• 제목/요약/키워드: proof pile load test

검색결과 6건 처리시간 0.016초

Reliability analysis of piles based on proof vertical static load test

  • Dong, Xiaole;Tan, Xiaohui;Lin, Xin;Zhang, Xuejuan;Hou, Xiaoliang;Wu, Daoxiang
    • Geomechanics and Engineering
    • /
    • 제29권5호
    • /
    • pp.487-496
    • /
    • 2022
  • Most of the pile's vertical static load tests in construction sites are the proof load tests, which is difficult to accurately estimate the ultimate bearing capacity and analyze the reliability of piles. Therefore, a reliability analysis method based on the proof load-settlement (Q-s) data is proposed in this study. In this proposed method, a simple ultimate limit state function based on the hyperbolic model is established, where the random variables of reliability analysis include the model factor of the ultimate bearing capacity and the fitting parameters of the hyperbolic model. The model factor M = RuR / RuP is calculated based on the available destructive Q-s data, where the real value of the ultimate bearing capacity (RuR) is obtained by the complete destructive Q-s data; the predicted value of the ultimate bearing capacity (RuP) is obtained by the proof Q-s data, a part of the available destructive Q-s data, that before the predetermined load determined by the pile test report. The results demonstrate that the proposed method can easy and effectively perform the reliability analysis based on the proof Q-s data.

검증용 정재하시험을 이용한 타입강관말뚝의 저항계수 보정 (Local Resistance Factor Update of Driven Steel Pipe Piles Using Proof Pile Load Test Results)

  • 박재현;김동욱;정충기;김성렬
    • 대한토목학회논문집
    • /
    • 제31권6C호
    • /
    • pp.259-266
    • /
    • 2011
  • 기초구조물의 신뢰성 있는 저항계수 산정을 위해서는 충분한 양의 재하시험 결과에 근거한 저항의 분포특성 분석이 선행되어야 한다. 본 연구에서는 베이지안 이론에 근거하여 검증용 정재하시험 결과를 저항의 분포특성 분석에 반영할 수 있는 개선된 해석법을 제안하였고, 이를 통해 기 제안된 국내 타입강관말뚝의 저항계수를 갱신하였다. 측정 지지력이 확인된 정재하시험 결과를 이용하여 저항의 사전 분포특성을 산정하고, 검증용 정재하시험 결과를 우도정보로 고려하여 저항의 사후 분포특성을 평가하였다. 갱신된 저항의 사후 분포특성을 이용하여 일차신뢰도법에 의해 저항계수를 산정하였다. 총 5회의 검증용 재하시험 결과를 반영할 경우, 갱신된 저항계수는 목표신뢰도지수 2.33, 3.0에 대하여 각각 0.27-0.96, 0.19-0.68의 범위를 나타내었다. 본 연구에서 제시된 해석법을 통해 양질의 측정지지력 데이터가 부족하여 신뢰성 있는 저항계수를 산정하기 어려운 경우 현장 검증시험 결과를 반영한 저항계수의 보정이 가능함을 확인하였다.

검증용 정재하시험 자료를 이용한 항타강관말뚝의 신뢰성 평가 (Reliability Updates of Driven Piles Using Proof Pile Load Test Results)

  • 박재현;김동욱;곽기석;정문경;김준영;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.324-337
    • /
    • 2010
  • For the development of load and resistance factor design, reliability analysis is required to calibrate resistance factors in the framework of reliability theory. The distribution of measured-to-predicted pile resistance ratio was constructed based on only the results of load tests conducted to failure for the assessment of uncertainty regarding pile resistance and used in the conventional reliability analysis. In other words, successful pile load test (piles resisted twice their design loads without failure) results were discarded, and therefore, were not reflected in the reliability analysis. In this paper, a new systematic method based on Bayesian theory is used to update reliability index of driven steel pile piles by adding more pile load test results, even not conducted to failure, into the prior distribution of pile resistance ratio. Fifty seven static pile load tests performed to failure in Korea were compiled for the construction of prior distribution of pile resistance ratio. Reliability analyses were performed using the updated distribution of pile resistance ratio and the total load distribution using First-order Reliability Method (FORM). The challenge of this study is that the distribution updates of pile resistance ratio are possible using the load test results even not conducted to failure, and that Bayesian update are most effective when limited data are available for reliability analysis or resistance factors calibration.

