• Title/Summary/Keyword: protection facility

Search Result 406, Processing Time 0.026 seconds

Study on the Decommissioning of Small Nuclear Facility through Analyzing Foreign Decommissioning Practices (국외 해체 사례 분석을 통한 국내 소규모 방사선이용시설 해체에 관한 연구)

  • Kwon, Dayeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.125-130
    • /
    • 2015
  • RI & RG are used in various field such as medical field, industrial field, agricultural and food&life field. The number of small nuclear facilities is on the increase. We need to take an interest in decommissioning of small nuclear facility and predict the occurring problem from facility decommissioning. Because of the relatively low radiation risk, the preparation of the small nuclear facility dismantling is often neglected. As the accident in Goiania, Brazil showed, the impact of the decommissioning of small nuclear facilities is not less than the large nuclear facilities although it may seem dangerless. Therefore, we analyzed the each institutional characteristics of the decommissioning of small nuclear facilities through foreign case study on this research. Also, we proposed several considerations on decommissioning such as reuse of facility and source, lack of space, stakeholder involvement and failures of protection. Through these study, we tried to make guideline of the small nuclear facilities decommissioning.

A Study on Effective Fire Countermeasures for Facilities for the Elderly and Children (노유자시설의 효율적인 화재 대응방안에 관한 연구)

  • Hwang, Euy-Hong;Choi, Han-Bit;Choi, Doon-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.107-114
    • /
    • 2020
  • With the development of the national industry, the importance of the elderly and children such as the elderly, disabled, and children is recognized. Similarly, the number of facilities for the elderly and children is increasing. Fires at facilities for the elderly and children cause heavy casualties. In response to these events, it is essential to activate fire alarms promptly and accurately and to secure evacuation routes. In this study, the laws and statistics related to facilities for elderly and children were reviewed, and problems with legal terms-such as elderly, children, others, unwanted alarm of fire alarm systems, blind spots of fire compartment standards, securing evacuation routes, and absence of standards for life safety rescue organizations-were identified. As an improvement measure, the legal definitions of similar terms-such as elderly, children, unwanted alarm checklist, and establishment of standards for fire prevention compartment-and introduction of other terms-evacuation elevators, the establishment of standards for life-safety rescue organizations, and provision of flame retardation objects for evacuees-were proposed.

A Study on Assesment of Aalidity of Introducing of Design·Construction·Supervision Register Criteria Measures for Hazardous Materials Facilities (위험물시설의 설계·시공·감리업 등록제 도입에 대한 타당성 검토에 관한 연구)

  • Cha, Jung-Min;Lee, Yong-Jae;Kim, In-Beom;Hyun, Seong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.27-37
    • /
    • 2015
  • This study is to analyze current inadequate status of installing hazardous materials facilities, and to propose rational standards by researching validity for implementing registration for design, construction, supervision for installing fire safety facilities. By studying installation of registering designing, constructing, supervising industry on hazardous material facilities, professional and higher level of stability measures for national hazardous material facility was provided. For above reasons, necessity of institutionalizing of registering standards for construction and supervising industry became clear. Much more gradual institutionalization is needed for construction industry. Moreover, new national qualification should be reconsidered, in order to rebuttal the above and also to cultivate and acquire technical power.

A Study on the Funeral director's working Circumstances and Management Facilities associated Infection Disease on Funeral home (국내 안치실 및 염습실 종사자의 근무환경 및 질병관리시설현황에 대한 연구)

  • Hwang, Kyu-Sung;Chang, Man-Suck;Jin, Sang-Myoung;Kim, Jeong-Lae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.2 no.3
    • /
    • pp.1-7
    • /
    • 2016
  • Infection of the disease that are propagated through a dead body of management and transportation must be very careful. Risk of infection that can occur between the deceased body and funeral directors, guideline of the preparation room and infection route of infection source has been studies in Korea. But the funeral director's working circumstances and infection blocking facility of the funeral home has not been studied in Korea. So we are investigated about the state of the working circumstances and Infection blocking facility within Metropolitan, Chungcheong and Gyeongsang regions in Korea. The result is as follows. The funeral directors have shown that there is difficult to get safe protection from infection. The personal hygiene of funeral directors and the infection blocking facility should be strengthened institutionally. We are thought to require more in-depth research about the working circumstances of funeral director and the infection blocking facility.

Development of B-Value Based GBAS Ground Facility Error Standard Deviation Model and Verification (B-Value를 이용한 GBAS 지상국 오차 표준편차 모델 개발 및 성능 평가)

  • Jun, Hyang-Sig;Ahn, Jong-Sun;Lee, Young-Jae;Choi, Young-Kiu;Sung, Sang-Kyung;Yeom, Chan-Hong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.12
    • /
    • pp.1232-1237
    • /
    • 2009
  • The ICAO and FAA are developing and verifying of GBAS for civil aircraft landing and take-off. The guarantee of aircraft integrity issue is the important part of GBAS. To guarantee integrity, the GBAS ground facility broadcasts various informations to aircraft. The informations are related to the estimated accuracy of each pseudorange correction and the estimated error terms, for example B-value and standard deviation of the ground facility error. These parameters are used to calculate position error (estimated value of the user). If estimated position errors don't satisfy requirements, aircraft use alternate navigation means. In this paper, GBAS reference stations's real data, which operated by KARI (Korea Aerospace Research Institute) in Jeju international airport, are used to development of new ground facility error standard deviation model. We verify improvement of GBAS availability, with respected to vertical protection level, using B-value based a new ground facility error standard deviation model and a sigma inflation factor.

