• Title/Summary/Keyword: propylene/propane

Search Result 85, Processing Time 0.022 seconds

Extraction Property of Plasticizer in LPG High Pressure Rubber Hose (LPG용 고압고무호스에서 가소제 추출특성)

  • Kim, Young-Gu
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.2
    • /
    • pp.156-160
    • /
    • 2004
  • The extraction rates of plasticizer of LPG high pressure rubber are studied. Submerging solvents are composed of propane, n-butane, n-pentane, n-hexane, n-heptane, propylene, 1,3-butadiene, 1-pentene, 1-hexene, ethanethiol, t-butanethiol, dimethyl sulfide, methyl ethyl sulfide. The relationship between the extraction rate of plasticizer and the descriptors of submerging solvent by using multiple linear regression is as follows; PE(wt%) = 7.5193 - 0.58500Carbon${\sharp}$ + 2.3294DB + 2364SH, (N = 13, F = 24.135, R$^2$ = 0.8894, R$_{adj}^2$ = 0.8526, Variance = 7.588) Plasticizer is well extracted by LPG composed of the high vapour pressure and polarity compounds. The mass of extracted plasticizer becomes increasing in proportion to the contents of thiol sulfur compound and unsaturated hydrocarbon such as propylene and 1,3-butadiene in LPG. While the heavier hydrocarbons are, the less the quantities of plasticizer extracted from rubber are.

Comparative Research on the Carbon Dioxide Liquefaction Using Several Refrigerants (몇 가지 냉매를 사용한 이산화탄소 액화에 대한 비교 연구)

  • ILSU PARK;PHILSUNG HWANG;KICHEOL JUNG;JUNESHU ANH;JUNGHO CHO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.226-233
    • /
    • 2023
  • In this study, we compared the performance of several refrigeration cycles using different refrigerants and utilizing the cold heat of liquefied natural gas (LNG) for the liquefaction of carbon dioxide. The final conditions for the liquefied CO2 were set to -20℃ and 20 bar. The refrigerants used included R404a, ammonia, propane, and propylene using a vapor recompression refrigeration cycle. For the refrigeration cycle, the CO2 at room temperature and pressure was compressed in a two-stage compression process with an intermediate cooling stage using a refrigeration unit. To compare with the liquefaction process using refrigeration, we compressed the CO2 to 8 bar in a single compression stage and cooled it to around -50℃ using the cold heat of the LNG before liquefying it. Results showed that using ammonia as the refrigerant required the least amount of compressor power for the liquefaction process, and the heat transfer area of the evaporator was the smallest when using propylene as the refrigerant. Using the cold heat of LNG instead of refrigeration using R404a resulted in approximately 69% less energy consumption.

Conversion of Methanol to Hydrocarbons over Heteropoly Acids(I) (헤테로폴리산 촉매에 의한 탄화수소로의 메탄올 전환반응(I))

  • Hong, Seong-Soo;Lee, Ho-In
    • Applied Chemistry for Engineering
    • /
    • v.2 no.4
    • /
    • pp.363-371
    • /
    • 1991
  • The catalytic performance and availability of heteropoly compounds for the conversion of methanol to hydrocarbons have been studied. The effects of reaction conditions such as reaction temperature, methanol partial pressure and residence time and the effects of ion-exchange of the catalysts were examined for enhancing the yield of hydrocarbons and the selectivity of low olefins. Their acid strength depended on the kind of countercation, and the yield of hydrocarbons and the selectivity for propylene to propane were closely related to the electronegativity of the corresponding countercations. In contrast to the other heteropoly compounds, the ammonium salt showed a considerably high catalytic activity and a high selectivity for paraffins to low olefins.

