• 제목/요약/키워드: protection efficiency

검색결과 947건 처리시간 0.025초

Near-explosion protection method of π-section reinforced concrete beam

  • Sun, Qixin;Liu, Chao
    • Geomechanics and Engineering
    • /
    • 제28권3호
    • /
    • pp.209-224
    • /
    • 2022
  • In this study, the numerical analysis model of π-beam explosion is established to compare and analyze the failure modes of the π-beam under the action of explosive loads, thus verifying the accuracy of the numerical model. Then, based on the numerical analysis of different protection forms of π beams under explosive loads, the peak pressure of π beam under different protection conditions, the law of structural energy consumption, the damage pattern of the π beam after protection, and the protection efficiency of different protective layers was studied. The testing results indicate that the pressure peak of π beam is relatively small under the combined protection of steel plate and aluminum foam, and the peak value of pressure decays quickly along the beam longitudinal. Besides, as the longitudinal distance increases, the pressure peak attenuates most heavily on the roof's explosion-facing surface. Meanwhile, the combined protective layer has a strong energy consumption capacity, the energy consumed accounts for 90% of the three parts of the π beam (concrete, steel, and protective layer). The damaged area of π beam is relatively small under the combined protection of steel plate and aluminum foam. We also calculate the protection efficiency of π beams under different protection conditions using the maximum spalling area of concrete. The results show that the protective efficiency of the combined protective layer is 45%, demonstrating a relatively good protective ability.

소재에 따른 자외선.복사열 차단력 (Protection Efficiency from Solar Radiation and Ultraviolet Radiation by Fabrics)

  • 김경수;최정화
    • 대한가정학회지
    • /
    • 제40권10호
    • /
    • pp.77-85
    • /
    • 2002
  • This study was conducted to evaluate the efficiency of various fabrics in protecting from solar radiation and ultraviolet radiation(UV). Six kinds of fabrics were selected and examined in singles or doubles. It was studied how the materials and the thickness of air layer between the fabric and the floor affected the protection efficiency of fabrics from sunlight. The results were as followes; 1) Protection from solar radiation: In the case of over 2 cm air layer, doubled fabric composed of aluminum coating-nylon and white or black polyester/cotton(T/C) was the most protective(p<0.001). In the case of 0 cm air layer, the case without fabric and white T/C were more effective(p<0.001). And the thicker the air layer the more effective the protection. 2) Protection from UV : Doubled fabric composed of aluminum coating-nylon and black T/C was the most protective(p<0.001) and the thinner the air layer the more effective the protection(p<0.001).

기업의 정보보호활동의 효율성 평가 (An Evaluation of the Efficiency of Information Protection Activities of Private Companies)

  • 최원녕;김우제;국광호
    • 융합보안논문지
    • /
    • 제18권5_1호
    • /
    • pp.25-32
    • /
    • 2018
  • 해킹 공격이 지능화되고 증가됨에 따라 공공 및 민간기업들은 중요한 자산 및 개인정보를 보호하기 위해 많은 비용을 투자하고 정보보호인력을 충원하여 다양한 정보보호활동을 진행하고 있다. 이와 함께 많은 비용과 인력을 요구하는 정보보호활동이 효율적으로 수행되고 있는지를 평가하는 것은 매우 중요하다. 하지만 정보보호 효율성 평가연구는 주로 정보수집이 보다 수월한 정부기관에 대해서 행해져 왔다. 본 연구는 다양한 민간 기업들의 정보보호인증 및 정보보호활동에 대한 효율성을 평가하는 모델을 제시하는데 목적이 있다. 이를 위해 민간 기업들의 정보보호활동에 대한 공시된 자료인 정보보호공시 정보를 활용하여 계층구조분석(AHP) 과 자료포락분석(DEA) 기법을 적용하여 정보보호 효율성을 평가하였다. 또한 효율성 평가 모델을 통해 효율적으로 운영되고 있는 DMU를 선별하고 비효율적인 DMU들이 효율적으로 운영하기 위해 개선되어야 할 보안활동요소들에 대해 알아본다.

  • PDF

자외선 차단제품에서 자외선차단지수(SPF)와 자외선A차단등급(PA)에 영향을 주는 인자에 관한 연구 (A Study on the Factors that Influence the Sun Protection Factor(SPF) and Protection Factor of UV-A(PA) in Sunscreen)

  • 연제영;서정민;배준태;이청희;이상길;표형배;홍진태
    • 한국응용과학기술학회지
    • /
    • 제31권3호
    • /
    • pp.422-439
    • /
    • 2014
  • 본 연구에서는 자외선 차단제품에서 오일의 극성도, 에멀젼의 종류, 제품의 점도, 증점제의 종류 그리고 광안정제 등이 자외선 차단 효율에 미치는 영향을 조사해 보았다. 그 결과 오일의 극성도가 높으면 자외선 차단 효과는 높게 측정되었으며(Butyloctyl salicylate: SPF 44.10, PA 7.93), 반대로 오일의 극성도가 낮으면 자외선 차단 효과는 낮게 측정되었다(Dimethicone: SPF 16.40, PA 5.57). 에멀젼의 종류는 O/W 에멀젼보다 유기 자외선 차단제가 외상에 존재하는 W/O 에멀젼에서 자외선 차단 효율이 더 높게 측정되었다. 제품의 점도는 높아질수록 자외선 차단 효율이 비례적으로 상승하는 경향을 나타내었으며, 증점제의 종류 및 유화입자 크기는 자외선 차단 효과에 미치는 영향이 크지 않았다. 또한 광안정제의 함유 여부도 자외선 차단 효율에 영향을 미치는 중요한 인자 중의 하나로 나타났다. 이러한 결과들은 자외선 차단제의 추가적인 증량이 없어도 자외선 차단 효율을 더 높일 수 있음을 의미하는 것으로, 앞으로 자외선 차단제품 개발 시 경제적 효율성을 높이는데 큰 도움이 될 것으로 사료된다.

