• 제목/요약/키워드: proof-error

검색결과 83건 처리시간 0.027초

크레인 안전인증기준에 대한 인간공학적 분석 및 개선 (Ergonomic Analysis and Improvement of Crane Safety Certification Standards)

  • 이용석;정기효
    • 대한안전경영과학회지
    • /
    • 제23권3호
    • /
    • pp.1-9
    • /
    • 2021
  • Crane is an important equipment for the transport of heavy goods in industrial sites, but it is also known as one of the most fatal machines. In order to reduce crane accidents, it is necessary to minimize human errors during crane operations. To achieve this, ergonomic design principles are recommended to be reflected from the crane design stage. The study analyzed the safety certification standards for crane that should be fulfilled at the crane design and manufacturing stage. This study selected five representative ergonomic design principles (feedback, compatibility, consistency, full-proof, and fail-safe) by surveying heuristic evaluation principles that are widely used for usability evaluation in early design stage. Next, the principles were applied to the safety certification standards to identify insufficient clauses. This study identified 12 insufficient clauses out of 119 in the current safety certification standards for crane and discussed their improvement directions to comply the ergonomic principles. The analysis results of this study can help of improving the safety certification standards and the method used in this study can also be applied to identify insufficient clauses in the safety certification standards for other industrial machines such as press machine and lift.

Analysis of pipe thickness reduction according to pH in FAC facility with In situ ultrasonic measurement real time monitoring

  • Oh, Se-Beom;Kim, Jongbeom;Lee, Jong-Yeon;Kim, Dong-Jin;Kim, Kyung-Mo
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.186-192
    • /
    • 2022
  • Flow accelerated corrosion (FAC) is a type of pipe corrosion in which the pipe thickness decreases depending on the fluid flow conditions. In nuclear power plants, FAC mainly occurs in the carbon steel pipes of a secondary system. However, because the temperature of a secondary system pipe is over 150 ℃, in situ monitoring using a conventional ultrasonic non-destructive testing method is difficult. In our previous study, we developed a waveguide ultrasonic thickness measurement system. In this study, we applied a waveguide ultrasonic thickness measurement system to monitor the thinning of the pipe according to the change in pH. The Korea Atomic Energy Research Institute installed FAC-proof facilities, enabling the monitoring of internal fluid flow conditions, which were fixed for ~1000 h to analyze the effect of the pH. The measurement system operated without failure for ~3000 h and the pipe thickness was found to be reduced by ~10% at pH 9 compared to that at pH 7. The thickness of the pipe was measured using a microscope after the experiment, and the reliability of the system was confirmed with less than 1% error. This technology is expected to also be applicable to the thickness-reduction monitoring of other high-temperature materials.

실차기반 LIN-CAN 연계 통합 분석 테스트베드 개발과 초음파센서 물리적 오류주입 및 분석을 통한 효용성 검증 (Commercial ECU-Based Test-Bed for LIN-CAN Co-Analysis and Proof on Ultrasonic Sensors through Physical Error Injection)

  • 김윤지;고예지;오인수;임강빈
    • 정보보호학회논문지
    • /
    • 제33권2호
    • /
    • pp.325-336
    • /
    • 2023
  • 자율주행 기술이 발전함에 따라 차량에 탑재되는 외부접점 센서의 수가 증가하고 있으며 특히 차량용 초음파 센서는 버스 토폴로지 형태로서 LIN 프로토콜을 사용하여 연결되며 주변을 감지하고 상태 메시지를 전송하여 차량 내부 네트워크에 접근한다. LIN은 프로토콜의 보안성이 검증되지 않아 공격에 취약하기 때문에 안전성을 평가하기 위한 테스트가 필요하지만, 물리적인 제약으로 인해 실제 차량을 이용한 분석에 한계가 있으며 이를 위한 테스트 환경이 부족하기 때문에 테스트에 어려움이 있다. 따라서, 본 논문에서는 LIN 프로토콜 분석 및 테스트를 위해 CAN과의 연동 분석이 가능한 테스트베드를 개발하고 초음파 센서를 이용하여 그 효용성을 검증하였다.

