• Title/Summary/Keyword: prosthesis and implants

Search Result 391, Processing Time 0.019 seconds

Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method

  • Tiossi, Rodrigo;Falcao-Filho, Hilmo Barreto Leite;De Aguiar, Fabio Afranio Junior;Rodrigues, Renata Cristina Silveira;De Mattos, Maria da Gloria Chiarello;Ribeiro, Ricardo Faria
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.89-92
    • /
    • 2012
  • PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C ($6.43{\pm}3.24{\mu}m$) when compared to Groups A ($16.50{\pm}7.55{\mu}m$) and B ($16.27{\pm}1.71{\mu}m$) ($P$ <.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, $58.66{\pm}14.30{\mu}m$; Group B, $39.48{\pm}12.03{\mu}m$; Group C, $23.13{\pm}8.24{\mu}m$) ($P$ <.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks.

Esthetic restoration in continuous maxillary anterior area using immediate implant placement: A case report (임플란트 즉시 식립에 의한 연속된 상악 전치부의 심미적 수복 증례)

  • Lee, Ye Chan;Shim, Jun Sung;Lee, Jae Hoon;Lee, Keun Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.403-409
    • /
    • 2017
  • In the case of an extraction in the maxillary anterior region, immediate placement of implant-supported fixed prosthesis can be considered as a treatment option. Fewer surgical operations, reduced treatment time, and optimal availability of existing bone are obvious advantages of the method; however, when applied in the continuous maxillary anterior region, inter-implant distance must be carefully considered, as well as accurate diagnosis and treatment planning for predictable outcome. In this case report, immediate placement of two implants in the continuous maxillary anterior along with bone graft following the extraction of root rests, and the restoration of provisional and implant-supported fixed prosthesis on a 63-year-old patient had resulted in both esthetically and functionally satisfactory clinical outcomes.

Detachable zirconia prosthesis using Milled bar and ADD-TOC attachment in partial edentulous mandible: A case report (하악 부분 무치악 환자에서 Milled-bar와 ADD-TOC 부착 장치를 이용한 탈착 가능한 지르코니아 보철물 수복 증례)

  • Min-Sung Sohn;Jung-Bo Huh
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.90-99
    • /
    • 2023
  • Implant overdentures are widely used as a treatment method to restore oral function in completely edentulous or partially edentulous patients with severe bone resorption. Using a milled bar, it is mechanically advantageous as the implant fixtures are splinted. Applying additional attachments to the bar has the advantage of dispersing the stress applied to the implant. In this case, a patient who used implant overdentures using 4 implants wanted to fabricate a new prosthesis due to repeated fractures of the denture and weakened retention. Milled bar with ADD-TOC attachment and zirconia prosthesis were fabricated by CAD-CAM method and mechanically and aesthetically satisfactory results were obtained.

Minimal invasive horizontal ridge augmentation using subperiosteal tunneling technique

  • Kim, Hyun-Suk;Kim, Young-Kyun;Yun, Pil-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.41.1-41.6
    • /
    • 2016
  • Background: The goal of this study was to retrospectively evaluate the prognosis of minimal invasive horizontal ridge augmentation (MIHRA) technique using small incision and subperiosteal tunneling technique. Methods: This study targeted 25 partially edentulous patients (10 males and 15 females, mean age $48.8{\pm19.7years$) who needed bone graft for installation of the implants due to alveolar bone deficiency. The patients took the radiographic exam, panoramic and periapical view at first visit, and had implant fixture installation surgery. All patients received immediate or delayed implant surgery with bone graft using U-shaped incision and tunneling technique. After an average of 2.8 months, the prosthesis was connected and functioned. The clinical prognosis was recorded by observation of the peri-implant tissue at every visit. A year after restoration, the crestal bone loss around the implant was measured by taking the follow-up radiographs. One patient took 3D-CT before bone graft, after bone graft, and 2 years after restoration to compare and analyze change of alveolar bone width. Results: This study included 25 patients and 39 implants. Thirty eight implants (97.4 %) survived. As for postoperative complications, five patients showed minor infection symptoms, like swelling and tenderness after bone graft. The other one had buccal fenestration, and secondary bone graft was done by the same technique. No complications related with bone graft were found except in these patients. The mean crestal bone loss around the implants was 0.03 mm 1 year after restoration, and this was an adequate clinical prognosis. A patient took 3D-CT after bone graft, and the width of alveolar bone increased 4.32 mm added to 4.6 mm of former alveolar bone width. Two years after bone graft, the width of alveolar bone was 8.13 mm, and this suggested that the resorption rate of bone graft material was 18.29 % during 2 years. Conclusions: The bone graft material retained within a pouch formed using U-shaped incision and tunneling technique resulted with a few complications, and the prognosis of the implants placed above the alveolar bone was adequate.

