• 제목/요약/키워드: proportional limit

검색결과 164건 처리시간 0.024초

판형 열교환기의 열전달성능 손실 없이 유동방향 길이를 축소하는 방법 (A Method to Reduce Flow Depth of a Plate Heat Exchanger without a Loss of Heat Transfer Performance)

  • 송귀은;이대영
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.129-136
    • /
    • 2006
  • Optimal design of an air-to-liquid finned plate heat exchanger is considered theoretically in this study. Based on existing correlations for the pressure loss and the heat transfer in channel flows, the optimal configuration of the plate heat exchanger including the optimal plate pitch and the optimal fin pitch is obtained to maximize the heat transfer within the limit of the pressure drop for a given flow depth of the plate heat exchanger. It is found that the optimal fin pitch is about one ninth of the optimal plate pitch. In the optimal configuration, the flow and thermal condition in the channels is just at the boundary between the laminar developing and laminar fully developed states. It is also found when reducing the flow depth of plate heat exchangers for compactness, the heat transfer performance can be maintained exactly the same if the geometric parameters such as the plate thickness, plate pitch, fin thickness, and fin pitch are reduced proportional to the square root of the flow depth as long as the flow keeps laminar within the heat exchangers.

통신장비용 공냉형 냉각시스템의 성능 특성에 대한 실험적 연구 (Experimental Study on the Performance of an Air-Cooling System for Telecommunication Equipment)

  • 전종욱;최종민;허재혁;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.323-328
    • /
    • 2005
  • The objective of this study is to analyze the cooling performance of an air- cooling system for telecommunication equipment. Temperature variation and capacity were measured in an actual unit for telecommunication equipment. In addition, the cooling performance was measured by installing a silicon rubber heater as a heat source in a cabinet. The standard thermal load for telecommunication equipment was approximately 293 W, and the maximum temperature of the heated surface was $64.5^{\circ}C$. The average and maximum temperatures of the heated surface were proportional to the inlet air temperature. When the heat load increased from 293 W to 400 W, the maximum temperature of the heated surface was higher than $64.5^{\circ}C$ even though the inlet air temperature decreased from 25 to $11^{\circ}C$.

  • PDF

Chemiluminescence Determination of Balofloxacin Based on Europium (III)-Sensitized KBrO3-Na2S2O4 Reaction in Micellar Medium

  • Zhao, Fang;Qi, Yu;Xiong, Wei
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권1호
    • /
    • pp.204-208
    • /
    • 2012
  • A novel chemiluminescence (CL) flow injection method for the determination of balofloxacin is described. The method is based on the weak CL signal arising from the reaction of $KBrO_3$ with $Na_2S_2O_4$ in acidic medium being significantly enhanced by balofloxacin in the presence of europium (III) ion and sodium dodecyl benzene sulfonate (SDBS). The experimental conditions that affected CL intensity were carefully optimized and the CL reaction mechanism was briefly discussed. Under the optimum conditions, the relative CL intensity was proportional to the concentration of balofloxacin in the range of $7.0{\times}10^{-11}$ to $3.0{\times}10^{-7}g\;mL^{-1}$. The detection limit was $2.7{\times}10^{-11}g\;mL^{-1}$ and the relative standard deviation was 2.1% for $7.0{\times}10^{-10}g\;mL^{-1}$ balofloxacin (n = 13). The proposed method was successfully applied to the determination of balofloxacin in pharmaceutical formulations and biological fluids.

