• Title/Summary/Keyword: prostheses and Implants

Search Result 223, Processing Time 0.024 seconds

A COMPARISON OF THE MASTICATORY FUNCTION BETWEEN TWO DIFFERENT TYPES OF IMPLANT SUPPORTED PROSTHESES AND COMPLETE DENTURE FOR FULLY EDENTULOUS PATIENTS

  • Lee, Jae-Hoon;Kim, Woo-Hyun;Shin, Rie-Hye;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.591-601
    • /
    • 2008
  • STATEMENT OF PROBLEM: The improvement in oral function and comfort from the dental implant appears to depend on the particular type of implant support used with the denture. The number and positioning of implants have an influence on the force transfer and subsequent stress distribution around implants. Nevertheless, a quantitative comparison has not been made between the types of implant prosthesis used with different materials compared to conventional complete denture. PURPOSE: The objective of this study is to assess the masticatory performance, bite force and impact of two different type of implant supported prostheses on oral health-related quality of life compared to conventional complete denture with GOHAI, validated oral-specific health status measures, the sieving method, and the Prescale Dental System. MATERIAL AND METHODS: From the years 1999 to 2006, a total of 30 completely edentulous patients in a single arch were selected from the Yonsei University Dental Hospital, Department of Prosthodontics and Implant Clinic in Seoul, S. Korea. Patients were divided into 3 groups of 10 each. Group HR was restored with fixed-detachable hybrid prostheses with resin teeth. Group FP had fixed dentures with porcelain teeth while Group CD had a complete denture. The masticatory performance was compared between 3 groups. RESULTS: The results showed a significant improvement in oral health-related quality of life with dental implants compared to a conventional denture in GOHAI comparison. Overall, implant prostheses showed a higher masticatory performance ($S_{50}$) and maximum bite force compared with conventional dentures (P < .05) but no differences between different implant supported prostheses (P > .05). CONCLUSION: Within the limitation of this study, the numbers of implant and material of implant prostheses does not appear to impact patient satisfaction, masticatory performance or bite force.

Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study

  • Lee, Ki-Young;Shin, Kyung Su;Jung, Ji-Hye;Cho, Hye-Won;Kwon, Kyung-Hwan;Kim, Yu-Lee
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.2
    • /
    • pp.133-142
    • /
    • 2020
  • Objectives: In this study, we determined the incidence and pattern of screw loosening in patients who received dental implants. Materials and Methods: Patients who received implants between January 2008 and October 2013 and completed their prosthetic rehabilitation were evaluated for the incidence, frequency, and onset of screw loosening using dental charts and radiographs. The association between each factor and screw loosening was analyzed using the chi-square test and a multivariate analysis with binary logistic regression models (P<0.05). Results: Total 1,928 implants were placed in 837 patients (448 males, 389 females), whose follow-up period after loading varied from 0.25 to 70 months (mean period, 31.5 months). Screw loosening occurred in 7.2% of implants. Most cases occurred less than six months after loading. Among those, 22.3% experienced recurrent screw loosening. Screw loosening was most common in the molar region (8.5%) and frequently associated with an implant diameter of ≥5 mm (14.2%). External implant-abutment connections (8.9%) and screw-retained implant prostheses (10.1%) showed higher incidence of problems than internal implant-abutment connections and cement-retained implants, respectively. Screw loosening was most common in implant prostheses with single crowns (14.0%). Conclusion: Within the limits of the current study, we conclude that the incidence of screw loosening differs significantly according to the position of implant placement, the type of implant and manufacturer, implant diameter, the type of implant-abutment connection, the type of retention in the implant prosthesis, and the type of implant prosthesis.

Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study

  • Mirac Berke Topcu, Ersoz;Emre, Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.346-359
    • /
    • 2022
  • PURPOSE. Four and six implant-supported fixed full-arch prostheses with various framework materials were assessed under different loading conditions. MATERIALS AND METHODS. In the edentulous maxilla, the implants were positioned in a configuration of four to six implant modalities. CoCr, Ti, ZrO2, and PEEK materials were used to produce the prosthetic structure. Using finite element stress analysis, the first molar was subjected to a 200 N axial and 45° oblique force. Stresses were measured on the bone, implants, abutment screw, abutment, and prosthetic screw. The Von Mises, maximum, and minimum principal stress values were calculated and compared. RESULTS. The maximum and minimum principal stresses in bone were determined as CoCr < ZrO2 < Ti < PEEK. The Von Mises stresses on the implant, implant screw, abutment, and prosthetic screws were determined as CoCr < ZrO2 < Ti < PEEK. The highest Von Mises stress was 9584.4 Mpa in PEEK material on the prosthetic screw under 4 implant-oblique loading. The highest maximum principal stress value in bone was found to be 120.89 Mpa, for PEEK in 4 implant-oblique loading. CONCLUSION. For four and six implant-supported structures, and depending on the loading condition, the system accumulated different stresses. The distribution of stress was reduced in materials with a high elastic modulus. When choosing materials for implant-supported fixed prostheses, it is essential to consider both the number of implants and the mechanical and physical attributes of the framework material.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MANDIBULAR CANTILEVERED PROSTHESIS SUPPORTED BY IMPLANTS (임프란트로 지지된 하악 켄티레버 보철물의 3차원 유한요소 분석)

