• Title/Summary/Keyword: proportional intensity

Search Result 237, Processing Time 0.022 seconds

In Line Plastic-Optical-Fiber Temperature Sensor

  • Seo, Hyejin;Shin, Jong-Dug;Park, Jaehee
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.238-242
    • /
    • 2021
  • In this paper, we present an in line plastic-optical-fiber (POF) temperature sensor based on intensity modulation. The in line POF temperature sensor is composed of a POF, including an in-fiber micro hole filled with reversible thermochromic material, the transmittance of which depends on temperature. The reversible thermochromic material was cobalt chloride/polyvinyl butyral gel. A cobalt chloride solution of concentration 30.8 mM was formulated using 10% water/90% ethanol (v/v) solution, and gelled by dissolving polyvinyl butyral in this solution. Four types of in line POF sensors, with in line micro holes of four different diameters, were fabricated to measure temperature in the range of 25 to 75 ℃. The output optical power of all of these in line POF temperature sensors was inversely proportional to the temperature; the relation between output power and temperature was approximately linear, and the sensitivity was proportional to the diameter of the in-fiber micro hole. The experimental results indicate that an in line POF sensor can be used effectively for measuring moderate temperatures.

Chromatic Detection of Cholesterol Using Polydiacetylene Vesicles

  • Min Jae Shin
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.660-664
    • /
    • 2023
  • In this study, a new system to determine the concentration of cholesterol using a color change was developed. The system comprised diacetylene vesicles and cholesterol oxidase (ChOx). 10,12-Pentacosadiynoic acid (PCDA) was used as the diacetylene compound, and PCDA vesicles were formed using sonication. The H2O2 produced during the reaction between cholesterol and ChOx was used to initiate the polymerization of the PCDA in the vesicles. During polymerization, the vesicles changed from colorless to blue. Therefore, the cholesterol concentration was proportional to the intensity of the blue color. The absorption at 665 nm indicated that the blue color was directly proportional to the cholesterol concentration. This indicates that the system can be used for cholesterol detection. The minimum cholesterol concentration detected using this system was 1.0 mM.

Monitoring of Extraction Properties of Ginseng Components during Pressurized Micorwave-Assisted Extraction (가압조건의 마이크로웨이브 추출에서 몇가지 인삼성분의 추출특성 모니터링)

  • 권중호;이새봄;이기동;정용진;김정숙
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.5
    • /
    • pp.1087-1091
    • /
    • 1999
  • Microwave extraction system equipped with closed vessels, which is known to rapidly extract target compounds from natural products, was applied to monitor the changes in phenolic compounds, browning color intensity and electron donating ability by using response surface methodology(RSM). Maximum content of phenolic compound was 21.65mg/100ml in 67.88% of ethanol concentration, 145oC of extraction temperature, and 6.24min of extraction time. The phenolic compounds in extracts are dependent on the increase of the extraction temperature and the ethanol concentration. Browning color intensity, which was maximized in 67.21%, 147oC, and 6.02min, was proportional to the increase of the extraction temperature. Maximum value of electron donating ability was 24.50units in 54.33%, 147oC, and 6.11 min. The electron donating ability of extracts was dependent on the increase of extraction temperature and maximized in the range from 50 to 65% of ethanol concentration.

  • PDF

Analysis of Evaporative Heat Transfer in a Porous Layer by Capillary Model (모세관 모델에 의한 다공층내의 증발 열전달 해석)

  • 김홍제;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.2
    • /
    • pp.391-399
    • /
    • 1992
  • The analysis of the evaporative heat transfer in the inclined porous layer (0.deg.<.theta.<90.deg.) is made by using capillary model. The length of the evaporation zone is obtained numerically by integrating the differential equation using a Runge-Kutta algorithm. As a result, the length of the evaporation zone is inverse proportional to the dimensionless number, E(=Re*.phi./cos.theta.) representing the evaporation intensity, and the relationship of these parameters shows linear in the log graph.

Profiles of electric and magnetic fields in the vicinity of 22.9[kV] Distribution Line (22.9[kV] 배전선로 주변의 전장과 자장의 분포)

  • Lee, Bok-H.;Gil, Hyoung-J.;Ahn, Chang-H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1653-1655
    • /
    • 1998
  • In this paper, measurement and analysis of ELF electric and magnetic fields in the vicinity of 22.9[kV] distribution line have been performed. The height of measuring point from the earth's surface was 1[m], and the distance between the device and the operator was more than 3[m]. The experiments have been carried out by lateral profile, and we have made use of FIELDS program for the sake of comparision the experimental data with the theoretical value. Electric and magnetic fields intensity were strong under a distribution line, and were inversely proportional to lateral distance. The profiles of electric field were M shape and those of magnetic field were $\cap$ shape. Electric and magnetic fields intensity were increased with increasing the measurement height.

  • PDF

Profiles of Electric and Magnetic Fields around 22.9[kV] Distribution Lines (22.9[kV] 배전선로 주변의 전장과 자장의 분포)

  • ;李福熙
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.178-178
    • /
    • 1999
  • In recent years, the electromagnetic environments are varied with the increase of power consumption and the spread of household electric appliances. Most of the interests to date have concentrated in the area of human health effects associated with exposure to power frequency electric and magnetic fields, and thus the precise measurement and analysis are required. In this paper, the measurements and analysis of the extremely low frequency(ELF) electric and magnetic fields produced by actual 22.9[kV] distribution lines were performed. The experiments have been carried out by lateral profile, and the theoretical analyses were made by use of FIELDS program for the sate of comparison with the experimental data. Electric and magnetic field intensity were strong under power distribution lines, and were inversely proportional to lateral distance. The profiles of electric and magnetic fields were M and ∩ shapes, respectively, and the measured data were good in agreement with the theoretical results. Both the electric and magnetic field intensity were increased with increasing the measurement height.

Theory of Thin Sample z-scan of a New Class of Nonlinear Materials

  • Kim, Yong-K.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.246-251
    • /
    • 2003
  • We report the theory of thin-sample Z -scan for materials, viz. diffusion-dominated photorefractives, having a nonlinearly induced phase that may be proportional to the spatial derivative of the intensity profile. The on-axis far-field intensity is approximately an even function of the scan distance on different positive and negative values for phase shift $\Delta$$\Phi$$_{o}$. In case of positive phase shift, the Z -scan graph shows a minimum and two maxima, while for the negative value, only one minimum is observed. The fact is that far-field beam profiles display beam distortion and shift of the peak as compared with Kerr-type or photovoltaic nonlinearities.s.

Parameter estimation using GA with failure data under preventive maintenance (예방 정비가 실시된 고장 자료에서의 유전 알고리즘을 이용한 모수 추정)

  • 윤영원;정일한;김종운;신주환
    • Journal of Applied Reliability
    • /
    • v.1 no.1
    • /
    • pp.47-54
    • /
    • 2001
  • This paper considers the parameter estimation problem of the failure intensity function and maintenance effect in a repairable system. We propose estimation procedures for repairable systems on which preventive maintenance is performed. The failure process is modeled by a proportional age reduction model [Brown, Mahoney and Sivazlian(1983)] which is useful to model the imperfect effect of preventive maintenance. When failure and maintenance (preventive) times are given, the maximum likelihood method is used to estimate the maintenance effect and the parameters of intensity function, simultaneously We obtain the maximum likelihood estimators using a genetic algorithm. A numerical example is also presented.

  • PDF

A Study on Real-Time Corrosion Thickness Measurement Technique of Insulated Pipeline (보온재 부착 파이프라인의 부식두께 측정에 관한 연구)

  • Jang, Ji-Hun;Jo, Gyeong-Sik;Lee, Jong-O;Kim, Gi-Dong
    • 연구논문집
    • /
    • s.31
    • /
    • pp.135-147
    • /
    • 2001
  • The wall-thickness of insulated pipelines can be easily evaluated by measuring the gamma-ray transmission intensity because this intensity is inversely proportional to the thickness of insulated pipeline. The main purpose of this study is to develop the nondestructive and filmless on-line inspection system of corrosion by measuring the wall thickness of insulated pipeline. The inspection system is constructed with radioisotope, 64 channel photo diode array detector, crawler system and data taking and operating software. The traditional off-line radiographic method carried out by exposing film cassettes can be replaced by this cost-effective on-line digital imaging method and the application will be greatly expected especially in the chemical and petrochemical industries.

  • PDF

Construction of a Dynamic Laser Light Scattering System Using a Personal Computer$^\dag$

  • Kim, Myung-Joong;Lee, Sang-Yong;Chung, Koo-Soon;Lee, Hoo-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.5
    • /
    • pp.403-405
    • /
    • 1987
  • A dynamic laser light scattering system has been constructed using a personal computer. The intensity of the scattered light was detected with a photomultiplier tube and a photon counter. The BCD output of the photon counter which is proportional to the intensity of scattered light is fed into a personal computer via an interface card. The personal computer was programmed as an autocorrelator in machine language. The data acquisition rate of the system was about 600 samples/s which is adequate for studies on the molecular dynamics of concentrated polymer solutions, polymer latices with large particle size, and polymer glass systems. The constructed system was tested with polystyrene latex and the measured diameter of the latex particle agrees well with the supplier's value.