• 제목/요약/키워드: process and worker safety

검색결과 127건 처리시간 0.026초

Development of a Web Platform System for Worker Protection using EEG Emotion Classification (뇌파 기반 감정 분류를 활용한 작업자 보호를 위한 웹 플랫폼 시스템 개발)

  • Ssang-Hee Seo
    • Journal of Internet of Things and Convergence
    • /
    • 제9권6호
    • /
    • pp.37-44
    • /
    • 2023
  • As a primary technology of Industry 4.0, human-robot collaboration (HRC) requires additional measures to ensure worker safety. Previous studies on avoiding collisions between collaborative robots and workers mainly detect collisions based on sensors and cameras attached to the robot. This method requires complex algorithms to continuously track robots, people, and objects and has the disadvantage of not being able to respond quickly to changes in the work environment. The present study was conducted to implement a web-based platform that manages collaborative robots by recognizing the emotions of workers - specifically their perception of danger - in the collaborative process. To this end, we developed a web-based application that collects and stores emotion-related brain waves via a wearable device; a deep-learning model that extracts and classifies the characteristics of neutral, positive, and negative emotions; and an Internet-of-things (IoT) interface program that controls motor operation according to classified emotions. We conducted a comparative analysis of our system's performance using a public open dataset and a dataset collected through actual measurement, achieving validation accuracies of 96.8% and 70.7%, respectively.

Trends of Industrial Injuries among Long-Term Health Care Workers in Korea (한국 요양보호사 산업재해의 연도별 변화추이)

  • Son, Mia;Jeon, Geo-Song;Bae, Dong-Chul;Son, Byungchang;Kim, Taeun;Yun, Jae-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제31권2호
    • /
    • pp.156-172
    • /
    • 2021
  • Objectives: To investigate the trends of industrial injuries among long-term health care workers in Korea Methods: T7866 injuries were selected from the total industrial injuries approved by the Industrial Accident Compensation Insurance Act(Occupational Safety and Health Act) among long-term health care workers between 2007 and 2016 in Korea. We analyzied the trends of industrial injuries according to work process, occurrence type, and causes. Results: The industrial injuries among long-term health care workers increased since 2012. The mostly occurred area for industrial injuries were low back areas, which is related that the most serious industrial injuries occurred when the one long-term healthcare worker lift manually the recipient, from bed(ondol, Korean floor heating system) to a wheelchair, bed to bath bed, and wheelchair to bath chair. In addition to this, lack of workforce, increased work intensity due to overwork contributed the increasing of occupational injury. Conclusions: This study suggests that the main causes of industrial injuries were Lack of facilities and equipment for small private long-term care institutions, The physical load that goes into lifting the recipient directly, work intensity such as excessive workload and increased work speed. We suggest that the social publicization of long-term care service for the elderly, avoiding ways to lift recipients directly, introducing lifting machines as well as improving working methods, and reducing the workload of caregivers are required.

A Study on Optimal Design for Linear Electromagnetic Generator of Electricity Sensor System using Vibration Energy Harvesting (진동에너지 하베스팅을 이용한 전력감지시스템용 리니어 전자기 발전기에 관한 최적설계)

  • Cho, Seong Jin;Kim, Jin Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • 제16권2호
    • /
    • pp.7-15
    • /
    • 2017
  • Recently, an electricity sensor system has been installed and operated to prevent failures and accidents by identifying whether a transformer is normal in advance of failure. This electricity sensor system is able to both measure and monitor the transformer's power and voltage remotely and send information to a manager when unusual operation is discovered. However, a battery is required to operate power detection devices, and battery systems need ongoing management such as regular replacement. In addition, at a maintenance cost, occasional human resources and worker safety problems arise. Accordingly, we apply a linear electromagnetic generator using vibration energy from a transformer for an electric sensor system's drive in this research and we conduct optimal design to maximize the linear electromagnetic generator's power. We consider design variables using the provided design method from Process Integration, Automation, and Optimization (PIAnO), which is common tool from process integration and design optimization (PIDO). In addition, we analyze the experiment point from the design of the experiments using "MAXWELL," which is a common electromagnet analysis program. We then create an approximate model and conduct accuracy verification. Finally, we determine the optimal model that generates the maximum power using the proven approximate kriging model and evolutionary optimization algorithm, which we then confirm via simulation.

Design and implementation of IoT platform for collecting and managing the SmartFactory environment information

  • Kim, SungJin;Ra, SangYong;Kim, HwanSeog;Choi, JaeHong;Lee, JunDong
    • Journal of the Korea Society of Computer and Information
    • /
    • 제24권6호
    • /
    • pp.109-115
    • /
    • 2019
  • Smart Factory is a part of and a key point of the 4th industrial revolution. It performs optimization from the whole viewpoint, using comprehensive data of the post-process data by utilizing various sensors, controllers, and mobile devices beyond the existing factory automation level. In this paper, we design and implement an IoT platform that can detect the safety factors of the workers, the environmental factors of the factory, and real time monitoring at the control center, among the fields to implement smart factory. To accomplish this, we construct a monitoring device that provides sensor information control, server transmission of sensor information, and visualization of collected information. By using this system, it is possible to maintain the temperature and humidity for the optimum working environment in the factory. and also, By using the beacon, it is possible to measure the working time of the worker and trace the position.

