and widely cultivated in the Southern coast of Korea. Recently, the production of S. broughtonii has been dramatically decreased and various reasons including chemical pollution were suspected to be related to the production declines. However, it remains unknown whether the chemical pollution levels of the surrounding environments were high enough for the biological and ecological disturbance for the population of S. broughtonii, because no systematic toxicological study using S. broughtonii has been conducted previously. In the present study, we exposed arkshell clams, S. broughtonii to various waterborne pollutants including heavy metals (Cd, Cu and Hg), ammonia and organotins (tributyltin and triphenyltin) to determine the effect concentrations of these pollutants for the survival of S. broughtonii for 20 days. The median lethal concentrations ($LC_50$) of S. broughtonii were 2.1 mg/l for Cd, 0.065 mg/l for Cu, 0.40 mg/l for Hg, 79.4 mg/l for total ammonia (1.9 mg/l for unionized ammonia), 0.5 ${\mu}$g/l for TBT, and 14${\mu}$g/l for TPhT. Lethal toxicity of the most pollutants increased with both exposure duration and concentration. The toxicity of TBT was greatest for S. broughtonii, followed by TPhT > Cu > Hg > Cd > ammonia. The sensitivities of S. broughtonii to heavy metals and TBT were comparable to those of other aquatic organisms, but they were relatively tolerable to ammonia. The environmental concentrations of the tested pollutants were compared with the effect concentrations of those for the survival of S. broughtonii to assess the potential risks of the pollutants in the field conditions.

  • PDF

A Study on Fire Hazard Analysis and Smoke Flowing for the Semiconductor Manufacturing Process (반도체 제조공정의 연기유동에 관한 연구)

  • Han, Soo-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.197-211
    • /
    • 2007
  • The power of semiconductor, Korea is continuously constructing semiconductor production line for keeping a front-runner status. however, studies and data about potential risks in semiconductor factory are still short. If fire does not initially suppressed, the fire causes a great damage. To decrease fire risk factors, in addition to fire fighting safety equipment, more important thing is how to design and construct fire protection system. The current fire protection codes about semiconductor factory come under functional law, and this law is short of consideration about particularity of factory. The existing prescriptive fire codes depending on experience compose without evident engineering verifications, thus equipments which is created by the current prescriptive fire code may bring about a variety of problems. For example, the design under the current regulation can not cope with the excessive investments, low efficiencies, and the diversifying construction designs and be applied to the quick changes of new technologies. Ergo, an optimal design for fire protection is to equip fire protection arrangements with condition and environment of production field. Manufacturing factory of semiconductors is a windowless airtight space. And for cleanliness, there exists strong flow of cooperation. Therefore, there is a need for fire safety design that meets the characteristic of a clean room. Accordingly, we are to derive smoke flow according to cooperation process within a clean room and construction plan of an optimal sensor system. In this study, in order to confirm the performance of proposed smoke-exhaust equipment and suggest efficient smoke exhaust device when there is a fire of 1MW of methane in the clean room of company H, we have implemented fire simulation using fluid dynamics computation.

Safety Enhancement of LPG Terminal by LOPA & SIF Method (LOPA 및 SIF기법에 의한 LPG 인수기지의 안전성향상에 대한 연구)

  • Lee, Il Jae;Kim, Rae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.431-439
    • /
    • 2015
  • The methods which decrease the accident hazards of LPG(Liquefied Petroleum Gas) terminal on the basis of butane & propane storage tanks by applying HAZOP(Hazard and Operability), LOPA(Layer of Protection Analysis) and SIL(Safety Integrity Level) are suggested. The accident scenarios were derived by analyzing latent risks through the HAZOP. The scenarios which would have the big damage effect in accidents were selected and then LOPA was assessed by analyzing IPL(Independent Protection Layer) about the correspond accident scenarios. The improved methods were proposed on the basis of level of SIF(Safety Instrumented Functions) as a IPL considering satisfied condition of risk tolerance criteria($1.0{\times}10^{-05}/y$). In addition, The proposed IPLs were basis on the economic analysis. The effect of SIF as a IPL considering the changes of accident frequency was studied in case of the accident scenarios derived from the concerned process.

