• Title/Summary/Keyword: prosthesis and implants

Search Result 389, Processing Time 0.02 seconds

Fixed prosthesis restoration in edentulous patient fully implanted without considering definitive prosthesis: A case report (최종 보철물에 대한 고려 없이 전악 임플란트 식립된 환자의 고정성 보철 수복 증례)

  • Chun, Young-Hoon;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.427-435
    • /
    • 2017
  • The most important factor in the treatment of fully edentulous patients using implants is the shape of the definitive prosthesis. After the shape of the definitive prosthesis is determined, residual bone analysis and selection of the implant type, number and position should be followed. In this case, for restoration of an edentulous patient fully implanted (except the maxillary right lateral incisor) without considering definitive prosthesis, facial esthetics and possibility of fixed type prosthesis were evaluated using complete denture. It was determined that the fixed type prosthesis was possible. Implants that could not be used for the definitive prosthesis were excluded from the treatment plan and fixed type provisional restorations were fabricated. After four months of provisional restorations, the patient showed stable occlusion and esthetic satisfaction. Definitive prosthesis was made of zirconia using CAD/CAM (computer aided design and computer aided manufacturing). The results were satisfactory during the 3 months of follow-up period after termination of treatment.

The effects of local factors on the survival of dental implants: A 19 year retrospective study (임플란트의 생존율에 영향을 미치는 국소적 인자에 대한 19년간의 후향적 연구)

  • Kim, Sung-Hoi;Kim, Sun-Jai;Lee, Keun-Woo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.28-40
    • /
    • 2010
  • Purpose: The aim of this retrospective study was to provide long-term data about the correlation between multifactorial local factors and the survival of implants. Material and methods: During 19 years (1991 to 2009), 2796 implants were placed in 879 patients. From dental charts and radiographs, the following data were collected: patient's age at implant placement, gender, implant system, surface, length, diameter, location of implant placement, bone quality, primary stability, type of prosthesis. The correlations between these data and implant survival were analyzed. Statistical analysis was performed using Kaplan-Meier survival analysis, Chi-square test, odds ratio. Results: 1. Among the 2796 implants, 150 implants failed that resulted in a cumulative survival rate of 94.64%. The cumulative survival rate of smooth surface implants (91.76%) was lower than rough surface implants (96.02%). 2. Anatomic location, implant surface, diameter of smooth surface implant, primary stability, type of prosthesis, patient's age and gender were significantly associated with implant survival (P < .05). 3. No significant difference in implant survival was found in relation to the following factors: implant length, bone quality, diameter of rough surface implants and type of rough surface according to implant manufacturer (P < .05). Conclusions: Local factors such as anatomic location, implant surface, diameter of smooth surface implant, primary stability and type of prosthesis have a significant effect on implant survival.

Clinical Study on the Efficacy of the Autogenous Tooth Bone Graft Material (AutoBT) (자가치아 뼈 이식재의 유용성에 관한 임상적 연구)

  • Han, Min Woo;Lee, Jeong Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.4
    • /
    • pp.221-226
    • /
    • 2013
  • Purpose: This study is to evaluate the efficacy of the autogenous tooth bone graft material, clinically and radiologically, as related to implant installation. Methods: In oral and maxillofacial surgery department of Ajou University Hospital, guided bone regeneration (GBR), implant placement combined with GBR, sinus graft, implant placement combined with sinus graft, and defect filling were performed in 46 patients, using autogenous tooth bone. Among these, 66 implants were inserted with autogenous tooth bone. Implant stability quotient (ISQ) was measured by Osstell Mentor (Integration Diagnostics, Goteborg, Sweden) on 39 implants on the operation date and 4 months later, and on 21 implants 9months on the average at the final setting of restoration. Twenty-eight implants with GBR and sinus graft (GBR group: n=14, sinus graft group: n=14) were evaluated radiologically to measure the resorption of grafted autogenous tooth bone after loading. Results: The average initial stabilization of the installed implants was 67 ISQ, and the average secondary stabilization at 4 months later was 76. The average bone loss of GBR group as measured 8.0 months after application of prosthesis loading was 0.29 mm and the average bone loss of the sinus graft group as measured 7.6 months after application of prosthesis loading was 0.66 mm, respectively. In the histological assessment, formation of the new bone and continuous trabecular bone pattern was identified around autogenous tooth bone. Conclusion: Based on these results, we concluded that autogenous tooth bone is an excellent bone graft material that can substitute the autogenous bone.