Free gingival graft in combination with apically positioned flap for establishment of keratinized gingiva around the implants: Report of two cases (근단변위판막술과 함께 유리치은이식술을 사용하여 임플란트 주변 각화치은을 증대시킨 2건의 증례 보고)

  • Baek, Won-Sun;Cha, Jae Kook;Lee, Jae-Hong;Lee, Jung-Seok;Jung, Ui-Won
    • The Journal of the Korean dental association
    • /
    • v.54 no.4
    • /
    • pp.296-305
    • /
    • 2016
  • Narrow zone of attached gingiva and shallow vestibule around the implants might contribute to difficulty of cleasing, periimplant mucositis caused by incomplete cleansing and further peri-implantitis. The aim of this case report is to present modification of soft tissue biotype around the implants by free gingival grafts according to timing of surgical intervention and shape of free gingiva. A 44 year-old male patient had a missing area on lower right second molar area with 1 to 2 mm of narrow attached gingiva zone and wanted to be treated by implant placement. In radiographic analysis, there was enough alveolar bone to install an implant, free gingiva from hard palate was grafted following implant placement using double layer flap. The width of attached gingival was increased to 4 to 5mm and well maintained during 5 months of follow up. A 69 year-old female patient also had a missing area on lower right first and second molar area with 1 to 2 mm narrow attached gingiva. Since she had systematically angina pectoris and dental phobia, minimal invasive free gingival graft after implants placement was planned. After 2 months of implant surgery, free gingival graft surgery was performed with healing abutments connection. The grafted gingiva was composed of two strip shaped free gingiva, and they were immobilized by periodontal pack. The width of attached gingival was increased to 4 to 5mm and well maintained during 10 months of follow up. With prosthesis delivery, the patients recovered ideal periodontal environment around implants and masticatory function. In conclusion, periodontal health and masticatory function could be achieved through implant placement and free gingival graft.

  • PDF

Multilateral analysis of $Renova^{(R)}$ implant placement and its Survival rate ($Renova^{(R)}$ 임플란트 식립 후 단기간의 생존율에 대한 다각적 분석)

  • Yang, Jin-Hyuk;Kim, Sung-Tae;Jung, Ui-Won;Nam, Woong;Jung, Young-Soo;Shim, June-Sung;Moon, Hong-Seok;Lee, Keun-Woo;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.413-428
    • /
    • 2008
  • Purpose: Given the predictability of dental implant procedure from the studies of successful osseointegration, implant dentistry is often the treatment of choice to replace missing teeth in edentulous patient instead of the fixed prosthesis or removable denture. The $Renova^{(R)}$ dental implant has a RBM(Resorbable Blast Media) surface, internal hex prosthetic connection and a tapered design. At this study gives the analysis of the implant and the short term survival rate of the implant. Material and Methods: In this study, a multilateral analysis was performed on the subjects undergoing placement with $Renova^{(R)}$ implant between August 2006 and February 2008 in Yonsei University dental hospital. 96 implants were placed in 56 patients and they were surveyed for cumulative survival rate. Among them 78 implants in 44 patients were surveyed for the rest analyses. Result: 1. The cumulative survival rate was 96.88% of 96 implants in 56 patients. 2. The mean marginal bone loss was 0.803mm and the marginal bone loss in augmentation group has higher value than the marginal bone loss in non augmentation group. 3. The health scale for the implants were 87% in success group, 9% in satisfactory survival group, 1% in compromised survival group, and 3% in failure group. 4. Two implants placed in poor bone posterior area by 2-stage failed during prosthetic procedure. Conclusion: $Renova^{(R)}$ dental implant showed high cumulative survival rate in installation on partial edentulous ridge and could be a predictable implant system.