  • PDF

Condensing Heat Transfer of Natural Refrigerants with Nanoparticles in Enhanced Tube (나노입자를 포함한 자연냉매의 마이크로 휜관 응축 열전달 특성)

  • Lee, H.S.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.19-25
    • /
    • 2008
  • This paper deals with the heat transfer and pressure drop characteristics of R-290 (Propane), R-600a (Iso-butane) and R-1270 (Propylene) as an environment friendly refrigerant and R-22 as a HCFC's refrigerant for condensing. The test section is a horizontal double pipe heat exchanger. Condensing heat transfer and pressure drop measurements were Peformed for 12.70 mm micro-fin tube and compared with the results in smooth tube. The local condensing heat transfer coefficients of hydrocarbon refrigerants were superior to those of R-22 and the maximum increasing rate of heat transfer coefficient was found in R-600a. The average condensing heat transfer coefficients in hydrocarbon refrigerants showed 20 to 28% higher values than those of R-22. Hydrocarbon refrigerants have a higher pressure drop than that of R-22 with respect to refrigerant qualify and mass flux. Also, the condensing heat transfer coefficient and pressure drop of working fluids in smooth and micro-fin tube were compared. The heat transfer enhancement factor (EF) between smooth and micro-fin tube varied from 2.2 to 2.6 in all experimental conditions.

  • PDF

Comparison of the Concentration of Ambient Volatile Organic Compounds at an Ulsan Industrial Site in 1997 and 1998 (울산 공단 대기에서 측정한 휘발성 유기화합물의 1997년과 1998년 결과 비교)

  • 나광삼;김용표;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.567-574
    • /
    • 1999
  • Volatile organic Compounds(VOC) were measured at an industrial site in Ulsan in 1997 and 1998. Twenty-four hour integrated ambient air samples were collected in 6 L SUMMA canisters during the periods of June 3 to 8, 1997 and June 12 to 17, 1998. The daily mean concentrations of the total $C_2-C_9$ VOC in 1998 were about one third of those in 1997. This decrease of VOC levels may be attributable to the measures to control the emissions of VOC and the decrease of the plant operation. The decrease in the concentrations of oxygenated hydrocarbons and alkenes, especially, contributed to the decrease of the total VOC concentrations in 1998. Lowever concentrations of alkenes compared to aromatics in 1998 were due to the decrease of ethylene and propylene. In the present study, methanol (12.0 ppb) was the most abundant species, followed by acetone (10.1 ppb), propane (6.0 ppb), and vinyl chloride (5.9 ppb). The total concentrations of hazardous air pollutants (HAPs) in 1998 were reduced compared to those in 1997. However, this decrease is due to the drastic decrease of the concentration of methanol. Except methanol, the concentrations of HAPs have not varied much. It is suspected that the VOC control strategy for the Ulsan industrial area has been successful for reducing the total VOC levels but might not be effective in reducing the concentrations of HAPs.

  • PDF

Changes in Facilitated Transport Behavior of Silver Polymer Electrolytes by UV Irradiation

  • Jongok Won;Yosang Yoon;Kang, Yong-Soo
    • Macromolecular Research
    • /
    • v.10 no.2
    • /
    • pp.80-84
    • /
    • 2002
  • Silver species other than the silver ion were formed by UV irradiation on polymer electrolyte membranes containing silver salts and their effect on complexation behavior between the silver and olefin was investigated through the separation performance of olefin/paraffin mixtures. The ideal propylene/propane separation factor reached 350 and the separation coefficient was ca.15 due to the high loading amount of silver ions into poly(2-ethyl-2-oxazoline) (POZ) without UV irradiation. On UV irradiation either in air or under nitrogen, the silver-POZ membranes became yellow-brown initially due to the formation of colloidal silver particles, and finally black and metal-like luster. Even when Ag$^{+}$ was converted, to some extent, to Ag$^{\circ}$ by UV irradiation in air at the early stage, the separation coefficient of olefin/paraffin mixtures was maintained. This suggests that silver species other than the silver ion is active for olefin carrier for facilitated transport. Meanwhile the steady decrease of the separation coefficient was observed in the silver/POZ membranes irradiated under $N_2$. It is suggested that the reduction of silver ions in POZ goes through a different photoreduction mechanism with UV irradiation depending on the environment.t.