A Study on the Police Knowledge Management System based on the IntraNet (인트라넷기반의 경찰지식관리시스템에 관한 연구)

  • Choi, Eung-Ryul;Lim, Jae-Kang
    • Korean Security Journal
    • /
    • 제3호
    • /
    • pp.273-305
    • /
    • 2000
  • The knowledge substitutes the traditional factors of production - land, labor, and capital - and has become one of the most important new resources. The Internet Knowledge Society is where the knowledge is the major source of development and competition. Now more than 350mi11ion computers are connected to internet servers and the internet users are more than 250mi11ion. The purpose of this paper is to propose some key factors for implementing the Police Knowledge Management System(PKMS) based on Intranet. With Information Technology(IT), the police administrative system will be much more efficient. Introducing the If into the system is critical for restructuring the police administrative system. This paper concludes as follows : ■ Knowledge is divided into tacit and explicit one. Knowledge process is divided into acquisition, accumulation, distribution and creation of knowledge. ■ The IntraNet is composed of Web server, FTP server, electric-mail server, and is constructed security system to safety. ■ All policemen are bound to serve as a new knowledge worker. ■ Police organization needs to operate data management system. The organization also needs to the Police Knowledge Management Center(PKMC). And the Police Chief Knowledge Officers(PCKO) needs to be appointed to manage the PKMC. ■ An information and knowledge infrastructure(various databases are the most important factor) should be established within the organization to promote the self-directed management, the interactive communication, and the learning ability of the members.

  • PDF

A Study on Noise Reduction in Many-to-Many Communication Applying to Smart Helmets in the Shipyard (조선소 내 스마트 안전모에 적용한 다대다 통신 소음 저감에 관한 연구)

  • Junhyeok Park;Jun Soo Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • 제60권1호
    • /
    • pp.48-56
    • /
    • 2023
  • This paper implements many-to-many communication between users and develops a multi-functional smart helmet for worker protection and environmental safety in the shipbuilding and shipping industry. First, the communication situation is recorded in the field to perform signal processing for noise that interferes with communication. Then, it deals with the contents of developing smart helmets, data acquisition, algorithms, and simulations. The simulation results analyzed by applying the adaptive algorithm are shown, and their usefulness is confirmed. In conclusion, looking at the optimization process for the convergence factor of the Least Mean Square and Filtered-x Least Mean Square Adaptation Algorithm was possible. It is thought that it has laid the foundation for implementing many-to-many communication, the function of smart helmets that reduces or removes various noises at the shipyard in the future.

3D Graphic Simulation for Dismantling Process of the KRR-2 (연구용 원자로 2호기 해체과정 전산모사)

  • 김성균;정관성;백삼태;이근우;박진호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.707-719
    • /
    • 2003
  • The D&D work requires worker's safety and high reliability of operation because it has been processing in high radioactive environment. Therefore, it is necessary to select the dismantling items and applicable dismantling technologies and analyze the scenarios for selected items. In this paper, the main dismantling items were selected by the consideration of several factors, their 3D CAD models were constructed as well. The applicable dismantling technologies for each dismantling items were selected and their dismantling scenarios were setup. Finally the 3D graphic simulations for the shielding concrete, the RSR, and the core are performed.

  • PDF

Characteristics of Workers' Exposure to Aerosolized Particles during the Production of Carbon Nanotube-enabled Composites (탄소나노튜브 복합체 취급 작업자의 공기 중 입자상 물질 노출 특성)

