• Title/Summary/Keyword: profilometer

Search Result 143, Processing Time 0.02 seconds

Development of Prototype Stylus Prototype for Large Optics Testing

  • Yang, Ho-Soon;Walker, David
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.60-66
    • /
    • 2001
  • The authors discuss a prototype stylus profilometer designed to measure large optics. It consists of a low contact force type probe system, laser reference system, interferometric distance measurement system, and horizontal driving system. The probe contacts the surface ; the height and the horizontal distances of the measurement points are measured by the interferometer. The freely propagated laser beam provides the reference line during the measurement. The developed stylus profilometry shows only $\pm$60 nm of P-V error for the 157 mm diameter spherical mirror.

Effects of ICP Power on the Properties of TiCrN Films (유도결합플라즈마의 전력이 TiCrN 코팅층에 미치는 영향)

  • Cha, B.C.;Kim, J.H.;Lee, B.S.;Kim, S.K.;Kim, D.W.;Kim, D.;You, Y.Z.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.5
    • /
    • pp.307-311
    • /
    • 2009
  • In this study, TiCrN films were deposited on STS 316 Land Si (100) wafer by inductively coupled plasma (ICP) assisted D.C. magnetron sputtering. The effect R.F. power for ICP discharge on the mechanical properties of TiCrN films was investigated. XRD, XPS and FE-SEM were used for the structure analysis. Also the Micro-Knoop hardness tester and profilometer were used for measuring hardness of coatings and film stress respectively. As increasing the R.F. power for ICP discharge, thickness of coating was decreased from 1633 nm to 1288 nm but hardness was increased about $Hk_{5g}$ 4200 at 400 W. All of the XRD patterns showed (111), (200) and (220) peaks of TiCrN films. Surface morphology was studied using the profilometer. FE-SEM was used to know morphology and cross-section of the films. Structure of the films was changed dense as increased ICP power.

Removal of mid-frequency error from the off-axis mirror

  • Kim, Sanghyuk;Pak, Soojong;Jeong, Byeongjoon;Shin, Sangkyo;Kim, Geon Hee;Lee, Gil Jae;Chang, Seunghyuk;Yoo, Song Min;Lee, Kwang Jo;Lee, Hyuckee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.103-103
    • /
    • 2014
  • Manufacturing of lens and mirror using Diamond Turning Machine (DTM) offers distinct advantages including short fabrication time and low cost as compared to grinding or polishing process. However, the DTM process can leave mid-frequency error in the optical surface which generates an undesirable diffraction effect and stray light. The mid-frequency error is expected to be eliminated by mechanical polishing after the DTM process, but polishing of soft surface of ductile aluminum is extremely difficult because the polishing process inevitably degrades the surface form accuracy. In order to increase its surface hardness, we performed electroless nickel plating on the surface of diamond-turned aluminum (Al-6061T6) off-axis mirrors, which was followed by the 6-hour-long baking process at $200^{\circ}C$ for improving its hardness. Then we polished the nickel plated off-axis mirrors to remove the mid-frequency error and measured polished mirror surfaces using the optical surface profilometer (NT 2000, Wyko Inc.). Finally, we ascertained that the mid-frequency error on the mirror surface was successfully removed. During the whole processes of nickel plating and polishing, we monitored the form accuracy using the ultra-high accurate 3-D profilometer (UA3P, Panasonic Corp.) to maintain it within the allowable tolerance range (< tens of nm). The polished off-axis mirror was optically tested using a visible laser source and a pinhole, and the airy pattern obtained from the polished mirror was compared with the unpolished case to check the influence of mid-frequency error on optical images.

  • PDF

Accurate Roughness Measurement Using a Method for Evaluation and Interpolation of the Validity of Height Data from a Scanning White-light Interferometer