Three-dimensional finite element analysis on stress distribution of the mandibular implant-supported cantilever prostheses depending on the designs (임플란트 지지 하악 캔틸레버 보철물의 디자인에 따른 저작압 분산에 관한 삼차원 유한요소 분석)

  • Ban, Jae-Hyurk;Shin, Sang-Wan;Kim, Sun-Jong;Lee, Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.70-81
    • /
    • 2009
  • Statement of problem: The position and length of cantilever influence on the stress distribution of implants, superstructure and bone. In edentulous mandible, implant-supported cantilever prostheses that based 4 or 6 implants between mental foramens has been attempted. Excessive bite force loaded at cantilever prosthesis causes bone resorption and breakage of superstructure prosthesis around posterior implants. To complement the cantilever length of conventional prosthesis, In 1992, (McCartney) introduced "cantilever-rest-implant" and Malo reported "All-on-Four" in 2003. Purpose: Analyze and compare the stress distribution of conventional cantilever prostheses with rest implant and All-on-$Four^{TM}$ implant prostheses. Material and method: The external loads(300 N vertically, 75 N horizontally) are applied to first molar area. The stress value, stress distribution and aspect of stress dispersion are analyzed by three-dimensional finite element analysis program, ANSYS ver. 10.0. Results: 1. The rest implant and "All-on-Four" implant system are superior to conventional cantilever prostheses to reduce stress on the bone and the superstructure around implants. 2. The rest implant was of the greatest advantage to stress distribution on bone, implant and superstructure. 3. With same number of implants, distally tilted implants are preferred to conventional cantilever prostheses for reducing the length of cantilever.

A 10-year retrospective study on the risk factors affecting the success rate of internal connection implants after prosthetic restoration (내부연결 임플란트의 보철 수복 후 성공률에 미치는 위험요소에 관한 10년간의 후향적 연구)

  • Seoin Lee;Min-Jeong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.113-124
    • /
    • 2023
  • Purpose. The purpose of this study is to help increase the success rate by analyzing the types and characteristics of implant prosthesis and the survival rate. Materials and methods. Among implants placed between 2011 and 2020 at Sanbon Dental Hospital, College of Dentistry, Wonkwang University, a case restored by a prosthetic surgeon was investigated for the characteristics and correlation of failure. The causes of failure were classified as failure of osseointegration, peri-implantitis, fixture fracture, abutment fracture, screw fracture, screw loosening, prosthesis fracture, and loss of prosthesis retention. Prosthetic method, cantilever presence, placement location, etc. were analyzed for their correlation with implant failure. Results analysis was derived through Chi-square test and Kaplan-Meier survival analysis using SPSS ver 25.0 (IBM, Chicago, IL, USA). Results. A total of 2587 implants were placed, of which 1141 implants were restored with Single Crown and 1446 implants with Fixed Partial Denture, and the cumulative survival rate was 88.1%. The success rate of SC was 86.2% (984) and the success rate of FPD was 89.6% (1295), showing statistically significant differences, among which factors that had significant differences were abutment fracture, screw fracture, and screw loosening (P < .05). Conclusion. As a result of the 10-year follow-up, more failures occurred due to biomechanical factors than biological factors. Further studies on the success of implants will be needed in the future.

