• Title/Summary/Keyword: proper Arrangement

Search Result 188, Processing Time 0.026 seconds

A Study on Collection Development Policy and Guideline Establishment in the Korean University Library (한국 대학도서관의 장서개발정책과 지침작성에 관한 연구)

  • Ryu In-Seok
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.22
    • /
    • pp.109-141
    • /
    • 1992
  • University library must have a substantial collection development policy, by which the short and long term plannings are set up to meet the goals of university education and to support university function. Only when university library organizes collection building based on the well-planned policy, can it establish the systematic collection building, which can satisfy users, support continuity of work, use budget efficiently, and solve the space problem by with-drawing the materials. But most Korean university libraries, contrary to many foreign cases, don't have proper systematic collection development policy or guideline that controls overall library work from planning the collection of materials to evaluating and preserving them. Questionaire on whether university library has collection development policy or guideline was answered positively by only 6 cases out of 57 cases, which is just 10.5 percent. Even in cases that they have a guideline, the content of the copied guideline they sent was confined to acquisition, which is just a part of collection development. Collection development is a statement needed to set up long and short term plannings in consideration of the aims of the library and the needs of users and to shape and manage the library collection systematically. With the above conception and definition, we try to make a proper collection development policy and guideline for the Korean university libraries. Here we must define the object of the university. Object of university is to have good curriculum, good courses, research activities on the part of the faculty, enlargement of graduate school, and establishment of various institutes, etc. And in guideline, selector, method of selection, level of selection and arrangement of budget, etc. must be described concretely in its contents. Since collection development policy and guideline of Korean university libraries should concern their situation, we must confer with the result of the survey and analysis on the matter of collection determination. Here the contents include the priority of materials to be collected, method of collecting materials, arrangement of budget, and others. The purpose of this study is to develop a tenative collection development guideline in reference to the Jeonju University Library by means of analyzing the guiding principle, contents of the guideline, and present conditions of the Korean university libraries. The systematic collection development based on the Guideline for Collection Development of the Korean University Library, can offer a satisfactory service to the users of the university community, and also contribute to the development of the university itself as well as the university library.

  • PDF

Numerical Analysis of Laterally Displacing Abutment in High Landfill Slope (고성토사면에 시공된 교대의 측방유동에 대한 수치해석적 연구)

  • Park, Min-Cheol;Jang, Seo-Yong;Shin, Baek-Chul;Han, Heui-Soo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.2
    • /
    • pp.27-39
    • /
    • 2012
  • This research is to propose the reinforcing method and design code for the lateral behaviors of the abutment displacement induced from the rainfall infiltration on high landfill slope. First, to make the proper numerical analysis, in-situ soil (weathered granite soil) was taken, and the variance of strength parameters according to water content variance was examined by undrained direct shear test, furthermore, other soil parameters were calculated from the standard penetration test such as elastic modulus and Poisson's ratio etc,. Those parameters were used to calculate the lateral behavior of abutment by finite element method and the member force of pile in high landfill slope according to rainfall infiltration . From the results, the shoe displacement on abutment was calculated as 8.98cm, which is 3 times bigger than the allowable displacement, 3cm. To reinforce it, several reinforcing methods were selected and analyzed such as reinforced retaining wall, soil surcharge, pile reinforcing (5m enlargement, 3-line arrangement, 5m enlargement and 3-line arrangement). In case of 5m enlarged and 3-line arrangement piles, the lateral behavior of shoe showed lower value(2.26 cm) than allowable displacement.

Heat Exchanging Performance as Affected by Arrangement of Heat Exchanging Pipe (열회수장치의 열교환 파이프배치 형식별 열교환 성능)

  • 윤용철;강종국;서원명
    • Journal of Bio-Environment Control
    • /
    • v.11 no.3
    • /
    • pp.101-107
    • /
    • 2002
  • This study was carried out to improve the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. Three different units were prepared far the comparison of heat recovery performance; A-type is exactly the same with the typical one fabricated for previous study of analyzing heat recovery performance in greenhouse heating system, other two types (B-type and C-type) modified from the control unit are different in the aspects of airflow direction (U-turn airflow) and pipe arrangement. The results are summarized as follows ; 1. In the case of Type-A, when considering the initial cost and current electricity fee required for system operation, it was expected that one or two years at most would be enough to return the whole cost invested. 2. Type-B and Type-C, basically different with Type-A in the aspect of airflow pattern, are not sensitive to the change of blower capacity with higher than 25m$^3$.min$^{-1}$ . Therefore, heat recovery performance was not improved so significantly with the increment of blower capacity. This was assumed to be that air flow resistance in high air capacity reduced the heat exchange rate as well. Never the less, compared with control unit, resultant heat recovery rate of Type-B and Type-C was improved by about 5% and 13%, respectively 3. Desirable blower capacity of these heat recovery units experimented were expected to be about 25m$^3$.min$^{-1}$ , and at the proper blower capacity, U-turn airflow units showed better heat recovery performance than control unit. But, without regard to the type of heat recovery unit, it was recommended that comprehensive consideration of system's physical factors such as pipe arrangement density, unit pipe length and pipe thickness, etc., was required for the optimization of heat recovery system in the aspects of not only energy conservation but economic system design.

