• Title/Summary/Keyword: projection index

Search Result 116, Processing Time 0.026 seconds

Newly-designed adaptive non-blind deconvolution with structural similarity index in single-photon emission computed tomography

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4591-4596
    • /
    • 2023
  • Single-photon emission computed tomography SPECT image reconstruction methods have a significant influence on image quality, with filtered back projection (FBP) and ordered subset expectation maximization (OSEM) being the most commonly used methods. In this study, we proposed newly-designed adaptive non-blind deconvolution with a structural similarity (SSIM) index that can take advantage of the FBP and OSEM image reconstruction methods. After acquiring brain SPECT images, the proposed image was obtained using an algorithm that applied the SSIM metric, defined by predicting the distribution and amount of blurring. As a result of the contrast to noise ratio (CNR) and coefficient of variation evaluation (COV), the resulting image of the proposed algorithm showed a similar trend in spatial resolution to that of FBP, while obtaining values similar to those of OSEM. In addition, we confirmed that the CNR and COV values of the proposed algorithm improved by approximately 1.69 and 1.59 times, respectively, compared with those of the algorithm involving an inappropriate deblurring process. To summarize, we proposed a new type of algorithm that combines the advantages of SPECT image reconstruction techniques and is expected to be applicable in various fields.

A Study on the Optimal Angle as Modified Tangential Projection of Knee Bones (무릎뼈의 변형된 접선방향 검사 시 최적의 입사각에 관한 연구)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.919-926
    • /
    • 2021
  • In this study, we wanted to find out the optimal angle as a modified tangential projection of the patella. In the experiment, we used Kyoto Kagaku's PBU-50 phantom. In the supine position, the F-T angle was set to 95°, 105°, 115°, 125°, 135°, 145°, and Patella tangential projection images were obtained by varying the X-ray tube angle by 5° so that the angle between the X-ray centerline and tibia at each angle was 5~20°. Image J was used for image analysis and the congruence angle, lateral patellofemoral angle, patellofemoral index and contrast to noise ratio(CNR) were also measured. SPSS 22 was used for statistical analysis, and the mean values of congruence angle, patellofemoral angle, patellofemoral index, and CNR were compared with Merchant method through one-way batch analysis and corresponding sample t-test. As a result of the study, in the case of congruence angle, the angle of incidence of the knee-angle X-ray centerline was 105°-72.5° (20° tangential irradiation), 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-82.5° (20° tangential irradiation), lateral patellofemoral angle is 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-72.5° (10° tangential irradiation), patellofemoral index is 115°-72.5° (15° tangential irradiation) and 125°-72.5° (10° tangential irradiation) were not significantly different from Merchant method (p> .05). In case of CNR, it is not different from Merchant method at 105°-67.5°, 72.5° (15, 20° tangential irradiation), 115°-67.5°, 72.5°, 77.5° (10, 15, 20° tangential irradiation). (P> .05). Based on the results of this study, high diagnostic value images can be obtained by setting the knee angle and the angle of incidence of the X-ray tube to 115°-72.5° (15° tangential irradiation) during the modified tangential examination of the knee bone. It was confirmed.

Modified Septal Extension Graft for the Correction of Nasal Tip and Columella (코끝과 코기둥의 교정을 위한 변형된 코중격 연장 이식술)

  • Kim, Jun Sik;Choi, Jae Hoon;Choi, Tae Hyun;Kim, Nam Gyun;Lee, Kyung Suk;Han, Ki Hwan;Son, Dae Gu
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.681-687
    • /
    • 2006
  • Purpose: The nose of most Koreans is characterized as a low nasal dorsum, retracted columella, and an acute columella-labial angle. For the surgical correction of the tip and columella, a modified septal extension graft, along with augmentation rhinoplasty has been developed. Methods: With this technique, a septal extension graft is fixed on the entire caudal margin of the septum (the cephalic-caudal axis) and at the same time, it is placed above the anterior nasal spine, in the membranous portion of the septum and at the base of the columella(the anterior-posterior axis). The present report describes the results obtained in 13 patients and offers an analysis of the results as judged by the columella-labial angle and 4 proportional indices(nose height index, nasal bridge length index, nasal tip projection index, columella length index), measured by photogrammetry. Results: The postoperative values obtained in these 5 categories increased significantly compared to the preoperative ones, thus confirming that the projection of tip was augmented, the nose was lengthened, and the columella was advanced caudally and lengthened. Moreover, these positive outcomes were still maintained during the follow-up period, and no side effects, such as saddle nose deformity, were reported. Conclusion: A modified septal extension graft can be considered as an effective method for the surgical correction of the nasal tip and columella in Koreans.