질량-스프링 구조를 이용한 새로운 광세기 기반 광섬유 진동센서 (Novel Intensity-Based Fiber Optic Vibration Sensor Using Mass-Spring Structure)

  • 호 일;김현호;최상진;반재경
    • 전자공학회논문지
    • /
    • 제51권6호
    • /
    • pp.78-86
    • /
    • 2014
  • 본 논문에서는 질량-스프링 구조를 이용한 새로운 광세기 기반 광섬유 진동센서를 제안하고 시뮬레이션과 부분 실험을 통하여 그 실현 가능성을 제시한다. 제안한 광세기 기반 광섬유 진동센서는 네 개의 구불구불하게 휘어지는 스프링과 질량체 안의 사각형 개구면(aperture)으로 구성된 질량-스프링 구조를 가진다. 광시준기(optical collimator)는 질량체 안의 사각형 개구면의 변위에 의해서 변조되는 광을 넓히는 데 이용된다. 제안한 광섬유 진동센서를 광학적인 면과 기계적인 면에서 해석하고 설계한다. 기계적인 부분의 설계는 이론적인 해석, 수학적인 모델링 및 3 차원 유한요소법 시뮬레이션을 이용한다. 기계적인 진동이 가해질 때 개구면의 상대적인 변위관계를 3차원 유한요소법 시뮬레이션을 이용하여 구하고, 개구면의 상대적인 변위에 따른 출력값을 실험을 통하여 측정한다. 이를 이용하여 진동에 따른 출력 특성을 파악한 결과 센서 민감도 $15.731{\mu}W/G$, 감지영역 ${\pm}6.087G$를 얻었다. 그리고 입력광원의 파워가 10 dB까지 변하더라도 참조광을 이용하여 0.75%의 상대오차를 보이는 매우 안정된 출력광 파워를 얻었다. 제안한 광섬유 진동센서는 간단한 구조, 저비용 및 다지점 측정 가능의 특징을 가지면서, MEMS (Micro-Electro-Mechanical System) 기술을 이용하여 소형으로 간편하게 제작할 수 있는 잠재력을 가진다.

속도제어를 위한 유도전동기 자속추정 시뮬레이터 적용에 관한 연구 (A Study on the Flux Estimation Simulator Application for the Induction Motor Speed Control)

  • 황락훈;나승권;최기호
    • 한국산학기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.1289-1301
    • /
    • 2011
  • 본 논문에서는 전 속도 영역에서 안정적인 자속추정이 가능한 유도전동기 자속추정방법을 제안 하였다. 제안된 방법은 전압, 전류, 속도 등의 정보를 통하여 자속각을 연산하는 유도전동기 직접벡터제어방식을 이용하였다. 유도전동기 벡터제어에 있어서 자속정보는 필수적이기 때문에 정확한 자속을 추정하기 위한 방법으로 저속영역에서 는 전류모델 자속 추정기를, 고속영역에서는 전압모델 자속 추정기를 각각 이용함으로써 전 속도영역에서 정확한 자속을 추정할 수 있었다. 또한 기본적인 속도, 전류, 자속제어기는 PI제어기를 이용하였으며, 각각의 적분에 의한 오차를 보상하기 위하여 Anti-windup PI 제어기를 추가하였다. 제시한 제어기의 타당성을 알아보고자 Matlab / simulink를 이용하여 전류모델, 전압모델 자속 추정기를 설계하여 정확한 자속추정이 이루어짐을 확인하였으며, 유도 전동기 벡터제어 시 간접벡터와 직접벡터방식의 파라미터 영향에 따른 분석을 통해 보다 정밀한 제어가 이루어짐을 확인하였다. 이와 같은 시뮬레이션 결과를 분석 하여 제시한 알고리즘의 타당성을 입증하였다.

Application of Wavelet-Based RF Fingerprinting to Enhance Wireless Network Security

  • Klein, Randall W.;Temple, Michael A.;Mendenhall, Michael J.
    • Journal of Communications and Networks
    • /
    • 제11권6호
    • /
    • pp.544-555
    • /
    • 2009
  • This work continues a trend of developments aimed at exploiting the physical layer of the open systems interconnection (OSI) model to enhance wireless network security. The goal is to augment activity occurring across other OSI layers and provide improved safeguards against unauthorized access. Relative to intrusion detection and anti-spoofing, this paper provides details for a proof-of-concept investigation involving "air monitor" applications where physical equipment constraints are not overly restrictive. In this case, RF fingerprinting is emerging as a viable security measure for providing device-specific identification (manufacturer, model, and/or serial number). RF fingerprint features can be extracted from various regions of collected bursts, the detection of which has been extensively researched. Given reliable burst detection, the near-term challenge is to find robust fingerprint features to improve device distinguishability. This is addressed here using wavelet domain (WD) RF fingerprinting based on dual-tree complex wavelet transform (DT-$\mathbb{C}WT$) features extracted from the non-transient preamble response of OFDM-based 802.11a signals. Intra-manufacturer classification performance is evaluated using four like-model Cisco devices with dissimilar serial numbers. WD fingerprinting effectiveness is demonstrated using Fisher-based multiple discriminant analysis (MDA) with maximum likelihood (ML) classification. The effects of varying channel SNR, burst detection error and dissimilar SNRs for MDA/ML training and classification are considered. Relative to time domain (TD) RF fingerprinting, WD fingerprinting with DT-$\mathbb{C}WT$ features emerged as the superior alternative for all scenarios at SNRs below 20 dB while achieving performance gains of up to 8 dB at 80% classification accuracy.

