• Title/Summary/Keyword: progressive failure

Search Result 413, Processing Time 0.03 seconds

Analysis of Crack Localization in Fracture of Concrete Structures (콘크리트 구조물의 파괴에서의 국소화된 균열진행해석)

  • Koo, Ja-Choon;Song, Ha-Won;Shim, Byul;Woo, Seung-Min;Byun, Keun-Joo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.583-586
    • /
    • 2000
  • In this paper, the embedded crack approach that crack is modeled by discontinuous line inside finite element is applied for localized progressive fracture analyses. The algorithm for progressive fracture analyses of concrete structure are enhanced by introducing nonlinear softening curve and unloading algorithm of tension-softening curve which can simulate localized fracture of concrete. The failure analysis results ar compared with existing test results for varification.

  • PDF

Aspergillus Endocarditis after Open Herat Surgery (VSD Closure) (심실중격결손증 수술후 발생한 Aspergillus 심내막염)

  • 임승평
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.240-246
    • /
    • 1979
  • A 15-year-old boy having a small VSD was readmitted with clinical manifestations of acute endocarditis and aortic regurgitation one month after open heart surgery. In spite of vigorous treatment with broad-spectrum antibiotics, high fever persisted. Pseudomonas aeruginosa was isolated just one time among several blood cultures. Progressive pulmonary infarction due to embolization. Progressive congestive heart failure and D.I.C. caused patient`s death. Aspergillus was found in autopsy specimen.

  • PDF

New 3D failure analysis of water-filled karst cave beneath deep tunnel

  • Zhang, R.;Yang, X.L.
    • Geomechanics and Engineering
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • In this study, both 2D and 3D failure shapes of rock mass above the water-filled cavity are put forward when the surrounding rock mass cannot bear the pressure caused by the water-filled cavity. Based on the analytical expressions derived by kinematic approach, the profiles of active and passive failure patterns are plotted. The sensitivity analysis is conducted to explore the influences of different rock parameters on the failure profiles. During the excavation of the deep tunnels above the karst cavity, the water table always changes because of progressive failure of cavity roof. Therefore, it is meaningful to discuss the effects of varying water level on the failure patterns of horizontal rock layers. The changing laws of the scope of the failure pattern obtained in this work show good consistency with the fact, which could be used to provide a guide in engineering.

Evaluation of Progressive Collapse Resisting Capacity of RC structure using the Applied Element Method (응용요소법을 이용한 철근콘크리트 구조물의 연쇄붕괴 저항성능 평가)

  • Park, Hoon;Suk, Chul-Gi;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.31 no.1
    • /
    • pp.41-48
    • /
    • 2013
  • Progressive collapse is generally defined as a local failure of structural members occurring due to abnormal load which results in the partial collapse or total collapse of a structure. Unlike progressive collapse, explosive demolition is a method of inducing the total collapse of structure by removing all or portion of structural members. In explosive demolition the partial collapse of the structural members can be controlled at appropriate time intervals by blasting, to induce the progressive collapse of the structure and control the collapse behavior. In this study, a nonlinear dynamic analysis was carried out in order to apply the progressive collapse process to explosive demolition design of the RC structure. The occurrence of progressive collapse of analytical models was examined according to the number of floors, the removed column height and span length. For models that resisted progressive collapse, progressive collapse resisting capacity was evaluated.

Cap truss and steel strut to resist progressive collapse in RC frame structures

  • Zahrai, Seyed Mehdi;Ezoddin, Alireza
    • Steel and Composite Structures
    • /
    • v.26 no.5
    • /
    • pp.635-647
    • /
    • 2018
  • In order to improve the efficiency of the Reinforced Concrete, RC, structures against progressive collapse, this paper proposes a procedure using alternate path and specific local resistance method to resist progressive collapse in intermediate RC frame structures. Cap truss consists of multiple trusses above a suddenly removed structural element to restrain excessive collapse and provide an alternate path. Steel strut is used as a brace to resist compressive axial forces. It is similar to knee braces in the geometry, responsible for enhancing ductility and preventing shear force localization around the column. In this paper, column removals in the critical position at the first story of two 5 and 10-story regular buildings strengthened using steel strut or cap truss are studied. Based on nonlinear dynamic analysis results, steel strut can only decrease vertical displacement due to sudden removal of the column at the first story about 23%. Cap truss can reduce the average vertical displacement and column axial force transferred to adjacent columns for the studied buildings about 56% and 61%, respectively due to sudden removal of the column. In other words, using cap truss, the axial force in the removed column transfers through an alternate path to adjacent columns to prevent local or general failure or to delay the progressive collapse occurrence.