Amperometric Immunosensor for Myeloperoxidase in Human Serum Based on a Multi-wall Carbon Nanotubes-Ionic Liquid-Cerium Dioxide Film-modified Electrode

  • Lu, Lingsong;Liu, Bei;Liu, Chenggui;Xie, Guoming
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권11호
    • /
    • pp.3259-3264
    • /
    • 2010
  • A label-free amperometric immunosensor has been proposed for the detection of myeloperoxidase (MPO) in human serum. To fabricate such an immunosensor, a composite film consisting of N,N-dimethylformamide (DMF), multiwall carbon nanotubes (MWCNTs) and 1-ethyl-3-methyl imidazolium tetrafluoroborate ($EMIMBF_4$) suspension was initially formed on a glassy carbon electrode (GCE). Then cerium dioxide ($CeO_2$) dispersed by chitosan was coated on the GCE. After that, MPO antibodies (anti-MPO) were attached onto the nano$CeO_2$ surface. With a noncompetitive immunoassay format, the antibody-antigen complex formed between the immobilized anti-MPO and MPO in sample solution. The immunosensor was characterized by cyclic voltammetry, transmission electron microscopy (TEM) and scanning electron microscopy (SEM). The factors influencing the performance of the immunosensor were studied in detail. Under optimal conditions, the current change before and after the immunoreaction was proportional to MPO concentration in the range of 5 to $300\;ng\;mL^{-1}$ with a detection limit of $0.2\;ng\;mL^{-1}$.

연료극 지지체식 고체산화물 연료전지의 기계적 및 전기적 특성에 미치는 Ni-YSZ의 미세구조의 영향 (Effect of Microstructure on Mechanical and Electrical Properties in Ni-YSZ of Anode Supported SOFC)

  • 최미화;최진혁;이태희;유영성
    • 한국수소및신에너지학회논문집
    • /
    • 제22권5호
    • /
    • pp.592-598
    • /
    • 2011
  • Electrode of solid oxide fuel cell must have sufficient porosity to allow gas transport to the interface with electrolyte effectively but high porosity has a negative impact on structural stability in electrode support. Thus, the upper limit of porosity is based on consideration of mechanical strength of electrode. In this study, the effect of microstructure of Ni-YSZ anode supported SOFC on the mechanical and electrical property was investigated. LSCF composite cathode and 8YSZ electrolyte were used. The porosity of the anode was modified by the amount of graphite powder and added graphite contents were 24, 18, 12 vol%, respectively. The higher the porosity, the better the electrical performance, $P_{max}$. While the flexural strength decreased with increasing the amount of graphite. But the rate of increase in electrical performance and the rate of decrease in mechanical strength were not directly proportional to amount of graphite. The optimum graphite content incorporating both electrical and mechanical performance was 18 vol%.

Square Wave Voltammetric Determination of Indole-3-acetic Acid Based on the Enhancement Effect of Anionic Surfactant at the Carbon Paste Electrode

  • Zhang, Sheng-Hui;Wu, Kang-Bing
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권9호
    • /
    • pp.1321-1325
    • /
    • 2004
  • Sodium dodecyl sulfate (SDS), an anionic surfactant, can strongly adsorb at the surface of a carbon paste electrode (CPE) via the hydrophobic interaction. In pH 3.0 $Na_2HPO_4$-citric acid buffer (Mcllvaine buffer) and in the presence of SDS, the cationic indole-3-acetic acid (IAA, $pK_a$ = 4.75) was highly accumulated at the CPE surface through the electrostatic interaction between the negative-charged head group of SDS and cationic IAA, compared with that in the absence of SDS. Hence, the oxidation peak current of IAA increases greatly and the oxidation peak potential shifts towards more negative direction. The experimental parameters, such as pH, varieties of surfactants, concentration of SDS, and scan rate were optimized for IAA determination. The oxidation peak current is proportional to the concentration of IAA over the range from $5\;{\times}\;10^{-8}$ mol/L to $2\;{\times}\;10^{-6}$ mol/L. The detection limit is $2\;{\times}\;10^{-8}$ mol/L after 3 min of accumulation. This new voltammetric method was successfully used to detect IAA in some plant leaves.