Analysis of Gas Hydrocarbons by Gas-Liquid Partition Chromatography (Gas Chromatography 에 依한 까스炭化水素의 分析)

  • Chwa-Kyung Sung;Icksam Noh;Jung Yup Kim
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.128-132
    • /
    • 1963
  • A study has been made on the applicability of gas-liquid partition chromatography to the qualitative and quantitative analysis of complex mixture of gaseous hydrocarbons. While phthalate columns are widely used for this $purpose^9$, they separates neither saturated hydrocarbons from the unsaturated nor n-butane from isobutene or butene-1, therefore combined columns such as phthalate and dimethylsulfolane have been used for the perfect separation of gaseous hydrocarbons. It is shown by this study, however, that hydrocarbons having $C_1$ through $C_4$ can be separated with a 2-meters tetraethyleneglycol dimethylether column except ethane from ethylene, and trans-from cis-2-butene especially operated at $15^{\circ}C$$ using helium as the carrier gas. The column effluents were in order of methane, (ethane, ethylene), propane, propylene, isobutane, n-butane, isobutylene, butene-1, (trans-& cis-2-butene, isopentane), (butadiene-1, 3, n-pentane). Two kinds of liquified petroleum gases in market are analysed qualitatively and quantitatively. The results indicate that use of this 2-meters TEGDE column permits the separation and identification of all the commonly encountered aliphatic gaseous hydrocarbons.

  • PDF

Numerical Simulation of the Odor Spreading in a Factory (공장에서 퍼지는 냄새에 관한 수치계산적 연구)

  • Vincent, Lijo;Song, Eun-Hwa;Nam, Hyun-Kyu;Shin, Choon-Sik;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2540-2543
    • /
    • 2008
  • Liquid crystal displays (LCD's) are continuously coated with some chemicals in the clean room of a factory. Spreading of these chemicals is causing serious problems both in controlling clean room quality as well as to the workers inside the factory. It is required to alleviate or properly control the offensive odor which is mainly composed of propylene glycol mono ethyl acetate, novolak resin and photo active compound. The control strategy employed is to bleed the offensive odor gas out the clean room. A full scale 3D CFD model was created with anisotropic porous media, chemical species transport with no volumetric reaction, and thermal diffusion with propane gas (tracer gas) to simulate the odor spreading. A segregated implicit solver with standard k-$\varepsilon$ model is employed. The detailed CFD analysis made it possible to develop an effective method of ventilating the coater room and optimizing their capacities.

  • PDF

Effect of Valine on facilitated O1e1in Transport Membranes (올레핀 촉진수송 분리막의 성능향상을 위한 Valine의 효과)

  • Yong Soo Kang;Sang Wook Kang;Jong Hak Kim;Jongok Won;Kookheon Char
    • Membrane Journal
    • /
    • v.13 no.2
    • /
    • pp.125-129
    • /
    • 2003
  • A remarkable separation performance of olefin/paraffin mixtures has been observed through facilitated olefin transport membranes consisting of silver ions dissolved in polymer matrices. In this research, valine, an amino acid, was introduced in poly (2-ethyl-2-oxazoline) (POZ)/$AgBF_4$ membranes to increase the separation performance. FT-IR spectra show that the cationic sites ($-NH_3^+$) of valine interact with the counter anion of the silver salt, resulting in the enhanced activity of the silver ions and consequently improved separation perfornance. Therefore, the $POZ/AgBF_4$ membranes containing valines exhibit the higher permeance as well as the higher selectivity of propylene/propane than those without valine.

The Study on Performance Characteristics in Refrigeration System using R717 and R22 as working fluid (냉매 R717과 R22를 작동유체로 이용한 냉동장치의 성능특성에 관한 연구)

  • Kim, Jin-Hyun;Kim, Jae-Geun;Kim, Jong-Gil;Kim, Yang-Hyun;Hong, Suk-Ju;Ha, Ok-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.495-500
    • /
    • 2006
  • Nowadays HCFCs refrigerant are restricted because it cause depletion of ozone layer. However, natural gases such as ammonia as an organic compound, propane and propylene as hydrocarbon are easy and cheap to obtain as well as environmental. Accordingly, this experiment apply the $NH_3$ and R22 to study the performance characteristic from the superheat control and compare the energy efficiency of two refrigerants from the high performance. The condensing pressure of refrigeration system is increased from 15bar to 16bar and degree of superheat is increased from 0 to $10^{\circ}C$ at each condensing pressure. As the result of experiment, when comparing the each COP, we knew the $NH_3$ is suitable as the alternative refrigerant of the R22.

  • PDF