• Title/Summary/Keyword: progressive area

Search Result 276, Processing Time 0.03 seconds

A study on improvement of SPIHT algorithm using redundancy bit removing (중복비트 제거를 이용한 SPIHT알고리즘의 개선에 관한 연구)

  • 설경호;이원효;고기영;김태형;김두영
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.1920-1923
    • /
    • 2003
  • This paper presents compression rate improvement for SPIHT algorithm though redundancy bit removing. Proposed SPIHT algorithm uses a method to select of optimized threshold from feature of wavelet transform coefficients and removes sign bit if coefficient of LL area. Experimental results show that the proposed algorithm achieves more improvement bit rate and more fast progressive transmission with low bit rate.

  • PDF

Numerical Models of Water Wave with Parabolic and Hyperbolic Forms

  • Lee, Jong-Kyu;Lee, Chang-Hae
    • Korean Journal of Hydrosciences
    • /
    • v.2
    • /
    • pp.25-37
    • /
    • 1991
  • The numerical models of the parabolic equation, applicable only to the progressive wave, and hyperblic equation, which may consider even the reflected wave, were developed and applied to the area of the submerged circular shoal and then results obtained from both models were compared with experimental measurements and each other. The hyperbolic model was further applied to both the detaced breakwater and the breakwater with a gap. The numerical results were plotted and compated with the existing data. Numerical solutions were obtained with the finite difference method.

  • PDF

Effect of Microstructural Factors on Ductility of Drawn Pearlitic Steels (신선가공한 고탄소 강선의 연성에 영향을 주는 미세조직 인자)

  • Nam W. J
    • Transactions of Materials Processing
    • /
    • v.13 no.8
    • /
    • pp.710-715
    • /
    • 2004
  • The effect of microstructural features on ductility of cold drawn pearlitic steels containing 0.52 ~ 0.92 wt%C was investigated. During wire drawing, reduction of area (Rh) increased initially with the progressive realignment of randomly oriented cementite, showed a maximum peak due to the completion of the alignment of most cementite, and decreased with thinning or fragmentation of the aligned cementite. Among factors on ductility, cementite thickness was found to be the most dominant microstructural feature for Rh of drawn pearlitic wires, regardless of transformation temperature and carbon content in steels.

The Main Contents of the (국가균형발전 5개년계획의 추진전략과 주요내용 - 국토구조구축과 건설산업의 SOC투자를 중심으로 -)

  • Chung, Moo-Yong
    • Journal of the Korean Professional Engineers Association
    • /
    • v.38 no.1
    • /
    • pp.35-43
    • /
    • 2005
  • What are main contents of Balanced National Development Five Years Plan? We will study for contents and policies of the plan's six themes. Six themes of the plan are the drive strategy, the rearing of the worldwide progressive cluster, the local promotion in the strategic industry, the formation of the square national circulation road network, the consolidation of the metropolitan area and the independent drop-out region, and the fund and raising plan. And especially, we will study the details of the national land-structure network formation.

  • PDF

A Study of Bearing Strength on Composite Pinned-Joint at Low Temperature (저온환경에서 복합재료 핀 연결부의 Bearing 강도에 관한 연구)

  • Her, N.I.;Lee, S.Y.;Kim, J.H.;Lee, Y.S.;Sa, J.W.;Cho, S.;Im, K.H.;Oh, Y.K.;Choi, C.H.;Do, C.J.;Kwon, M.;Lee, G.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.413-418
    • /
    • 2001
  • Fundamental failure mode in a laminated composite pinned-joint is proposed to assess damage resulting from stress concentration in the plate. The joint area is a region with stress concentrations thus a complicated stress state exists. The modeling of damage in a laminated composite pinned-joint presents many difficulties because of the complexity of the failure process. In order to model progressive from initial to final, finite element methods are used rather than closed form stress analyses. Failure analysis must be a logical combination of suitable failure criteria and appropriate material properties degradation rules. In this study, the material properties which were obtained in previous study, the preparing process of the bearing strength test for a pinned joint CFRP composite plate subjected to in-plane loading at low temperature, and the FEM result of progressive damage model using ANSYS program are summarized to assess the structural safety of CFRP plate used in the magnetic supporting post of KSTAR(Korea Superconducting Tokamak Advanced Research).

