• Title/Summary/Keyword: prosthesis and implants

Search Result 389, Processing Time 0.024 seconds

Subjective Symptoms of Peri-Implantitis and Satisfaction according to Prosthesis Methods (임플란트 보철방식에 따른 임플란트 주위염 자각증상 및 만족도)

  • Cha, Ji-Ae;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.17 no.2
    • /
    • pp.175-182
    • /
    • 2017
  • From March 1, 2016 to August 31, 2016, 375 dental implant patients between the ages of 30 and 70 years to evaluate their subjective symptoms and satisfaction according to prosthesis methods. The collected data were analyzed using the chi-square distribution test, t-test, one-way analysis of variance, and multiple logistic regression. Of the patients with subjective symptoms of peri-implantitis, 40.5% reported food impaction, 49.1% reported bleeding, 61.1% reported pain, 61.9% reported halitosis, and the overall satisfaction level with the implants was 3.95 points. In the prosthesis methods, implant-teeth connective group showed the lowest level of the food impaction (21.3%), the pain (35.5%), and the halitosis (36.6%) (p<0.001), and the lowest bleeding was the implant single (33.8%) (p<0.05). Patient satisfaction was higher in the implant-teeth connective group (4.06 points) and the group without bone grafting (4.03 points) (p<0.01). Factor analysis showed that implant satisfaction was 0.43 times lower in the single implant group and 0.44 times lower in the implant-implant connective group than in the implant-teeth connective group. As a result of the study, it is expected that the method of extending the life of adjacent teeth and restoring the function of the tooth defect region is an implant-teeth connection method, so that it can be utilized positively through various clinical studies.

Repairment of abutment and abutment screw fracture in implant prosthesis: A case report (지대주 혹은 지대주 나사 파절이 발생한 임플란트 보철물에서 효과적인 수리 방법)

  • Kim, Jae Hoon;Yoo, Jin Joo;Kim, Man Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.37-41
    • /
    • 2019
  • Dental implants are an effective and predictable treatment for restoration of missing teeth. However, as the use of implants increases, complications are also increasing. The mechanical complications are not only highly frequent, but also increasing as life span of an implant increases, thus, solutions should be prepared. In this report, we will present a case dealing with abutment fracture and abutment screw fracture which are the most common mechanical complication of the implant, focusing on preserving and reusing existing components by reconstructing only the damaged parts.

Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results

  • Park, Han;Moon, Ik-Sang;Chung, Chooryung;Shin, Su-Jung;Huh, Jong-Ki;Yun, Jeong-Ho;Lee, Dong-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.6
    • /
    • pp.422-432
    • /
    • 2021
  • Purpose: The aim of this study was to compare straight and tapered implant designs in terms of marginal bone loss, the modified plaque index (mPI), and the modified bleeding index (mBI) for 5 years after functional loading. Methods: Twelve patients were recruited. Two types of implants were placed adjacent to each other: 1 straight implant and 1 tapered implant. Marginal bone loss, mPI, and mBI were measured every year for 5 years after loading. Results: The straight implants showed 0.2±0.4 mm of marginal bone loss at 5 years after loading, while the tapered implants showed 0.2±0.3 mm of marginal bone loss; this difference was not statistically significant (P=0.833). Our analysis also showed no statistically significant differences in mPI (straight implants: 0.3±0.3 vs. tapered implants: 0.2±0.3; P=0.414) or in mBI (straight implants: 0.3±0.4 vs. tapered implants: 0.2±0.3; P=0.317) at 5 years after prosthesis delivery. Conclusions: Straight and tapered implants showed no significant differences with respect to marginal bone loss, mPI, and mBI for 5 years after loading.

Implant-assisted full denture using digital guide: a case report (무치악 환자에서 디지털 가이드를 이용한 임플란트 수복증례)

  • Kim, Wook Tae
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.202-209
    • /
    • 2021
  • By classifying temporary denture production for surgical guides, digital guide-based surgery, and final prosthesis production, the problems of each process were assessed in advance and the factors that could be improved were confirmed in this study. The manufacturing process of fusion dental prosthesis uses virtual programs and computed tomography images to manufacture devices using the latest technologies of computer-aided design/computer-aided manufacturing and three-dimensional printing, which enables implants to be placed in the desired location in advance. Moreover, implant placement is not dependent on the skill and condition of the dentist, and because it uses a computer system, it can always be performed at a constant and optimal position. This can reduce the remanufacturing rate compared with the general method, shorten the treatment period, and eliminate patient discomfort. Unlike the traditional method of using impression materials and plaster models, digital fusion dental prostheses would be evaluated as a technology for producing prosthesis through professional design technology and communication.