Comparison of stress distribution in bone and implant-supported dental prosthesis with zirconia and titanium implants: a 3-dimensional finite element analysis (지르코니아 및 티타늄 임플란트를 사용한 지지골 및 임플란트 유지 수복물의 응력 분포 비교: 3차원 유한 요소 분석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.348-354
    • /
    • 2020
  • Purpose: Zirconia is differentiated from other ceramics because of its high resistance to corrosion and wear, excellent flexural strength (900~1400 MPa), and high hardness. Dental zirconia with proven mechanical/biological stability is suitable for the manufacture of implants. However, there are limited in vivo studies evaluating stress distribution in zirconia compared with that in titanium implants and studies analyzing finite elements. This study was conducted to evaluate the stress distribution of the supporting bone surrounding zirconia and titanium implants using the finite element analysis method. Methods: For finite element analysis, a single implant-supported restoration was designed. Using a universal analysis program, eight occlusal points were set in the direction of the occlusal long axis. The occlusal load was simulated at 700 N. Results: The zirconia implant (47.7 MPa) von Mises stress decreased by 5.3% in the upper cortical bone compared with the titanium implant (50.2 MPa) von Mises stress. Similarly, the zirconia implant (20.8 MPa) von Mises stress decreased by almost 4% in the cancellous bone compared with the titanium implant (21.7 MPa) von Mises stress. The principal stress in the cortical and cancellous bone exhibited a similar propensity to von Mises stress. Conclusion: In the supporting bone, the zirconia implant is able to reduce bone resorption caused by mechanically transferred stress. It is believed that the zirconia implant can be a potential substitute for the titanium implant by reinforcing aesthetic characteristics and improving stress distribution.

Pontic site development with an implant submergence technique for unaesthetic implant in the anterior maxilla (상악 전치부 임플란트의 비심미성 개선을 위한 임플란트 침수(submergence)를 동반한 치조제 증대술)

  • Song, Yujeong;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.289-295
    • /
    • 2020
  • Improving implant esthetics is very difficult, especially in cases where unaesthetic problems are related to implants in the maxillary anterior dentition. A 69-year old male patient was referred by a prosthodontist for periodic pus discharge and an unaesthetic implant prosthesis (maxillary right lateral incisor). The implant was placed too deeply and showed soft tissue volume deficiency and a long clinical crown. After a clinical and radiographic examination, implant submergence and alveolar ridge augmentation were performed to enhance the aesthetics instead of an explantation. The treatment plan was as follows: extraction the adjacent teeth with tooth mobility, secondary caries, and poor prognosis; placement an additional dental implant with hard and soft tissue grafting; fabrication a fixed bridge using implant abutments. A fixed esthetic prosthesis using implants was fabricated, and the patient was satisfied with the prosthesis. A ridge augmentation with implant submergence may be an alternative for solving the problems of unaesthetic implant restorations in the esthetic zone.

Recent Updates Regarding Outcomes and Complications of Reverse Total Shoulder Arthroplasty

  • Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.172-179
    • /
    • 2017
  • Indications of reverse total shoulder arthroplasty (RTSA) have been consistently extended by technical advancements in reverse arthroplasty prosthesis, continuous development of the implants, accumulated experiences and its successful treatment outcomes; accordingly, its use has rapidly increased. RTSA has been performed for a variety of indications, with variable outcomes depending on the initial diagnosis. However, controversial opinions still exist regarding the design of reverse arthroplasty prosthesis (medialized or lateralized design and the neck-shaft angle of the humeral prosthesis), suture of the subscapularis tendon, use of cement during placement of the humeral prosthesis, and surgical procedures; therefore, these should be investigated so that they can be better understood.

Implant complications in bruxism patients

  • Song, Ji-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.2
    • /
    • pp.149-150
    • /
    • 2021
  • Bruxism is defined as a parafunctional activity during sleep or while awake that includes locking and grinding of teeth and clenching. It generates excessive occlusal force that may lead to implant failure. Therefore, diagnosis of bruxism and providing specific protocols such as occlusal splint and/or injection of botulinum toxin before implant installation are important to prevent increases the risk of implant failure in bruxism patients.

A conversion to implant overdenture in failed fixed implant prosthesis of edentulous maxilla: A case report (상악 고정성 임플란트 보철물 실패 환자에서 임플란트 피개의치로 전환한 치료 증례)

  • Kim, Joon-Soo;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.393-400
    • /
    • 2016
  • Fixed implant prosthesis and removable implant overdenture are the main treatment options for treating edentulous maxilla with implants. If clinicians select one of the treatment options without accurate diagnosis and evaluation, this may lead to unfavorable treatment result and one would not be able to guarantee successful long term prognosis. In this case, 69 year-old female presented with failed fixed implant prosthesis that was treated in private dental clinic. Since the patient did not want additional insertion of implants and considering factors such as oral hygiene maintenance, splinting effect, and esthetics, the patient was treated with removable implant bar type overdenture using pre-existing implants. The clinical results were satisfactory in the aspect of esthetics and masticatory function, oral hygiene maintenance.