  • PDF

Serum Levels of Interleukin-8 and Tumor Necrosis Factor-alpha in Coal Workers' Pneumoconiosis: One-year Follow-up Study

  • Lee, Jong-Seong;Shin, Jae-Hoon;Lee, Joung-Oh;Lee, Kyung-Myung;Kim, Ji-Hong;Choi, Byung-Soon
    • Safety and Health at Work
    • /
    • v.1 no.1
    • /
    • pp.69-79
    • /
    • 2010
  • Objectives: Various cytokines induced by inhalation of coal dust may mediate inflammation and lead to tissue damage or fibrosis, such as coal workers' pneumoconiosis (CWP). Methods: To investigate the relevance of serum cytokines in CWP, the levels of serum interleukin-8 (IL-8) and tumor necrosis factor-alpha (TNF-${\alpha}$) as CWP biomarkers in 110 retired coal miners (22 controls and 88 CWP subjects) were related to cross sectional findings and 1-year progressive changes of the pneumoconiosis. Progressive changes of CWP were evaluated by paired comparison of chest radiographs. Analysis by a receiver operating characteristic curve assessed the biomarker potential of each cytokine. Results: The mean serum IL-8 level was significantly higher in CWP compared to controls and IL-8 levels correlated with the degree of CWP. The median serum TNF-${\alpha}$ level was significantly higher in subjects with progressive CWP compared to subjects without CWP progression. The area under the ROC curve for IL-8 (0.70) and TNF-${\alpha}$ (0.72) for CWP identification and progression, respectively, indicated the biomarker potential of the two cytokines. Serum cutoff values of IL-8 and TNF-${\alpha}$ were 11.63 pg/mL(sensitivity, 69%; specificity, 64%) and 4.52 pg/mL (sensitivity, 67%; specificity, 79%), respectively. Conclusion: The results suggest that high levels of serum IL-8 are associated with the presence of CWP and those of serum TNF-${\alpha}$ are associated with the progression of CWP.

18F-THK5351 PET Imaging in Nonfluent-Agrammatic Variant Primary Progressive Aphasia

  • Yoon, Cindy W;Jeong, Hye Jin;Seo, Seongho;Lee, Sang-Yoon;Suh, Mee Kyung;Heo, Jae-Hyeok;Lee, Yeong-Bae;Park, Kee Hyung;Okamura, Nobuyuki;Lee, Kyoung-Min;Noh, Young
    • Dementia and Neurocognitive Disorders
    • /
    • v.17 no.3
    • /
    • pp.110-119
    • /
    • 2018
  • Background and Purpose: To analyze $^{18}F-THK5351$ positron emission tomography (PET) scans of patients with clinically diagnosed nonfluent/agrammatic variant primary progressive aphasia (navPPA). Methods: Thirty-one participants, including those with Alzheimer's disease (AD, n=13), navPPA (n=3), and those with normal control (NC, n=15) who completed 3 Tesla magnetic resonance imaging, $^{18}F-THK5351$ PET scans, and detailed neuropsychological tests, were included. Voxel-based and region of interest (ROI)-based analyses were performed to evaluate retention of $^{18}F-THK5351$ in navPPA patients. Results: In ROI-based analysis, patients with navPPA had higher levels of THK retention in the Broca's area, bilateral inferior frontal lobes, bilateral precentral gyri, and bilateral basal ganglia. Patients with navPPA showed higher levels of THK retention in bilateral frontal lobes (mainly left side) compared than NC in voxel-wise analysis. Conclusions: In our study, THK retention in navPPA patients was mainly distributed at the frontal region which was well correlated with functional-radiological distribution of navPPA. Our results suggest that tau PET imaging could be a supportive tool for diagnosis of navPPA in combination with a clinical history.

Analysis of Radiation Treatment Planning by Dose Calculation and Optimization Algorithm (선량계산 및 최적화 알고리즘에 따른 치료계획의 영향 분석)