  • Kwon, Jiwoon;Kim, Sungho;Jang, Miyeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제30권1호
    • /
    • pp.1-9
    • /
    • 2020
  • Objectives: The purpose of this case study is to assess workers' exposure to carbon nanotubes(CNTs) and characterize particles aerosolized during the process of producing CNT-enabled polytetrafuoroethylene(PTFE) composites at a worksite in Korea. Methods: Personal breathing zone and area samples were collected for determining respirable concentrations of elemental carbon(EC) using NIOSH(National Institute for Occupational Safety and Health) Method 5040. Personal exposure to nano-sized particles was measured as the number concentration and mean diameter using personal ultrafine particle monitors. The number concentration by particle size was measured using optical particle sizers(OPS) and scanning mobility particle sizers(SMPS). Transmission electron microscopy (TEM) area samples were collected on TEM grids and analyzed to characterize the size, morphology, and chemistry of the particles. Results: Respirable EC concentrations ranged from 0.04 to 0.24 ㎍/㎥, which were below 23% of the exposure limit recommended by NIOSH and lower than background concentrations. Number concentrations by particle size measured using OPS and SMPS were not noticeably elevated during CNT-PTFE composite work. Instant increase of number concentrations of nano-sized particles was observed during manual sanding of CNT-PTFE composites. Both number concentrations and mean diameters did not show a statistically significant difference between workers handing CNT-added and not-added materials. TEM analyses revealed the emission of free-standing CNTs and CNT-PTFE aggregate particles from the powder supply task and composite particles embedded with CNTs from the computer numerical control(CNC) machining task with more than tens of micrometers in diameter. No free-standing CNT particles were observed from the CNC machining task. Conclusions: Significant worker exposure to respirable CNTs was not found, but the aerosolization of CNTs and CNT-embedded composite particles were observed during handing of CNT-PTFE powders and CNC machining of CNT-PTFE composites. Considering the limited knowledge on the toxicity of CNTs and CNT composite particles to date, it seems prudent to take a precautionary approach for the protection of workers' health.

A Study on Work's Exposure to Dust, Crystalline Free Silica and Lead in Ceramic Industry (일부 요업사업장의 분진, 결정형 유리규산 및 납의 폭로에 관한 연구)

  • Oh, Se-Min;Shin, Yong-Chul;Park, Dong-Wook;Lee, Na-Roo;Park, Sueng-Hyun;Yi, Gwang-Yong;Moon, Young-Hahn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제4권2호
    • /
    • pp.168-179
    • /
    • 1994
  • In some ceramic industries, worker exposure to dust, crystalline free silica and lead were determined and evaluated. The conclusions are as follows. 1. Crystalline silica in bulk samples was 10.5 % in sanitary ware industry, 9.4 % in tile industry, and 2.1 % in ceramic insulator industry respectively. The free silica content of air filter sample was 8.03 % in table ware industry, 5.59 % in sanitary ware industry, and 1.32 % in ceramic insulator industry. Because silica content in ceramic dust is relatively high, it is should be considered silica as important factor in evaluating for ceramic industry. 2. The silica contents in dust from tile, sanitary ware and table ware industries are above 5%, it should be classified as "Type" 2 dust. 3. The airborne concentration of respirable crystalline silica was $27.9{\mu}g/m^3$ in a sanitary ware factory and $5.8{\mu}g/m^3$ in a ceramic insualtor factory. Three of ten samples sampled the above factories were exceeded the occupational exposure levels, $100{\mu}g/m^3$. 4. Geometric mean(GM) of total dust in 11 factories was $1.00mg/m^3$ and GM of respirable dust concentration in 5 factories was $0.33mg/m^3$. Sanitary ware industry had the highest concentration of total dust, $1.62mg/m^3$ and of respirable dust, $0.88mg/m^3$. 5. Average lead concentration in air was $0.05mg/m^3$ in glazing process of 2 factories manufacturing table ware. Five of ten sample(50%) were exceeded $0.05mg/m^3$. Therefore lead exposure in pottery industry should be considered as important problem.

  • PDF

Characteristics of Internal and External Exposure of Radon and Thoron in Process Handling Monazite (모나자이트 취급공정에서의 라돈 및 토론 노출 특성)

  • Chung, Eun Kyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제29권2호
    • /
    • pp.167-175
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate airborne radon and thoron levels and estimate the effective doses of workers who made household goods and mattresses using monazite. Methods: Airborne radon and thoron concentrations were measured using continuous monitors (Rad7, Durridge Company Inc., USA). Radon and thoron concentrations in the air were converted to radon doses using the dose conversion factor recommended by the Nuclear Safety and Security Commission in Korea. External exposure to gamma rays was measured at the chest height of a worker from the source using real-time radiation instruments, a survey meter (RadiagemTM 2000, Canberra Industries, Inc., USA), and an ion chamber (OD-01 Hx, STEP Co., Germany). Results: When using monazite, the average concentration range of radon was $13.1-97.8Bq/m^3$ and thoron was $210.1-841.4Bq/m^3$. When monazite was not used, the average concentration range of radon was $2.6-10.8Bq/m^3$ and the maximum was $1.7-66.2Bq/m^3$. Since monazite has a higher content of thorium than uranium, the effects of thoron should be considered. The effective doses of radon and thoron as calculated by the dose conversion factor based on ICRP 115 were 0.26 mSv/yr and 0.76 mSv/yr, respectively, at their maximum values. The external radiation dose rate was $6.7{\mu}Sv/hr$ at chest height and the effective dose was 4.3 mSv/yr at the maximum. Conclusions: Regardless of the use of monazite, the total annual effective doses due to internal and external exposure were 0.03-4.42 mSv/yr. Exposures to levels higher than this value are indicated if dose conversion factors based on the recently published ICRP 137 are applied.