Evaluation of Firmness and Sweetness Index of Tomatoes using Hyperspectral Imaging

  • Rahman, Anisur;Faqeerzada, Mohammad Akbar;Joshi, Rahul;Cho, Byoung-Kwan
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.44-44
    • /
    • 2017
  • The objective of this study was to evaluate firmness, and sweetness index (SI) of tomatoes (Lycopersicum esculentum) by using hyperspectral imaging (HSI) in the range of 1000-1400 nm. The mean spectra of the 95 matured tomato samples were extracted from the hyperspectral images, and the reference firmness and sweetness index of the same sample were measured and calibrated with their corresponding spectral data by partial least squares (PLS) regression with different preprocessing method. The results showed that the regression model developed by PLS regression based on Savitzky-Golay (S-G) second-derivative preprocessed spectra resulted in better performance for firmness, and SI of tomatoes compared to models developed by other preprocessing methods, with correlation coefficients (rpred) of 0.82, and 0.74 with standard error of prediction (SEP) of 0.86 N, and 0.63 respectively. Then, the feature wavelengths were identified using model-based variable selection method, i.e., variable important in projection (VIP), resulting from the PLS regression analyses and finally chemical images were derived by applying the respective regression coefficient on the spectral image in a pixel-wise manner. The resulting chemical images provided detailed information on firmness, and sweetness index (SI) of tomatoes. Therefore, these research demonstrated that HIS technique has a potential for rapid and non-destructive evaluation of the firmness and sweetness index of tomatoes.

  • PDF

Evaluating LIMU System Quality with Interval Evidence and Input Uncertainty

  • Xiangyi Zhou;Zhijie Zhou;Xiaoxia Han;Zhichao Ming;Yanshan Bian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.11
    • /
    • pp.2945-2965
    • /
    • 2023
  • The laser inertial measurement unit is a precision device widely used in rocket navigation system and other equipment, and its quality is directly related to navigation accuracy. In the quality evaluation of laser inertial measurement unit, there is inevitably uncertainty in the index input information. First, the input numerical information is in interval form. Second, the index input grade and the quality evaluation result grade are given according to different national standards. So, it is a key step to transform the interval information input by the index into the data form consistent with the evaluation result grade. In the case of uncertain input, this paper puts forward a method based on probability distribution to solve the problem of asymmetry between the reference grade given by the index and the evaluation result grade when evaluating the quality of laser inertial measurement unit. By mapping the numerical relationship between the designated reference level and the evaluation reference level of the index information under different distributions, the index evidence symmetrical with the evaluation reference level is given. After the uncertain input information is transformed into evidence of interval degree distribution by this method, the information fusion of interval degree distribution evidence is carried out by interval evidential reasoning algorithm, and the evaluation result is obtained by projection covariance matrix adaptive evolution strategy optimization. Taking a five-meter redundant laser inertial measurement unit as an example, the applicability and effectiveness of this method are verified.

Hyperspectral imaging technique to evaluate the firmness and the sweetness index of tomatoes

  • Rahman, Anisur;Park, Eunsoo;Bae, Hyungjin;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.45 no.4
    • /
    • pp.823-837
    • /
    • 2018
  • The objective of this study was to evaluate the firmness and the sweetness index (SI) of tomatoes with a hyperspectral imaging (HSI) technique within the wavelength range of 1000 - 1550 nm. The hyperspectral images of 95 tomatoes were acquired with a push-broom hyperspectral reflectance imaging system, from which the mean spectra of each tomato were extracted from the regions of interest. The reference firmness and sweetness index of the same sample was measured and calibrated with their corresponding spectral data by partial least squares (PLS) regression with different preprocessing methods. The calibration model developed by PLS regression based on the Savitzky-Golay second-derivative preprocessed spectra resulted in a better performance for both the firmness and the SI of the tomatoes compared to models developed by other preprocessing methods. The correlation coefficients ($R_{pred}$) were 0.82, and 0.74 with a standard error of prediction of 0.86 N, and 0.63, respectively. Then, the feature wavelengths were identified using a model-based variable selection method, i.e., variable importance in projection, from the PLS regression analyses. Finally, chemical images were derived by applying the respective regression coefficients on the spectral image in a pixel-wise manner. The resulting chemical images provided detailed information on the firmness and the SI of the tomatoes. The results show that the proposed HSI technique has potential for rapid and non-destructive evaluation of firmness and the sweetness index of tomatoes.

