• 제목/요약/키워드: proper size

검색결과 1,575건 처리시간 0.031초

컴퓨터 작업에서 마우스 종류에 따른 상완 부하 평가 (Assessment of the Upper Limb Work Load according to the Mouse Size in VDT Tasks)

  • 송영웅;김경아
    • 대한산업공학회지
    • /
    • 제37권3호
    • /
    • pp.209-215
    • /
    • 2011
  • The objective of this study was to determine whether there are differences in hand muscle activities (APB : abductor pollicis brevis, ED : extensor digitorum, ECU : extensor carpi ulnaris, and EI : extensor indicis) and subjective discomfort according to the three mouse sizes (small, medium, large) and two task types (pointing and scrolling). The mouse size and task type showed significant interaction effects on the total NEMG (p = 0.004) and on the NEMG of the abductor pollicis brevis muscle (p = 0.001). The total NEMG and the NEMG of APB showed the highest value in the 'scrolling' task using the 'small' mouse. However, the NEMG of the EI was different according to the mouse size, and the 'small' mouse showed the lowest value. The subjective discomfort was the lowest in the 'medium' mouse, and all nine subjects preferred the 'medium' size. The hand-size related anthropometric variables showed different correlations according to the task type and mouse size with the NEMGs and subjective discomfort. The results of this study could be used as a basic information for the determination of the proper mouse size according to the hand size.

국내외 여성복 사이즈체계 비교연구 -20대 여성의 피트성을 필요로하는 외의류를 중심으로- (The comparision of standard women's sizing systems between domestic and foreign country -Based on the fitted outerwear of women in their early twenties-)

  • 임영자;이형숙
    • 한국의류학회지
    • /
    • 제23권3호
    • /
    • pp.391-401
    • /
    • 1999
  • For proper communication among manufactures in various countries and for consumers' convenience in purchasing garments imported from foreign countries the ISO revised the size designation system in 1969. Since 1970's various countries have revised their standard sizing system by adapting the ISO system . The purpose of this study is (1) to satisfy domestic consumer's needs by developing a sizing system based on that of ISO for Korean women in their early twenties and (2) to contribute to entering the international fashion market by manufacturing high quality apparel products The results were as follows: (1) By measuring and analyzing of 464 female between the ages for 18 and 24 the data indicated that body height could be divided into following three groups. S(Short) : 152cm (19.2%) R(Regular) : 160cm (57.8%) L(Long) : 165cm(22.6%) (2) According to the results to analyzing body type of this study the medium hip(drop 6) is 47.4% the large hip(over drop 12) is 42.7% the 2 types covers 90.3% (3) Comparing Korean women's size with foreign women's size DOB size code is 17 JIS size code is 9AR, FNOR size codes are 36n. 38n. and Italian size cods are 40, 42

  • PDF

관 구조물 파괴에서의 크기효과 (Size Effect in Failure of Tube Structure)

  • Kim, Duk-Hyun;Kim, Doo-Hwan;Kwak, Jin-Sung
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.101-104
    • /
    • 2002
  • Almost all buildings/infrastructures made of composite materials are fabricated without proper design. Unlike airplane or automobile parts, prototype test is impossible. One cannot destroy 10 story buildings or 100-meter long bridges. People try to build 100-story buildings or several thousand meter long bridges. In order to realize "composites in construction", the following subjects must be studied in detail, for his design. Concept optimization, Simple method of analysis, Folded plate theory, Size effects in failure, and Critical frequency. Unlike the design procedure with conventional materials, his design should include material design, selection of manufacturing methods, and quality control methods, in addition to the fabrication method. In this paper size/scale effects in failure criteria is briefly explained for practicing engineers.engineers.