  • Cho, Chul;Shin, Sang-Wan;Kwon, Jong-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.724-743
    • /
    • 2000
  • One of the biggest clinical problems of osseointegrated implant prosthesis is the excessive stress caused by bite forces which are transfered directly into the bone through the osseointegrated implant fixtures. So several biodynamic problems occur when there is an excessive fatigue stress. The factors of stress distribution are the number, kind, position, arrangement of the implants, and the distance between the implants, and the kind, quality of superstructure prosthesis and connection type between the rest implant and the superstructure. Recently, a distal short additional implant, socalled rest implant, is employed to reduced the stresses in conventional cantilevered prostheses. This study was undertaken to analyze the stresses transfered by osseointegrated implant cantilevered prostheses depending upon the number and the position of implants, the presence of rest implant, and the type of their connection. Three dimensional finite element analysis was attempted using ANSIS ver. 5.3 program under IBM INDIGO computer. The results were as follows : 1. The rest implant influenced on the pattern of stress distribution on the anterior area of the mandible and the superstructure. 2. In the group employing the rest implants, the fixed type of connection between the rest implant and the superstructure was more stable than the ball attachment type on the stress distribution. 3. In the group employing the ball attachment between the rest implant and the superstructure, the case with 4-implants(on canine, premolar) was little more stable than the case with 6-implants and the case with 4-implants(on incisor, premolar) on the stress distribution. 4. In the cantilevered group, the case with 4-implants(on incisor, premolar) and the case with 6-implants were more stable than the case with 4-implants(on canine, premolar) on the stress distribution. 5. In all of the group, the case with 6-implants and the fixed type of connection was the most stable and the case with 4-implants (on canine, premolar) was the most unstable on the stress distribution.

  • PDF

EFFECT OF CANTILEVER LENGTH AND LOAD ON STRESS DISTRIBUTION OF FIXED IMPLANT-SUPPORTED PROSTHESES (캔틸레버의 길이와 하중이 하악 임플랜트지지 고정성 보철물의 응력 분산에 미치는 영향)

  • Tae, Yen-Sup;Lee, Wha-Young;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.4
    • /
    • pp.615-643
    • /
    • 1998
  • The purpose of this study was to evaluate the effect of cantilever length, load, and implant number on the stress distribution of implant supported fixed prosthesis. In the replica of an edentulous human mandible, four or five implants were placed and spaced evenly between the mental foramina and symmetrical gold alloy cast superstructures with cantilever were fabricated. Strain gauges were placed in buccal and lingual side of implants. 9, 15, 21kg of loads at varying cantilever lengths were applied to the occlusal surface of fixed prostheses. The strains were recorded from each gauge and principal stresses were calculated The results were as follows : 1. Increasing the length of the cantilever increased the stresses on the bone supporting implants. and the ratio of increase became high as increasing the load. 2. In the model with four implants, the highest compressive stress was measured on lingual side of the first implants nearest loading point and the highest tensile stress was measured on buccal side of the second implants. 3. In the model with five implants, the highest compressive stress was measured on lingual side of the first implants nearest loading point. And the highest tensile stress was measured on buccal side of the second implants, and lingual side of the third implants. 4. There was no significant change of the magnitude of stress on the most distal imp]ant of non cantilevered side as increasing the cantilever length or load. 5. In general, the superstructure supported by five implants reduced the stress and was less affected by cantilever length compared to the support provided by four implants.