광탄성 응력측정을 위한 투과형 원형편광기 제작 및 시험 (Construction and Calibration Test of a Transmission-type Circular Polariscope for Photoelastic Stress Measurement)

  • 백태현;고승기;나의균;김장섭;차병석;조성호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.437-441
    • /
    • 2001
  • This paper describes the construction of a circular polariscope. Generally, a circular polariscope contains four optical elements and a light source. The first element following the light source is called the polarizer. It converts the ordinary light into plane-polarized light. The second element is a quarter wave plate which converts the plane-polarized light into circularly polarized light. Following the quarter wave plate, a specimen made of transparent photoelastic material is located in a loading device. The second quarter wave plate is set and the last element is the analyzer. These polarizing elements, two quarter wave plates and two polarizing filters, were purchased from the USA. Frames and other structures for holding polarizing filters were machined and assembled to be rotated. Light box, which include four incandescent lamps and two sodium-vapor lamps, was made. In order to proof the function of the newly built polariscope, Tardy compensation test was applied to a rectangular shaped specimen made of poly-carbonate material (PSM1). The error of the fringe constant, which was measured by the newly built polariscope, was within 4.4 percent compared to the standard value of this material. It is possible to make a good quality of polariscope if accurate polarizing filters will be used.

  • PDF

사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용 (Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1)

  • 정환석;이동주
    • 산업경영시스템학회지
    • /
    • 제41권1호
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.

Correlation Extraction from KOSHA to enable the Development of Computer Vision based Risks Recognition System

  • Khan, Numan;Kim, Youjin;Lee, Doyeop;Tran, Si Van-Tien;Park, Chansik
    • 국제학술발표논문집
    • /
    • The 8th International Conference on Construction Engineering and Project Management
    • /
    • pp.87-95
    • /
    • 2020
  • Generally, occupational safety and particularly construction safety is an intricate phenomenon. Industry professionals have devoted vital attention to enforcing Occupational Safety and Health (OHS) from the last three decades to enhance safety management in construction. Despite the efforts of the safety professionals and government agencies, current safety management still relies on manual inspections which are infrequent, time-consuming and prone to error. Extensive research has been carried out to deal with high fatality rates confronting by the construction industry. Sensor systems, visualization-based technologies, and tracking techniques have been deployed by researchers in the last decade. Recently in the construction industry, computer vision has attracted significant attention worldwide. However, the literature revealed the narrow scope of the computer vision technology for safety management, hence, broad scope research for safety monitoring is desired to attain a complete automatic job site monitoring. With this regard, the development of a broader scope computer vision-based risk recognition system for correlation detection between the construction entities is inevitable. For this purpose, a detailed analysis has been conducted and related rules which depict the correlations (positive and negative) between the construction entities were extracted. Deep learning supported Mask R-CNN algorithm is applied to train the model. As proof of concept, a prototype is developed based on real scenarios. The proposed approach is expected to enhance the effectiveness of safety inspection and reduce the encountered burden on safety managers. It is anticipated that this approach may enable a reduction in injuries and fatalities by implementing the exact relevant safety rules and will contribute to enhance the overall safety management and monitoring performance.

  • PDF

A New Cancer Cell Detection Method Using an Infectivity-enhanced Adenoviral Vector

  • Uchino, Junji;Takayama, Koichi;Nakagaki, Noriaki;Shuo, Wang;Hisasue, Junko;Nakatom, Keita;Ohta, Keiichi;Hirano, Ryosuke;Tashiro, Naoki;Miiru, Izumi;Fujita, Masaki;Watanabe, Kentaro;Nakanishi, Yoichi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권11호
    • /
    • pp.5551-5556
    • /
    • 2012
  • Cytological examination is widely used as a diagnostic tool because of the ease of collecting cells from the involved area. However, the diagnostic yield of cytological examination is unsatisfactory; the reasons include sampling error, poorly prepared samples, small numbers of malignant cells, and low grades of cellular atypia. In this study, we focused on the high infectivity of adenovirus towards epithelial cells and applied the luciferase-expressing adenoviral vector to a new cancer cell detection tool. In addition, adenoviral infectivity was enhanced by modifying viral fiber proteins. The sensitivity of the diagnostic tool was tested using the NCI-H1299 lung cancer cell line, and validated in body fluid samples from cancer patients with a variety of etiology. Results showed that the adenovirus efficiently transfected NCI-H1299 with high sensitivity. Only 10 cancer cells were sufficient for detection of luciferase signals. In body fluid samples, the adenovirus confirmed the diagnosis for malignant and benign cancer, but not in non-epithelial cell derived samples. This study provides proof-of-concept for a more reliable and sensitive diagnostic tool for epithelium-derived cancer.