Study on service and Use the Actual conditions of Day care Center for the elderly - with A Focus on Adult Day Care Facilities - (노인주간보호시설의 프로그램운영과 공간구성관계연구 - 경기도 노인주간보호시설을 중심으로 -)

  • Kim, Yong-Woong;Park, Kyung-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.2
    • /
    • pp.135-141
    • /
    • 2013
  • As the country's elderly people who are 65 years or older recently exceeded 10% of the total population with development of medical technology and improvement of living standards, Korea has turned into an aging society. Especially in Gyeonggi-do, as of late December 2012, elderly people who were 65 years or older were 1,135,242 persons, taking up 18.98% of the region's population and registering the largest number of elderly people in the nation's cities or provinces. Due to such a sharp rise in elderly population, support for the elderly is increasing the burden on families and communities. The study aims to take as its subjects elderly people staying at authorized elderly welfare facilities, who are weak in mind and body and have difficulty in daily life with disabilities, or adult day care facilities that take care of elderly people during the day or at night, examine the concept of adult day care facilities and instances in foreign countries, and study the status of the adult day care facilities located in Gyeonggi-do, their services, and safety by figuring out space arrangement based on program implementation. Spacial arrangement in program operation should satisfy fuction and purpose from the manager and user's perspective, and a desirable program operation should provide separate spaces for the elderly with Alzheimer's and those without Alzheimer's. Compared to residential care facilities, adult day care facilities incur less financial burden and, compared to other authorized services, have many right functions that can upgrade the quality of users and satisfy their desires. Major countries like Japan, the UK, and Sweden recognize the right functions of day and night care services and aggressively support and utilize adult day care facilities. For adult day care facilities, quality services should be developed and use and choices should be enhanced as regards services. Development of special programs for the elderly with dementia and stroke, instead of simple protective functions of a program, must be actively promoted, while manpower training is required for program operation, conveniences, and safety. By developing and providing space arrangement models that focus on efficiency, convenience, and safety of program operation, adult day care operation can be revitalized, while quality of elderly care may be enhanced and welfare budget can be saved.

CFD Analysis on the Heat Transfer Performance with Various Obstacles in Air Channel of Air-Type PV/Thermal Module (공기식 태양광/열 시스템 공기채널 내 여러 저항체 설치에 따른 전열성능에 관한 CFD 해석)

  • Choi, Hwi-Ung;Fatkhur, Rokhman;Kim, Young-Bok;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.2
    • /
    • pp.33-43
    • /
    • 2018
  • PV/Thermal module is the combined system, which consist of a photovoltaic module and solar thermal collector that can obtain electrical power and thermal energy simultaneously. Thus the power generation can be increase by decreasing the temperature of photovoltaic module and thermal energy retrieved from module also can be used for heating system. In this study, Heat transfer performance of air type PV/Thermal module was confirmed with various bottom obstacles that can be installed easily to real photovoltaic module by CFD (computational fluid dynamics) analysis. Eight type obstacles were investigated according to the shape and arrangement. As a result, nusselt number represent heat transfer performance was increased about 86% compare with the basic type PV/Tthermal module that has no obstacle and triangle type obstacle had higher value than other types. But pressure drop was also increased with increment of heat transfer enhancement. Thus the performance factor considering both heat transfer and pressure drop was confirmed and V-fin type obstacle arranged in a row for Reynolds number below 9,600 and protrusion type obstacle arranged in zigzag for Reynolds number above 14,400 were shown higher performance factor than other types. From these results, V-fin type obstacle arranged in row and protrusion type obstacle arranged in zigzag were considered as a proper type for applying to real PV/thermal module according to operating condition. But the heat transfer performance can be changed by the geometric conditions of obstacle such as height, width, length and arrangement. Thus, it could also confirmed that the optimal condition and arrangement of this obstacle need to be found in further study.

Facilities Standards by Local Education Offices and Characteristics of Spatial Composition Applied by Changes in the Construction Documents Phase - Focused on Schools in Gyeonggi, Deajeon and Chungcheong Districts - (교육청별 시설기준과 실시설계시 변경 적용된 공간구성의 특징 -경기, 대전, 충청지역 학교를 중심으로-)

  • Park, Im-Ho;Jung, Jin-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.4
    • /
    • pp.57-67
    • /
    • 2011
  • In this study, it did comparative analysis on the arrangement, construction and size of rooms applied in the early design stage at the time of prize-winning with the changed ground plans in the final design of those prize-winning works in design contests and BTL hold since 2007 for middle and high schools in Gyeonggi, Daejeon, Chungcheong regions. Through the analysis, this study intends to present those matters to be changed in the facilities standards of each local education office so that it can be referred to the assessment of spatial construction and proper size being planned in the future for middle and high schools and reflected flexibly in consideration of various educational conditions and characteristics of schools by regions. Furthermore, it has the objective to play a part for the establishment of much better environment of educational facilities by provision of reference materials to those matters being changed into proper ones not into the minimum ones of the school facilities standards as the national level. For case analysis, it analyzed various rooms classified by necessary spaces. Since names of rooms and spatial constructions to constitute facilities are different from each local education office and also the analysis by each room has some limitation in the changes and improvement of rooms for a wide range, it proceeded with detailed classifications of school building facilities by each necessary space.