  • Kim, Namyoon;Lee, Seung Woo;I, Yongjun;Pahk, Heui-Jae
    • Current Optics and Photonics
    • /
    • v.1 no.6
    • /
    • pp.604-612
    • /
    • 2017
  • An effective and precise method using a scanning white-light interferometer (SWLI) for three-dimensional surface measurements, in particular for roughness measurements, has been proposed. The measurement of a microscopically sloped area using an interferometer has limitations, due to the numerical aperture of the lens. In particular, for roughness measurements, it is challenging to obtain accurate height data for a sloped area using the interferometer, due to diffraction of the light. Owing to these optical limitations of the interferometer for roughness measurements, the Ra measurements performed using an interferometer contain errors. To overcome the limitations, we propose a method consisting of the following two steps. First, we evaluate the height data and set the invalid height area to be blank, using the characteristics of the modulus peak, which has a low peak value for signals that have low reliability in the interferogram. Next, we interpolate the blank area using the adjacent reliable area. Rubert roughness standards are used to verify the proposed method. The results obtained by the proposed method are compared to those obtained with a stylus profilometer. For the considered sinusoidal samples, Ra ranges from $0.053{\mu}m$ to $6.303{\mu}m$, and we show that the interpolation method is effective. In addition, the method can be applied to a random surface where Ra ranges from $0.011{\mu}m$ to $0.164{\mu}m$. We show that the roughness results obtained using the proposed method agree well with profilometer results. The $R^2$ values for both sinusoidal and random samples are greater than 0.995.

Surface characteristics and osteoblastic cell response of alkali-and heat-treated titanium-8tantalum-3niobium alloy

  • Lee, Bo-Ah;Kang, Choong-Hee;Vang, Mong-Sook;Jung, Young-Suk;Piao, Xing Hui;Kim, Ok-Su;Chung, Hyun-Ju;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.6
    • /
    • pp.248-255
    • /
    • 2012
  • Purpose: The aim of the present study was to evaluate the biological response of alkali- and heat-treated titanium-8tantalum-3niobium surfaces by cell proliferation and alkaline phosphatase (ALP) activity analysis. Methods: Commercial pure titanium (group cp-Ti) and alkali- and heat-treated titanium-8tantalum-3niobium (group AHT) disks were prepared. The surface properties were evaluated using scanning electron microscopy, energy dispersed spectroscopy and X-ray photoelectron spectroscopy (XPS). The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were also analyzed. The biological response of fetal rat calvarial cells on group AHT was assessed by cell proliferation and ALP activity. Results: Group AHT showed a flake-like morphology microprofile and dense structure. XPS analysis of group AHT showed an increased amount of oxygen in the basic hydroxyl residue of titanium hydroxide groups compared with group cp-Ti. The surface roughness (Ra) measured by a profilometer showed no significant difference (P>0.05). Group AHT showed a lower contact angle and higher surface energy than group cp-Ti. Cell proliferation on group AHT surfaces was significantly higher than on group cp-Ti surfaces (P<0.05). In comparison to group cp-Ti, group AHT enhanced ALP activity (P<0.05). Conclusions: These results suggest that group AHT stimulates osteoblast differentiation.

A morphologic evaluation of defects created by a piezoelectric ultrasonic scaler on casting gold alloy (압전방식초음파치석제거기의작업조건에따른치과주조용합금의삭제결손부 양상에 관한 고찰)

  • Kim, Young-Sung;Kim, Soo-Hwan;Kim, Won-Kyung;Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.4
    • /
    • pp.385-390
    • /
    • 2009
  • Purpose: In this study we evaluated the morphologic aspects of defects created by a piezoelectric ultrasonic scaler with scaler tip on casting gold alloy using scanning electron microscope (SEM) images and defect surface profiles. Methods: 54 blocks of type III casting gold alloy (Firmilay, Jellenko Inc, CA, USA) were scaled by a piezoelectric ultrasonic scaler (P-MAX, Satelec, France) with scaler tip (No. 1 tip) on a sledge device. 2-dimensional profiles of defects on all samples were investigated by a surface profilometer (a-Step 500, KLA-Tencor, CA, USA). The selected working parameters were lateral force (0.5 N, 1.0 N, 2.0 N), mode (P mode, S mode), and power setting (2, 4, 8). SEM images were obtained. Defect surface profiles were made on Microsoft Excel program using data obtained by a surface profilometer. Results: Among P mode samples, there were similarities on defect surface profiles and SEM images regardless of lateral force. The defects created in P mode were narrow and shallow although the depth and the width increased as power setting changed low (2) to high (8). In P mode samples, the defect depth was the greatest when lateral force of 0.5 N was applied. However all the depths were smaller than 1 m. SEM images of Lateral force of 0.5 N, S mode, power setting 2 and 4 were similar to that of P mode, but the other SEM images of S mode showed discernible changes. Defect depth of S mode samples was the greatest when lateral force of 1.0 N was applied. Conclusions: Within the limitations of this study, it can be concoluded that removing capability of piezoelectric scaler with scaler tip becomes maximized as power level becomes higher but the capability is restricted when excessive lateral force is applied on scaler tip.