  • PDF

Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth (Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철)

  • Yoon, Hyung-In
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

A Study on the Adhesiveness between Polyurethane Sheet for Maxillofacial Prostheses and Autopolymerizing Acrylic Resin in Various Polymerization Methods (다양한 중합방법에 따른 악안면 보철용 폴리우레탄과 자가중합 레진 간의 결합력에 관한 연구)

  • Kim, Doo-Yeol;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.123-132
    • /
    • 2000
  • The field of maxillofacial prosthetics is concerned with the prosthetic reconstruction of missing head and neck tissue. Currently, facial prostheses are usually applied in cases of defects caused by the surgical removal of tumors or congenital defects. While silicone has been most widely used for the reconstruction of missing maxillofacial defects, it does not have ideal physical properties. Therefore, bonding a thin polyurethane sheet to silicone prostheses was recommended. In this case skin adhesives were used for the retention of maxillofacial prostheses. But retention of devices has always been problematic. The contributions of implants can be made to solve these problems. Implants have reduced the need for adhesive use, simplifying cleaning procedures and thus extending the life of the prostheses. For implant-retained prostheses, retentive matrix is necessary to hold attachments and/or magnets. The retentive matrix is usually fabricated with autopolymerizing acrylic resin or visible light- polymerized resin. The purpose of this study was to compare the adhesion-in-peel force of silicone adhesive to autopolymerizing acrylic resin and polyurethane sheet with two different surface textures : pumice polish only or retention groove, and three surface primers : Dow corning 1205 primer or Dow corning S-2260 primer or FactorII A-304 primer, and two polymerization methods : room temperature or dry heat oven. The t-peel bond strength of specimens was determined as described in ASTM Standard D1876-72. The results were statistically analyzed using the ANOVA test, multiple range test and t-test The results were as follows. 1. The t-peel bond strength of A-304 primer was the highest and statistically higher than that of S-2260(p<0.05). 2. The t-peel bond strength of specimens with retention groove was statistically higher than that of specimens polished with pumice(p<0.05). 3. The t-peel bond strength of specimens polymerized in dry heat oven was statistically higher than that of specimens in room temperature(p<0.01).

  • PDF

Finite element analysis of the femur fracture for a different total hip prosthesis (Charnley, Osteal, and Thompson)

  • Mohammed El Sallah Zagane;Moulgada Abdelmadjid;Murat Yaylaci;Sahli Abderahmen;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • v.88 no.6
    • /
    • pp.583-588
    • /
    • 2023
  • Total hip replacement is a crucial intervention for patients with fractured hips who face challenges in natural recovery. The design of durable prostheses requires a comprehensive understanding of the natural processes occurring in bone. This article focuses on static loading analysis, specifically during stumbling activity, aiming to enhance the longevity of prosthetic implants. Three distinct implants, Charnley, Osteal, and Thompson, were selected for a detailed study to determine the most appropriate model. The results revealed critical insights into the distribution of Von Mises stresses on the components of femoral arthroplasty, including the cement, implant, and cortical bone. Furthermore, the examination of shear stress within the cement emerged as a pivotal aspect for all three implants, playing a crucial role in evaluating the performance and durability of hip prostheses. The conclusions drawn from this study strongly suggest that the Thompson model stands out as the most suitable choice for hip joint implants.

Influence of implant mucosal thickness on early bone loss: a systematic review with meta-analysis

  • Di Gianfilippo, Riccardo;Valente, Nicola Alberto;Toti, Paolo;Wang, Hom-Lay;Barone, Antonio
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.4
    • /
    • pp.209-225
    • /
    • 2020
  • Purpose: Marginal bone loss (MBL) is an important clinical issue in implant therapy. One feature that has been cited as a contributing factor to this bone loss is peri-implant mucosal thickness. Therefore, in this report, we conducted a systematic review of the literature comparing bone remodeling around implants placed in areas with thick (≥2-mm) vs. thin (<2-mm) mucosa. Methods: A PICO question was defined. Manual and electronic searches were performed of the MEDLINE/PubMed and Cochrane Oral Health Group databases. The inclusion criteria were prospective studies that documented soft tissue thickness with direct intraoperative measurements and that included at least 1 year of follow-up. When possible, a meta-analysis was performed for both the overall and subgroup analyses. Results: Thirteen papers fulfilled the inclusion criteria. A meta-analysis of 7 randomized clinical trials was conducted. Significantly less bone loss was found around implants with thick mucosa than around those with thin mucosa (difference, -0.53 mm; P<0.0001). Subgroups were analyzed regarding the apico-coronal positioning, the use of platform-matched vs. platform-switched (PS) connections, and the use of cement-retained vs. screw-retained prostheses. In these analyses, thick mucosa was found to be associated with significantly less MBL than thin mucosa (P<0.0001). Among non-matching (PS) connections and screw-retained prostheses, bone levels were not affected by mucosal thickness. Conclusions: Soft tissue thickness was found to be correlated with MBL except in cases of PS connections used on implants with thin tissues and screw-retained prostheses. Mucosal thickness did not affect implant survival or the occurrence of biological or aesthetic complications.