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

Comparative Analysis of Overseas Guidelines for Seclusion Room of Psychiatric Facilities (정신의료기관 보호실 대상 해외 가이드라인 비교분석 연구)

  • Lee, Seungji;Yoon, Sunyoung;Yeo, Soyeon;Park, Dohee;Baek, Jinhee;Kim, Sunghyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.2
    • /
    • pp.7-16
    • /
    • 2023
  • Purpose: Seclusion room in a psychiatric facility limit the body and space for treatment or protection, so controversy over human rights violations arises despite their necessity. The seclusion room should be created as an environment that can promote the recovery and healing of patients, not the purpose of managing patients. while ensuring the safety of medical staff. Therefore, the purpose of this study is to compare and analyze the standards of overseas guidelines for the seclusion room in psychiatric facility, and through this, it is intended to contribute to the improvement of facility standards for seclusion rooms in Korea, which are at a very insufficient level. Method: This study takes the method of comparative analysis through literature review. We analyze the facility standards of seclusion room in Korea, and compare and analyze guidelines for seclusion rooms in Australia, US, UK, and Canada. Result: As a result, the elements of the guideline for seclusion room were classified into size, space, opening, furniture and equipment, and etc. The results of comparative analysis of details are presented. Implications: Korea should also prepare guidelines for psychiatric institutions, and among them, the standards for seclusion room, which are at the center of controversy over human rights violations, should be reviewed in depth.

The research regarding the community residential welfare facilities for the Aged - Focused on instance of the United States - (지역사회 노인주거시설에 관한 연구 - 미국을 중심으로 -)

  • Cho, Cheol-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.2
    • /
    • pp.225-233
    • /
    • 2010
  • At this point in time South Korea is rapidly metastasizing to a aging society. A major cause of aging can be summarized as increased life expectancy, decrease of nuclear family and birthrate, and South Korea's progress is faster than any other country. From the 1970s, western society has changed social welfare to deinstitutionalization and community care because of problems about economic reason and facilities protection, so the type of elderly social service has also changed from the facility welfare service which is accommodated old people in certain facility to community welfare service which provides various welfare services with living together. Public facilities for low income group which are supported by government are lower, 6.6%, than the United States or Japan, 50%. They are divided into private manage facilities and subscription elderly facilities. These subscription elderly residential facilities show poor administration because of focusing on development and market analysis for investment returns. Therefore, in order to vitalize the elderly welfare residential facilities in Korea, we need plans about systematic services facilities for welfare and phased medical treatments. Therefore, the purpose of this study is that (1) the types and functions of residents for community elderly residential facilities in elderly welfare policies of U.S., and supported policies are researched as a transcendental model, (2) data about operating system with the principles of the market is analyzed, and (3) basic data about welfare facility plan for community residential elderly people is provided.

A Study on the Fire Protection System in the Stage (공연장의 소방시설 설치기준의 개선방안에 관한 연구)

  • 장상태;이영재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-19
    • /
    • 1999
  • Currently, conventional fire prevention facility installation standard is based on the use and size of the domestic theaters. In the study, theaters with 1,900 seats were examined to suggest a suitable method to adapt a better fire preventing system. The proposed systems are as follow. - 100% of backup pressed-water outlet device, considering waterproof pressure for fire prevention facility at the top floor. - The supplement of the side wall type header and a large caliber outlet header for stage open sprinkler. - Subdividing a installation rule for special detector and implementing the latestdetector. - Installation of fire curtain for dividing stage area and auditorium area, and also the method of installation of fire curtain.

  • PDF

Prediction of the Blast Wave Propagation Over a Kick Motor Test Facility (Kick Motor 시험장 충격파 전파 예측)

  • Ok, Ho-Nam;Kim, In-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.220-223
    • /
    • 2008
  • A test facility to measure the performance of a KM(Kick Motor) is constructed, and prediction of blast wave propagation over the facility is performed to check if the safety of test personnel in MCC(Main Control Center) can be guaranteed even for the most severe explosion. Assuming that the initial explosion energy is contained in a sphere under the pressure of 500, 1000, 1500 psi, respectively, the radius of the sphere is determined for each pressure to set the mass of contained explosion gas to 35 kg. The material properties of explosion gas are set to be the ones of KM propellant combustion gas under normal condition. To reduce the effort and time required for a complex three-dimensional modeling, the flowfield is approximated to axismmetry. Calculations are performed for all three initial pressure conditions, and the analysis of the result is given for 1500 psi which is expected to be the worst case. The maximum pressure is 3.5 psig while the minimum pressure is -1.2 psig on the outer wall of MCC, and the maximum pressure difference between the inner and outer walls of protection wall amounts to 3.0 psi.

  • PDF