Surface characteristics and bioactivity of an anodized titanium surface

  • Kim, Kyul;Lee, Bo-Ah;Piao, Xing-Hui;Chung, Hyun-Ju;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.198-205
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the surface properties and biological response of an anodized titanium surface by cell proliferation and alkaline phosphatase activity analysis. Methods: Commercial pure titanium (Ti) disks were prepared. The samples were divided into an untreated machined Ti group and anodized Ti group. The anodization of cp-Ti was formed using a constant voltage of 270 V for 60 seconds. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, and an image analyzing microscope. The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were analyzed. Cell adhesion, cell proliferation, and alkaline phosphatase activity were evaluated using mouse $MC_3T_3-E_1$ cells. Results: The anodized Ti group had a more porous and thicker layer on its surface. The surface roughness of the two groups measured by the profilometer showed no significant difference (P>0.001). The anodized Ti dioxide ($TiO_2$) surface exhibited better corrosion resistance and showed a significantly lower contact angle than the machined Ti surface (P>0.001). Although there was no significant difference in the cell viability between the two groups (P>0.001), the anodized $TiO_2$ surface showed significantly enhanced alkaline phosphatase activity (P<0.001). Conclusions: These results suggest that the surface modification of Ti by anodic oxidation improved the osteogenic response of the osteoblast cells.

Experiments Investigating the Local Paper Structure

  • Sung, Yong-Joo;Keller, D. Steven
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2002.11a
    • /
    • pp.36-46
    • /
    • 2002
  • The accurate characterization of paper structure may provide critical information for ideal selection of raw materials and papermaking processes as well as for predicting the behavior and the quality of final paper products. In this study, local paper structure and the relationship among the structural parameters, thickness, grammage, apparent density and surface roughness of various handsheet and commercial paper samples were evaluated by using recently developed methods. A new concept of surface roughness was also introduced. The results demonstrate that there is significant overestimation in the measured thickness when using the conventional caliper method that originates from the surface roughness and poor paper formation. A novel non-contact thickness tester, referred to as the twin laser profilometer(TLP), provided results that were not subject to these artifacts and thus provided the local intrinsic thickness and consequently the local intrinsic apparent density.

  • PDF

IN VIVO AND IN VITRO WEAR TEST OF COMPOSSITE RESIN RETORATION (복합레진의 마모에 관한 임상적, 실험적 평가)

  • Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.129-135
    • /
    • 1999
  • In this review article, in vivo and in vitro wear test methods which measure the wear of tooth and restorative material were discribed. In vivo test, the criteria of each test were reviewed. The merits and limitations were also commented. In vitro tests, three dimensional scanning methods which scan the occlusal tooth surface three dimensionally were described. Profilometer method, Pin on disk method, laser scanner method were reviewed and the limitations of each test were commented. Additionally, the structer of the three dimensional scanner which has been developed in Zurich university and has been reputated as the most accurate one was described. This study was partly supported by 1997 post-doctoral foreign study program.

  • PDF

A STUDY ON THE ROUGHNESS OF THE VISIBLE LIGHT CURED COMPOSITE RESINS (가시광선(可視光線) 중합형(重合型) 복합(複合)레진의 표면조도(表面粗度)에 관(關)한 연구(硏究))

  • Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.197-212
    • /
    • 1991
  • The purpose of this study was to roughness on the polished surface of visible light composite resins and was to observe the polished surfaces under Scanning Electrom Microscope(ISI DS 130 AKASHI Co. JAPAN). The surface roughness tester(Surfcom 700A Seimtsu profilometer Tokyo, Japan) was used to measure roughness of polished surfaces. In this study, 5 brands of visible of composite resins were examined, Pyrofile light bond Anterior Lite fil anterior Photo clearfil anterior & posterior Palfique light Anterior and posterior Silux Anterior. White point, Silicure point, Super snap Sof-Lex medium disk as cutting instrument, and celluloid matrix were used. The results obtained were as follows. 1. The Celluloid matrix produced the smoothest surfaces. 2. The surfaces made by Soflex medium disk was smoother than the surfaces made by any other polishing instruments. 3. The values of surface roughness made by White point, Silicon point and Super snap were similer. 4. Palfique light (AP) visible light composite resin showed the smoothest surface after polishing with Silicone point, Super snap disk and Soflex mediuem disk in all tested materials.

  • PDF