• Title/Summary/Keyword: protection distance

Search Result 531, Processing Time 0.023 seconds

Generalized Digital Prolate Spheroidal Sequences in Digital Distance Protection

  • Chung, Sae-Young;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.55-58
    • /
    • 1991
  • A generalization to the Digital Prolate Spheroidal Sequences is investigated, so that the Generalized Digital Prolate Spheroidal Sequences(GDPSS's) can be used as a powerful time window with many desirable properties. The GDPSS's in the form of the time window has 3 parameters with which we can control the shape of the window freely. Hence, GDPSS's can be used as the very useful time windows especially for digital distance protection.

  • PDF

Analysis on the Interference Effect of WLAN on WiBro (무선랜에 의한 WiBro 간섭 영향 분석)

  • Shim, Yong-Sup;Lee, Il-Kyoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.95-100
    • /
    • 2011
  • This paper analyzes the interference effect of WLAN(Wireless Local Area Network) service on WiBro(Wireless Broadband) service in adjacent frequency band by using Monte Carlo method. For the analysis, we make scenario that WLAN service operates on frequency band of 2401 MHz ~ 2423 MHz and WiBro service operates on frequency band of 698 MHz ~ 704 MHz. In case of WiBro receiver is close to WLAN AP(Access Point), the interference will be increased. So, we calculate the protection distance between WiBro receiver and WLAN AP to meet interference probability of 5 % below and required interference power of WLAN AP to meet interference probability of 5 % below in the case of fixed protection distance. As a result, the protection distance of 60 m and -9.5 dBm of required interference power of WLAN AP at 10 m of the fixed protection distance are analyzed.

Road Network Distance based User Privacy Protection Scheme in Location-based Services (위치 기반 서비스에서 도로 네트워크의 거리 정보를 이용한 사용자 정보 은닉 기법)

  • Kim, Hyeong Il;Shin, Young Sung;Chang, Jae Woo
    • Spatial Information Research
    • /
    • v.20 no.5
    • /
    • pp.57-66
    • /
    • 2012
  • Recent development in wireless communication technology like GPS as well as mobile equipments like PDA and cellular phone makes location-based services (LBSs) popular. However, because users request a query to LBS servers by using their exact locations while moving on the road network, users' privacy may not be protected in the LBSs. Therefore, a mechanism for users' privacy protection is required for the safe and comfortable use of LBSs by mobile users. For this, we, in this paper, propose a road network distance based cloaking scheme supporting user privacy protection in location-based services. The proposed scheme creates a cloaking area by considering road network distance, in order to support the efficient and safe LBSs on the road network. Finally, we show from our performance analysis that our cloaking scheme outperforms the existing cloaking scheme in terms of cloaking area and service time.

Radiation exposure to the eyes and thyroid during C-arm fluoroscopy-guided cervical epidural injections is far below the safety limit

  • Choi, Eun Joo;Go, Gwangcheol;Han, Woong Ki;Lee, Pyung-Bok
    • The Korean Journal of Pain
    • /
    • v.33 no.1
    • /
    • pp.73-80
    • /
    • 2020
  • Background: The aim of this study was to evaluate radiation exposure to the eye and thyroid in pain physicians during the fluoroscopy-guided cervical epidural block (CEB). Methods: Two pain physicians (a fellow and a professor) who regularly performed C-arm fluoroscopy-guided CEBs were included. Seven dosimeters were used to measure radiation exposure, five of which were placed on the physician (forehead, inside and outside of the thyroid protector, and inside and outside of the lead apron) and two were used as controls. Patient age, sex, height, and weight were noted, as were radiation exposure time, absorbed radiation dose, and distance from the X-ray field center to the physician. Results: One hundred CEB procedures using C-arm fluoroscopy were performed on comparable patients. Only the distance from the X-ray field center to the physician was significantly different between the two physicians (fellow: 37.5 ± 2.1 cm, professor: 41.2 ± 3.6 cm, P = 0.03). The use of lead-based protection effectively decreased the absorbed radiation dose by up to 35%. Conclusions: Although there was no difference in radiation exposure between the professor and the fellow, there was a difference in the distance from the X-ray field during the CEBs. Further, radiation exposure can be minimized if proper protection (thyroid protector, leaded apron, and eyewear) is used, even if the distance between the X-ray beam and the pain physician is small. Damage from frequent, low-dose radiation exposure is not yet fully understood. Therefore, safety measures, including lead-based protection, should always be enforced.

