• Title/Summary/Keyword: proportional control valve

검색결과 185건 처리시간 0.023초

비례밸브를 이용한 트랙터 견인력제어시스템 개발 (Development of a Draft Control System for Tractor Using a Proportional Valve)

  • 이상식;이제용;문정환
    • Journal of Biosystems Engineering
    • /
    • 제31권1호
    • /
    • pp.9-15
    • /
    • 2006
  • Draft control is key technique in plow control system for automation of implement control system. To make the consistent draft force is an essential factor for preventing the reduction of working efficiency by tractor's slip and also improving the working efficiency. Therefore, the purpose of this study is to develop the draft sensor for draft control of plow and evaluate the usability of the algorithm of draft control system using proportional control valve. The developed draft control system could extract the draft force very well regardless of draft condition, change of setting draft force and response time in the response characteristic test. The maximum draft force at 3-Point linkage was 10,000 N and the deviation of the control system was 125.8 N in steady state condition. The developed control system worked very well with regard to the change of draft force in field and even in soil condition with soil reaction. The results of experiment showed the characteristics of response was sufficient to be used as the implement draft control system for tractor using proportional valve.

차량 능동 현가 장치용 유압 액추에이터의 감쇠력 특성에 관한 연구 (A Study on the Characteristics of Damping Force in a Hydraulic Actuator for Vehicle Active Suspension System)

  • 윤영환;최명진
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.150-158
    • /
    • 2002
  • Through experimental works, the damping force vibration problem was investigated, which results from valve and surge pressure in the oil return line of the hydraulic circuit of an active suspension system in a passenger cu. Experiments were carried out under passive system, where an orifice valve was closed and non-active system, where an orifice valve was opened, using a pressure control valve controlled by solenoid. The effects of parameters of the valve overlap and accumulator on smoothing surge pressure was elucidated. It was proved that the apparent variation of damping force due to the overlap amount of pressure control valve is the most important factor to control the damping force variation. The procedure of the experimental works shows the development process of a proportional pressure control valve in the hydraulics system of an active suspension system of passenger car.

비례밸브를 이용한 트랙터 경심 및 부하제어시스템 개발 (Development of a Depth and Working Load Control System for Tractor Using a Proportional Valve)

  • 이상식;이제용;문정환
    • Journal of Biosystems Engineering
    • /
    • 제31권1호
    • /
    • pp.16-23
    • /
    • 2006
  • Depth and working load control is one of the most important technique in control system for tractor rotary implement automation. Keeping the depth consistent is critical to bring along crops and to improve the efficiency and quality of the following operations. Keeping the load of engine consistent is an essential factor for the efficiency of operation and engine protection of tractor. In this study we investigated the possibility of application of depth and working load control system for tractor using a proportional valve through field tests. Depth control was implemented by the ascent and descent of 3 point linkage for the change of setting depth. There were 4 mm and 5.2 mm control deviations for setting depths of 50mm and 100mm, respectively. Load control was operated appropriately by the ascent and of descent of 3 point link for the change of setting working load. The standard deviations between setting load and engine load were 171 rpm at 1.3 km/h and 164 rpm at 2.3 km/h tractor travel velocity. The results of experiment showed that the characteristics of response was sufficient to be used as the implement depth and working load control system for tractor using proportional valve.

지능형 대용량 비례유량제어밸브 서보컨트롤러 설계 (Design of Intelligent Servocontroller for Proportional Flow Control Solenoid Valve with Large Capacity)

  • 정규홍
    • 유공압시스템학회논문집
    • /
    • 제8권3호
    • /
    • pp.1-7
    • /
    • 2011
  • As the technologies of electronic device have advanced these days, most of mechanical systems are designed with electronic control unit to take advantage of control parameter adaption to operating conditions and firmware flexibilities as well. On-board diagnosis, which detects the system malfunction and identifies potential source of error with its own diagnostic criteria, and fail-safe that can switch the mode of operation in view of recognized error characteristics enables easy maintenance and troubleshooting as well as system protection. This paper dealt with the development of diagnosis and fail-safe function for proportional flow control valve. All type of errors related to valve control system components are investigated and assigned to a specific hexadecimal codes. Cumulative error detection algorithm is applied in order for the sensitivity and reliability to be appropriate. Embedded simulator which runs simultaneously with system program provides the virtual error simulation environment for expeditious development of error detection algorithm. The diagnosis function was verified both with solenoid valve and embedded simulator test and it will enhance the valve control system monitoring function.

파일럿 스풀이 주 스풀에 동심 내장된 2단 방향제어밸브의 기초적 특성 (Basic Characteristics of a Two Stage Directional Control Valve with Pilot Spool Assembled in Main Spool Coaxially)

  • 이일영;손제목
    • 동력기계공학회지
    • /
    • 제14권6호
    • /
    • pp.102-108
    • /
    • 2010
  • In this study, the authors investigate the basic characteristics of a two stage directional control valve with pilot spool assembled in main spool coaxially. The step response characteristics and effects of major design parameters' values on valve performances arc clarified through numerical simulations. In addition, the authors examined the possibility of applying the object valve for this study as a proportional control valve. Based on the numerical simulation results, new design values for the reformed design as a proportional control valve were suggested.

휠로더 자동변속기용 비례 제어 밸브의 설계 특성 해석 (Design Parameter Analysis of the Proportional Control Valve for Wheel-Loader Automatic Transmission)

  • 박영준;오주영;윤웅권;이근호
    • 한국정밀공학회지
    • /
    • 제27권5호
    • /
    • pp.27-35
    • /
    • 2010
  • A loader used for uploading materials into truck is a kind of construction equipment. Mainly, a wheel loader is applied to construction work. Recently, an automatic transmission for the wheel loader is used to help drivers get the repetitive works done comfortably. It is composed of geartrain, clutch pack, hydraulic control system and TCU. Especially, a high-performance proportional control valve and its control algorithm is demanded to achieve the shift quality during a change of speed. In this paper, the commercial package program was used in order to justify model of the proportional control valve and simulate it. Steady-state and dynamic characteristics of PCV were analyzed to classify attractive forces and hydraulic control characteristics. This model also was verified the validity compared to the experimental result. Using the developed model, performances of PCV were predicted as studying design parameters.

비례 솔레노이드 밸브의 운동해석 및 LQG/LTR 제어 (Motion Analysis and LQG/LTR Control of a Proportional Solenoid Valve)

  • 김기범;김인수;김영식;김준식
    • 대한기계학회논문집A
    • /
    • 제35권12호
    • /
    • pp.1607-1612
    • /
    • 2011
  • 본 논문에서는 솔레노이드 밸브의 동특성 분석 후, 적분기가 추가된 LQG/LTR 제어기를 설계한다. 솔레노이드 밸브의 동특성은 백색잡음 입력 신호에 대한 출력응답을 측정하여 얻은 주파수 응답과 커브피팅을 통해 규명된다. 본 논문에서 적분기가 추가된 LQG/LTR 제어의 목적은 시스템의 응답성을 향상시킬 뿐만 아니라 복잡한 입력신호에 대한 추종 능력도 향상시키는 것이다. 마지막으로 실험을 통해 제어기의 성능이 검증되며, 성능이 향상되었음을 확인할 수 있다.

리니어 펄스 모터를 이용한 전자비례제어 벨브의 실용화 (Practicability of Electromagnetic Proportional Valve Using LPM)

  • 김성헌;이은웅;이승학;김옥환;이동주;김성종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.12-14
    • /
    • 1999
  • Recently, the electromagnetic proportional valve has been widely used in order to control pressure and flow in such systems as NC machine and automatic facility. The linear electromagnetic solenoid used for proportional control valve ought to have hysteresis characteristic because of control the thrust force proportionably by input current. Therefore, in this study, we analysis the thrust force characteristics and established design for practical use, which allows Linear Pulse Motor(LPM) to be used as a driving system for electromagnetic proportional control valves.

  • PDF

옥외 애자용 재료의 표면 전기 전도 특성 (Surface Electrical Conduction Properties of Composite Insulator Materials)

  • 홍현문;전병석;김종근;강성화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.409-411
    • /
    • 2005
  • In this literature, we mose the design method of a proportional pressure control valve using valve system analysis and finite element method. And it is shown that a manufactured proportional pressure control valve character is well matched to tile theoretical analysis results. Also it is verified that the proposed valve has excellent performance compared to the other foreign products.

  • PDF

3방 비례제어 조절밸브 개발 및 성능 연구 (Development of Three-Way Proportional Control Valve and Performance Study)

  • 이종화;정택수;조종두;김주용
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.218-223
    • /
    • 2014
  • Korea District heating corp. recently give an attention to combine the district heating and supply pipes as a two pipe system that are in the present system separated with room heating and warm water supply pipe, and the two pipe system is commonly applied for heating service in European countries. In the new two pipe system, only one heat source is supplied to a house and partitioned into room heating and warm water supply by household substation. So the effective distribution of supplied heat source in accordance to user intention is very important. This paper presents the development and performance test of three-way proportional control valve for a combined heat source system in district heating. The proposed valve is controlled to partition heat source into two different directions : hot water distributor for space heating and household substation for warm water supply in response to the pressure drops of tap water caused by the user. The performance investigation is shown within 3% of error compared to the theoretical model of the three-way proportional valve and its controllability is verified.