  • PDF

UNCERTAINTIES IN THE STAR-COUNT ANALYSIS

  • Hong, Seung-Soo;Lee, See-Woo
    • 천문학회지
    • /
    • 제21권2호
    • /
    • pp.155-171
    • /
    • 1988
  • We have examined how sensitively the extinction value determined by the method of star-count depends on such factors as the plate limit, the size of counting reseau, the non-linearity in the number distribution of stars with magnitude, and the angular resolution demanded by the given problem. We let the Poisson distribution portray the statistical nature of the countings, and chose the region containing the globule Barnard 361 as an example field. Uncertainties due to various combinations of the factors are presented in graphic forms: (1) Dynamic range in the extinction measurements is evaluated as a function of reseau size for varying plate limits. (2) Statistical errors involved in the star-count are analized in terms of the signal-to-noise ratio, the plate limit and the reseau size. (3) Systematic error due to the non-linearity in the number distribution are thoroughly analized. (4) Finally, a methodology is presented for correcting the systematic error in the observed radial density gradient. These graphs are meant to be used in selecting proper size of the reseau and in estimating errors inherent to the star-count analysis.

  • PDF

$PbTiO_3$계 세라믹스을 이용한 30MHz 레조네이터의 전기적특성 (Electrical characteristics of 30MHz resonator using $PbTiO_3$ system ceramics)

  • 오동언;류주현;박창엽;윤현상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.71-74
    • /
    • 2002
  • In this study, resonant characteristics of $Pb_{0.88}(La_{0.6}Nd_{0.4})_{0.08}(Mn_{1/3}Sb_{2/3})_{0.02}Ti_{0.98}O_3$ ceramics were investigated with the variations of electrode radius size for manufacturing the best 30MHz SMD type ceramic resonator with the size of $3.7{\times}3.1{\times}0.255mm^3$. Physical properties were proper for appling for 30MHz SMD type ceramic resonator. In third overtone thickness vibration mode, with increasing electrode radius size, resonant resistant($Z_r$) was decreased gradually. Mechanical quality factor($Q_{mt3}$) and dynamic range(D.R) showed the maximum value of 2,283, 47.1dB respectively, at 0.74mm electrode radius size.

  • PDF

과립의 크기가 인삼정제의 물리적 특성에 미치는 영향 (Effect of Granule Size on Physical Characteristics of Ginseng Tablet)

  • 박명한;성현순;김우정
    • Journal of Ginseng Research
    • /
    • 제4권1호
    • /
    • pp.96-103
    • /
    • 1980
  • The effect of granule size of dried red ginseng extract on physical characteristics on tablet such as hardness, color, yield and disintegration time was studied. A moisture proofing agent was found to be necessary to form granules without serious absorption of moisture. The result showed that decrease in particle size resulted increase of values in weight, hardness and disintegration time. The granule size of 60∼80 mesh was found to be optimum for proper color uniformity and other physical characteristics of tables.

  • PDF

전해질 입자크기에 따른 용융탄산염 연료전지 전해질 지지체의 두께변화에 관한 연구 (The Effect of Carbonate Particle Size Distributions on the Thickness Change of MCFC Electrolyte Matrix)

  • 이형근;김남진;이덕열
    • 한국전기전자재료학회논문지
    • /
    • 제11권5호
    • /
    • pp.384-393
    • /
    • 1998
  • A mixed powder of electrolyte and matrix support materials with a proper proportion was used for the fabrication of an electrolyte matrix sheet. The purpose of this study is to reduce the large change in MCFC cell thickness occurring in the initial start-up period when separate sheets of electrolyte and support are used. A focus was put on how small the carbonate particles could be made. The particle size of the carbonate powder was controlled by ball milling and the distribution was measured using a particle size analyser. The thickness change was reduced to 20% by this approach, which could be compared to 27% observed in a conventional cell. The thickness changes of electrolyte matrix have linear relation sizes of carbonate powders.