  • PDF

베이지안 이론을 이용한 타입강관말뚝의 신뢰성 평가 (Reliability Updates of Driven Piles Based on Bayesian Theory Using Proof Pile Load Test Results)

  • 박재현;김동욱;곽기석;정문경;김준영;정충기
    • 한국지반공학회논문집
    • /
    • 제26권7호
    • /
    • pp.161-170
    • /
    • 2010
  • 기초구조물의 저항계수 산정 및 하중저항계수설계법의 개발을 위해서는 충분한 양의 데이터베이스 구축을 바탕으로 정확한 신뢰성 분석이 수행되어야 한다. 기존 국내외 말뚝기초의 신뢰성 분석 연구에서는 말뚝의 측정지지력 확인이 가능한 재하시험 자료만을 이용하여 저항편향계수의 분포특성을 산정하였다. 따라서, 파괴에 이르지 않은 말뚝재하시험 자료는 신뢰성 분석에서 제외되었다. 본 연구에서는 베이지안 이론을 이용하여 타입강관말뚝 저항편향계수의 사전 분포특성에 측정지지력을 확인할 수 없는 재하시험 결과를 추가하여 현장 특성을 반영한 저항편향계수의 사후분포특성을 산정하였다. 그리고 저항편향계수의 사후분포특성을 이용하여 말뚝의 신뢰성 평가를 수행하고 신뢰도수준을 갱신하였다. 국내 전역에서 수행된 양질의 정재하시험 자료를 수집, 분석하여 57개의 자료에 대한 측정지지력을 확인하였고, 이들 자료에 대해서 구조물기초설계기준에서 제안하고 있는 Meyerhof 공식을 이용하여 설계지지력을 산정하였다. 이를 통해 저항편향계수의 사전분포 특성을 정량화 하였으며, 베이지안 기법을 적용하여 다양한 현장재하시험 결과에 따라 저항편향계수의 사후분포를 산정하였다. 갱신된 저항편향계수 통계특성을 적용하여 일차신뢰도법을 이용하여 강도 높은 신뢰성 해석을 수행하고 시험결과에 따른 신뢰도 수준을 평가하였다. 본 연구에서 제시된 방법을 통해 양질의 측정지지력 데이터가 부족한 경우 베이지안 기법을 이용하여 신뢰성 분석이 가능함을 확인하였다.

양방향 고유압 말뚝재하시험(BDH PLT)을 이용한 초고층 건축물의 대구경 현장타설말뚝 설계절차에 관한 연구 (A Study on the Design Procedure of Mega Foundations for a High-rise Building Using Bi-Directional High Pressure Pile Load Test (BDH PLT))

  • 김성호;최용규
    • 한국지반환경공학회 논문집
    • /
    • 제10권3호
    • /
    • pp.29-36
    • /
    • 2009
  • 본 논문에서는 초고층 건축물이 풍화대지반에 위치하여 대구경 현장타설 말뚝기초로 지지되고 있는 사례를 분석하였다. 본 논문에서 제시한 말뚝기초의 설계 사례는 "예비설계-검증시험-예비설계의 보완"의 3단계를 거쳐 말뚝기초의 설계를 완성한 대표적인 사례로 볼 수 있으며, 검증시험으로 2회의 양방향 고유압 말뚝재하시험이 수행되었다. 이와 같은 설계절차를 준수할 경우 말뚝기초의 경제적인 설계를 수행할 수 있으며, 이를 통하여 말뚝기초 공사비의 대폭적인 절감을 이룰 수 있을 것이다.

  • PDF

확장판 선단부착 PHC말뚝 및 볼트 수직이음을 사용한 PHC말뚝의 시공 중 건전성 확인을 위한 동재하시험의 적용성 및 변형시공법 PHC말뚝들의 올바른 검증시험에 관한 연구 (Study on the Applicability of Dynamic Pile Load Test to Check Integrity during Installation of Extension Plate Attached PHC Piles and Bolts Spliced PHC Piles and the Correct Proof Test of the Transformed-installation PHC Piles)

  • 김명학;최용규
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.115-131
    • /
    • 2018
  • 현장 시험 부지에서 확장판 선단부착 PHC말뚝 및 볼트 수직이음 PHC말뚝에 대한 시험시공을 실시하고 시공중 건전성을 동재하시험으로 확인하고 시공 후 말뚝의 건전성을 직접 확인하였다. 그 결과를 분석하여 확장판 선단부착 PHC말뚝 및 볼트 수직이음 PHC말뚝의 시공 중 건전성을 동재하시험의 건전도지수(${\beta}$지수)로 평가할 수 있는지에 대하여 연구하였다. 이론적으로 말뚝 선단에 매우 인접하거나 선단끝단에서 발생하는 손상(특히 확장판 선단부착구 자체의 변형)은 시험기술의 특성상 건전도지수로 정확한 평가하는 데에는 한계가 있었다. 말뚝의 선단부에 바로 인접해서 발생하거나 말뚝선단 끝단에서의 손상을 PDA시험을 통하여 명확하게 평가하는 데에는 시험기술의 이론에 대한 고도의 지식과 경험이 요구되었다. 다른 볼트 수직이음구로 인하여 실질적인 1차원 파동전달이 용접이음에서와 다를 수 있다는 점, 타격에 의해 발생하는 응력파의 파장이 볼트 수직이음구 높이(약 100mm)보다 클 수 있다는 점, PDA 분석 기능 중 베타 프로세싱(Beta processing)이라는 기능 등이 매우 심도 있는 지식과 경험을 토대로 평가해야만 더욱 정밀한 판단이 이루어질 수 있다는 점 등을 종합적으로 고려할 때 일반적인 건전성 평가기술로 볼트 수직이음의 건전성을 평가하는 데에는 한계가 있었다.