Investigation of Linear Viscoelastic Properties of Xanthan-Carob Mixture in Sol and Gel States

  • Yoon, Won-Byong;Gunasekaran, Sundaram
    • Food Science and Biotechnology
    • /
    • 제18권3호
    • /
    • pp.618-623
    • /
    • 2009
  • Synergistic interactions between xanthan (X) and carob (C) were investigated by studying the linear viscoelastic behavior of X, C, and X/C mixtures at sol and gel states. At the solution state, storage modulus (G') dominates the linear viscoelastic properties of X/C mixtures. The gelation temperature (52 to $57^{\circ}C$) was weakly dependent on the xanthan fraction (${\phi}x$) in the mixture. The ${\phi}x$ also had a strong effect on G' until ${\phi}x=0.5$. The elastic active network concentration (EANC) of X/C gels was estimated from the pseudo-equilibrium modulus. The EANC for systems with ${\phi}x=0.25$, 0.5, 0.75, and 1 at 1% total concentration was 2.3, 4.4, 4.1, and 0.32 (${\times}10^{-3}\;mol/m^3$), respectively. The maximum synergistic effect was observed at about ${\phi}x=0.5$. The G' at the transition state of X/C mixed gel was proportional to ${\omega}^{3/2}$ at ${\omega}$>${\omega}_{tr}$ (the onset transition frequency) compared to the theoretical limit of ${\omega}^{1/2}$.

FRP(SMC재)의 균열成長 擧動과 破壞인성 평가에 관한 연구 (A study on fracture toughness evaluation and crack growth behavior in FRP (SMC material))

  • 김정규;박진성
    • 대한기계학회논문집
    • /
    • 제13권3호
    • /
    • pp.472-478
    • /
    • 1989
  • 본 연구에서는 FRP의 파괴인성평가를 위한 기초적인 자료를 얻기 위하여 FRP 중에서도 널리 사용되고 있는 SMC재를 준비하고 3점 굽힘시험을 실시하여 노치선단에서의 손상거동 및 균열진전저항유선으로부터 안정파괴개시점을 검토하였다.

고온 강구조 압축재의 좌굴 강도에 관한 연구 (A Study on Buckling Strengths for Steel Compression Members at High Temperatures)

  • 최현식
    • 한국공간구조학회논문집
    • /
    • 제19권2호
    • /
    • pp.73-81
    • /
    • 2019
  • The high-temperature properties of mild steels were studied by comparing the test results of Kwon and the yield strength, tangent modulus predicted by the design provisions of ASCE and Eurocode(EC3). The column strengths for steel members at high temperatures were determined by the elastic and inelastic buckling strengths according to elevated temperatures. The material properties at high temperatures should be used in the strength evaluations of high temperature members. The buckling strengths obtained from the AISC, EC3 and approximate formula proposed by Takagi et al. were compared with ones calculated by the material nonlinear analysis using the EC3 material model. The newly simplified formulas for yield stress, tangent modulus, proportional limit and buckling strength which were proposed through a comparative study of the material properties and buckling strengths. The buckling strengths of proposed formulas were approximately equivalent to ones obtained from the formulas of Takagi et al. within 4%. They were corresponded to the lower bound values among the buckling strengths calculated by the design formulas and inelastic buckling analysis.

Smart tracking design for aerial system via fuzzy nonlinear criterion

  • Wang, Ruei-yuan;Hung, C.C.;Ling, Hsiao-Chi
    • Smart Structures and Systems
    • /
    • 제29권4호
    • /
    • pp.617-624
    • /
    • 2022
  • A new intelligent adaptive control scheme was proposed that combines the control based on interference observer and fuzzy adaptive s-curve for flight path tracking control of unmanned aerial vehicle (UAV). The most important contribution is that the control configurations don't need to know the uncertainty limit of the vehicle and the influence of interference is removed. The proposed control law is an integration of fuzzy control estimator and adaptive proportional integral (PI) compensator with input. The rated feedback drive specifies the desired dynamic properties of the closed control loop based on the known properties of the preferred acceleration vector. At the same time, the adaptive PI control compensate for the unknown of perturbation. Additional terms such as s-surface control can ensure rapid convergence due to the non-linear representation on the surface and also improve the stability. In addition, the observer improves the robustness of the adaptive fuzzy system. It has been proven that the stability of the regulatory system can be ensured according to linear matrix equality based Lyapunov's theory. In summary, the numerical simulation results show the efficiency and the feasibility by the use of the robust control methodology.