Analysis of generalized progressive hybrid censored competing risks data

  • Lee, Kyeong-Jun;Lee, Jae-Ik;Park, Chan-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • In reliability analysis, it is quite common for the failure of any individual or item to be attributable to more than one cause. Moreover, observed data are often censored. Recently, progressive hybrid censoring schemes have become quite popular in life-testing problems and reliability analysis. However, a limitation of the progressive hybrid censoring scheme is that it cannot be applied when few failures occur before time T. Therefore, generalized progressive hybrid censoring schemes have been introduced. In this article, we derive the likelihood inference of the unknown parameters under the assumptions that the lifetime distributions of different causes are independent and exponentially distributed. We obtain the maximum likelihood estimators of the unknown parameters in exact forms. Asymptotic confidence intervals are also proposed. Bayes estimates and credible intervals of the unknown parameters are obtained under the assumption of gamma priors on the unknown parameters. Different methods are compared using Monte Carlo simulations. One real data set is analyzed for illustrative purposes.

Design guides to resist progressive collapse for steel structures

  • Mirtaheri, M.;Zoghi, M. Abbasi
    • Steel and Composite Structures
    • /
    • v.20 no.2
    • /
    • pp.357-378
    • /
    • 2016
  • The progressive collapse phenomenon in structures has been interested by civil engineers and the building standards organizations. This is particularly true for the tall and special buildings ever since local collapse of the Ronan Point tower in UK in 1968. When initial or secondary defects of main load carrying elements, overloads or unpredicted loads occur in the structure, a local collapse may be arise that could be distributed through entire structure and cause global collapse. One is not able to prevent the reason of failure as well as the prevention of propagation of the collapse. Also, one is not able to predict the start point of collapse. Therefore we should generalize design guides to whole or the part of structure based on the risk analysis and use of load carrying elements removal scenario. There are some new guides and criteria for elements and connections to be designed to resist progressive collapse. In this paper, codes and recommendations by various researchers are presented, classified and compared for steel structures. Two current design methods are described in this paper and some retrofitting methods are summarized. Finally a steel building with special moment resistant frame is analyzed as a case study based on two standards guidelines. This includes consideration of codes recommendations. It is shown that progressive collapse potential of the building depends on the removal scenario selection and type of analysis. Different results are obtained based on two guidelines.

Model Test and Numerical Analysis for Failure Behaviour of Shallow Tunnel Considering Unsupported Tunnel Length (굴진장을 고려한 얕은 터널파괴거동에 대한 모형실험 및 수치해석)

  • Kim, Young-Min
    • Tunnel and Underground Space
    • /
    • v.15 no.6 s.59
    • /
    • pp.400-410
    • /
    • 2005
  • During excavation of shallow tunnels in soft ground, failure mechanism around the tunnel face have major influence on the stability of tunnels. In this paper, a series of laboratory tests under plane strain condition on the small scale of a shallow tunnel considering unsupported tunnel length has been performed. The results have shown that tunnel failure mechanism changes from failure mode 1 to failure mode 2 as unsupported tunnel length increases. By comparing the experimental and the numerical results, the loosening pressure for the shallow tunnel and progressive failure have been investigated.

Dynamic response of cable-stayed bridges subjected to sudden failure of stays - the 2D problem

  • Raftoyiannis, I.G.;Konstantakopoulos, T.G.;Michaltsos, G.T.
    • Coupled systems mechanics
    • /
    • v.3 no.4
    • /
    • pp.345-365
    • /
    • 2014
  • A significant problem met in engineering practice when designing cable-stayed bridges is the failure of cables. Many different factors can lead to sudden failure of cables, such as corrosion, continuous friction or abrasion, progressive and extended crevice created by fatigue and finally an explosion caused by sabotage or accident, are some of the causes that can lead to the sudden failure of one or more cables. This paper deals with the sudden failure of cables in a special form of cable-stayed bridges with a single line of cables anchored at the central axis of the deck's cross-section. The analysis is carried out by the modal superposition technique where an analytical method developed by the authors in a previous work has been employed.