Rehabilitation of a patient by converting poorly maintained fixed implant prosthesis into implant overdenture: a case report (기존 임플란트 보철물의 불량한 유지관리를 개선하기 위해 임플란트 피개의치로의 상부 보철물 전환 증례)

  • Kim, Yeong-Kyu;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.127-134
    • /
    • 2022
  • Among many contributing factors of implant failure, excessive loading and inflammation contribute mainly to increasing implant failure rate. Especially, poor oral hygiene around implants is one of the most common reasons for implant failure. When implant prosthesis fails to function, the clinician should re-diagnose and plan treatment using the remaining implants. Additional implantation may be needed to make a new type of prosthesis or either implant-assisted RPD and implant overdenture treatment may be performed using the remaining implants. In this article, a patient whose fixed implant prosthesis in the maxilla had failed of poor oral hygiene maintenance was reported to be recovered with removable implant overdenture by using remaining implant abutments and a milled bar with additional retentive elements. Through this treatment, the clinical results were satisfactory in terms of esthetics, masticatory function recovery and oral hygiene management.

Combination restorative restorations using conventional partial denture and CAD / CAM (Conventional partial denture와 CAD/CAM을 이용한 combination 보철물 수복)

  • Choi, Seok-yeun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.52-63
    • /
    • 2017
  • When you need to make an upper and lower full-mouth prosthesis, you should design a prosthesis by making an accurate diagnosis and planning well. In particular, in patients with occlusal plane collapsed and misplaced occlusal plane, the patient should be restored to the previous occlusal height and the correct occlusal plane should be created. In addition, appropriate materials should be used to ensure that the patient is able to chew the food well and not force it. When the implants are placed in an inappropriate position, the design of the prosthesis is determined by considering the relationship with the prosthesis and occlusion. Design should be made for the cleanliness around the implant.

The Effects of Screw Retained Prosthesis Misfit & Cantilever on Stress Distribution in Bone Around the Implant (나사유지형 임플란트 고정성 보철물의 적합도와 캔틸레버가 지지골조직의 응력분산에 미치는 영향)

  • Lee, Jae-In;Kim, Tae-Young;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.224-235
    • /
    • 2013
  • A passively fitting prosthesis is an essential prerequisite to attain long-lasting success and maintenance of osseointegration. However, true "passive fit" can not be achieved with the present implant-supported prosthesis fabrication protocol. Many clinical situations are suitably treated with cantilevered implant-supported fixed restorations. The purpose of this study was to compare the stress distribution pattern and magnitude in supporting tissues around ITI implants with cantilevered, implant-supported, screw-retained fixed prosthesis according to the fitness of superstructures. Photoelastic model was made with PL-2 resin (Measurements, Raleigh, USA) and three ITI implants (${\phi}4.1{\times}10mm$) were placed in the mandibular posterior edentulous area distal to the canine. Anterior and posterior extended 4-unit cantilevered FPDs were made with different misfit in the superstructures. 4 types of prosthesis were made by placing a $100{\mu}m$ gap between the abutment and the crown on the second premolar and/or the first molar. Photoelastic stress analysis were carried out to measure the fringe order around the implant supporting structure under simulated loading conditions (30 lb).

Full mouth rehabilitation of fully edentulous patient using implant hybrid prosthesis (완전무치악 환자에서 임플란트 하이브리드보철물을 이용한 전악 수복 증례)

  • Park, Sang-Yong;Kim, Yoon-Young;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.228-233
    • /
    • 2015
  • Loss of teeth may not only imply impaired oral function and loss of alveolar bone but is also often accompanied by reduced self-confidence. This results in a larger problem with the fully edentulous patient. The patient introduced in this study showed multiple missing teeth and mobility of remaining teeth and wanted to have fixed dental prosthesis using implants. Remaining teeth were extracted because of periodontally bad prognosis. This article reports a satisfactory clinical and esthetic outcome of full mouth rehabilitation using implant hybrid prosthesis in fully edentulous patient.

Implant supported prosthetic rehabilitation of severely atrophic mandible with fixed detachable prosthesis (심하게 흡수된 하악골에서 fixed detachable prosthesis를 이용한 임플란트 지지 보철 수복증례)

  • Lee, Hak-Joo;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.180-186
    • /
    • 2017
  • Implant supported prostheses have improved the quality of lives of totally edentulous patients. However, there are some limitations on the number of implants related to the residual bone level or the economic concern and so on. In this situation, applying fixed detachable prosthesis with bilateral cantilevers can be considered. This clinical report describes implant supported prosthetic rehabilitation of a patient with severe bone resorption. The patient was satisfied and felt comfortable with upper complete denture and lower fixed detachable prosthesis.

Number of implants for mandibular implant overdentures: a systematic review

  • Lee, Jeong-Yol;Kim, Ha-Young;Shin, Sang-Wan;Bryant, S. Ross
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.204-209
    • /
    • 2012
  • PURPOSE. The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS. A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS. Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION. The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants.