• Title/Summary/Keyword: property (M)

Search Result 2,898, Processing Time 0.037 seconds

Assessment of CO2 Geological Storage Capacity for Basalt Flow Structure around PZ-1 Exploration Well in the Southern Continental Shelf of Korea (남해 대륙붕 PZ-1 시추공 주변 현무암 대지 구조의 CO2 지중저장용량 평가)

  • Shin, Seung Yong;Kang, Moohee;Shinn, Young Jae;Cheong, Snons
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.33-43
    • /
    • 2020
  • CO2 geological storage is currently considered as the most stable and effective technology for greenhouse gas reduction. The saline formations for CO2 geological storage are generally located at a depth of more than 800 m where CO2 can be stored in a supercritical state, and an extensive impermeable cap rock that prevents CO2 leakage to the surface should be distributed above the saline formations. Trough analysis of seismic and well data, we identified the basalt flow structure for potential CO2 storage where saline formation is overlain by basalt cap rock around PZ-1 exploration well in the Southern Continental Shelf of Korea. To evaluate CO2 storage capacity of the saline formation, total porosity and CO2 density are calculated based on well logging data of PZ-1 well. We constructed a 3D geological grid model with a certain size in the x, y and z axis directions for volume estimates of the saline formation, and performed a property modeling to assign total porosity to the geological grid. The estimated average CO2 geological storage capacity evaluated by the U.S. DOE method for the saline formation covered by the basalt cap rock is 84.17 Mt of CO2(ranges from 42.07 to 143.79 Mt of CO2).

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

A Study on the Effect of O$_2$ annealing on Structural, Optical, and Electrical Characteristics of Undoped ZnO Thin Films Deposited by Magnetron Sputtering (산소 어닐링이 마그네 트론 스퍼터링으로 증착된 undoped ZnO박막의 구조적, 광학적, 전기적 특성에 미치는 영향에 대한 연구)

  • Yun, Eui-Jung;Park, Hyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.7
    • /
    • pp.7-14
    • /
    • 2009
  • In this paper, the effects of annealing conditions on the structural ((002) intensity, FWHM, d-spacing, grain size, (002) peak position), optical (UV peak, UV peak position) and electrical properties (carrier concentrations, resistivity, mobility) of ZnO films were investigated. ZnO films were deposited onto SiO$_2$/si substrates by RF magnetron sputtering from a ZnO target. The substrate was not heated during deposition. ZnO films were annealed in temperature ranges of $500\sim650^{\circ}C$ in the O$_2$ flow for 5$\sim$20 min. The film average thicknesses were in the range of 291 nm. The surface morphologies and structures of the samples were characterize by SEM and XRD, respectively. The optical properties were evaluated by photoluminescence (PL) measurement at room temperature (RT) using a He-Cd 325 nm laser. As the annealing temperature and time vary, the following relations were also observed: (1) proportional relationships among UV intensity (002) intensity, and grain size exist, (2) UV intensity is inversely proportional to FWHM, (3) there is no special relationship between UV intensity and electron carrier concentrations, (4) d-spacing is inversely proportional to (002) peak position, (5) UV peak position in the range of 3.20$\sim$3.24 eV means that ZnO films have a n-type conductivity which was consistent with that obtained from the electrical property, (6) the optimal conditions for the best optical and structural characteristics were found to be oxygen fraction, (O$_2$/(O$_2$+Ar)) of 0.2, RF power of 240W, substrate temperature of RT, annealing condition of 600$^{\circ}C$ for 20 min, and sputtering pressure of 20 mTorr.

The Study on the Marine Eco-toxicity and Ecological Risk of Treated Discharge Water from Ballast Water Management System Using Electrolysis (전기분해원리를 이용한 선박평형수관리장치의 배출수에 대한 해양생태독성 및 해양환경위해성에 관한 연구)

  • Shon, M.B.;Son, M.H.;Lee, J.;Son, Y.J.;Lee, G.H.;Moon, C.H.;Kim, Y.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.2
    • /
    • pp.88-101
    • /
    • 2013
  • The International Convention for the Control and Management of Ship's Ballast Water and Sediments was adopted at 2004 and then various BWMS (ballast water management system) have been developed. In this study, WET (whole effluent toxicity) test with algae (diatom) Skeletonema costatum as primary producer, invertebrate (rotifera) Brachionus plicatilis as 1st consumer and fish (olive flounder) Paralichthys olivaceus as predator, chemical analysis and ERA (environmental risk assessment) were conducted to assess the unacceptable effect on marine ecosystem by emitting the discharge water treated with AquaStar$^{TM}$ BWMS using electrolysis as main treatment equipment for removing the marine organisms in the ship's ballast water. The most sensitive test organism on discharge water treated with AquaStar$^{TM}$ BWMS was S. costatum that gave the NOEC value of 25.00%, LOEC value of 50.00% and 72hr-$EC_{50}$ value of 69.97% from WET test result for 20 psu salinity treated discharge water. NOEC and LOEC value of B. plicatilis and P. olivaceus exposed at 20 psu salinity treated discharge water were 50.00% and 100.00%, respectively. In the chemical analysis results, total number of substances produced by AquaStar$^{TM}$ BWMS was 18 which were bromate, 7 volatile halogenated organic compounds, 7 halogenated acetic acids, 3 halogenated acetonitriles and chloropicrin. Eighteen substances did not consider as persistence and bioaccumulative chemicals. Uncertainty of toxic property of 18 substances was high. PECs of 18 substances calculated by MAMPEC model were ranged from $4.58{\times}10^{-4}$ to $4.87{\mu}g\;L^{-1}$, PNECs of them were ranged from $1.6{\times}10^{-2}$ to $3.2{\times}10^2{\mu}g\;L^{-1}$. And, the PEC/PNEC ratio of 18 substances did not exceed 1. Therefore, ERA for produced substances indicate that the discharge water treated with AquaStar$^{TM}$ BWMS does not pose unacceptable effect on marine life. And $EC_{50}$ value of S. costatum on discharge water treated by BWMS using the electrolysis had positive correlation with initial TRO concentration, concentration and kind & level of HAAs.

Effects of Expeller Cake Fertilizer on Soil Properties and Tah Tasai Chinese Cabbage Yield in Organic Greenhouse Farm (유기농 시설하우스 토양에서 유박 시용이 토양특성 및 다채 생육에 미치는 영향)

  • Kim, Kab-Cheol;Ahn, Byung-Koo;Ko, Do-Young;Kim, Ju;Jeong, Seong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.3
    • /
    • pp.149-154
    • /
    • 2014
  • BACKGROUND: To evaluate the application level of expeller cake fertilizer(ECF), we have investigated soil chemical properties, leaf mineral contents and yield of tah tasai Chinese cabbage in a plastic film greenhouse. METHODS AND RESULTS: Five levels of fertilizer were applied as 0%(ECF 0), 50%(ECF 50), 75%(ECF 75), 100% (ECF 100) and 150%(ECF 150) by base 1,848 kg/ha of ECF. In 2012, tah tasai Chinese cabbage was planted on April 28 in a silt loam soil and harvested on July 12. Commercial yields were measured 10 times from May 10 to July 12. Electrical conductivity (2.24~3.09 dS/m), available $P_2O_5$(484~581 mg/kg) and exchangeable cations($K^+$, $Ca^{2+}$ and $Mg^{2+}$) were tended to increase by the application of ECF. However, the range of those was not significant. The contents of T-N, K, Ca and P of tah tasai Chinese cabbage leaves were 62.2~66.5 g/kg, 44.3~48.7 g/kg, 5.1~5.9 g/kg and 5.6~6.2 g/kg, respectively. The nitrogen utilization rate of tah tasai Chinese cabbage was 39.4~51.6%, and it was decreased with increased application amount of ECF. The yield of tah tasai Chinese cabbage was 9,806 to 12,730 kg/ha on the basis of application amount of ECF and it was not increased in spite of increased ECF. CONCLUSION: The optimum dose of application of ECF for cultivation of tah tasai Chinese cabbage was ranged from 924 kg/ha(as ECF 50) to 1,386 kg/ha(as ECF 75). Environment-friendly and economical amount of applied fertilizer is more important than yield for cultivation of tah tasai Chinese cabbage.

Thermal Property and Fire Resistance of Cellulose Insulation (섬유질 단열재의 열적 특성 및 내화성능)

  • Kwon, Young-Cheol;Seo, Seong Yeon;Kim, Sung Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.203-212
    • /
    • 2005
  • Cellulose insulation is primarily manufactured from recycled newsprint and treated with fire retardants for the fire resistance. Thanks to the fire retardants, it is not combustible and flammable. In addition to that, Its thermal resistance is much better than that of fiberglass or rock wool. It is made from waste paper and easily decayed when it is demolished, and it has small embodied energy. So it is very environment-friendly building material. For broader use of cellulose insulation in buildings in Korea, it is necessary to test its physical performance to compare the results with the requirements on the Korean Building Code. To this end, apparent thermal conductivity (ka) measurements of Korean-made loose-fill cellulose insulations were recently completed using equipment that was built and operated in accordance with ASTM C 518 and the fire resistance was tested in accordance with ASTM C 1485. Korean loose-fill cellulose has thermal conductivity about 5% greater than the corresponding U.S. product at the same density. This is likely due to differences in the recycled material being used. Both spray-applied and loose-fill cellulose insulation lose about 1.5% of their thermal resistivity for $5.5^{\circ}C$ increase in temperature. The fire resistance of cellulose insulation is increased in linear proportion to the increase of the rate of fire retardant. Thanks to the high fire resistance, cellulose insulation can be used as a substitution of Styrofoam or Urethane foam which is combustible. The thermal conductivity of cellulose insulation was $0.037-0.043W/m{\cdot}K$ at the mean specimen temperature from $4-43^{\circ}C$. It corresponds to the thermal resistance of "Na Grade" according to the Korean Building Code. The effect of chemical content on thermal conductivity was negligible for all but the chemical-free specimen which had the highest value for the thermal conductivity over the temperature range tested. The thermal resistance of cellulose insulation is better than that of fiberglass or rock wool, and its fire resistance is higher than that of Styrofoam or Urethane foam. Therefore it can be substituted for those above considering its physical performance. Cellulose insulation is no more expensive than Styrofoam or rock wool, so it is recommended to use it more widely in Korea.

A STUDY ON WEAR RESISTANCE OF FLOWABLE COMPOSITE RESINS (유동성 복합레진의 마모저항성에 관한 연구)

  • Yun, Yeon-Hee;Kim, Jung-Wook;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.217-225
    • /
    • 2002
  • When we use the flowable resin on the primary molars for quick handling, one of the most important property is the wear resistance. This study was performed to compare the wear resistance characteristics of four flowable composite resins [Arabesk flow (group 1), Tetric flow (group 2), Aeliteflow (group 3), Filtek flow (group 4)] to that of one control composite resin [Z100 (group 5)]. Specimen discs(n=10), 10mm wide and 2mm thick, were stored in distilled water at $37^{\circ}C$ for 7 days prior to testing. The specimens were subjected to 50,000 strokes at 2 Hz on the MTS system. During the test, the following parameters were maintained: the lateral excursion at 0.4mm, occlusal force at 2-100N with a force profile in the form of a half sine wave. The measurements of volume loss, depth of wear, and Vicker's hardness number of composite resins, and SEM observations of the polished and abraded surfaces were established. One-way ANOVA and Scheffe's multiple comparison test were employed to detect statistically significant differences among the flowable composite resin groups and the control composite group at P<.05. The following results were obtained: 1. Group 3 showed the least volume loss, while group 4 showed the greatest. The mean volume loss increased in the following order: group 3

  • PDF

Vegetation Structure and Site Environment of Natural Habitat of an Endangered Plant, Viola websteri (멸종위기 식물 왕제비꽃 자생지의 식생구조 및 입지환경)

  • Song, Jae-Mo;Lee, Gi-Yeoung;Kim, Nam-Young;Yi, Jae-Seon
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.3
    • /
    • pp.267-276
    • /
    • 2010
  • This study was performed to obtain basic data about vegetation structure and site environment of rare and endangered plant, viola websteri in five natural habitats. The dominant species of Hongcheon habitat were Pyrus pyrifolia (tree layer), Morus bombycis (subtree layer), Pyrus pyrifolia (shrub layer) and Isodon inflexus (herb layer). Mt. Yeonin habitat were dominated by Quercus mongolica (tree layer), Morus bombycis (subtree layer), Philadelphus schrenckii (shrub layer) and Viola websteri (herb layer). Mt. Yumyung habitat were dominated by Cornus controversa (tree layer), Morus bombycis (subtree layer), Fraxinus rhynchophylla (shrub layer) and Adenocaulon himalaicum (herb layer). Mt. Daebu habitat were dominated by Acer mono (tree layer), Staphylea bumalda (subtree layer), Staphylea bumalda(shrub layer) and Dryopteris crassirhizoma (herb layer). And the dominant species of Mt. Worak habitat were Larix leptolepis (tree layer), Fraxinus rhynchophylla (subtree layer), Alangium platanifolium var. macrophylum (shrub layer) and Adenocaulon himalaicum (herb layer). It was found out that the average acidity of soil pH was 5.23; 0.30ds/m for electron conductivity; 12.6% for organic matter content; 0.68% for total nitrogen; 21.66 ppm for available phosphorous; and 23.45 cmol(+)/kg for CEC. Interchangeable cation was decreased in order of $Ca^{2+}$ > $Mg^{2+}$ > $K^{2+}$. Viola websteri had positive association with Polygonatum odoratum var. pluriflorum and Geranium thunbergii but negative association with Poa sphondylodes. Species diversity index(H'), maximum Species diversity index (H' max), evenness(J') and dominance (1-J'), of investigated sites ranged 0.6816 (Mt. Worak)~0.9656 (Mt. Daebu), 1.0000 (Mt. Yeonin)~1.3010 (Hongcheon, Gangwon), 0.5330 (Mt. Worak)~0.8947 (Mt. Daebu) and 0.1053 (Mt. Daebu)~0.4670 (Mt. Worak) in woody layer and 1.0414 (Mt. Yumyung)~1.3295 (Mt. Worak), 1.4314 (Mt. Yumyung)~1.6435 (Mt. Daebu), 0.6984 (Hongcheon, Gangwon)~0.8356 (Mt. Worak) and 0.1644 (Mt. Worak)~0.3016 (Hongcheon, Gangwon) in herb layer, respectively.

Application of Borehole Radar to Tunnel Detection (시추공 레이다 탐사에 의한 지하 터널 탐지 적용성 연구)

  • Cho, Seong-Jun;Kim, Jung-Ho;Kim, Chang-Ryol;Son, Jeong-Sul;Sung, Nak-Hun
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.4
    • /
    • pp.279-290
    • /
    • 2006
  • The borehole radar methods used to tunnel detection are mainly classified into borehole radar reflection, directional antenna, crosshole scanning, and radar tomography methods. In this study, we have investigated the feasibility and limitation of each method to tunnel detection through case studies. In the borehole radar reflection data, there were much more clear diffraction signals of the upper wings than lower wings of the hyperbolas reflected from the tunnel, and their upper and lower wings were spreaded out to more than 10m higher and lower traces from the peaks of the hyperbolas. As the ratio of borehole diameter to antenna length increases, the ringing gets stronger on the data due to the increase in the impedance mismatching between antennas and water in the boreholes. It is also found that the reflection signals from the tunnel could be enhanced using the optimal offset distance between transmitter and receiver antennas. Nevertheless, the borehole radar reflection data could not provide directional information of the reflectors in the subsurface. Direction finding antenna system had a advantage to take a three dimensional location of a tunnel with only one borehole survey even though the cost is still very high and it required very high expertise. The data from crosshole scanning could be a good indicator for tunnel detection and it could give more reliable result when the borehole radar reflection survey is carried out together. The images of the subsurface also can be reconstructed using travel time tomography which could provide the physical property of the medium and would be effective for imaging the underground structure such as tunnels. Based on the results described above, we suggest a cost-effective field procedure for detection of a tunnel using borehole radar techniques; borehole radar reflection survey using dipole antenna can firstly be applied to pick up anomalous regions within the borehole, and crosshole scanning or reflection survey using directional antenna can then be applied only to the anomalous regions to detect the tunnel.

Management Plan for Humanistic and Ecological Characteristics of Suweol Village Forest in Tongyoung (통영 수월숲의 인문학적 특성 및 생태적 특성을 고려한 관리방안)

  • Lim, Eui-Jea;Lee, Soo-Dong;Kim, Mi-Jeong
    • Korean Journal of Environment and Ecology
    • /
    • v.27 no.1
    • /
    • pp.85-98
    • /
    • 2013
  • In order to propose effective conservation management plan, this study verified ecological characteristics, humanities and Social characteristics. The research site is private property which is owned belonging to the Kim's of Gimhae that have long history. The study site is more than a thousand years old and was created for protecting from typhoon. There held the religious ritual what is called Dongsinje until 1960s. There have been protected and managed by the villagers. As the results of analysis, the area of windbreak are $12,392.69m^2$. The windbreak is dominated old years deciduous broad-leaved tree such as Zelkova serrata, Celtis sinensis, Aphananthe aspera. Around there were farmlands(52.1%), urbanized area(26.3%), forest area(16.6%). The vegetation communities of windbreak were classified by considering the dominant species and current status of forest. The forest types are following as; A. aspera community(I) which is using less pressure, Platycarya strobilacea-Carpinus coreana-Z. serrata community(II). Z. serrata community(III) which is using high pressure, Z. serrata-A. aspera community(IV), Z. serrata community(V) which is damaged under canopy trees. The windbreak was in good condition whereas, there were concerns the some wrong status was being undermined such as the wrong forest restoration projects in the past, the trails that is penetrating inside the forest, building up education facilities. Therefore, in order to restore the value of windbreak what is so called Suwol forest, we should improve the problems of forest ecosystem such as wrong management, forest fragmentation by facilities and decline in forest by lack of growing the next generation trees. In addition, we should remove excessive resting facilities and lead to passive use of forest. to improve the way of wrong management, moreover, we should close off he trails that is penetrating inside the forest for improving fragmentation. We should restore vegetation restoration and fostering the next generation trees for forest ecosystem. In order to restore unique of histo-cultural and ecological forest landscape, the next generation trees should be grown up that is the dominant species in Suwol forest. Moreover, as a results of comparing the between good vegetation communities and damaged vegetation communities, it is necessary to complementary planting for demeged vegetation communities, therefore there needs to 10.8 under canopy trees, 79.7 shrubs.