Power Swing Detection Using rms Current Measurements

  • Taheri, Behrooz;Razavi, Farzad
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1831-1840
    • /
    • 2018
  • During a power swing, distance relays may mistakenly spread fault throughout the power grid, causing a great deal of damage. In some cases, such mistakes can cause global outages. For this reason, it is critical to make a distinction between power swings and faults in distance relays. In this paper, a new method is proposed based on RMS measurement to differentiate between faults and power swings. The proposed method was tested on two standard grids, demonstrating its capability in detecting a power swing and simultaneous fault with power swing. This method required no specific configurations, and was independent of grid type and zoning type of distance relays. This feature in practice allows the relay to be installed on any grid with any kind of coordination. In protective relays, the calculations applied to the microprocessor is of great importance. Distance relays are constantly calculating the current RMS values for protection purposes. This mitigates the computations in the microprocessor to detect power swings. The proposed method was able to differentiate between a fault and a power swing. Furthermore, it managed to detect faults occurring simultaneously with power swings.

Experimental Examinations on Protective Effects of SPDs Associated with the Protective Distance and Type of Load (보호거리와 부하 유형에 따른 SPD의 보호효과에 대한 실험적 고찰)

  • Lee, Bok-Hee;Kim, You-Ha;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.81-88
    • /
    • 2012
  • Surge protective devices(SPDs) are widely used as a most effective means protecting the electrical and electronic equipment against overvoltages such as lightning and switching surges. When installing SPDs, it is essential that the voltage protection level provided by SPDs should be lower than the withstand voltage of the equipment being protected. But even the proper selection of SPDs are achieved, the voltage at the equipment terminal may be higher than the residual voltage of SPD due to the reflection and oscillation phenomena. This paper was focused on the investigations of the conditions for which the equipment is protected by an SPD taking into account the influences of the protective distance and type of load. The protective effects of SPD with voltage-limiting component were analyzed as functions of types of load and protective distance between the SPD and load. As a result, in the cases of long protective distances, capacitive loads and loads with high resistance, the voltage at the load terminal was significantly higher than the residual voltage of SPD. It was found that the proper installation of SPDs should be carried out by taking into account the protective distance and type of load to achieve reliable protection of electronic equipments against surges.

A Study on The Development and Evaluation of Mine Detective Gear (지뢰 탐지용 방호복 구성과 방호성능 및 착용감 평가)

  • 손부현;최혜선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.4
    • /
    • pp.707-718
    • /
    • 2001
  • The purpose of this study is to evaluate a newly developed protective suit with the fragments of grenade. The protection efficiency should be strengthened upon the degree of wound. The fragment weight of the used grenade was measured and the kinetic energy of the maximum speed of the fragments in the field test was 137.7J and this could be the protective efficiency test by the multitude fragments in less than 0.031g of the M16A1. The panel inserted to the new demining suit has protection rate of 100% within the distance of 1m and sample II has protection rate of 100% only beyond the distance of 5m. The test showed that the protection rate on the protective suit of the existing garment was comparatively high, however, the protection rate of the sleeve part was very low. The new demining suit through the research demand some complementary measures to lower the temperatures in ear, average skin temperatures, and the temperatures-humidity inside the clothing for summer climate condition, It showed that 30 minutes of rest on the clothing was difficult to go back to the original condition. But in winter climate condition, there was no problem in the temperature, humidity, and comfort to go back to the original condition during the rest and was better in warmth.

  • PDF

A Study on the Egress distance of Semiconductor factory (반도체공장의 피난거리 연구)

  • Lee, Yong-Jae;Lee, Kung-Koo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.189-194
    • /
    • 2008
  • Augmentation of the high-technology industry semiconductor factories, to acquire productivity and competitive power, is an international tendency. This situation is demanding for the functional counteractions. This study is regarding egress distance pertaining to installation of direct stairs. First, analyze situations and danger characteristics of LCD Factories. Second, through investigations and analysis of both domestic and foreign Egress Distance Code, propose rational Egress Distance Code pertaining to installation of direct stairs.

  • PDF

A Study on the Operational Characteristic of Distance Relay According to Power System Condition (계통조건에 의한 거리계전기의 응동특성에 관한 연구)

  • Jung, Chang-Ho;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.290-293
    • /
    • 2001
  • This paper presents the reach accuracy of a distance relay for protection of transmission line according to power system conditions. The apparent impedance of distance relay is considerably affected by source impedance, load current, power factor, fault point and resistance etc. For protective coordination on the variables power system parameters, trip characteristics of distance relay at sending and receiving terminal are discussed.

  • PDF

Compatibility between ISM Equipment and WiBro Service at 2.3 GHz band (2.3 GHz 대역의 ISM 기기와 WiBro 서비스의 양립성 분석)

  • Shim, Yong-Sup;Lee, Il-Kyoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.101-105
    • /
    • 2011
  • This paper calculates protection distance to protect WiBro service from ISM(Industrial Scientific Medical) equipment which is used in the same frequency with WiBro. We analyze with a scenario that WiBro receiver is closed to ISM equipment which has interfering power of CISPR(International Special Committee on Radio Interference) 11 limit. As a result, the protection distance of 14 m was calculated by using MCL (Minimum Coupling Loss) for the worst case. And, the protection distance of 10 m was calculated to meet 5 % interference probability below by using MC(Monte Carlo) for statistic analysis in case of a interferer.