  • PDF

Development of a Variable Rate Granule Applicator for Environment-Friendly Precision Agriculture (II) - Development of Pneumatic Fertilizer Blow Head and Its Application Uniformity - (친환경 정밀농업을 위한 입제 변량살포기 개발 (II) -송풍식 붐형 분두 개발과 살포균등도 -)

  • Kim, Y.J.;Kim, H.J.;Seo, M.;Rhee, J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.474-481
    • /
    • 2006
  • In this paper, a new type blow head was developed and pneumatic application system was evaluated. The blow head had one operating factor, inserting length of collecting plate, that was directly related to discharge rate and application pattern. To determine Proper blow head arrangement and application height, a blow head set was tested. Three-way ANOVA was conducted to investigate relationships between CV value, the discharge rate and inserting length of collecting plate. The discharge rate and inserting length of collecting plate were statistically significant at p=0.01, affecting uniformity of application pattern. The best CV value among the application tests was 23.3% when the application rate and application height was 23.5 g/sec and 80 cm respectively. The worst CV value was 63.3% in 111.4 g/sec. Therefore, it is necessary to increase number of blow head in a section of the boom in improve application uniformity.

Measures of Effectiveness and Selection Criteria of Technology Development (산업기술도입의 선정기준과 효율측정)

  • Kim, Jae-Ju;Lee, Myeon-Ryang;Jeong, Yeong-Sam
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.2 no.1
    • /
    • pp.37-44
    • /
    • 1976
  • It is necessary for developing countries to increase their consolidation of domestic technology in order to improve their economy. In order to raise their techniques, they have to try to induce the advanced know-how from other countries in spite of heavy cost. The object of this study is to establish the model on which we base our choice of the proper techniques or plants and give priority to them by using quantified selection criteria. The method in this study has two stages, and the writer has selected 12 factors affecting the decision making for the importation of technology from the industrially advanced countries. First, the lists of valuable know-how for the better development of national industry should be determined, and for the formulation and arrangement of the lists, a council of specialists which uses questionnaires in terms of the Semantic Differential Method, should be organized. Second, for the assignments of priority to the prospective items for importation, the writer has imployed both the Leontief Model and the Disman Model as objective methods and Mottley-Newton method, one of the R&D Project Selection Methods, as a general model. The writer has applied the methods described above to the fields of petrochemical industry in Korea.

  • PDF

A Development of Methodology for NOVEC Gas Fire Extinguishing System (NOVEC 가스 소화 설비 설계방법론 개발)

  • Yun, Jeong-In;Choi, Jae-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.206-210
    • /
    • 2015
  • The most important thing for NOVEC gas fire extinguishing equipment is to release NOVEC gas, which contained in the extinguishing container, to the safety section by the time appointed. For this matter, it is significant to decide arrangement and size of the proper piping equipment. This study has developed the design methodology of NOVEC gas fire extinguishing equipment in use of pipe network analysis techniques. Based on the design methodology, each design coefficient is chosen. It is found that the calculated result, which is 6.498 seconds, has been counted within the 10 seconds limit, which is fairly satisfied with extinguishing releasing time based on the developed methodology. At that time, the pressure loss is 21.09bar.

Accuracy Analysis of GNSS-derived Orthometric Heights on the Leveling Loop Disconnected Area

  • Jung, Sung Chae;Kwon, Jay Hyoun;Lee, Jisun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • To compensate for the shortcomings of spirit leveling, research on the determination of GNSS (Global Navigation Satellite System)-derived orthometric height has been actively carried out. However, most analyses were primarily performed inland. In this study, the influences of the arrangement of control points, observation duration, and geoid model on the accuracy of the GNSS-derived orthometric height have been analyzed to suggest the proper method to apply the determination of GNSS-derived orthometric height to the leveling loop disconnected area. As a result, it was found that two known points located near the unknown points need to be fixed in the leveling loop disconnected area. Further, 3 cm level of accuracy can be achieved if the GNSS survey is performed over two days, for four hours per day. In terms of the geoid model, the latest national geoid model should be applied rather than the EGM08 (Earth Gravitational Model 2008) to minimize regional bias and increase accuracy. Future research is necessary to apply the determination of the GNSS-derived orthometric height technique as a method to connect with the islands because the vertical reference system used inland and that used for the islands in Korea are still different.