Evaluation of Image Quality in Micro-CT System Using Constrained Total Variation (TV) Minimization (Micro-CT 시스템에서 제한된 조건의 Total Variation (TV) Minimization을 이용한 영상화질 평가)

  • Jo, Byung-Du;Choi, Jong-Hwa;Kim, Yun-Hwan;Lee, Kyung-Ho;Kim, Dae-Hong;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.252-260
    • /
    • 2012
  • The reduction of radiation dose from x-ray is a main concern in computed tomography (CT) imaging due to the side-effect of the dose on human body. Recently, the various methods for dose reduction have been studied in CT and one of the method is a iterative reconstruction based on total variation (TV) minimization at few-views data. In this paper, we evaluated the image quality between total variation (TV) minimization algorithm and Feldkam-Davis-kress (FDK) algorithm in micro computed tomography (CT). To evaluate the effect of TV minimization algorithm, we produced a cylindrical phantom including contrast media, water, air inserts. We can acquire maximum 400 projection views per rotation of the x-ray tube and detector. 20, 50, 90, 180 projection data were chosen for evaluating the level of image restoration by TV minimization. The phantom and mouse image reconstructed with FDK algorithm at 400 projection data used as a reference image for comparing with TV minimization and FDK algorithm at few-views. Contrast-to-noise ratio (CNR), Universal quality index (UQI) were used as a image evaluation metric. When projection data are not insufficient, our results show that the image quality of reconstructed with TV minimization is similar to reconstructed image with FDK at 400 view. In the cylindrical phantom study, the CNR of TV image was 5.86, FDK image was 5.65 and FDK-reference was 5.98 at 90-views. The CNR of TV image 0.21 higher than FDK image CNR at 90-views. UQI of TV image was 0.99 and FDK image was 0.81 at 90-views. where, the number of projection is 90, the UQI of TV image 0.18 higher than FDK image at 90-views. In the mouse study UQI of TV image was 0.91, FDK was 0.83 at 90-views. the UQI of TV image 0.08 higher than FDK image at 90-views. In cylindrical phantom image and mouse image study, TV minimization algorithm shows the best performance in artifact reduction and preserving edges at few view data. Therefore, TV minimization can potentially be expected to reduce patient dose in clinics.

Hotelling T2 Index Based PCA Method for Fault Detection in Transient State Processes (과도상태에서의 고장검출을 위한 Hotelling T2 Index 기반의 PCA 기법)

  • Asghar, Furqan;Talha, Muhammad;Kim, Se-Yoon;Kim, SungHo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.4
    • /
    • pp.276-280
    • /
    • 2016
  • Due to the increasing interest in safety and consistent product quality over a past few decades, demand for effective quality monitoring and safe operation in the modern industry has propelled research into statistical based fault detection and diagnosis methods. This paper describes the application of Hotelling $T^2$ index based Principal Component Analysis (PCA) method for fault detection and diagnosis in industrial processes. Multivariate statistical process control techniques are now widely used for performance monitoring and fault detection. Conventional methods such as PCA are suitable only for steady state processes. These conventional projection methods causes false alarms or missing data for the systems with transient values of processes. These issues significantly compromise the reliability of the monitoring systems. In this paper, a reliable method is used to overcome false alarms occur due to varying process conditions and missing data problems in transient states. This monitoring method is implemented and validated experimentally along with matlab. Experimental results proved the credibility of this fault detection method for both the steady state and transient operations.