Clinical and radiographic evaluation of $Neoplan^{(R)}$ implant with a sandblasted and acid-etched surface and external connection (SLA 표면 처리 및 외측 연결형의 국산 임플랜트에 대한 임상적, 방사선학적 평가)

  • An, Hee-Suk;Moon, Hong-Suk;Shim, Jun-Sung;Cho, Kyu-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.125-136
    • /
    • 2008
  • Statement of problem: Since the concept of osseointegration in dental implants was introduced by $Br{{\aa}}nemark$ et al, high long-term success rates have been achieved. Though the use of dental implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. Purpose: The aim of this retrospective study was to provide long-term data on the $Neoplan^{(R)}$ implant, which features a sandblasted and acid-etched surface and external connection. Material and methods: 96 $Neoplan^{(R)}$ implants placed in 25 patients in Yonsei University Hospital were examined to determine the effect of the factors on marginal bone loss, through clinical and radiographic results during 18 to 57 month period. Results: 1. Out of a total of 96 implants placed in 25 patients, two fixtures were lost, resulting in 97.9% of cumulative survival rate. 2. Throughout the study period, the survival rates were 96.8% in the maxilla and 98.5% in the mandible. The survival rates were 97.6% in the posterior regions and 100% in the anterior regions. 3. The mean bone loss for the first year after prosthesis placement and the mean annual bone loss after the first year for men were significantly higher than that of women (P<0.05). 4. The group of partial edentulism with no posterior teeth distal to the implant prosthesis showed significantly more bone loss compared to the group of partial edentulism with presence of posterior teeth distal to the implant prosthesis in terms of mean bone loss for the first year and after the first year (P<0.05). 5. The mean annual bone loss after the first year was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. No significant difference in marginal bone loss was found in the following factors: jaws, type of prostheses, type of opposing dentition, and submerged /non-submerged implants (P<0.05). Conclusion: On the basis of these results, the factors influencing marginal bone loss were gender, type of edentulism, and location in the arch, while the factors such as arch, type of prostheses, type of opposing dentition, submerged / non- submerged implants had no significant effect on bone loss. In the present study, the cumulative survival rate of the $Neoplan^{(R)}$ implant with a sandblasted and acid-etched surface was 97.9% up to a maximum 57-month period. Further long-term investigations for this type of implant system and evaluation of other various domestic implant systems are needed in future studies.

Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias

  • Park, Kyung-Soon;Al Awamleh, Abdel Ghani Ibrahim;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.73-78
    • /
    • 2018
  • PURPOSE. The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti implant placements. MATERIALS AND METHODS. Twenty modSLA and 20 LE implants were installed on the left and right tibias of 20 adult rabbits. RTQs were measured after 7 and 10 days in 10 rabbits each. Scanning electron microscope (SEM) photographs of the two implants were observed by using Quanta FEG 650 from the FEI company (Hillsboro, OR, USA). Analyses of surface elements and components were conducted using energy dispersive spectroscopy (EDS, Horiba, Kyoto, Japan). RESULTS. The mean RTQs were $12.29{\pm}0.830$ and $12.19{\pm}0.713$ Ncm after 7 days (P=.928) and $16.47{\pm}1.324$ and $16.17{\pm}1.165$ Ncm after 10 days (P=.867) for LE and modSLA, respectively, indicating no significant inter-group differences. Pore sizes in the LE were $40{\mu}m$ and consisted of numerous small pores, whereas pore sizes in the modSLA were $5{\mu}m$. In the EDS analysis, Ti, O, and C were the only three elements found in the LE surfaces. Na, Ca, Cl, and K were also observed in modSLA, in addition to Ti, O, and C. CONCLUSION. The implants showed no significant difference in biomechanical bond strength to bone in early-stage osseointegration. LE implant can be considered an excellent surface treatment method in addition to the modSLA implant and can be applied to the early loading of the prosthesis clinically.

Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up

  • Alrabiah, Mohammed;Deeb, Modhi Al;Alsahhaf, Abdulaziz;AlFawaz, Yasser F.;Al-Aali, Khulud Abdulrahman;Vohra, Fahim;Abduljabbar, Tariq
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.2
    • /
    • pp.97-105
    • /
    • 2020
  • Purpose: The present retrospective clinical study aimed to evaluate and compare the clinical and radiographic parameters, complications, and satisfaction in patients who received fixed prostheses supported by narrow-diameter implants (NDIs) in the anterior and posterior jaw. Methods: Patients aged ≥30 years who had NDI-supported fixed prostheses in the anterior or posterior region of either jaw for at least 2 years were included. Complications such as chipping of the crown; loosening or fracture of the screw, crown abutment, or implant; and loss of retention were recorded. Clinical peri-implant outcomes and crestal bone loss (CBL) were measured. A questionnaire was used to record responses regarding the aesthetics and function of the fixed restorations. Analysis of variance was used to assess the significance of between-group mean comparisons. The log-rank test was performed to analyze the influence of location and prosthesis type on technical complications. Results: Seventy-one patients (mean age: 39.6 years) provided informed consent with a mean follow-up duration of 53 months. Only bleeding on probing showed a statistically significant difference between NDIs in the anterior and posterior regions. The complication rate for NDIs in the posterior region was significantly higher than that for NDIs in the anterior region (P=0.041). For NDIs, CBL was significantly higher around splinted crowns than single crowns (P=0.022). Overall mean patient satisfaction was 10.34±3.65 on a visual analogue scale. Conclusions: NDIs in the anterior and posterior jaws functioned equally well in terms of periimplant soft and hard tissue health and offered acceptable patient satisfaction and reasonable complication rates.

Silicone Implant-Based Paranasal Augmentation for Mild Midface Concavity

  • Kim, Joo Hyun;Jung, Min Su;Lee, Byeong Ho;Jeong, Hii Sun;Suh, In Suck;Ahn, Duk Kyun
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.1
    • /
    • pp.20-24
    • /
    • 2016
  • Background: Midface concavity is a relatively common facial feature in East Asian populations. Paranasal augmentation is becoming an increasingly popular procedure for patients with mild concavity and normal occlusion. In this study, we evaluate clinical outcomes following a series of paranasal augmentation. Methods: A retrospective review was performed for patients with Class I occlusion who had undergone bilateral paranasal augmentation using custom-made silicone implants, between October 2005 and September 2013. Patient charts were reviewed for demographic information, concomitant operations, and postoperative complications. Preoperative and postoperative (1-month) photographs were used to evaluate operative outcome. Results: The review identified a total of 93 patients meeting study criteria. Overall, aesthetic outcomes were satisfactory. Five-millimeter thick silicone implant was used in 81 cases, and the mean augmentation was 4.26 mm for this thickness. Among the 93 patients, 2 patients required immediate implant removal due to discomfort. An additional 3 patients experienced implant migration without any extrusion. Nine patients complained of transient paresthesia, which had resolved by 2 weeks. There were no cases of hematoma or infection. All patients reported improvement in their lateral profile and were pleased at follow-up. Complications that arose postoperatively included 9 cases of numbness in the upper lip and 3 cases of implant migration. All cases yielded satisfactory results without persisting complications. Sensations were fully restored postoperatively after 1 to 2 weeks. Conclusion: Paranasal augmentation with custom-made silicone implants is a simple, safe, and inexpensive method that can readily improve the lateral profile of a patient with normal occlusion. When combined with other aesthetic procedures, paranasal augmentation can synergistically improve outcome and lead to greater patient satisfaction.