A Study on Risk Assessments and Protection Improvement for Electric Power Infrastructures against High-altitude Electromagnetic Pulse (전력기반시설의 고 고도 핵 전자기파에 대한 위험성 검토 및 방호 개선방안 연구)

  • Chung, Yeon-Choon
    • Convergence Security Journal
    • /
    • v.19 no.3
    • /
    • pp.43-50
    • /
    • 2019
  • In a hyper-connected society, electric power infrastructures and information and communication infrastructures are the core of critical national infrastructures. However, electric power infrastructure is very deadly to high-frequency nuclear electromagnetic pulse (HEMP) threats recently issued by North Korea, so the resilience through rapid recovery after attack is directly related to the survivability of our country. Therefore, electric power infrastructure should take precedence over any other key infrastructure, with preemptive protection measures and fast recovery plans. In this paper, the characteristics of the HEMP threats was examined, and the risks and effective major protection measures of the electric power infrastructures are discussed. In the future, it is expected that it will be able to help establish the direction of enactment and revision of legal schems related to the 'high power EMP infringement prevention' for Korea's electric power infrastructures.

The IOA-Based Intelligent Information Protection System for Response of Advanced Persistent Threats (IOA 기반의 지능형지속위협 대응 위한 지능형 정보보호시스템)

  • Ryu, Chang-su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2067-2072
    • /
    • 2016
  • Recently, due to the development of attack techniques that can circumvent existing information protection systems, continuous threats in a form unrecognized by the user have threatened information assets. Therefore, it is necessary to support the prompt responses to anticipated attempts of APT attacks, bypass access attacks, and encryption packet attacks, which the existing systems have difficulty defending against through a single response, and to continuously monitor information protection systems with a defense strategy based on Indicators of Attack (IOA). In this paper, I suggest a centralized intelligent information protection system to support the intelligent response to a violation by discerning important assets through prevention control in a performance impact assessment about information properties in order to block the attack routes of APT; establishing information control policies through weakness/risk analyses in order to remove the risks in advance; establishing detection control by restricting interior/exterior bypass networks to server access and monitoring encrypted communications; and lastly, performing related corrective control through backup/restoration.

Developing Green Bank Operation In India And Vietnam: Comparison And Evaluation

  • DANG, Thuy T.;NGUYEN, Trang Thu
    • Asian Journal of Business Environment
    • /
    • v.11 no.3
    • /
    • pp.33-43
    • /
    • 2021
  • Purpose: The purpose of the paper is to assess the greening of investment flows as well as the orientation of financial sources of effective environmental protection. Both India and Vietnam are considered to be two Asian countries that are radically affected by global climate change. Governments of the two countries have implimented numerous measures against environmental pollution through the banking and finance sector. Developing green banking operations in India and Vietnam is a new direction in the socio-economic development strategy coupled with effective environmental protection. Research design, data and methodology: The data was mainly based on Asia Development Bank Institution (ADBI) and Bank of India (BOI) from 2015 - 2018. This paper focused on comparing and evaluating the development of green banks between the two countries. Result: The banks' contribution to green growth and green economy is shown in two basic aspects: (i) the connection between organizations, and individuals, and management process for investment projects, including environmental risks; and (ii) the operation of banks has a direct impact on the environment, through the application of technology to pay documents and apply e-banking. Conclusion: Paper reflects, compares and evaluates green banking operations in India and Vietnam to provide new directions aiming to develop financial and economic system along with effective and efficient step toward climate change control. India's green banking operations, after a specific assessment, will be lessons for the Government of Vietnam during the process of socio-economic development and environmental protection.

Evaluating the Protective Effectiveness of Rubber Glove Materials Against Organic Solvents Upon Repeated Exposure and Decontamination

  • Li-Wen Liu;Cheng-Ping Chang;Yu-Wen Lin;Wei-Ming Chu
    • Safety and Health at Work
    • /
    • v.15 no.2
    • /
    • pp.228-235
    • /
    • 2024
  • Background: Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency. Methods: The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA. Results: At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ∆SBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance. Conclusions: Thermal aeration at 100℃ for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.