Projected Future Extreme Droughts Based on CMIP6 GCMs under SSP Scenarios (SSP 시나리오에 따른 CMIP6 GCM 기반 미래 극한 가뭄 전망)

  • Kim, Song-Hyun;Nam, Won-Ho;Jeon, Min-Gi;Hong, Eun-Mi;Oh, Chansung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.66 no.4
    • /
    • pp.1-15
    • /
    • 2024
  • In recent years, climate change has been responsible for unusual weather patterns on a global scale. Droughts, natural disasters triggered by insufficient rainfall, can inflict significant social and economic consequences on the entire agricultural sector due to their widespread occurrence and the challenge in accurately predicting their onset. The frequency of drought occurrences in South Korea has been rapidly increasing since 2000, with notably severe droughts hitting regions such as Incheon, Gyeonggi, Gangwon, Chungbuk, and Gyeongbuk in 2015, resulting in significant agricultural and social damage. To prepare for future drought occurrences resulting from climate change, it is essential to develop long-term drought predictions and implement corresponding measures for areas prone to drought. The Intergovernmental Panel on Climate Change (IPCC) Sixth Assessment Report outlines a climate change scenario under the Shared Socioeconomic Pathways (SSPs), which integrates projected future socio-economic changes and climate change mitigation efforts derived from the Coupled Model Intercomparison Project 6 (CMIP6). SSPs encompass a range of factors including demographics, economic development, ecosystems, institutions, technological advancements, and policy frameworks. In this study, various drought indices were calculated using SSP scenarios derived from 18 CMIP6 global climate models. The SSP5-8.5 scenario was employed as the climate change scenario, and meteorological drought indices such as the Standardized Precipitation Index (SPI), Self-Calibrating Effective Drought Index (scEDI), and Standardized Precipitation Evapotranspiration Index (SPEI) were utilized to analyze the prediction and variability of future drought occurrences in South Korea.

Virtual Directory Extendible Hash index: An Economic Hash Index Using New Directory Structure (가상 디렉토리 확장 해시 색인: 확장 해싱에서의 새로운 디렉토리 구조를 이용한 저비용 해시 색인)

  • Park, Sang-Keun;Park, Soon-Young;Kim, Myung-Keun;Bae, Hae-Young
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.11c
    • /
    • pp.1493-1496
    • /
    • 2003
  • 데이터베이스 관계 연산자 중 프로젝션(projection)과 집단 연산(aggregate function)시 사용되는 GROUP BY절, 그리고 동등 조인(equi join)에 대한 질의 처리는 중복된 튜플 중복된 GROUP BY 필드, 조인 중 발생하는 임시결과에 대한 제거나 집단 연산, 임시 결과의 저장을 위해 정렬이나 해싱 기반 알고리즘을 적용하고 있다. 이 중 해싱 기반 알고리즘은 데이터에 대한 직접적인 접근 방법과 정렬비용이 없다는 장점으로 인해 자주 사용하게 된다. 그러나 이러한 해싱(extendible hashing)[1] 기반 알고리즘은 키 값이 저장되는 버켓(bucket) 페이지의 넘침(overflow)으로 인해 분할(split)이 발생하는 경우, 분할을 야기시킨 버켓 페이지에 대한 정보를 제외한 동일한 내용의 기존 디렉토리 구조를 배로 확장해야 하는 공간 확장과, 확장된 디렉토리 구조의 유지를 위해 많은 비용을 소모하게 된다. 본 논문에서는 다량의 데이터에 대한 접근 기법과 디렉토리 구조의 저장공간, 유지 비용 절감 및 중복 해시 값을 지니는 데이터를 처리하기위한 해시 색인인 가상 디렉토리 확장 해시 색인을 제안한다. 가상 디렉토리 확장 해시 색인은 디렉토리 구조를 다단계 구조로 유지함으로써, 넓은 저장 공간을 필요로 하는 다량의 데이터에 대한 접근경로 문제를 해결하였고, 가상 디렉토리 레벨이라는 새로운 구조를 통해, 기존 디렉토리 구조의 공간 낭비 및 유지 비용을 최소화 시켰으며, 버켓 페이지를 리스트(list) 구조로 유지함으로써 중복 해시 값에 의한 디렉토리 구조의 연쇄적 분할 문제를 해결하였다.

  • PDF