  • Kim, Dae-Sup;Yoon, In-Ha;Lee, Woo-Seok;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.137-147
    • /
    • 2012
  • Purpose: Analyze the Effectiveness of Radiation Treatment Planning by dose calculation and optimization algorithm, apply consideration of actual treatment planning, and then suggest the best way to treatment planning protocol. Materials and Methods: The treatment planning system use Eclipse 10.0. (Varian, USA). PBC (Pencil Beam Convolution) and AAA (Anisotropic Analytical Algorithm) Apply to Dose calculation, DVO (Dose Volume Optimizer 10.0.28) used for optimized algorithm of Intensity Modulated Radiation Therapy (IMRT), PRO II (Progressive Resolution Optimizer V 8.9.17) and PRO III (Progressive Resolution Optimizer V 10.0.28) used for optimized algorithm of VAMT. A phantom for experiment virtually created at treatment planning system, $30{\times}30{\times}30$ cm sized, homogeneous density (HU: 0) and heterogeneous density that inserted air assumed material (HU: -1,000). Apply to clinical treatment planning on the basis of general treatment planning feature analyzed with Phantom planning. Results: In homogeneous density phantom, PBC and AAA show 65.2% PDD (6 MV, 10 cm) both, In heterogeneous density phantom, also show similar PDD value before meet with low density material, but they show different dose curve in air territory, PDD 10 cm showed 75%, 73% each after penetrate phantom. 3D treatment plan in same MU, AAA treatment planning shows low dose at Lung included area. 2D POP treatment plan with 15 MV of cervical vertebral region include trachea and lung area, Conformity Index (ICRU 62) is 0.95 in PBC calculation and 0.93 in AAA. DVO DVH and Dose calculation DVH are showed equal value in IMRT treatment plan. But AAA calculation shows lack of dose compared with DVO result which is satisfactory condition. Optimizing VMAT treatment plans using PRO II obtained results were satisfactory, but lower density area showed lack of dose in dose calculations. PRO III, but optimizing the dose calculation results were similar with optimized the same conditions once more. Conclusion: In this study, do not judge the rightness of the dose calculation algorithm. However, analyzing the characteristics of the dose distribution represented by each algorithm, especially, a method for the optimal treatment plan can be presented when make a treatment plan. by considering optimized algorithm factors of the IMRT or VMAT that needs to optimization make a treatment plan.

  • PDF

A Study on the Economic Evaluation with Super-Micro Fuel Cell Home Cogeneration System by Varying the Floor Area of House (주택면적의 변화에 따른 가정용 초소형 연료전지 코제너레이션 시스템의 경제성 분석에 관한 연구)

  • Roh, Chul-Woo;Kim, Min-Soo
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.45-51
    • /
    • 2008
  • The fuel cell system is environment-friendly and energy efficient system. Especially, the fuel cell cogeneration systems providing heat and electricity to buildings have been developed and applied to a lot of sites in the world to cope with the global warming and $CO_2$ emission problem. This paper presents the result of study on the economic evaluation with super-micro fuel cell (SMFC) cogeneration system by varying the floor area ($132m^2{\sim}331m^2$) of the house, whose system capacity ranges from 0.10 kWe to 0.50 kWe. The electricity demand, heat demand, saved energy cost, and the simple pay-back period have been simulated for the various capacities of fuel cell cogeneration system. As a result, this study suggests the fuel cell system’s capacity decision strategy for a given house area. Contrary to conventional design assumptions, the smaller capacity fuel cell cogeneration system is appropriate for the house of large floor area to defense the progressive electricity tax, and the larger capacity fuel cell cogeneration system is appropriate for the house of small floor area to sell the electricity.

  • PDF

A Study on the Economic Evaluation with Super-Micro Fuel Cell Home Cogeneration System by Varying the Floor Area of House (주택면적의 변화에 따른 가정용 초소형 연료전지 코제너레이션 시스템의 경제성 분석에 관한 연구)

  • Roh, Chul-Woo;Kim, Min-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.25-28
    • /
    • 2008
  • The fuel cell system is environment-friendly and energy efficient system. Especially, the fuel cell cogeneration systems providing heat and electricity to buildings have been developed and applied to a lot of sites in the world to cope with the global warming and $CO_2$ emission problem. This paper presents the result of study on the economic evaluation with super-micro fuel cell (SMFC) cogeneration system by varying the floor area ($132m^2{\sim}331m^2$) of the house, whose system capacity ranges from 0.10 kWe to 0.50 kWe. The electricity demand, heat demand, saved energy cost, and the simple pay-back period have been simulated for the various capacities of fuel cell cogeneration system. As a result, this study suggests the fuel cell system's capacity decision strategy for a given house area. Contrary to conventional design assumptions, the smaller capacity fuel cell cogeneration system is appropriate for the house of large floor area to defense the progressive electricity tax, and the larger capacity fuel cell cogeneration system is appropriate for the house of small floor area to sell the electricity.

  • PDF