  • PDF

생사연감검사에 관한 기초시험 (Fundamental Studies on the Boiling off Test of Raw Silk)

  • 김현수;이덕로;김영진
    • 한국잠사곤충학회지
    • /
    • 제13권1호
    • /
    • pp.69-72
    • /
    • 1971
  • 1. 연감시료량의 적정량을 알아보기 위해 200, 100, 50, 20, 10gr의 생사시료를 연감검사한 결과 각처리간에는 통계적차이를 인정할 수 없었으나 실제로 시료량의 과대 과소에 따른 측정 및 처리오차를 감안할 때 100gr 시료가 적정량이었다. 2. 섬도사를 이용하여 연감검사를 할 경우 꼬인 상태와 풀은 상태로 연감처리할 경우 탄산나트륨같이 제교력이 강한 정연제에서는 차이가 없었으나 Marseilles 비누같이 제교력이 약한 것은 연감율에 있서 현저한 차이가 있었다. 3. 5종의 정연제를 비교한 결과 합성세제와 국산 Marseilles비누와 통계적 유의차를 인정 할 수 없으므로 이와의 대체 이용이 가능하다. 4. 정연제의 제교력은 대체로 정연액의 PH가 클수록 크고 작을수록 작은 경향이 있다.

  • PDF

입경(粒徑)이 다른 모래의 Column 내에서 시용(施用)된 Na-Zeolite의 이동입경별(移動粒徑別) 이동양상(移動樣相) (Differences in Fraction of Na-Zeolite Particles Passed through Sand Columns Filled with Sand Particles in Different Sizes)

  • 강신정;최정
    • 한국토양비료학회지
    • /
    • 제18권3호
    • /
    • pp.240-246
    • /
    • 1985
  • 사질답(砂質畓)의 토양개량제(土壤改良劑)로서 사용(使用)할 Zeolite의 최적(最適) 입도(粒度)를 알아보기 위한 기초실험으로서 입경(粒徑)이 다른 모래의 column에 입경별(粒徑別) Zeolite를 시용(施用)하여 Zeolite 이동(移動)을 조사(調査)한 결과(結果)는 다음과 같다. 0.1mm이상(以上) 크기의 Zeolite입자(粒子)는 96시간(時間) 투수(透水)하여도 수직이동(垂直移動)은 거의 없었다. 0.1mm이하(以下) 크기의 Zeolite입자(粒子)는 96시간(時間) 투수(透水)함으로 2~1, 1~0.5, 0.5~0.25mm sand column에서 각각 85.7, 32.64, 25.50% 이동(移動)하였다. 공극크기 측면만을 고려한 대하천 주위의 사질답(砂質畓)에 적합한 Zeolite입자(粒子)는 0.25~0.1mm fraction으로 추정되었다.

  • PDF

프리사이즈 의복에 대한 대학생 소비자의 인식 및 구매실태 조사 (A Study on the College Student Consumer's Attitude and Purchasing Practice of Free Size Clothes)

  • 임지영
    • 한국의류산업학회지
    • /
    • 제16권5호
    • /
    • pp.785-790
    • /
    • 2014
  • This study was performed to investigate purchasing practice and size satisfaction in order to establish marketing strategy and produce free-size clothes for the male and female in their 20s. Results were as follows; first, regarding the size selection method, it has been found that 71.5% of subjects answered that they buy clothes as a sales clerk chooses for them without knowing the old size name or notation. Second, 47.5% of subjects answered that free size is the size, which fits well to 55~66 size. Meanwhile, 36.1% answered that free size fits well to any body type; while 4% answered that free size fits well to 77 size. Third, regarding the clothes kind, which consumers buy most as free size, consumers buy shirts and sportswear by free size. Fourth, they were observed to purchase free-size clothes "free-size clothes what I want" and to not purchase clothes "due to the lack of right sizes." The size notation of clothes products is basic information, by which consumers can tell whether the clothes fit to self or not before the consumer would wear the clothes and confirm its fitness. Therefore, it is suggested that all clothes products would be manufactured by having KS clothes size as basic data and they would use standard size notation so that consumers would not have confusion. Standardized size notation by proper education and utilization on new KS notation method and attitude change of companies and consumers on size are suggested.