Experimental technique for efficiency transfer along different geometries and volumes

  • Haddad, Kh;AL-Homyed, A.
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.695-698
    • /
    • 2021
  • Efficiency calibration is a fundamental procedure in gamma spectrometric measurement. Experimental technique for efficiency calibration transfer in gamma spectrometer along different geometries and volumes has been developed and validated in this work. The developed technique offers simple and easy procedures to overcome several problems encountered in efficiency calibration of gamma spectrometer such as rate-related correction and different sample volumes. The validation shows that application of the developed technique has a precision of 95%.

Measuring Thermo-luminescence Efficiency of TLD-2000 Detectors to Different Energy Photons

  • Xie, Wei-min;Chen, Bao-wei;Han, Yi;Yang, Zhong-Jian
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.179-183
    • /
    • 2016
  • Background: As an important detecting device, TLD is a widely used in the radiation monitoring. It is essential for us to study the property of detecting element. The aim of this study is to calculate the thermo-luminescence efficiency of TL elements. Materials and Methods: A batch of thermo-luminescence elements were irradiated by the filtered X-ray beams of average energies in the range 40-200 kVp, 662 keV $^{137}Cs$ gamma rays and then the amounts of lights were measured by the TL reader. The deposition energies in elements were calculated by theory formula and Monte Carlo simulation. The unit absorbed dose in elements by photons with different energies corresponding to the amounts of lights was calculated, which is called the thermo luminescent efficiency (${\eta}^{(E)}$). Because of the amounts of lights can be calculated by the absorbed dose in elements multiply ${\eta}^{(E)}$, the ${\eta}^{(E)}$ can be calculated by the experimental data (the amounts of lights) divided by absorbed dose. Results and Discussion: The deviation of simulation results compared with theoretical calculation results were less than 5%, so the absorbed dose in elements was calculated by simulation results in here. The change range of ${\eta}^{(E)}$ value, relative to 662 keV $^{137}Cs$ gamma rays, is about 30% in the energy range of 33 keV to 662 keV, is in accordance by the comparison with relevant foreign literatures. Conclusion: The ${\eta}^{(E)}$ values can be used for updating the amounts of lights that are got by the direct ratio assumed relations with deposition energy in TL elements, which can largely reduce the error of calculation results of the amounts of lights. These data can be used for the design of individual dosimeter which used TLD-2000 thermo-luminescence elements, also have a certain reference value for manufacturer to improve the energy-response performance of TL elements by formulation adjustment.

Efficiency of Marine Hydropower Farms Consisting of MultipleVertical Axis Cross-Flow Turbines

  • Georgescu, Andrei-Mugur;Georgescu, Sanda-Carmen;Cosoiu, Costin Ioan;Alboiu, Nicolae
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.150-160
    • /
    • 2011
  • This study focuses on the Achard turbine, a vertical axis, cross-flow, marine current turbine module. Similar modules can be superposed to form towers. A marine or river hydropower farm consists of a cluster of barges, each gathering several parallel rows of towers, running in stabilized current. Two-dimensional numerical modelling is performed in a horizontal cross-section of all towers, using FLUENT and COMSOL Multiphysics. Numerical models validation with experimental results is performed through the velocity distribution, depicted by Acoustic Doppler Velocimetry, in the wake of the middle turbine within a farm model. As long as the numerical flow in the wake fits the experiments, the numerical results for the power coefficient (turbine efficiency) are trustworthy. The overall farm efficiency, with respect to the spatial arrangement of the towers, was depicted by 2D modelling of the unsteady flow inside the farm, using COMSOL Multiphysics. Rows of overlapping parallel towers ensure the increase of global efficiency of the farm.

제주 송이를 이용한 견직물의 염색성 및 기능성 (Dyeability and Functionality of Silk Fabrics Dyed with Jeju scoria)

  • 임은숙;이혜선;한충훈
    • 한국염색가공학회지
    • /
    • 제23권3호
    • /
    • pp.187-194
    • /
    • 2011
  • This study used Jeju scoria to dye cotton fabric and measured its dyeability, colorfastness, antibacterial activity, deodorization efficiency, ultraviolet protection, and far-infrared emission. The cotton fabric was colored to yellowish red and optimal dyeing can be achieved at a temperature of $80^{\circ}C$ for a dyeing time of 120 minutes with a colorant concentration of 25%(o.w.b). The colorfastness to light, rubbing, perspiration, and washing was 8, 5, 5, and 4~5 ratings respectively, where the wash colorfastness remained after 15 wash cycles. The cotton fabric dyed with Jeju scoria demonstrated excellent antimicrobial activity to Staphylococcus aureus and high deodorization efficiency. Ultraviolet protection factor was as high as 50+. The Jeju scoria can be used as a new colorant for the natural dyeing of silk.

콘크리트 구조물의 염해도장을 통한 내구성능 향상 및 경제적 효과분석 (Analysis on Durability Performance Enhancement and Economical Efficiency through Chloride Protection for Concrete Structures)

  • 채원규;김성헌;손영현;박주원;이증빈
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.155-160
    • /
    • 2010
  • In this study, detailed assessment for durability performance were performed on the chloride protected concrete structures to investigate the effectiveness of chloride protection. And economical efficiency for the chloride protected concrete structures were studied by LCC(Life Cycle Cost) analysis. In the comparison result of the first section repair time, it was found that the chloride protected concrete structures was economical better than the non-protected concrete structures in the long term. According to the analysis result of the accumulated chloride concentration by used time and chloride ion concentration by depth, it can be seen that the permeation through time from chloride has increased two times in the chloride protected concrete structures.